Records from 1998 to 2026. Most recent: inspection, 28 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 41
28 April 2026
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8357761
21 January 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8299189
16 July 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8190938
27 March 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8108913
28 February 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8086180
18 July 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7963928
18 August 2023
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7771456
27 June 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7727244
12 May 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7686931
9 August 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7528940
25 January 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7388384
15 January 2021
In-Service Inspection · COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7125329
6 August 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7067503
23 July 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6755010
15 January 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6610029
17 July 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6482318
2 August 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6227686
18 March 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5835950
3 March 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5827054
20 July 2015
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5187115
20 August 2014
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4962194
22 August 2011
Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4123752
3 August 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4104403
10 March 2010
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3693393
13 August 2008
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3297226
14 March 2007
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2888514
22 May 2006
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2608413
23 August 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2471852
4 August 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2221509
16 March 2004
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2033488
14 May 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1786754
14 May 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1791634
14 May 2002
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1667277
31 May 2001
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1458000
11 April 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1074512
27 March 2001
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1449523
24 May 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1393468
20 May 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1098281
17 August 1998
Construction Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1404597
1 June 1998
Initial Certification · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1436135
8 January 1998
Initial Construction-Excluding Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1411595
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 April 2026
Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Engine room has two areas (under stbd operation station and port side amidships where there are no gas tight with no closures.
46CFR181.20-35
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 April 2026
Resolution: Received photos of the opening being closed up with metal covers. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2026
Resolved
At each initial and subsequent inspection for certification and reinspection the marine inspector shall examine and test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and that it is fit for the service intended. Rudder packing has a slow weep while operating.
46CFR176.25-35
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 May 2026
Resolution: Video evidence received of rudder post not leaking. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 April 2026
No resolution recorded
The intent of this part is to insure that each vessel
carry sufficient lifesaving equipment to provide for
timely rescue and survival of the personnel on board.
The on board life float has multiple areas of
delamination and the incorrect vessel name on it.
46CFR180.01-5
Action required: 50 - Rectify deficiencies w/in 30 days
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 April 2026
Resolved
As appropriate for the intended voyage,all vessels must carry adequate and up-to-date-(a) Charts;(b) Sailing directions;(c) Coast pilots;(d) Light lists. Light list and Coast Pilot were not current.
46CFR185.20-35
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 May 2026
Resolution: Photo received of pubs beign on board. All sat.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 28 April 2026
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. VHF radio did not have the vessels MMSI number programmed in it.
46CFR184.502
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 May 2026
Resolution: Received photo of MMSI number being programmed into radio. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 February 2025
Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. Vessel failed to complete required drydock exam by the due date of 31 January 2025.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2025
Resolved 28 March 2025
Resolution: Completed drydock exam
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 June 2023
Resolved
Each life preserver carried on a vessel after June 30, 1980, must have at least 200 sq. cm (31 sq. in.) of retroreflective material attached on its front side, at least 200 sq. cm on its back side, and at least 200 sq. cm of material on each of its reversible sides. The retroreflective material on the (22) adult life preservers were faded and unserviceable. Replace with approved SOLAS Type A retroreflective tape prior to carrying passengers.
705c (Prior to carrying passengers)
46 CFR 180.25-25
"Old T"
Action required: 705 - Other - as specified
Due 30 June 2023
Resolved 16 August 2023
Resolution: Received photos of all life preservers lined up with new retro applied. Accepted as substantial evidence for compliance. Photo is uploaded in the Deficiency History - Documents tab as "Aug2023 Defcheck PFD retro."
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 June 2023
Resolved
Each water light must be of an approved automatic electric type, constructed in accordance with subpart 161.010 of this chapter, except as allowed under paragraph (c) of this section. The water light on the ring life buoy was not operable. Replace with an approved type battery or replace the unit prior to carrying passengers.
705c (Prior to carrying passengers)
46 CFR 180.30-1(b)
"Old T"
Action required: 705 - Other - as specified
Due 30 June 2023
Resolved 18 August 2023
Resolution: Operator submitted documentation of purchased battery which was compliant with light. Light worked on scene but had unapproved type battery and this was taken as objective evidence. Photo of battery in Deficiency History- Documents tab.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 27 June 2023
Resolved
Medical certificates issued to all mariners will be issued for a maximum of 5 years. The masters medical certificate was expired. Provide a copy of the renewed medical certificate.
50c
46 CFR 10.301(b)(3)
Due 26 July 2023
Resolved 17 September 2023
Resolution: Certificates verified by CG Marine Inspector
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 August 2022
Resolved
46 CFR 67.7 - Any vessel of at least five net tons which engages in coastwise trade, unless exempt under 67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel did not have a valid Certificate of Documentation.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 August 2022
Resolution: Verified vessel has valid COD. New experation is 31AUG23.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 9 August 2022
Resolved
46 CFR 67.117(c) - The name of a vessel must not be changed without prior approval of the Director, National Vessel Documentation Center. Vessel owner attempted to change vessels name without proper approval and now vessels documentation and equipment markings are inaccurate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2023
Resolution: Verifed vessel has updated all documentation and equipment with accurate information.
