MAURY USCG vessel records Sign in
← All vessels

MOCHA

MOCHA is a 1968 passenger vessel (inspected). The Coast Guard has recorded 52 inspections since 1990, most recently in May 2025, along with 48 deficiencies.

Records from 1990 to 2025. Most recent: inspection, 14 May 2025.

Built
1968
Last inspected
14 May 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF7872
346074
Flag
UNITED STATES
—
Maury page id
psix-346074

Inspections, by type

…with no type recorded3
Years with a record 31 calendar years (1990–2025)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 52

14 May 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8136087
30 April 2025 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8126654
29 April 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7903471
5 May 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7681916
12 May 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7448410
6 September 2021 Type not recorded
No type recorded · USCGC WAHOO (WPB 87345) · USCG Northwest District (CGD-NW) · Activity 7309731
6 May 2021 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7190891
4 August 2020 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7020145
19 August 2019 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6788611
22 July 2019 Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6758569
18 June 2018 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6448673
17 May 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6146938
12 May 2016 Administrative Inspection · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5867704
17 June 2014 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4890585
11 May 2012 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4301928
15 July 2009 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3536303
13 August 2008 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3299027
8 April 2008 Hull Examination · Simplified Stability Test · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3179714
29 January 2008 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3138517
3 May 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2921629
17 July 2006 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2715811
12 May 2006 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2647352
23 March 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2608231
17 June 2005 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2393365
9 May 2005 COI Inspection · Plan Review "T" Boat
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2353254
30 July 2004 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2150284
9 June 2004 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2093215
20 May 2004 Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2073912
19 April 2004 Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2047883
9 May 2003 Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1790131
30 April 2002 Re-Inspection · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1611178
10 April 2002 Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1604010
17 May 2001 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1431039
18 May 2000 Plan Review "T" Boat · COI Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1471013
18 November 1999 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 813660
11 October 1999 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 813658
12 March 1999 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1453556
21 April 1998 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1471994
22 October 1997 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1457516
2 May 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1394813
15 March 1996 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1078930
7 November 1995 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1185524
3 May 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 872151
15 March 1995 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 835429
14 March 1994 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 855436
13 August 1992 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1268218
23 March 1992 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 945428
23 March 1992 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1148693
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1310102
1 May 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1212328
26 October 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 920476
21 March 1990 Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 908954

