Records from 2016 to 2026. Most recent: inspection, 26 February 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)39.2 ft × 13.0 ft × 6.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRESMONDO BOAT WORKS · PERDIDO BEACH, AL, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 30 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
26 February 2026
Annual Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8317488
31 March 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8102810
10 March 2025
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8091179
3 February 2025
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8072782
21 February 2024
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7868861
16 May 2023
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 7690057
14 February 2023
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7636662
5 January 2023
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7616882
14 December 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7609419
14 February 2022
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7394071
1 April 2021
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7173504
25 February 2021
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7145595
6 April 2020
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6945071
6 August 2019
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6775204
2 April 2019
Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6654820
21 March 2019
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6647270
5 February 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6622576
3 April 2018
DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6381813
7 March 2017
COI Inspection · Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6098423
16 February 2016
Annual Inspection · Internal Structural Exam · DAPI Audit · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5915870
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 11 March 2025
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. The EPIRB hydrostatic release was found expired. Replace EPIRB hydrostatic release.
Action required: 705 - Other - as specified
Resolved 13 March 2025
Resolution: New Hydrostatic release for the EPIRB installed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 March 2025
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry. Six hand red flare distress signals and Six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. Vessel only 11 of 12 required distress signals at the time of inspection. Provide 12 distress signals to the satisfaction of a USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 12 March 2025
Resolution: 12 total distress signals onboard
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 March 2025
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. The battery for the
waterlight was found operable, but expired. Replace
battery to the satisfaction of a USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 March 2025
Resolution: Operator installed brand new float light
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The RACOR fuel filters for the port and starboard main engines were found fowled with water accumulation. Repair or replace fuel filters to the satisfaction of a Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2025
Resolution: New RACOR fuel filters were installed and satisfactory operations test was conducted.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 March 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel did not have a valid first aid kit, multiple items found expired. Provide first aid kit to the satisfaction of a Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2025
Resolution: New first aid kit was provided for the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 March 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The three installed AGM OPTIMA batteries were found expired and did not start the main engines as designed. Replace batteries to the satisfaction of a Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2025
Resolution: New batteries were installed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 March 2025
Resolved
A marine employer whose vessel is involved in a casualty
or incident that is, or is likely to become, a serious
marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2025
Resolved 31 March 2025
Resolution: Corrected
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 11 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards. Multiple dead end cables and wires found within the engine room overhead, above the starboard main engine. Remove wires not in service or properly cap to the satisfaction of a Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 12 March 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 March 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Portable lights were found inoperable. Repair or replace to the satisfaction of a Marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 March 2025
Resolution: Two Portable lights were provided
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 February 2024
Resolved
Hatch on stern deck was enlarged to service steering gear. Make aft deck watertight.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2024
Resolution: Access made watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 February 2024
Resolved
Wiring under operating station was unsatisfactory.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2024
Resolved 9 April 2024
Resolution: Wiring Satisfactory.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 3 April 2018
Resolved
Provide Alcohol testing strips for vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2018
Resolved 15 April 2018
Resolution: Prvided for vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 April 2018
Resolved
First Aid Kit expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2018
Resolved 4 April 2018
Resolution: provide new kit.
Lifesaving › Hand Flares › Not on Board
Issued 3 April 2018
Resolved
Provide 2 red hand flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2018
Resolved 4 April 2018
Resolution: Povided
Lifesaving › Lifebuoys › Serviceable
Issued 3 April 2018
Resolved
Provide Life Ring Buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 April 2018
Resolved 4 April 2018
Resolution: Provided.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 3 April 2018
Resolved
Provide Floating Electric Waterlight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2018
Resolved 4 April 2018
Resolution: Provided.
Lifesaving › Lifefloat › Serviceable
Issued 3 April 2018
Resolved
Repair surface of Life Float, and stack with a spacer.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2018
Resolved 15 April 2018
Resolution: Received Pic of reapired surface.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 March 2017
Resolved
Side lights un-operational.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 March 2017
Resolved 8 March 2017
Resolution: Side lights were fixed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 23 June 2016
Resolved
Provdie a FCC Safety Radio Telephony certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 8 August 2016
Resolution: Recieved FCC cert via Text message.
Communications › Radio Communications › EPIRB
Issued 23 June 2016
Resolved
Provide a Hydrostatic Release for the Vessels ERPIB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 8 August 2016