MAURY USCG vessel records Sign in
← All vessels

DELAFORT

DELAFORT is a 1990 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 1990, most recently in May 2026, along with 84 deficiencies and 1 casualty investigation in 2009.

Records from 1990 to 2026. Most recent: inspection, 11 May 2026.

Built
1990
Last inspected
11 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC5129
346683
Flag
UNITED STATES
367036210
Maury page id
psix-346683

Inspections, by type

…with no type recorded3
Years with a record 34 calendar years (1990–2026)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)55.0 ft × 16.5 ft × 6.5 ft
Registered tonnagegross 39 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderALUMINUM BOATS INC · JEAN LAFITTE, LA, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portWILMINGTON, DE
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Simplified, Gross Ton
31 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC5129MMSI 367036210 · active · compulsorily equipped · granted 25 January 2025, expires 23 April 2035
WAL2840MMSI not assigned · expired · compulsorily equipped · granted 13 February 1995, cancelled 9 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

11 May 2026 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8313379
9 May 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8131894
2 April 2025 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8104326
26 February 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8085096
14 May 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7911928
23 May 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7695049
21 November 2022 Hull Examination · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7598099
2 May 2022 Administrative Inspection · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7442294
7 February 2022 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7389975
29 June 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7238629
22 April 2021 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7181404
29 May 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6969092
31 March 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6937378
19 April 2019 Internal Structural Exam · DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6665897
9 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6505955
20 April 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6395780
5 April 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6385261
25 April 2017 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6132198
9 May 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5872203
21 March 2016 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 5837654
9 June 2014 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4883709
21 May 2012 DAPI Audit · Internal Structural Exam · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4311852
1 December 2011 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4219108
17 December 2009 Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3651407
13 April 2009 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3452188
5 August 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3289452
27 March 2007 Hull Examination · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2895775
13 July 2006 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2711196
18 July 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2430627
19 April 2005 Internal Structural Exam · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2338157
19 July 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2133779
11 August 2003 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1873010
23 June 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1821475
3 April 2003 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1767408
29 April 2002 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1609730
30 October 2001 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1076683
24 July 2001 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1069555
13 April 2001 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1435169
17 July 2000 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1051449
26 April 2000 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 817160
12 April 2000 Hull Examination · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 816427
4 April 2000 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 816615
21 July 1999 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1102658
22 April 1999 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1130106
5 March 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1125497
23 April 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1123794
12 March 1998 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1108594
12 May 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1104145
23 May 1996 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1085526
26 April 1996 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1081961
4 March 1996 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1377643
2 May 1995 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 833290
5 May 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 859073
22 April 1994 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1167437
24 February 1994 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 856026
19 April 1993 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 833186
24 February 1992 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 943067
3 May 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1235191
17 April 1991 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 999154
10 January 1991 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 913758
27 November 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1226450
13 April 1990 Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1212480
13 April 1990 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1223061

