MAURY USCG vessel records Sign in
← All vessels

WRECK EXPRESS

WRECK EXPRESS is a 1984 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 2000, most recently in May 2025, along with 72 deficiencies and 1 casualty investigation in 2006.

Records from 2000 to 2025. Most recent: inspection, 13 May 2025.

Built
1984
Last inspected
13 May 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF8228
345975
Flag
UNITED STATES
367492720
Maury page id
psix-345975

Inspections, by type

…with no type recorded3
Years with a record 21 calendar years (2000–2025)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.0 ft × 12.4 ft × 5.6 ft
Registered tonnagegross 17 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA BOAT WORKS INC · CAPE CANAVERAL, FL, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portMUNISING, MI
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Net Ton
17 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF8228MMSI 367492720 · active · compulsorily equipped · granted 16 April 2021, expires 28 May 2031 · licensed under a name not among this hull’s recorded names (not shown)
WDA4305MMSI 366807970 · expired · compulsorily equipped · granted 17 April 2001, cancelled 18 June 2011
WCZ8437MMSI not assigned · expired · compulsorily equipped · granted 25 May 2000, cancelled 31 July 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 42

13 May 2025 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8148014
5 June 2024 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7966657
15 June 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7744998
7 June 2022 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7485032
24 June 2021 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7248541
16 July 2020 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7007483
1 July 2020 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6992484
3 June 2020 Examination of Repairs · Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6986258
3 April 2020 Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6934925
2 October 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6825418
13 September 2019 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6860854
2 July 2019 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6736935
17 September 2018 Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6543353
21 September 2017 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6271898
19 September 2017 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6272445
27 September 2016 Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6016175
17 August 2016 DAPI Audit
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6047373
9 May 2016 Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5896081
8 December 2015 Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5777819
30 September 2015 COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5726074
19 March 2009 Administrative Inspection · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3436883
25 August 2008 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3308797
3 June 2008 Simplified Stability Test
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3238902
17 April 2008 Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3186339
14 January 2008 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 3129924
12 February 2007 Deficiency Check · Damage Survey
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2870892
3 October 2006 Type not recorded
No type recorded · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2798471
10 August 2006 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2742860
22 May 2006 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2656116
30 March 2006 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2626569
2 June 2005 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2376995
3 May 2004 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2060453
23 February 2004 Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2012226
8 August 2003 Type not recorded
No type recorded · USCGC YELLOWFIN (WPB 87319) · USCG Southeast District (CGD-SE) · Activity 1885383
29 April 2003 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1779562
6 January 2003 Administrative Inspection
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1726578
6 May 2002 Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1613587
4 February 2002 Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1483366
4 June 2001 Hull Examination · Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1387089
1 April 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1062237
16 January 2001 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1056819
13 June 2000 Initial Certification · Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1439032

