MAURY USCG vessel records Sign in
← All vessels

OSPREY

OSPREY is a 1989 freight ship. The Coast Guard has recorded 19 inspections since 1990, most recently in January 2026, along with 12 deficiencies and 3 operational controls.

Records from 1990 to 2026. Most recent: inspection, 7 January 2026.

Built
1989
Last inspected
7 January 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8616568 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
346077
Flag
NORWAY
—
Maury page id
psix-346077

Inspections, by type

…with no type recorded5
Years with a record 12 calendar years (1990–2026)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11617 - Convention (Subpart B), Net Ton
75356 - Displacement, Ton
52553 - Dead Weight, Ton
38722 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

7 January 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8292006
12 October 2018 Ballast Water Examination · PII Safety Exam · COE-Dockside · ISPS III Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6555805
22 November 2017 Ballast Water Examination · PI Safety Exam · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6316043
21 July 2017 Administrative Inspection
Administrative · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6213090
2 March 2016 PI Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5820993
13 September 2011 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4141428
21 July 2009 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3541371
11 March 2009 Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3430198
2 December 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3361558
17 October 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3346789
7 October 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3339719
28 April 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 427956
3 May 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 415846
3 May 1998 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1125477
4 May 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 366791
4 May 1994 Tank Vessel Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428336
26 May 1991 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1207014
31 December 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 518008
25 March 1990 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1232108

Deficiency record · 12

Engineering › Lubricating Oil Service System › Piping
Issued 13 September 2011 Resolved
Ship's Service Diesel Generator has excessive oil leakage presenting fire hazard. Sample connection on inboard SSDG was smashed, sealing connection off. Manning platforms on #1 and #2 SSDG's are not stable, creating unsafe work condition. SOLAS 74 (2001) Ch: II-1, Regulation 26.1. Correct to the satisfaction of U.S. Coast Guard and the vessel Class Society.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 September 2011
Resolution: Sample connection on inboard SSDG was replaced and found to be in good working order. The Ship Service Diesel Generators #1 and #2 were tested under load and no further leaks observed. Manning platforms secured with additional brackets and supports.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 11 March 2009 Resolved
On 10MAR2009 The vessel lost propulsion while attempting to sail from Corpus Christi, Tx the vessel was required to have a class surveyor attend to attest to the satisfactory operation of the propulsion plant.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 March 2009
Resolution: Received class report attesting to the repairs and the satisfactory operation of the main propulsion plant.
Communications › Radio Communications › Emergency Source of Power
Issued 7 October 2008 Resolved
Batteries for radio equipment on forward bridge are flooded and releasing fumes. New batteries must be provided for radio equipment.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 December 2008
Resolution: New batteries were provided for the radio equipment on the forward bridge.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 October 2008 Resolved
Light above fresh water well tank is being covered by a plastic bag. Light cover must be provided that is suitable for machinery space.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 December 2008
Resolution: Missing light cover provided.
Engineering › Feedwater/Condensate Water System › Observation Tank
Issued 7 October 2008 Resolved
Sight Glasses on fresh water well tank are cracked and leaking steam.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 December 2008
Resolution: Glasses were removed and temporarily repaired by fitting the blank.
Engineering › Freshwater Generation System › Valve, Dump
Issued 7 October 2008 Resolved
Valve is leaking steam and water on the fresh water generator. Water then leaks through the deck onto a light creating an electrical hazard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 December 2008
Resolution: The valve is repaired with a function test carried out.
Fire Fighting › Fire Pumps › Impeller
Issued 7 October 2008 Resolved
Fire pump has a constant leak. When started the fire pump has a forceful stream into the bilges creating a flooding hazard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 October 2008
Resolution: The Fire pump was overhauled and defective mechanical seal was replaced. Recieve report from Class stating that it was in working order.
Fire Fighting › Automatic Sprinkler System › Connection to Fire Main
Issued 28 April 1999 Resolved
SPECIFIC CITE: SOLAS 74(AMENDED) I 11.0_x001C_ ALL MAIN DECK FOAM MONITORS LEAKING. VESSEL TO OVERHAUL ALL FOAM MONITORSTO THE SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 30 April 1999
Resolved 7 October 2008
Deck/Cargo
Issued 28 April 1999 Resolved
SPECIFIC CITE: SOLAS 74 (AMENDED) II-1/45.5.2_x001C_ IMPROPER WIRE CONNECTION ON HIGH TEMPERATURE SENSOR #1 IG FAN. VESSEL CORRECTED CONNECTION ON THE SPOT PRIOR TO CARGO OPERATIONS.
Condition: Unknown
Due 29 April 1999
Resolved 30 April 1999
Deck/Cargo
Issued 28 April 1999 Resolved
SPECIFIC CITE: SOLAS 74 (AMENDED) II-1 45.5.2_x001C_ IMPROPER WIRE ON HIGH TEMP SENSOR #2 IG FAN. VESSEL REPLACED WIRE ON #2 IGFAN TEMPERATURE SENSOR PRIOR TO CONDUCTING CARGE OPS.
Condition: Unknown
Due 29 April 1999
Resolved 30 April 1999
Lifesaving › Buoyant Apparatus › Approval
Issued 28 April 1999 Resolved
SPECIFIC CITE: SOLAS 74 (AMENDED) II-2/11.5_x001C_ WORN GASKET ON VENT CLOSURE TO SEPERATOR ROOM. VESSEL TO RPLACE GASKET PRIOR TO NEXT US PORT.
Condition: Unknown
Due 30 April 1999
Resolved 7 October 2008
Fire Fighting
Issued 3 May 1998 Resolved
HAVE ALL F/F SYSTEMS INSPECTED BY 3RD PARTY PRIOR TO NEXT ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 30 April 1999
Resolved 30 April 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.