Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Heartland District (CGD-H) · Other hulls named MAGNOLIA BLOSSOM
MAGNOLIA BLOSSOM is a 1990 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1990, most recently in May 2026, along with 80 deficiencies and 1 operational control.
Records from 1990 to 2026. Most recent: inspection, 5 May 2026.
- Built
- 1990
- Last inspected
- 5 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 80 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
963171
WBJ7814
348018
Flag
UNITED STATES
—
Maury page id
psix-348018
Inspections, by type
The 46 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 17.0 ft × 4.7 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMID-CITY STEEL FABRICATIN · LA CROSSE, WI, UNITED STATES · built 1990
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portST. LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
25 - Simplified, Net Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WBJ7814MMSI not assigned · expired · compulsorily equipped · granted 5 August 1997, cancelled 6 October 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 46
5 May 2026
COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8340481
4 August 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8200066
23 May 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7917245
25 May 2023
In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7694597
2 August 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7523026
5 May 2021
COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7189966
5 April 2021
COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7168821
9 February 2021
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7138104
23 July 2020
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7014224
23 July 2019
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6759795
30 July 2018
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6495363
6 July 2017
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6177901
6 May 2016
COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5846822
31 March 2016
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5844630
10 August 2015
Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5211782
25 August 2014
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4965162
28 July 2011
Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4097098
10 January 2011
Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3924257
7 July 2009
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3498532
15 July 2008
Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3268947
19 May 2008
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3191504
23 July 2007
Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3097521
20 July 2007
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3000701
26 May 2006
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2656695
6 October 2005
Examination of Repairs
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2508897
12 August 2005
Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2465903
16 August 2004
Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2167748
29 April 2003
Re-Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1783704
3 September 2002
Re-Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1672867
3 July 2001
COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1441877
26 June 2000
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1051862
18 May 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1365804
7 June 1999
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1455719
2 June 1998
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473467
31 July 1997
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1118192
26 June 1997
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1418205
30 July 1996
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1467935
24 April 1996
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1404178
14 June 1995
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1360144
22 August 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1380042
29 September 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1159960
19 July 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1153340
27 September 1992
Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 61908
1 July 1992
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1260626
16 June 1992
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1252857
17 May 1990
Initial Construction-Excluding Oversight · Plan Review "T" Boat · Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1241546
Deficiency record · 80
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 August 2025
Resolved
A vessel on an LBS and rivers route must carry three hand red flare distress signals and three hand orange smoke distress signals approved in accordance with §160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. All flares were found expired; replace with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 August 2025
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or standard specified by the Commandant... Main deck forward life ring was found without retroflective tape. Apply tape with proper Type II tape equidistant in 04 spaces around ring.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 August 2025
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. MOB drills not properly logged.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 August 2025
Resolved
The master shall conduct sufficient drills to make sure that each crew member is familiar with his or her duties in case of a fire. Fire Drills not logged.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 May 2024
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Bolt hole was discovered in #4 void port side. Properly seal hole to make space watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 23 May 2024
Resolved
Each lighting fixture globe, lens or diffuser must have a guard or be made of high strength material... Globe was found missing from fixture in void #4. Replace with new.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 May 2023
Resolved
Deck rails must be designed and constructed to withstand a pint load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direct. STBD FWD hand rail, and STBD AFT hand rail need to properly secured or renewed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 May 2023
Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards in sofar as it is reasonable and practicable. Remove flammable liquids from engine room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2022
Resolved
A vessel of at least 26 feet (7.9 meters) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment, except that the space forward of the collision bulkhead need not be fitted with a bilge suction line when the arrangement is such that ordinary leaked may be removed through the use of a hand portable pump. Bilge was not able to draw suction due to a cracked manifold valve for water room. Replace, and re-test operation of bilge pump. 46 CFR 182.210(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2022
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Sewage room bilge suction strainer was discovered wasted. Replace with new. 46 CFR 182.510 (b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2022
Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte. Port battery not installed in tray. Replace with correct battery, and install tray. 46 CFR 183.350(f)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. E/R electric bilge wire found now connected. Remove dead end wires. Electrical box on FWD bulkhead of water room was found with missing cover.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 August 2022
Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018. 02 Life rings found with no retro reflective tape.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 2 August 2022
Resolved
Employers must maintain records of chemical tests as provided by 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Records could not be provided by Vessel Captain.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 23 July 2020
Resolved
audio/visual indicators for high bilge alarms inoperable.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 July 2020
Resolved
no record of fire/abandonship drills being conducted this season.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 July 2020
Resolved
starboard side lifejacket stowage door found stuck in place, unable to be opened without breaking the door. Also found stowage without proper marking.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2018
Resolved
GFCI outlets are needed in two outlets in the galley area.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 30 July 2018
Resolved
No record of fire fighting drills or MOB drills have been logged.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018
Resolved
Passenger count maximum is not marked on the upper deck as required by the stability letter.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018
Resolved
Replace zip ties as cable supports in the E/R with metal supports.