Deficiency record · 72

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 June 2022 Resolved
Hydrostatic release expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 6 July 2022
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 June 2022 Resolved
Oil pressure gauge at upper operating station inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 6 July 2022
Resolution: Corrected.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 July 2020 Resolved
Hydrostatic release on EPIRB is expired. Replace hydrostatic release to the satisfaction of the Coast Guard MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 16 July 2020
Resolution: Replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 July 2020 Resolved
Anchor light is extinguished.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 16 July 2020
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2019 Resolved
Port main diesel engine (MDE) removed & installed in another company vessel. Replace and demonstrate proper operation of the port MDE prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 September 2019
Resolved 7 July 2020
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 September 2018 Resolved
Provide properly serviced & mounted 10-B:C PFE at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2018
Resolved 2 July 2019
Resolution: corrected.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 September 2017 Resolved
First aid kit lacking list of contents. First aid kit has expired items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 11 October 2017
Resolution: List and updated contents provided.
Lifesaving › Lifefloat › Float-free Link
Issued 27 September 2016 Resolved
Properly re-route float free weak link and attached line.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2016
Resolved 27 September 2016
Resolution: Completed.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 30 September 2015 Resolved
Provide current version of navigation rules.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 8 December 2015
Resolution: Owner had provided timely notice of correction, USCG delayed inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 September 2015 Resolved
Provide watertight container for first aid kit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 8 December 2015
Resolution: Owner had provided timely notice of correction, USCG delayed inspection.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 30 September 2015 Resolved
5 adult size Kapok PFDs leak, condemned. Sufficient PFDs remain abaord.
Condition: Improper/Lack of Maintenance
Due 1 October 2015
Resolved 1 October 2015
Documentation › Certificates/Documents › Stability Letter
Issued 30 September 2015 Resolved
Stability letter posted in accomadations, not visible from operating station, corrected.
Condition: Improper Installation
Due 1 October 2015
Resolved 1 October 2015
Engineering › Steering Gear System › Linkage
Issued 30 September 2015 Resolved
Port quadrant snags on improperly designed rudder stop, corrected.
Condition: Design Flaw
Due 1 October 2015
Resolved 1 October 2015
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 September 2015 Resolved
First aid kit contained extra itmes that were expired, corrected.
Condition: Improper/Lack of Maintenance
Due 1 October 2015
Resolved 1 October 2015
Construction/Loadline › Hull › Hull Plating
Issued 19 March 2009 Resolved
Make proper repairs to hull in marked areas (8)
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 April 2009
Lifesaving › Launching Appliances › Release Mechanism
Issued 19 March 2009 Resolved
Stencil hydrostatic release expiration date
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 April 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 19 March 2009 Resolved
Properly repair water light bracket on bow.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 April 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 March 2009 Resolved
Properly seal holes in bulkhead. (Old raft bracket)
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 April 2009
Construction/Loadline › Structures › Door
Issued 19 March 2009 Resolved
Make repairs to emergency escape hatch
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 April 2009
Engineering › Bilge Water Management System › Valve
Issued 19 March 2009 Resolved
Provide check valves for overboard bilge discharge (04).
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 6 April 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 March 2009 Resolved
Seal two through holes from port side engine room and one starboard side engine room to fuel tank space.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 6 April 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 19 March 2009 Resolved
Make bulkhead between engine room and lazzerat water tight.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 6 April 2009
Engineering › Steering Gear System › Rudder Bearing
Issued 19 March 2009 Resolved
Properly addres issues with port rudder bearing
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 April 2009
Lifesaving › Hand Flares › Not on Board
Issued 25 August 2008 Resolved
Provide 01 Flares.
Condition: Improper/Lack of Maintenance
Due 8 September 2008
Resolved 8 September 2008
Fire Fighting › Fire Bucket › Availability
Issued 25 August 2008 Resolved
Provide 03 fire buckets labeled with lanyards.
Condition: Improper/Lack of Maintenance
Due 8 September 2008
Resolved 8 September 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 August 2008 Resolved
Provide covers for battery cases.