Deficiency record · 84

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 May 2026 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. MI observed a watertight bulkhead penetration in engine space forward of port engine into fuel tank space that was not watertight. Vessel is to make cable penetration watertight to the satisfaction of MI. 46 CFR 171.114 / 16 C 46 CFR 171.114 (old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2026
Resolved 28 May 2026
Resolution: Received proof of watertight cable penetration.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2025 Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter... All exposed materials must be resistant to oil or oil products, salt water and anticipated weather conditions encountered at sea. The life ring located at the stern was found to have dry-rotted grab lines and the life ring located at the port forward needed retro-reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 21 May 2025
Resolution: replaced with new; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 May 2025 Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent connectors. Spring or other temporary type clamps are not permitted. The batteries on-board had multiple temporary connectors (i.e. wing nuts). Replace with permanent kind. 46 CFR 183.05-20(c) "OLD T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 21 May 2025
Resolution: Wing nuts removed and replaced with permanent kind; sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 9 May 2025 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Multiple gaps were identified in the cable penetrations at the watertight bulkheads, specifically between the following areas: 1) the forward compartment and fuel tank compartment, and 2) the fuel tank compartment and engine space. Address the gaps to ensure watertight integrity.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 21 May 2025
Resolution: 3M 5200 marine grade sealant was installed around both sides of each cable penetration between the midships void and engine room and midships void and forward compartment to maintain watertight integrity; all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 February 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12-month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessels drydock is due on 28FEB2025. Carraige of passengers is not authorized until credited dry dock and ISE are complete
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2025
Resolution: Vessel completed dry dock and ISE.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 May 2024 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI's found plastic containers collecting lube oil from air box drains located under both MDE. Replace plastic containers collecting lube oil with fire safe material. 46 CFR 182.100
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 24 May 2024
Resolution: O/O provided photo evidence of repair (see Documents Section); all satisfactory.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 May 2024 Resolved
All electrical installations shall be to the satisfaction of the officer in charge, marine inspections. Found electrical wire powering bilge alarm in steering gear space secured to failing insulation. Properly secure electrical wire to bulkhead. 46 CFR 183.01-15(a) Old "T"
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 24 May 2024
Resolution: O/O provided photo evidence of repair (see Documents Section); all satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Found ring life buoy located starboard side of pilot house with faded vessel name. 46 CFR 185.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2024
Resolved 24 May 2024
Resolution: O/O provided photo evidence of repair (see Documents Section); all satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 23 May 2023 Resolved
Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry:(1) Three hand red flare distress signals approved in accordance with § 160.021 in subchapter Q of this chapter, or other standard specified by the Commandant; and(2) Three hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. All flares were expired. Replace with new flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2023
Resolved 23 May 2023
Resolution: Recieved verification and pictures showing new flares installed on the vessel
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2023 Resolved
A vessel must carry either a first-aid kit that must be easily visible and readily available to the crew. The first aid kit on board was expired. Replace with new first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2023
Resolved 23 May 2023
Resolution: Recieved information and verified placement of an unexpired first aid kit on board the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 May 2023 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from personnel injury. The manual fire pump actuator is adjacent to an uncovered, rotating belt. Cover belt with guard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 6 June 2023
Resolution: Recieved pictures verifying installation of protective guard around rotating machinery
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 May 2023 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Bridge portable flash light had dead batteries. Replace batteries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 26 May 2023
Resolution: Recieved verification that two new working batteries were installed onboard the vessel.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 23 May 2023 Resolved
Each hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains or other devices of substantial strength to prevent its loss. The hatch cover on the fuel tank space was not connected appropriately. Connect as appropriate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 26 May 2023
Resolution: Recieved verifying information that new captive device has been installed on the hatch cover
