MAURY USCG vessel records
← All vessels

ORION

ORION is a 2001 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in April 2026, along with 15 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 17 April 2026.

Built
2001
Last inspected
17 April 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDM6425
Flag
UNITED STATES
Maury page id
psix-34639

Inspections, by type

Years with a record 11 calendar years (2016–2026)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 15

17 April 2026 COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8349548
18 March 2025 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087822
4 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087833
23 April 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7891772
30 March 2023 Deficiency Check · Administrative Inspection · Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7644655
16 March 2022 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7412947
19 April 2021 Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7164902
28 January 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7132262
28 April 2020 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6939505
16 May 2019 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6675261
25 February 2019 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6625143
7 May 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6403187
6 June 2017 Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6153123
7 March 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6090265
28 April 2016 COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5838066

Deficiency record · 15

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2026 Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Each floating waterlight must be approved in accordance with § 161.010. Vessel has an unapproved waterlight attached to ring buoy. Vessel is restricted to daylight operations only.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 14 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2026 Resolved
Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Vessel has installed an unapproved fuel filter. Replace fuel filter with an approved type.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 14 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2026 Resolved
A vessel not required to have a power driven fire pump must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words ‘‘FIRE BUCKET’’ must be stenciled in a contrasting color on each bucket. Vessel is missing one out of the 3 required fire buckets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2026
Resolved 14 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 23 April 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2024
Resolved 3 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 April 2023 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessels name. Name stickers have come off the ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2023
Resolved 19 April 2023
Resolution: Ring buoy has been properly marked.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 6 April 2023 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions are not mounted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2023
Resolved 19 April 2023
Resolution: Emergency instructions are onboard and mounted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 30 March 2023 Resolved
A vessel exposed to salt water more than three months in a 12 month period must undergo a drydock and internal structural inspection at least once every two years. Vessel is overdue for credit drydock/ISE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2023
Resolution: Completed credit drydock/ISE.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 5 May 2022 Resolved
The master of the vessel shall keep a correct written count of all passengers that embark and disembark from the vessel. Prior to departing, the passenger count must be communicated verbally or in writing and available ashore at the vessel's normal berthing location or with a representative. No passenger count method established.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 16 May 2022
Resolution: Passenger count method has been established via logbook and calling the marina office.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 May 2022 Resolved
Provision must be made for closing all ducts and openings for a space protected by a fixed gas fire extinguishing system. Vessel does not have a way to close ventilation ducts for engine space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2022
Resolved 16 May 2022
Resolution: Obtained ventilation stuffing to use in case of fire.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 May 2022 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from fire, explosion, machinery failure, and personnel injury. Oil supply and return fittings on the turbo charger are leaking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 16 May 2022
Resolution: Got underway and verified no leaks, turbo charger has been repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 April 2021 Resolved
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Fuel filter assembly is not completely metallic and does not have a flame impingement bowl.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 30 April 2021
Resolution: Vessel obtained a new metallic bottom to the strainer.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 April 2021 Resolved
Each small battery installation must be protected from falling objects. The battery cover on one battery is cracked through.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 26 April 2021
Resolution: Replaced with a new battery cover.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 19 April 2021 Resolved
Except on a vessel limited to daytime operations, each magnetic compass must be illuminated. Compass wire is pulled out and cannot illuminate.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 30 April 2021
Resolution: Vessel wired connection from the compass to the new switchboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2021 Resolved
Each lifejacket must be marked in clearly legible block capital letters with the vessel's name. The markings on the lifejackets are faded and difficult to read.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 26 April 2021
Resolution: Vessel clearly marked the lifejackets with the vessel's name.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 April 2021 Resolved
Each lifejacket must be marked with Type I retroreflective material approved in 46 CDR 164.018. The arrangement must be applied as specified in IMO resolution A.658(16). The retroreflective material is worn.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2021
Resolved 26 April 2021
Resolution: Each lifejacket was marked with retroreflective material.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.