Deficiency record · 48

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 May 2025 Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Fuel shutoff valve is inoperable. Unable to shut off engine when handles is pulled. Attempted multiple times during inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2025
Resolution: revieved video of fuel shutoff working properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2023 Resolved
46 CFR 182.20-40 (Old T): The discharge end of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. No flame screen present at discharge end of fuel vent pipe (serves both diesel tanks).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2023
Resolved 9 May 2023
Resolution: Operator submitted photos of satisfactory installation of flame screen for fuel tank vent.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 May 2021 Resolved
Vessel did not have a valid FCC Station License. Certificate expired on 06MAY2021. Vessel must have valid Station License. 47 CFR 80.13
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 24 May 2021
Resolution: New cert.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 12 May 2021 Resolved
Several items were found to be expired in first aid kit. Replace with non expired items. 46 CFR 184.710
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 24 May 2021
Resolution: New items acquired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 August 2020 Resolved
Number and sizes of lifejackets must be labeled on the container. Lifejacket stowage does not have sized and amount. Properly labe lifejackets stowed.
Action required: 10 - Deficiency Rectified
Due 19 August 2020
Resolved 10 August 2020
Resolution: Operator properly labeled lifejacket stowage.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 August 2020 Resolved
Donning instructions for lifejackets must be posted. Post proper instructions.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 19 August 2020
Resolved 10 August 2020
Resolution: Operator posted lifejacket donning instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 4 August 2020 Resolved
Vessel must carry one floating light. Floating light inoperable, must be repaird. vessel restricted to daylight operations and full visibility.
Action required: 10 - Deficiency Rectified
Due 26 August 2020
Resolved 14 August 2020
Resolution: Operator purchase new float light and provided photo evidence
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 August 2020 Resolved
All vessels must have navigation lights in compliance with navigation rules. Vessel has inoperable navigation light. Restricted to daylight operations and visibility.
Action required: 10 - Deficiency Rectified
Due 26 August 2020
Resolved 18 August 2020
Resolution: Navigation light have been repaired, provided photo evidence
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 July 2019 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Rectify deficiency prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2019
Resolved 31 July 2019
Resolution: Witnessed functional test of bilge alarms both audio and visual.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 24 July 2019 Resolved
VHF radio not functioning. Repair or replace prior to carrying passengers IAW 47 CFR 80.901.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2019
Resolved 31 July 2019
Resolution: Radio was replaced and witnessed satisfactory radio check
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 July 2019 Resolved
Provide this office with proof of an updated FCC station license IAW 47 CFR 80.25.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 31 July 2019
Resolution: Verified new FCC Station license
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 24 July 2019 Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Provide this office with proof of fixed CO2 servicing certificate IAW 46 CFR 176.25-25.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 31 July 2019
Resolution: Verified certification of fixed CO2 system
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 July 2019 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Passenger count is reduced to 13 until the damaged life jacket identified is replaced IAW 46 CFR 180.25-5.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 31 July 2019
Resolution: Inspected life jackets. 15 adult and 4 child lifejackets onboard
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 July 2019 Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life jacket.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 31 July 2019
Resolution: Verified proper marking on all lifejackets
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 July 2019 Resolved
Batteries shall be located as high above the bilg as practicable and secured against shifting with motion of the boat. Install securing device for battery IAW 46 CFR 183.05-20 (b).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 31 July 2019
Resolution: Witnessed that battery is properly strapped in a battery box
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 24 July 2019 Resolved
Remove expired first-aid items and ensure that first aid kit meets the requirements of 46 CFR 160.041. (List provided separately)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 31 July 2019
Resolution: Witnessed that all expired items in first aid kit have been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 24 July 2019 Resolved
Remove or replace any expired distress flares IAW 46 CFR 180.35 (a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 31 July 2019
Resolution: Witnessed that all expired distress signals have been replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 July 2019 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 31 July 2019
Resolution: Witnessed that vessel is equipped with 02 battery operated flashlights
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 24 July 2019 Resolved
Demonstrate effective use of rescue ladder in the event of that a person needs to be rescued from going overboard.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 August 2019
Resolved 31 July 2019
Resolution: While underway witnessed vessel master properly set up rescue ladder and explain recovery procedures for a person in the water.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 July 2019 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel is restricted to daytime operation until all navigation lights are functioning properly.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 August 2019
Resolved 12 August 2019
