Records from 2016 to 2025. Most recent: inspection, 2 September 2025.
Inspection history · 20
2 September 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8197677
3 June 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8109637
6 September 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7979747
1 June 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7905711
28 August 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7754010
20 June 2023
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7671703
15 May 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7676942
7 June 2022
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7431721
22 September 2021
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7318113
16 June 2021
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7227470
8 October 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7073840
6 August 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6705607
18 June 2019
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6705593
22 February 2019
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6630863
22 February 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6645128
8 February 2019
Damage Survey · Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6622706
19 July 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6455814
26 June 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6161490
13 June 2017
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6161458
7 July 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5879781
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 2 September 2025
Resolved
Except as allowed by paragraph (e) of this section, each vessel certificated to operate on a limited coastwise route in warm water must be provided with life floats of an aggregate capacity that will accommodate at least 50% of the total number of persons permitted on board. Vessels inflatable life rafts are not onboard. Vessel route restricted to Lakes, Bays and Sounds.46CFR180.205(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 October 2025
Resolution: Picture provided with IBA's properly installed on vessel.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 September 2025
Resolved
Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter firehose is required by § 181.320(b). Existing vessels as of July 22, 2016 have 180 days to comply with this requirement. Spanner wrench not present onboard. Replace spanner wrench. 46CFR181.310(d)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2025
Resolved 10 September 2025
Resolution: New spanner wrench purchased, photograph provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 September 2024
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Lanyard for floating waterlight on bridge ring life buoy is deteriorated.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 18 September 2024
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 6 September 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Light cover on accommodation light located on the vessels port quarter is broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 18 September 2024
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 September 2024
Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. The pump outlet must be fitted with a pressure gauge. Pressure gauge on fire pump is broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 18 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 September 2024
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Bilge suction strainer in galley bilge is damaged/deteriorating.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 18 September 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 September 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for... protection against fire. The generator backflow prevention line is affixed to halon piping creating an unsafe condition.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 18 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 September 2024
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Both MDEs and generator missing shutoff values at the engine end of the fuel line.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 18 September 2024
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 September 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Rudder post packing is leaking seawater into bilge.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2024
Resolved 18 September 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 August 2023
Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing system into the space. The fixed fire extinguishing system in the engine does not secure the generator. Service report from July 20th, 2023 shows the generator securing test was completed and functioned properly. Code 701c issued to allow for one week to make repairs to system.
Action required: 705 - Other - as specified
Due 4 September 2023
Resolved 5 September 2023
Resolution: Conducted an satisfactory operational test of system
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 7 June 2022
Resolved
A hatch exposed to the weather must be watertight. Forward hatch cover wasted beyond serviceable condition.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2022
Resolved 28 June 2022
Resolution: Vessel provided proof of newly replaced, watertight hatch cover.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 June 2022
Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a through-hull fitting below the deepest load water line. Visual indicator for compartment number 02 "Goodie Locker" not operating.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 28 June 2022
Resolution: Vessel provided proof of fully operable bilge alarm system; visual indicator for compartment 02 fully operational on the bridge.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 September 2021
Resolved
Annual Inspection. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date. Vessel is overdue for its annual inspection. Vessel is to complete an annual inspection prior to carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 September 2021
Resolution: Conducted annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 October 2020
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and injury.
MI found SSDG leaking fuel at F/O nozzle banjo fitting (low psi). Fitting shall be repaired to provide serviceable condition of no leaks.
46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 8 October 2020
Resolved 8 October 2020
Resolution: Ships force clean up F/O along SSDG and retorqued fitting. Operational test sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 October 2020
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and injury.
MI found SSDG and the compartment box to have excessive oil all over it. No major oil leaks were seen and it appears as small amounts of oil are blown out of the Generator vent cover and because he SSDG is in a box, crew member do not notice the build up. SF will clean and prove oil is removed from all surfaces.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 October 2020
Resolved 8 October 2020
Resolution: Enclosure was properly cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 October 2020
Resolved
Valves to remove water or impurities from diesel strainers must be provided with caps or plugs to prevent leakage. MI found valves missing plugs to both MDE strainers. Provide caps/plugs. 46CFR182.455 (b)(9)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2020
Resolved 21 October 2020
Resolution: Vessel has provided documentation of installed plugs in the down spout of the drain valve to stop any accidental discharge from the drain valve of the fuel strainer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 October 2020
Resolved
Each life jacket must be marked with Type 1 retroreflective material approved in 46CFR164.018. MI found all lifejacket's reflective material to worn and no longer serviceable. Either clean and prove reflection or provide new retroreflective material with approved type on 132 Adult and 14 child life jackets.
46CFR185.604 (2)(h)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2020
Resolved 21 October 2020
Resolution: Vessel provided documentation showing all 132 adult and 14 child life jackets onboard have been re-taped with retroreflective tape.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 August 2019
Resolved
FOR FIXED GAS FIRE EXTINGUISHING SYSTEMS: IF ANY OF THE EQUIPMENT OR RECORDS HAVE NOT BEEN PROPERLY MAINTAINED, A QUALIFIED SERVICING FACILITY MAY BE REQUIRED TO PERFORM THE REQUIRED INSPECTIONS. HEAT ACTUATED DETCTORS IN ENGINE ROOM SHOWED EVIDENCE OF HEAT DAMAGE FROM IMPROPER TESTING. REPLACE IN KIND.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2019
Resolution: HAD's replaced by Marine Fire Protection.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 August 2019
Resolved
ANY VESSEL OVER FIVE NET TONS ENGAGED IN COASTWISE TRADE MUST HAVE A CERTIFICATE OF DOCUMENTATION BEARING A VALID ENDORSEMENT APPROPRIATE FOR THE ACTIVITY IN WHICH ENGAGED.VESSELS COD IS EXPIRED. PROVE SUBMISSION OF DOCUMENTATION AND PAYMENT TO NVDC.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 August 2019
Resolution: Vessel produced proof of payment to NVDC for re-issue of COD.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 6 August 2019
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 August 2019
Resolution: Vessel purchased and installed new EPIRB.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 February 2019
Resolved
The vessel must have on board a properly installed operational Coast Guard Type-approved Automatic Identification System Class A device.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 March 2019
Resolved 1 April 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 February 2019
Resolved
Vessel lost propulsion in both main diesel engines. Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Veseel must prove proper operation of main diesel engines prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 22 February 2019
Resolved 27 February 2019
Resolution: Conducted sea trial with engine manufacturers representatives.
Documentation › Markings/Placards › Capacity Marking
Issued 13 June 2017
Resolved
Mark maximium passengers permitted on the upper deck as per 46 CFR185.602(g).
Due 13 June 2017
Resolved 13 June 2017
Resolution: Completed during the inspection