MAURY USCG vessel records
← All vessels

ALABAMA CRUZIN

ALABAMA CRUZIN is a 1990 passenger vessel (uninspected). The Coast Guard has recorded 4 inspections since 2016, most recently in August 2017, along with 8 deficiencies.

Records from 2016 to 2017. Most recent: inspection, 16 August 2017.

Built
1990
Last inspected
16 August 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 August 2017
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

347416
Flag
UNITED STATES
Maury page id
psix-347416

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 4

16 August 2017 Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6242371
20 September 2016 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6005067
8 September 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5995423
3 August 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5961286

Deficiency record · 8

Fire Fighting › Remote Fuel Shutoff › General
Issued 11 August 2016 Resolved
Fuel shutoff valves not labeled. Label shutoff valves.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 8 September 2016
Resolution: Fuel valves labeled.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 August 2016 Resolved
Waterlight not stowed securely. Provide appropriate bracket for waterlight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 8 September 2016
Resolution: Proper bracket provided and installed.
Lifesaving › Lifebuoys › Approval
Issued 11 August 2016 Resolved
Buoy does not have retro reflective tape. Apply retro tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 8 September 2016
Resolution: Retro tape applied to life ring.
Navigation › Piloting/Steering › Marine Charts
Issued 11 August 2016 Resolved
Outdated charts w/out publications for route on-board vessel. Provide updated charts and pubs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 8 September 2016
Resolution: Updated chart provided.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 11 August 2016 Resolved
Emergency instruction not posted. Post the E.I. at operating station.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 8 September 2016
Resolution: Emergency instructions posted.
Operations/Management › Drills/Instruction › Fire
Issued 11 August 2016 Resolved
Drills need brief summary. Document drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 8 September 2016
Resolution: Provided drill format and it has what is needed for loging purpose.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 August 2016 Resolved
No consortium letter, or EAP supervisory training onboard. Provide proof of consortium and training.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 8 September 2016
Resolution: Consortium letter provided, and training completed.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 11 August 2016 Resolved
EAP hotline not posted. Post EAP hotline.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 September 2016
Resolved 8 September 2016
Resolution: Displayed DAPI program and hot line.

Ownership record