Lifesaving › Hand Flares › Quantity
Issued 6 July 2017
Resolved
04 red flares were onboard; add 02 additional or add 03 orange.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 July 2017
Resolved
Replace retroreflective tape on both liferings.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 July 2017
Resolved
Provide proof of enrollment in a drug consortium.
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2016
Resolved
Upper deck life buoy was found with multiple deep holes through the foam.
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2016
Resolved
Upper deck life buoy battery is expired.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 May 2016
Resolved
Original COD needs to be onboard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 May 2016
Resolved
Stern light inoperable.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 6 May 2016
Resolved
Bow ramp wires, also used as a rescue platform, were found twisted.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 6 May 2016
Resolved
Need proof that vessel is enrolled in a current drug consortium
Engineering › Generator (propulsion-electric) › Winding
Issued 6 May 2016
Resolved
The screen on the generator winding end is dented and oil soaked.
Engineering › Bilge Water Management System › Manifold
Issued 6 May 2016
Resolved
Bilge manifold labeling is missing
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2016
Resolved
Dead end wiring found in the E/R
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 August 2014
Resolved
Remove excess oil from engineroom bilge.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 August 2014
Resolved
Remove dead end wires from engine room bulkhead between stbd main engine and generator.
Communications › Radio Communications › VHF Radiotelephone
Issued 26 August 2014
Resolved
Provide on board emergency broadcast placard.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 26 August 2014
Resolved
Make operational port lifejacket storage locker door.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 August 2014
Resolved
Correct arch of visibility of anchor light.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 July 2009
Resolved
Current COD is expired; obtain valid COD IAW 46 CFR 67.6
Lifesaving › Lifebuoys › Not on Board
Issued 7 July 2009
Resolved
Ring buoy missing type II Retro Tape, place type II Retro reflective Tape on each ring buoy IAW 46 CFR 185.604
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 July 2009
Resolved
Correctly mark # of Adult and Child Life Jackets IAW 46 CFR 180.78 on outside storage locations.
Documentation › Markings/Placards › Lifejacket Placard
Issued 7 July 2009
Resolved
Place Life Jacket Donning Placards inside bulkhead IAW 46 CFR 185.56
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 7 July 2009
Resolved
Show proof of arrangements are made for Post Casualty Testing IAW 46 CFR 16.24
Electrical › Lighting (service) › Lighting Fixture
Issued 7 July 2009
Resolved
Replace missing globe on center light located in Engine Room IAW 46 CFR 183.40
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 24 July 2008
Resolved
Two crewmembers were not enrolled in a chemical testing program.
Electrical › Electrical Distribution System (service) › Cable
Issued 19 May 2008
Resolved
Port main engine starter battery positive cable insulation is cracked. Replace or repair cable 46 CFR 183.01-15
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 May 2008
Resolved
Replace missing fasteners on 2nd deck railing, 2 missing. 46 CFR 177.35-1
Deck/Cargo › Cargo Refrigeration › General
Issued 19 May 2008
Resolved
Secure pop machine compressor in #5 compartment and air conditioner pump in #2 compartment 46 CFR182.10-5
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 19 May 2008
Resolved
Provide evidence of compliance with 46 CFR 16 to include a) MIS Report b) Past test results c) supervisor 1 hour training and d) testing rate.
Engineering › Bilge Water Management System › Manifold
Issued 20 July 2007
Resolved
Relabel bilge manifold in engine room.