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 May 2022 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. Flame screens shall consist of a single screen of corrosion resistant wire of at least 30 X 30 mesh. Vessel's flame screen was torn. Replace with new 30 X 30 mesh screen. - 46 CFR 182.20-35(d) Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2022
Resolved 17 May 2022
Resolution: O/O submitted sufficient photos of newly installed flame screen.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 6 May 2022 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. The child and adult life jackets located in the life jacket containers on the vessel's top deck were not adequately separated from each other. Install a divider in the containers to separate the child size life jackets from the adult size, or stow these life jackets separately with appropriate markings. - 46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2022
Resolved 17 May 2022
Resolution: O/O submitted photos indicating child lifejacket stowage section labels.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 June 2021 Resolved
A power driven vessel underway shall exhibit ... a stern light. The stern light was inoperable. Replace/repair the stern light to fully operable condition. No night operations; fix NLT 14 days. CITE: 33 CFR §83.23
Action required: 705 - Other - as specified
Due 13 July 2021
Resolved 30 June 2021
Resolution: Vsl provided photo of light working.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 29 June 2021 Resolved
The master's FCC Operator's Permit was not on the vessel at the time of the inspection. Provide a copy of the Master's valid FCC Operator's Permit. (30 days) CITE: 47 CFR §80.13
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 July 2021
Resolved 12 July 2021
Resolution: Resolved via email of receipt for FCC Operator's Permit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 June 2021 Resolved
A copy of the vessel's enrollment in a recognized drug and alcohol consortium was not available at the time of the inspection. Provide a copy of the vessel's enrollment certification. CITE: 46 CFR §185.212
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2021
Resolved 30 June 2021
Resolution: Vsl provided copy of current DAPI Consortium enrollment.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 22 April 2021 Resolved
Several pitted areas were identified on the hull throughout bow to stern and on both starboard and port sides of vessel ranging from 20% to 40% depth. Provide repair proposal to address 03 areas of 40% wastage on starboard side, 04 areas of 40% wastage on port side and one 40% pit identified in the lazarette on port side of centerline prior to vessel receiving credit drydock. -46 CFR 176.802(a)(1)
Action required: 705 - Other - as specified
Due 22 April 2021
Resolved 3 June 2021
Resolution: Attended vessel to witness final weld testing of repairs, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 22 April 2021 Resolved
Cable penetrations through watertight bulkheads need to be made watertight. Watertight bulkheads #2, #3 and #4 had spray foam installed that is not substantially water tight. Provide acceptable material to protect against ingress of water with associated head pressure where penetrations are located in the spaces. - 46 CFR 176.802(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 May 2021
Resolved 12 May 2021
Resolution: O/O removed insulation which revealed that all cable penetrations were made with appropriate threaded fittings and is sufficiently watertight.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 June 2020 Resolved
Fire hose shall be fitted with a commercial garden hose nozzle of good grade bronze or equivalent material. Found nozzle inoperable; replace or repair. - 46 CFR 181.15-10 (e) (Old-T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 July 2020
Resolved 10 June 2020
Resolution: O/O replaced the nozzle.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 June 2020 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the Inland Navigation Rules. Found anchor light inoperable. Deficiency corrected on the spot. - 46 CFR 183.420 & 33 CFR 83.30
Action required: 10 - Deficiency Rectified
Due 3 June 2020
Resolved 3 June 2020
Resolution: O/O replaced the required light.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 April 2019 Resolved
Make bulkhead between void space and tank space watertight where speaker cable on starboard side penetrates
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2019
Resolution: Vessel POC sealed bulkhead penetrations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 April 2019 Resolved
Secure new speaker cable to existing wire run so it is supported every 24 inches
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2019
Resolution: Received picture of speaker cable secured to an existing run.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
Vsl is broadcasting: Invalid IMO # and NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V).
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 6 May 2022
Resolution: Vessel broadcasting proper name, vessel does not have an IMO number.
Operations/Management › Vessel Activity › Other
Issued 24 April 2018 Resolved
99101: Passenger count for voyages is not available ashore: make passenger count available to Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2018
Resolution: Will be retained by Fort Delaware State Park ticket office; added special note.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 24 April 2018 Resolved
09106: At each inspection for certification...toilets may be examined to determine that they are serviceable. Toilets not operable; provide CGMI w/ plan for rectification.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 2 May 2018
Resolution: Received picture of toilet installed.
Documentation › Markings/Placards › Garbage Placard
Issued 24 April 2018 Resolved