Condition: Unknown
Due 8 September 2008
Resolved 8 September 2008
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 25 August 2008 Resolved
Provide a non combustible waste receptacle.
Condition: Unknown
Due 8 September 2008
Resolved 8 September 2008
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 25 August 2008 Resolved
Remove halon bottle from engine room.
Condition: Improper/Lack of Maintenance
Due 8 September 2008
Resolved 8 September 2008
Documentation › Markings/Placards › Warning Signs
Issued 25 August 2008 Resolved
Provide marking for emg. escape hatch.
Condition: Unknown
Due 8 September 2008
Resolved 8 September 2008
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 25 August 2008 Resolved
Conduct satisfactory man over board drill.
Condition: Unknown
Due 8 September 2008
Resolved 8 September 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 25 August 2008 Resolved
Ensure escape hatch is free and clear.
Condition: Unknown
Due 8 September 2008
Resolved 8 September 2008
Stability › Severe Wind/Roll › General
Issued 3 June 2008 Resolved
Vessel must either remove the top/canopy or submit stability calculations to MSC for review and approval prior to carrying passengers for hire.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2008
Resolution: Canopy has been removed. Vessel is operating within COI requirements.
Construction/Loadline › Hull › Side Shell
Issued 17 April 2008 Resolved
Repair 10 blisters in starboard side and 13 blisters in port side shells.
Condition: Improper/Lack of Maintenance
Due 30 April 2008
Resolved 22 April 2008
Resolution: Blisters ground out and re epoxied.
Construction/Loadline › Hull › Side Shell
Issued 17 April 2008 Resolved
Repair crack and soft spot in stbd bow.
Condition: Improper/Lack of Maintenance
Due 30 April 2008
Resolved 22 April 2008
Resolution: Crack and soft spot ground out, repaired and re epoxied.
Engineering › Sea-water System (primary cooling) › Valve
Issued 17 April 2008 Resolved
Make all thru-hull fitting available for inspection.
Condition: Placed in Improper Service
Due 30 April 2008
Resolved 22 April 2008
Resolution: All thru hull fitting inspected and found in good condition.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 12 February 2007 Resolved
Ensure sufficient repairs made to stbd. shaft and prove proper operation of propulsion machinery in supervised sea trial.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2007
Resolution: Made necessary repairs, conducted satisfactory sea trial.
Engineering › Bilge Water Management System › Pump
Issued 8 May 2006 Resolved
Forward bilge pump would not work
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2006
Resolution: Bilge pump was repaired
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 May 2006 Resolved
Bilge high water alarms were labeled incorrectly so that the wrong compartment alarm indicators would sound.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2006
Resolution: Alarm indicators were relabled.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 8 May 2006 Resolved
Stbd. engine room vent would not close.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2006
Resolution: Vent closure controls were repaired/serviced.
Documentation › Markings/Placards › Warning Signs
Issued 8 May 2006 Resolved
Vsl must remove 'emergency exit' sign for forward salon hatch that is now blocked.
Condition: Improper Installation
Due 8 June 2006
Resolved 10 August 2006
Resolution: Painted over unnecessary markings
Engineering › Bilge Water Management System › Pump
Issued 8 May 2006 Resolved
Prove proper operation of manual bilge pump switches
Condition: Improper Installation
Due 8 June 2006
Resolved 10 August 2006
Resolution: Displayed proper operation of bilge pump and switches.
Engineering › Steering Gear System › Fastener
Issued 30 March 2006 Resolved
Install safety nut/pin on rudder top post.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2006
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 30 March 2006 Resolved
Holes in bulkheads from added or removed wire runs.
Condition: Unknown
Due 17 April 2006
Resolved 10 August 2006
Resolution: Sealed all thruholes in watertight bulkheads.
Construction/Loadline › Structures › Superstructure
Issued 30 March 2006 Resolved
Bimini top on flying bridge.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2006
Resolution: Bimini top removed to comply with issued stability letter.
Electrical › Lighting (service) › Conductor
Issued 30 March 2006 Resolved
Missing metal supports every 24".
Condition: Unknown
Due 17 April 2006
Resolved 10 August 2006
Resolution: Installed wiring supports accordingly
Fire Fighting › Fixed Halon Fire Extinguishing System › Quantity of Halon
Issued 2 June 2005 Resolved
Vessel required 500 cubic feet capacity halon. The current Fixed system had only 425 cubic feet capacity.
Due 13 June 2005
Resolved 2 June 2005
Resolution: Replaced with 500 cubic foot capacity FE 241 bottle.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 2 June 2005 Resolved
Lettering was peeling off.
Due 13 June 2005
Resolved 2 June 2005
Resolution: Replaced old lettering with new.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 2 June 2005 Resolved
Vessel had (2) PFD's in non-compliance.
Due 13 June 2005
Resolved 2 June 2005
Resolution: Purchased (2) CG approved adult PFD''s
Engineering › Fuel Oil Service System › Valve
Issued 2 June 2005 Resolved
Provide labels for fuel shutoffs
Due 13 June 2005
Resolved 2 June 2005
Resolution: Labeled fuel shutoffs
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 June 2005 Resolved
