CAMOGLI STAR is a 1987 freight ship. The Coast Guard has recorded 23 inspections since 1995, most recently in October 2007, along with 6 deficiencies and 1 operational control.

Records from 1995 to 2007. Most recent: inspection, 28 October 2007.

Built
1987
Last inspected
28 October 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8714683 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
347749
Flag
CYPRUS
—
Maury page id
psix-347749

Inspections, by type

…with no type recorded12
Years with a record 12 calendar years (1995–2007)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it6030 - Regulatory (Subpart C or D), Gross Ton
3602 - Regulatory (Subpart C or D), Net Ton
9575 - Dead Weight, Ton
13266 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

28 October 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3088395
26 October 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3087770
15 September 2006 Enhanced Seaway Inspection (Massena only) · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2776177
15 September 2006 Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2776182
10 April 2006 Deficiency Check · ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2619516
23 March 2006 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2608828
23 June 2005 PII Safety Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2400668
20 December 2004 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2262468
20 November 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1951293
18 June 2002 Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1632481
29 January 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1483865
31 July 2000 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 280470
14 December 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 435651
20 August 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 431841
19 November 1998 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 422311
7 November 1998 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 422301
19 May 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 415876
27 October 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 409335
9 April 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 402247
30 September 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 395793
15 May 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 391265
27 March 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 389338
22 September 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 382981

Deficiency record · 6

Navigation › Piloting/Steering › Notices to Navigation
Issued 23 March 2006 Resolved
NAVTEX inop.
Due 28 March 2006
Resolved 10 April 2006
Resolution: NAVTEX has been replaced and is operational.
Navigation › Collision/Grounding Avoidance › Radar
Issued 20 December 2004 Resolved
01 Radar is inoperative. Have Radar Technician repair and present report to Coast Guard prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2004
Resolution: Deficiency has been corrected and cleared via tech report recieved at MSU Baton Rouge.
Pollution Prevention/Response › Prevention Equipment
Issued 4 February 2002 Resolved
Found wastage in Starboard bunker station fixed containment. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2002
Resolved 18 June 2002
Resolution: VERIFIED CORRECT DURING PSC RE EXAM. DEFICIENCY CLEARED.
Construction/Loadline › Structures
Issued 4 February 2002 Resolved
Found first tread on starboard ladder from main deck to foc'sle wasted. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2002
Resolved 18 June 2002
Resolution: DEFICIENCY WAS VERIFIED REPAIRED DURING PSC RX/DF. DEFICIENCY CLEARED.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 4 February 2002 Resolved
Found 53 kilo CO2 capacity forr oversized paint locker. Prove to the satisfaction of Class that CO2 capacity is sufficient for the volume of the paint locker located in the foc'sle. LEGACY COMPONENT DESC: Quantity of CO2
Action required: 705 - Other - as specified
Due 1 March 2002
Resolved 18 June 2002
Resolution: VERIFIED CORRECT DURING PSC RX/DF. VESSEL HAS LETTER FROM CLASS SOCIETY ATTESTING TO SATISFACTORY CAPACITY. DEFICIENCY CLEARED.
Documentation
Issued 27 March 1996 Resolved
MASTER DOES NOT POSSESS A HAZARDOUS MATERIALS HANDLING TRAINING CERTIFICATEAS REQUIRED BY 49 CFR 176.13(b).
Condition: Unknown
Due 15 May 1996
Resolved 15 May 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.