MAURY USCG vessel records
← All vessels

MAGNOLIA BLOSSOM

MAGNOLIA BLOSSOM is a 1990 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in May 2026, along with 33 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 5 May 2026.

Built
1990
Last inspected
5 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WBJ7814
348018
Flag
UNITED STATES
Maury page id
psix-348018

Documentation record

Registered dimensions (L × B × D)60.0 ft × 17.0 ft × 4.7 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMID-CITY STEEL FABRICATIN · LA CROSSE, WI, UNITED STATES · built 1990
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portST. LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

14 inspections, each with its date, unit and type; 33 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

5 May 2026 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8340481
4 August 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8200066
23 May 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7917245
25 May 2023 In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7694597
2 August 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7523026
5 May 2021 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7189966
5 April 2021 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7168821
9 February 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7138104
23 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7014224
23 July 2019 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6759795
30 July 2018 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6495363
6 July 2017 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6177901
6 May 2016 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5846822
31 March 2016 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5844630

Deficiency record · 33

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 August 2025 Resolved
A vessel on an LBS and rivers route must carry three hand red flare distress signals and three hand orange smoke distress signals approved in accordance with §160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. All flares were found expired; replace with new.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2025
Resolved 5 August 2025
Resolution: New distress signals purchased, and placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 August 2025 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or standard specified by the Commandant... Main deck forward life ring was found without retroflective tape. Apply tape with proper Type II tape equidistant in 04 spaces around ring.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2025
Resolution: Retro reflective tape applied to FWD life ring.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 August 2025 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. MOB drills not properly logged.
Action required: 705 - Other - as specified
Due 31 October 2025
Resolved 3 November 2025
Resolution: Training Logged.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 August 2025 Resolved
The master shall conduct sufficient drills to make sure that each crew member is familiar with his or her duties in case of a fire. Fire Drills not logged.
Action required: 705 - Other - as specified
Due 31 October 2025
Resolved 3 November 2025
Resolution: Training logged.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 May 2024 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Bolt hole was discovered in #4 void port side. Properly seal hole to make space watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 17 July 2024
Resolution: Hole properly sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 23 May 2024 Resolved
Each lighting fixture globe, lens or diffuser must have a guard or be made of high strength material... Globe was found missing from fixture in void #4. Replace with new.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 17 July 2024
Resolution: Globe re-installed on overhead light.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 May 2023 Resolved
Deck rails must be designed and constructed to withstand a pint load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direct. STBD FWD hand rail, and STBD AFT hand rail need to properly secured or renewed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 12 July 2023
Resolution: Hand rail, and upper deck railing replaced with new.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 May 2023 Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards in sofar as it is reasonable and practicable. Remove flammable liquids from engine room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2022 Resolved
A vessel of at least 26 feet (7.9 meters) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment, except that the space forward of the collision bulkhead need not be fitted with a bilge suction line when the arrangement is such that ordinary leaked may be removed through the use of a hand portable pump. Bilge was not able to draw suction due to a cracked manifold valve for water room. Replace, and re-test operation of bilge pump. 46 CFR 182.210(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2022
Resolution: Valve replaced with new. Op test Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2022 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Sewage room bilge suction strainer was discovered wasted. Replace with new. 46 CFR 182.510 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 3 August 2022
Resolution: Strainer replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2022 Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte. Port battery not installed in tray. Replace with correct battery, and install tray. 46 CFR 183.350(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 3 August 2022
Resolution: Correct battery, and tray installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. E/R electric bilge wire found now connected. Remove dead end wires. Electrical box on FWD bulkhead of water room was found with missing cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 12 September 2022
Resolution: Wires were properly capped.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 August 2022 Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018. 02 Life rings found with no retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 3 August 2022
Resolution: Retro tape attached to life rings.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 2 August 2022 Resolved
Employers must maintain records of chemical tests as provided by 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Records could not be provided by Vessel Captain.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 12 September 2022
Resolution: Witness DAPI roster.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 23 July 2020 Resolved
audio/visual indicators for high bilge alarms inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2020
Resolved 25 August 2020
Resolution: alarms operational
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 July 2020 Resolved
no record of fire/abandonship drills being conducted this season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2020
Resolved 14 September 2020
Resolution: owner sent photo of drill logs
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 July 2020 Resolved
starboard side lifejacket stowage door found stuck in place, unable to be opened without breaking the door. Also found stowage without proper marking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2020
Resolved 14 September 2020
Resolution: owner sent photo of newly installed door and labeling
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2018 Resolved
GFCI outlets are needed in two outlets in the galley area.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2018
Resolution: GFCI breaker installed.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 30 July 2018 Resolved
No record of fire fighting drills or MOB drills have been logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018 Resolved
Passenger count maximum is not marked on the upper deck as required by the stability letter.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018 Resolved
Replace zip ties as cable supports in the E/R with metal supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2018
Lifesaving › Hand Flares › Quantity
Issued 6 July 2017 Resolved
04 red flares were onboard; add 02 additional or add 03 orange.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 8 August 2017
Resolution: red flares purchased.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 July 2017 Resolved
Replace retroreflective tape on both liferings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 8 August 2017
Resolution: retro tape replaced.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 July 2017 Resolved
Provide proof of enrollment in a drug consortium.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 8 August 2017
Resolution: proof of enrollment provided.
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2016 Resolved
Upper deck life buoy was found with multiple deep holes through the foam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Life buoy replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2016 Resolved
Upper deck life buoy battery is expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Battery has been replaced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 May 2016 Resolved
Original COD needs to be onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Original COD is onboard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 May 2016 Resolved
Stern light inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Stern light and associated wiring was replaced and now operational.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 6 May 2016 Resolved
Bow ramp wires, also used as a rescue platform, were found twisted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 10 June 2016
Resolution: Verified bow ramp wires are rigged properly.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 6 May 2016 Resolved
Need proof that vessel is enrolled in a current drug consortium
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Owner provided proof of enrollment.
Engineering › Generator (propulsion-electric) › Winding
Issued 6 May 2016 Resolved
The screen on the generator winding end is dented and oil soaked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Screen has been replaced.
Engineering › Bilge Water Management System › Manifold
Issued 6 May 2016 Resolved
Bilge manifold labeling is missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Label has been replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2016 Resolved
Dead end wiring found in the E/R
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 6 May 2016
Resolution: Wiring has been removed.