Steering void high water alarm not functioning properly, mounted to high.
Condition: Improper/Lack of Maintenance
Due 13 June 2005
Resolved 2 June 2005
Resolution: Repaired high water alarm to function properly, mounted at satisfactory level.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 2 June 2005 Resolved
Did not have 2nd anchor on board
Due 13 June 2005
Resolved 2 June 2005
Resolution: Purchased and installed 2nd anchor
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 June 2005 Resolved
Eyewash Expired
Due 13 June 2005
Resolved 2 June 2005
Resolution: Purchased new eye wash for first aid kit
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 June 2005 Resolved
Exposed wiring in aft steering void.
Condition: Improper Installation
Due 13 June 2005
Resolved 2 June 2005
Resolution: properly fitted wiring with no exposed ends.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 May 2004 Resolved
Waterlight not working
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2004
Resolution: New light installed
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 May 2004 Resolved
PFD donning placard missing
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2004
Resolution: Placard mounted
Stability › Watertight Integrity
Issued 23 February 2004 Resolved
E/R and Steering room hatch cover gaskets wasted.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 23 March 2004
Resolution: Replaced gaskets
Electrical › Electrical Distribution System (service)
Issued 23 February 2004 Resolved
Electrical wiring missing metal supports at the 24" intervals throughout vessel. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 23 March 2004
Operations/Management › Navigation Safety
Issued 23 February 2004 Resolved
Provide anchor for inspection. LEGACY COMPONENT DESC: Navigation Underway, General
Action required: 705 - Other - as specified
Resolved 23 March 2004
Electrical › Electrical Distribution System (service)
Issued 23 February 2004 Resolved
Dead end wiring in forepeak. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Resolved 23 March 2004
Resolution: Wiring terminated in junction box.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 23 February 2004 Resolved
Mark escape hatch in foreward accommodation space - "Emergency Exit, Keep Clear".
Action required: 705 - Other - as specified
Resolved 23 March 2004
Lifesaving
Issued 29 April 2003 Resolved
Install proper donning placard for lifejackets (two types) or install same type of lifejacket throughout vsl.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 May 2003
Resolved 20 May 2003
Resolution: Owner faxed in a statement attesting to the correction of the following items.
Communications › Radio Communications › EPIRB
Issued 29 April 2003 Resolved
Properly install a satisfactory EPIRB and prove proper operation with valid registration information.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 May 2003
Resolved 20 May 2003
Resolution: Owner faxed in a statement attesting to the correction of the following items.
Accommodation/Occupational Safety › Medical/First Aid
Issued 29 April 2003 Resolved
Replace expired aspirin bottle with up to date aspirins.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2003
Resolved 20 May 2003
Resolution: Owner faxed in a statement attesting to the correction of the following items.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 April 2003 Resolved
Prove proper operation of high bilge alarm in lazerette.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 May 2003
Resolved 20 May 2003
Resolution: Owner faxed in a statement attesting to the correction of the following items.
Accommodation/Occupational Safety › Occupational Safety
Issued 1 February 2002 Resolved
Need to install additional rail courses in rail sections on port & stbd sides adjacent to wheelhouse to attain proper spacing interval. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 June 2002
Resolved 6 May 2002
Accommodation/Occupational Safety › Washroom/Toilet
Issued 1 February 2002 Resolved
Properly refiberglass and mount sewage holding tank. LEGACY COMPONENT DESC: Toilet
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 June 2002
Resolved 6 May 2002
Construction/Loadline › Structures
Issued 1 February 2002 Resolved
Properly seal all wire runs going through forward engine room bulkhead. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 June 2002
Resolved 6 May 2002
Construction/Loadline
Issued 4 June 2001 Resolved
SEPERATE VISUAL HIGH LEVEL BILGE ALARM DETECTION LIGHT AT OPERATING STATION(LAZARET, ENGINE ROOM, FWD SPACE).
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Fire Fighting
Issued 4 June 2001 Resolved
PROVIDE PROOF OF PORTABLE AND FIXED FIRE EXTINGUISHING SYSTEM SERVICING.
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Navigation
Issued 4 June 2001 Resolved
PROPERLY REPAIR STERN LIGHT.
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Documentation
Issued 1 April 2001 Resolved
Provide proof that Owner/Operator and vessel's name has been changed on theCertificate of Documentation.
Condition: Unknown
Due 15 May 2001
Resolved 19 April 2001
Engineering
Issued 13 June 2000 Resolved
TESTING OF INDEPENDANT FUEL TANKS IAW 46 CFR 182.440 (c) TO BE COMPLETED NLT 28FEB01.
Condition: Unknown
Due 13 June 2000
Resolved 13 June 2000

Casualty record · 1

3 October 2006Routine · role: Involved in a Marine Casualty · activity 2798471
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

BLUE WATER EXPRESS (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.