Engineering › Steering Gear System › Hydraulic Hose
Issued 3 March 2016
Resolved
Hydraulic connection aft of engine box wasted, Replace and comply with SAE-J1942 (Hose) and SAE 1528 (Connection).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 14 April 2016
Resolution: New hoses installed and verified by attending MI.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 3 March 2016
Resolved
Fuel lines in steering compartment connections wasted. Repair/Replace and comply with SAE-J1942 (Hose) and SAE 1528 (connections).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 14 April 2016
Resolution: Installed and verified by attendign MI.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 20 August 2014
Resolved
Upon inspection of vessel it was found they were missing one B-I fire Extinguisher located in the vicinity of the Operating Station as required in 46 CFR 181.500 table.
Due 3 September 2014
Resolved 4 September 2014
Resolution: Vessel owner/Operator provided receipt of puirchase of (01) B-1 Portable Fire Extinguisher.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 22 August 2011
Resolved
Vessel suffered lighting strike on 21 Aug 2011 causing the engine electronics to fail. Determine cause of failure. Repair as new . In accordance with 46 CFR 182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2011
Resolved 8 September 2011
Resolution: Attended vessel at Cambridge, Md. to inspect repairs to engine and navigation equipment caused by a lighting strike. All equipment and main diesel engine operated properly.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 13 August 2008
Resolved
Provide permanent repairs for throttle assembly bracket.
Condition: Improper/Lack of Maintenance
Due 12 September 2008
Resolved 11 September 2008
Resolution: Throttle assembly welded.
Lifesaving › Lifefloat › Paddle
Issued 13 August 2008
Resolved
Provide additional oar for the lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2008
Resolved 11 September 2008
Resolution: Oar procured and installed in lifefloat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 August 2008
Resolved
Install stern light as prescribed in the Navigation Rules, Rule 23 (iv).
Condition: Placed in Improper Service
Due 12 September 2008
Resolved 11 September 2008
Resolution: Sternlight installedas per Nav Rule 23.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 August 2008
Resolved
Provide hard copies for the tides and currents tables as required in 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Due 12 September 2008
Resolved 11 September 2008
Resolution: Hard copies of the tide and currets tables placed onboard vessel.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 23 August 2005
Resolved
Fire extinguisher was not mounted in a bracket.
Due 23 September 2005
Resolved 26 September 2005
Resolution: Mounted fire extinguisher. Notified OCMI by email of correction on 26 Sep 2005.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 23 August 2005
Resolved
VDS were located in unmarked plastic box with other materials. Instructed to place VDS in separate container labeled "FLARES".
Due 23 September 2005
Resolved 26 September 2005
Resolution: Corrected discrepancy. Notified OCMI by email of correction on 26 Sep 2005.
Engineering › Bilge Water Management System › Pump
Issued 23 August 2005
Resolved
Broken wire on bilge pump switch
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2005
Resolution: Corrected discrepancy, notifed OCMI by email of correction on 26 Sep 2005.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 14 May 2003
Resolved
Prior to carrying passengers, service one portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2003
Accommodation/Occupational Safety
Issued 31 May 2001
Resolved
REPAIR LINE FROM TOILET TO HOLDING TANK PRIOR TO USING TOILET._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 June 2001
Resolved 5 October 2001
Navigation
Issued 31 May 2001
Resolved
REPAIR RUNNING LIGHT PRIOR TO OPERATING AT NIGHT.
Condition: Unknown
Due 30 June 2001
Resolved 5 October 2001
Lifesaving
Issued 31 May 2001
Resolved
PROPERLY MARK LIFE FLOAT & PADDLES W/ VSL NAME & MARK LIFE FLOAT W/CAPACITYOF PASSENGERS PRIOR TO CARRIAGE OF PASSENGERS OR REMOVE FOR REMAINDER PF WARM WATER MONTHS.
Condition: Unknown
Due 30 June 2001
Resolved 5 October 2001
Lifesaving
Issued 31 May 2001
Resolved
PROVIDE WATER LIGHT FOR LIFE FLOAT.
Condition: Unknown
Due 30 June 2001
Resolved 5 October 2001
Lifesaving
Issued 31 May 2001
Resolved
PATCH RING BUOY.
Condition: Unknown
Due 30 June 2001
Resolved 5 October 2001
Documentation
Issued 31 May 2001
Resolved
PROVIDE FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 30 June 2001
Resolved 5 October 2001
Construction/Loadline
Issued 31 May 2001
Resolved
REPAIR HIGH WATER BILGE ALARM IN ENGINE COMPARTMENT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 30 June 2001
Resolved 5 October 2001
Navigation
Issued 24 May 2000
Resolved
PROVIDE BELL OF PROPER SIZE
Condition: Unknown
Due 24 June 2000
Resolved 29 June 2000
Electrical
Issued 24 May 2000
Resolved
PROVIDE SUITABLE MARINE LIGHTING GUARD OR LIGHT FOR CABIN AND V-BERTH LIGHTS.
Condition: Unknown
Due 24 June 2000
Resolved 29 June 2000
Documentation
Issued 24 May 2000
Resolved
PROVIDE PROOF OF VSL DOCUMENTATION
Condition: Unknown
Due 24 June 2000
Resolved 29 June 2000
Construction/Loadline
Issued 20 May 1999
Resolved
Hatch in collision bulkhead must be in place at all times when carrying passengers
Condition: Unknown
Due 2 June 1999
Resolved 4 November 1999
Construction/Loadline
Issued 20 May 1999
Resolved
Provide cap for unused through-hull fitting.
Condition: Unknown
Due 2 June 1999
Resolved 4 November 1999
Unknown
Issued 20 May 1999
Resolved
Provide stability information or conduct simplified stability proof test.
Condition: Unknown
Due 20 May 1999
Resolved 20 May 1999