Resolution: Vessel owner showed repaired lights on a photograph.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 July 2019 Resolved
Unless otherwise specified, vessel owners must pay the fees required by this subpart before inspection or examination services are provided. User fees must be paid prior to operating under the vessel's COI. As per the vessel's COI your vessel may continue to operate as an Uninspected Passenger Vessel or Recreational vessel IAW 46 CFR 2.10-20.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 August 2019
Resolved 24 July 2019
Resolution: User fees paid.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 17 June 2014 Resolved
Vessel shall have FCC Saftey survey by FCC inspector. Send copy of FCC Safety Cert. to the attending Marine Inspector. 47 CFR 80. 02JUL14
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 2 July 2014
Resolution: FCC survey was complete and inspector received a copy of FCC Safety Cert.
Fire Fighting › Fire Bucket › Stenciling
Issued 17 June 2014 Resolved
Vessel shall label fire bucket to the satisfaction of the attending Marine Inspector. 46 CFR 181.610 02JUL14
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 2 July 2014
Resolution: Vessel master labeled folding fire bucket.
Fire Fighting › Fire Bucket › Quantity
Issued 17 June 2014 Resolved
Vessel shall have three 2.5 gallon fire buckets, each with a lanyard, onboard to the satisfaction of the attending Marine Inspector. 46 CFR 181.610 02JUL14
Action required: 705 - Other - as specified
Due 2 July 2014
Resolved 2 July 2014
Resolution: Vessel master installed two additional fire buckets.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 11 May 2012 Resolved
The portable container for the flares and day smokes was not watertight. Asked owner to get new watertight and properly labeled container.
Due 11 June 2012
Resolved 22 May 2012
Resolution: Vessel obtained watertight container.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 May 2012 Resolved
The fixed CO2 firefighting system did not have satisfactory evidence of the required servicing.
Due 11 June 2012
Resolved 22 May 2012
Resolution: Received CO2 firefighting servicing certificates.
Stability › Incline Test › General
Issued 8 April 2008 Resolved
Vessel limited to 12 POB due to SST conducted 7/30/08
Action required: 705 - Other - as specified
Due 15 August 2008
Resolved 13 August 2008
Resolution: Issued signed stability letter and amended COI.
Stability › Incline Test › General
Issued 29 January 2008 Resolved
Vessel required to complete simplified stability test prior to next drydock.
Due 31 March 2008
Resolved 30 July 2008
Resolution: Conducted SST
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 3 May 2007 Resolved
Conduct MOB drill with USCG.
Due 1 June 2007
Resolved 8 May 2007
Resolution: SAT drill by crew.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 May 2007 Resolved
Replace waterlight.
Due 1 June 2007
Resolved 8 May 2007
Resolution: New waterlight.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 May 2005 Resolved
The eye wash in the first aid kit was expired.
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 13 May 2005
Navigation › Piloting/Steering › Marine Charts
Issued 9 May 2005 Resolved
Chart for the area of operation was out of date.
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 13 May 2005
Accommodation/Occupational Safety › Medical/First Aid
Issued 20 May 2004 Resolved
Replace expired medications in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 1 June 2004
Resolved 9 June 2004
Resolution: Complete.
Documentation › Markings/Placards
Issued 20 May 2004 Resolved
post marpol (oil pollution) placard LEGACY COMPONENT DESC: Oil Discharge Placard
Due 1 June 2004
Resolved 9 June 2004
Resolution: Complete.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 9 May 2003 Resolved
Prove current servicing of portable fire extinguishers prior to operating with passengers. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 10 May 2003
Resolved 16 May 2003
Resolution: Rcvd servicing receipt from O/O.
Lifesaving › Visual Distress Signals (General)
Issued 9 May 2003 Resolved
Provide three orange smoke distress signals. LEGACY COMPONENT DESC: Quantity
Condition: Unknown
Due 23 May 2003
Resolved 12 May 2003
Resolution: Rcvd copy of receipt of purchase.
Lifesaving › Lifebuoys
Issued 9 May 2003 Resolved
Apply Type II retroreflective tape to both sides of ring buoy. LEGACY COMPONENT DESC: Markings (retro)
Condition: Placed in Improper Service
Due 23 May 2003
Resolved 12 May 2003
Resolution: Rcvd fax confirmation from O/O indicating compliance.
Accommodation/Occupational Safety › Medical/First Aid
Issued 9 May 2003 Resolved
Provide splint and renew expired medications in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 23 May 2003
Resolved 12 May 2003
Resolution: Received copy of receipt of purchase.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 30 April 2002 Resolved
Perform and log annual maintenance for portable fire extinguishers.
Due 14 May 2002
Resolved 15 May 2002
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 30 April 2002 Resolved
Provide approved bracket for the portable extinguisher mounted on the aft bulkhead. LEGACY COMPONENT DESC: Mounting Bracket
Due 15 May 2002
Resolved 15 May 2002
Lifesaving › Lifejacket/PFD (General)
Issued 30 April 2002 Resolved
Replace worn retro tape on lifejackets as needed. LEGACY COMPONENT DESC: Retroreflective Material
Due 14 May 2002
Resolved 15 May 2002
Lifesaving › Lifebuoys
Issued 30 April 2002 Resolved
Replace or repair water light. LEGACY COMPONENT DESC: Self-igniting Lights
Due 14 May 2002
Resolved 15 May 2002
Documentation
Issued 17 May 2001 Resolved
Obtain radio Operator's license
Condition: Unknown
Due 17 July 2001
Resolved 11 June 2001
Navigation
Issued 17 May 2001 Resolved
Prove proper operation of VHF-FM radio
Condition: Unknown
Due 24 May 2001
Resolved 11 June 2001
Documentation
Issued 17 May 2001 Resolved
Obtaiin safety radio certificate
Condition: Unknown
Due 17 July 2001
Resolved 11 June 2001
Lifesaving
Issued 15 March 1995 Resolved
Repair and prove operation of ringbuoy waterlight.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Lifesaving
Issued 15 March 1995 Resolved
Provide 3 additional red flares.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Documentation
Issued 21 March 1990 Resolved
PROVIDE A COPY OF THE FCC RADIOTELEPHONY LICENSE. VESSEL IS RESTRICTED TO ROUTE OF NO MORE THAN 1000' FROM SHORE UNTIL LICENSE OBTAINED.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.