01310: Vessel does not have a placard detailing MARPOL discharge requirements: provide on vessel.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 25 April 2018
Resolution: Received pictures of 02 placards placed on vessel.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 24 April 2018 Resolved
04103: Vessel not equipped w/ two operable portable battery lights.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 26 April 2018
Resolution: Received picture of crew member holding new flashlights and batteries.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 24 April 2018 Resolved
18299: Vessel not equipped w/ following DAPI program info: company's policy statement, hotline numbers in a common space, knowledge of testing following a Serious Marine Incident, MIS report: provide to CGMI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2018
Resolved 25 April 2018
Resolution: Received email with required info from [name withheld] of DRBA.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 2 May 2017 Resolved
Demonstrate man overboard drills in the presence of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2017
Resolved 17 May 2017
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 2 May 2017 Resolved
Provide proof of enrollment in drug and alcohol program for all crew members.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2017
Resolved 5 May 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 2 May 2017 Resolved
Replace line on life ring and demonstrate operation of light attached to life ring. Prior to nightime operations.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 16 May 2017
Resolved 17 May 2017
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 2 May 2017 Resolved
Provide retro-reflective tape for 10 adult life jackets and 11 child life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2017
Resolved 17 May 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2017 Resolved
Make first aid kit meet 46CFR160.041 (ammonia inhalents)
Condition: Improper/Lack of Maintenance
Due 16 May 2017
Resolved 17 May 2017
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 May 2017 Resolved
Provide valid Radio Safety Telephony Certificate and Marine Radio Operators Permit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2017
Resolved 17 May 2017
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 9 May 2016 Resolved
Fireboy does not shut down main engines or ventilation. Fireboy shall be installed in accordance with manufacturer's specs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2016
Resolution: Corrected on the spot.
Lifesaving › Hand Flares › Not on Board
Issued 9 May 2016 Resolved
Provide 2 red hand flares or 2 orange smoke signals.
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 17 May 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 May 2016 Resolved
Provide First Aid Kit meeting 46CFR160.041.
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 17 May 2016
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 9 May 2016 Resolved
Lifejacket stowage shall be labled with accurate number of lifejackets.
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 17 May 2016
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 May 2016 Resolved
Emergency procedures shall reflect actual emergency operations.
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 17 May 2016
Documentation › Logs/Records › Logbook (official)
Issued 21 May 2012 Resolved
Vessel Does Not have logbook onboard. Provide proof of current training/bridge logbook. 46 CFR 185.420
Due 20 June 2012
Resolved 23 May 2012
Resolution: Recieved evidence that a new logbook was started and that proper entries were made.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 2012 Resolved
Replace eyewash in first aid kit. 46 CFR 184.710.
Due 20 June 2012
Resolved 23 May 2012
Resolution: Recieved proof that new eyewash was placed in first aid kit.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 August 2008 Resolved
Line on ring buoys are deteriorated.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 5 August 2008
Navigation › Piloting/Steering › US Coast Pilot
Issued 5 August 2008 Resolved
Light list is outdated.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 5 August 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 July 2006 Resolved
Engine override switch does not allow the engine to be started in the override position.
Action required: 705 - Other - as specified
Due 21 July 2006
Resolved 24 July 2006
Resolution: Vessel left msg and I followed up with a phone conversation. The solenoid underneath the bridge override control was inop and replaced. System is working properly.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 13 July 2006 Resolved
Crack was noted in the shaft packing support.
Action required: 705 - Other - as specified
Due 21 July 2006
Resolved 17 July 2006
Resolution: Vessel repaired crack, by grinding and welding.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 18 July 2005 Resolved
Wet fuel hose around fuel fill valve, owner instructed to tighten hose clamps and observe during next fueling.
Due 29 July 2005
Resolved 27 July 2005
Resolution: Operator tightened the clamps and wiped away signs of fuel. Vessel has fuel twice and there are no further signs of fuel on the hose.
Navigation
Issued 23 June 2003 Resolved
Repair compass light and provide for inspection.
Due 23 July 2003
Resolved 11 August 2003
Operations/Management › Pollution › Removal Methods/Procedures
Issued 23 June 2003 Resolved
Remove diesel fuel from fuel tank compartment bilge and address fuel oil piping leakage.
Due 23 July 2003
Resolved 11 August 2003
Operations/Management
Issued 23 June 2003 Resolved
Provide update Senior deckhand letter addressing all senior deck hands and demonstrate senior dechand proficiency.
Due 23 July 2003
Resolved 11 August 2003
Operations/Management
Issued 23 June 2003 Resolved
Provide chemical testing agreement for 2003 operating season.
