Records from 2001 to 2006. Most recent: inspection, 20 March 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
20 March 2006
Type not recorded
No type recorded · Marine Safety Center (MSC) · Activity 2605635
17 March 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2604481
23 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571572
4 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303724
22 February 2005
Annual Inspection · MTSA/ISPS Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2297103
10 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290208
16 December 2004
Internal Structural Exam · Hull Examination · Cargo Tank Internal
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2265647
10 November 2004
Drydock Extension
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2248216
1 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232677
20 July 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2139519
7 June 2004
MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066458
29 December 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971734
26 November 2003
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1954921
5 December 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1714733
18 March 2002
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1494530
15 November 2001
Initial Certification · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1450706
13 November 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772630
Fire Fighting › Grease Extraction Hood › General
Issued 22 February 2005
Resolved
Clean stove vent and ensure screen is in place.
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 22 February 2005
Resolution: Completed
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 22 February 2005
Resolved
Incorporate SOPEP changes into actual plan.
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 22 February 2005
Resolution: Changes inserted into plan.
Stability › Watertight Integrity › General
Issued 22 February 2005
Resolved
fix/adjust watertight door alarms leading into engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2005
Resolution: alarms working properly.
Fire Fighting › Firemans Outfit › Lantern (Electric Safety Lamp)
Issued 22 February 2005
Resolved
ensure firemans outfits are properly equiped in accordance with SOLAS regulation 17.
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 22 February 2005
Resolution: Appropriate flashlight, spare batteries and tending line supplied.
Lifesaving › Launching Appliances
Issued 26 November 2003
Resolved
Condition: Design Flaw
Due 11 December 2003
Resolved 17 December 2003
Lifesaving › Embarkation Appliances/Stations
Issued 26 November 2003
Resolved
embarkation procedures need to be clarified, and a proper location established and marked. LEGACY COMPONENT DESC: Accessability
Condition: Design Flaw
Due 11 December 2003
Resolved 17 December 2003
Lifesaving › Launching Appliances
Issued 5 December 2002
Resolved
PROVIDE RESCUE PLATFORM. LEGACY COMPONENT DESC: RESCUE PLATFORM
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2003
Resolved 6 December 2002
Navigation › Collision/Grounding Avoidance
Issued 5 December 2002
Resolved
REPAIR STBD RADAR. LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2003
Resolved 6 December 2002
Lifesaving › Hand Flares
Issued 5 December 2002
Resolved
LABEL DISTRESS FLARE BOX. LEGACY COMPONENT DESC: Marking
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2003
Resolved 6 December 2002
Documentation › Manuals/Policy Documentation
Issued 5 December 2002
Resolved
INSTALL FUEL AND LIQUID MUD TRANSFER PROCEDURES. LEGACY COMPONENT DESC: Transfer Procedures
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 January 2003
Resolved 6 December 2002
Lifesaving › Line-Throwing Appliances
Issued 5 December 2002
Resolved
PROPERLY CLEAN LINE THROWING GUN.
Due 5 January 2003
Resolved 6 December 2002
Communications › Radio Communications
Issued 5 December 2002
Resolved
PROVIDE PROPER REGISTRATION FOR EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2003
Resolved 6 December 2002
Stability › Weathertight Integrity
Issued 5 December 2002
Resolved
PROPERLY INSTALL PORT SIDE BRIDGE WINDOW. LEGACY COMPONENT DESC: BRIDGE WINDOW
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2003
Resolved 6 December 2002
Operations/Management › Pollution
Issued 5 December 2002
Resolved
PROVIDE WASTE MANAGEMENT PLAN. LEGACY COMPONENT DESC: Control of Garbage
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2003
Resolved 6 December 2002
Pollution Prevention/Response › Prevention Equipment
Issued 5 December 2002
Resolved
REPAIR AND TEST OILY WATER SEPARATOR. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2003
Resolved 6 December 2002