Due 23 July 2003
Resolved 11 August 2003
Operations/Management › Drug and Alcohol Testing
Issued 29 April 2002 Resolved
PROVIDE PROOF OF CURRENT DRUG TESTING ENROLEMENT.
Due 29 May 2002
Resolved 3 May 2002
Stability › Watertight Integrity
Issued 29 April 2002 Resolved
RENEW GASKET ON WATER TIGHT HATCH ON FORWARD DECK.
Due 29 May 2002
Resolved 3 May 2002
Fire Fighting
Issued 24 July 2001 Resolved
INSTALL A LIGHT TO INDICATE DISCHARGE ON THE ENGINE ROOM PRE-ENGINEERED FIRE FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 1 October 2001
Resolved 31 October 2001
Fire Fighting
Issued 24 July 2001 Resolved
INSTALL A LIGHT TO INDICATE DISCHARGE ON THE ENGINEROOMS PRE-ENGINEERED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 1 October 2001
Resolved 31 October 2001
Electrical
Issued 24 July 2001 Resolved
REHANG ELECTRICAL WIRES IN ENGINE ROOM ON STARBOARD SIDE.
Condition: Unknown
Due 24 August 2001
Resolved 13 November 2001
Navigation
Issued 24 July 2001 Resolved
PROVIDE U.S. COAST PILOT VOLUME III AND LIGHT LIST VOULUME II.
Condition: Unknown
Due 24 August 2001
Resolved 31 October 2001
Documentation
Issued 24 July 2001 Resolved
PROVIDE CURRENT PROOF OF DRUG CONSORTIUM FOR DECKHANDS.
Condition: Unknown
Due 24 August 2001
Resolved 31 October 2001
Lifesaving
Issued 24 July 2001 Resolved
STENCIL AFT LIFERING WITH VESSEL's NAME.
Condition: Unknown
Due 24 August 2001
Resolved 31 October 2001
Documentation
Issued 24 July 2001 Resolved
DESIGNATE IN WRITING 1 MATE AS A SENIOR DECKHAND.
Condition: Unknown
Due 24 August 2001
Resolved 31 October 2001
Fire Fighting
Issued 24 July 2001 Resolved
INSTALL A MECHANICAL SHUTDOWN FOR ENGINEROOM VENTILATION.
Condition: Unknown
Due 1 October 2001
Resolved 31 October 2001
Fire Fighting
Issued 26 April 2000 Resolved
RE-LOCATE ONE B-II FIRE EXTINGUISHER TO AN AREA LOCATED NEAR THE ENGINE ROOM HATCH.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Lifesaving
Issued 26 April 2000 Resolved
PROVIDE UPDATED FIRST AID SUPPLIES IN FIRST AID KIT.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Engineering
Issued 26 April 2000 Resolved
PROVIDE PROPER MOUNTING BRACKETS FOR BOTH MAIN ENGINE SALT WATER STRAINERS AND SECURELY MOUNT IN POSITION.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Construction/Loadline
Issued 12 April 2000 Resolved
PRIOR TO COMMENCING REPAIRS PROVIDE REPAIR PROPOSAL TO PHIMS OUTLINING BELZONIA REPAIRS, OR REMOVAL OF BELZONIA, OR USE OF OTHER MATERIALS APPLIEDTO HULL.
Condition: Unknown
Due 12 May 2000
Resolved 2 May 2000
Construction/Loadline
Issued 4 April 2000 Resolved
PRIOR TO CARRYING PASSENGERS COMPLETE SATISFACTORY DRYDOCK EXAM._x001C_
Condition: Unknown
Due 4 April 2000
Resolved 4 April 2000
Engineering
Issued 12 May 1997 Resolved
PROVE PROPER OPERATION OF RELIEF VALVE INCLUDING HAND RELIEF FOR TOILET AIRRECEIVER.
Condition: Unknown
Due 24 May 1997
Resolved 13 May 1997
Construction/Loadline
Issued 12 May 1997 Resolved
PROVE PROPER OPERATION OF BILGE SYSTEM FOR COLLISION COMPARTMENT; REPLACE CHECK VALVE.
Condition: Unknown
Due 24 May 1997
Resolved 13 May 1997
Engineering
Issued 12 May 1997 Resolved
INSTALL TWO BONDING STRAPS ON FUEL FILL.
Condition: Unknown
Due 24 May 1997
Resolved 13 May 1997
Lifesaving
Issued 26 April 1996 Resolved
PROPERLY REPAIR BOTH BUOYANT APPARATUS IAW MANUFACTURERS APPROVED REPAIR KIT.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Construction/Loadline
Issued 4 March 1996 Resolved
REPAIR RIGHT SIDE OF CHOCK ON BOW USED AS ANCHOR GUIDE WHICH IS MISSING.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Construction/Loadline
Issued 4 March 1996 Resolved
REPLACE MISSING PLUG (BALL) FOR #2 PORT SIDE COMPARTMENT VENT.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Construction/Loadline
Issued 4 March 1996 Resolved
REPAIR FRACTURE FOUND ON PORT SIDE CHINE IN #2 COMPARTMENT BETWEEN #1 AND #2 TRANSVERSE FRAMES.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Documentation
Issued 2 May 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 May 1995
Resolved 3 May 1995
Engineering
Issued 22 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE A TACHOMETER FOR THE PORT ENGINE THATIS EQUIVALENT TO THE ORIGINAL GAUGE.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Lifesaving
Issued 22 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS AND WITH A PROPER CREW ON BOARD, CONDUCT UNDERWAY EMERGENCY DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Documentation
Issued 22 April 1994 Resolved
PROVIDE A VALID FCC OPERATOR'S LICENSE FOR THE VESSEL MASTER.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Documentation
Issued 22 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE EVIDENCE OF COMPLIANCE WITH THE DRUG TESTING REQUIREMENTS IN 46 CFR 16, ESPECIALLY THE RANDOM TESTING REQUIREMENTS.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Documentation
Issued 17 April 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Documentation
Issued 17 April 1991 Resolved
PROVIDE AND POST A POLLUTION PLACARD ONBOARD NEAR MACHINERY SPACE.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Accommodation/Occupational Safety
Issued 17 April 1991 Resolved
INSTALL AND PROVIDE DEMONSTATION OF MSD.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Documentation
Issued 17 April 1991 Resolved
PROVIDE AND POST EMERGENCY CHECK OFF LIST ONBOARD VESSEL.
Condition: Unknown
Due 17 April 1991
Resolved 17 April 1991
Accommodation/Occupational Safety
Issued 13 April 1990 Resolved
PRIOR TO CARRYING PASSENGERS, INSTALL FIXED SEATING TO ALLOW 18 IN. WIDTH PER PASSENGER AS FOLLOWS: (1)AISLES NOT OVER 15 FT. LONG SHALL BE NOT LESSTHAN 24 IN. WIDE. (2)AISLES OVER 15 FT. LONG SHALL BE NOT LESS THAN 30 IN. WIDE. (3)DISTANCE BETWEEN SEAT FRONTS SHALL BE NOT LESS THAN 30 IN.
Condition: Unknown
Due 13 April 1990
Resolved 13 April 1990

Casualty record · 1

14 October 2009Routine · role: Involved in a Marine Casualty · activity 3614832
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record