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 July 2007
Resolved
Replace Generator battery box cover.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 July 2007
Resolved
Replace/ update first aid kit.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 July 2007
Resolved
Put / install light fixture covers on overhead lights in galley.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 July 2007
Resolved
Install an electrical outlet cover on receptical in way of engine room hatch (Main deck)
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 July 2007
Resolved
Vessel limited to max passenger of 139, upper deck 64, main deck 75 per 46 CFR 176.13
Electrical › Electrical Distribution System (service) › Cable
Issued 20 July 2007
Resolved
Remove portable electrical cable for fwd bar area cooler or replace
Lifesaving › Hand Flares › Storage
Issued 20 July 2007
Resolved
Provide and mark watertight container for flares IAW 180.68 and 185.614
Communications › Radio Communications › VHF Radiotelephone
Issued 20 July 2007
Resolved
Provide Emergency broadcast placard VHF radio
Operations/Management › Passenger Operations › Safety Orientation
Issued 20 July 2007
Resolved
Install Passenger count box on dock
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 20 July 2007
Resolved
Prior to carrrying passengers for hire submit documentation indicating all employees involved with passengers are in an approved DOT drug testing program.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 26 May 2006
Resolved
Prove proper operation of vessel's high water level bilge alarms.
Construction/Loadline
Issued 3 July 2001
Resolved
REPAIR LEAKING COOLING WATER SUCTION LINE IN ENGINE ROOM.
Lifesaving
Issued 18 May 2000
Resolved
PROVIDE RETRO REFLECTIVE TAPE TO RING BUOYS.
Construction/Loadline
Issued 18 May 2000
Resolved
PROVIDE AND INSTALL LANYARD TO HATCH COVER TO FORE PEAK TANK ON MAIN DECK
Accommodation/Occupational Safety
Issued 18 May 2000
Resolved
REPLACE OUTDATED ITEMS IN FIRST AID KIT
Construction/Loadline
Issued 7 June 1999
Resolved
PROVIDE AND INSTALL HIGH LEVEL BILGE ALARMS (VISUAL & AUDIBLE) NEAR THE PILOT STATION FOR THE ENGINE COMPARTMENT & THE A/C PUMP COMPARTMENT.
Construction/Loadline
Issued 7 June 1999
Resolved
REPAIR OR REPLACE BOTH DOORS ON FORWARD PFD STOWAGE COMPARTMENTS.
Electrical
Issued 19 July 1993
Resolved
Provide cover for the generator battery box not later than the compliance date.
Lifesaving
Issued 19 July 1993
Resolved
Provide upperdeck stowage location for childrens life preservers not later than the compliance date.
Lifesaving
Issued 19 July 1993
Resolved
Provide one adult life preserver not later than the compliance date. The vessel is restricted to the carriage of 117 persons until the approved lifepreserver is place onboard.
Documentation
Issued 17 May 1990
Resolved
PROVIDE FCC LICENSE.
Electrical
Issued 17 May 1990
Resolved
PROVIDE RUBBER MAT IN FRONT OF THE GENERATOR MAIN PANEL.
Lifesaving
Issued 17 May 1990
Resolved
PROVIDE 13 ADULT AND 01 CHILD-SIZE PFDS. UNTIL THIS ITEM IS COMPLETED THE NUMBER OF PERSONS ON BOARD IS REDUCED TO 105 ADULT AND 11 CHILDREN.
Construction/Loadline
Issued 17 May 1990
Resolved
PROVIDE A LATCHING MECHANISM ON ALL HINGED HATCHES TO PREVENT THE HATCH FROM ACCIDENTALY CLOSING.
Engineering
Issued 17 May 1990
Resolved
DOUBLE CLAMP ALL COOLING WATER FLEX HOSES ON THE MAIN ENGINES AND GENERATOR
Engineering
Issued 17 May 1990
Resolved
PROVIDE GUARD ON BOTH MAIN ENGINES AND GENERATOR.
Lifesaving
Issued 17 May 1990
Resolved
PROVIDE PROPER STOWAGE FOR SECOND DECK PFDS.
Accommodation/Occupational Safety
Issued 17 May 1990
Resolved
PROVIDE A FLASHLIGHT FOR EMERGENCY LIGHTING.
Documentation
Issued 17 May 1990
Resolved
MOUNT CERTIFICATE OF DOCUMENTATION, STABILITY LETTER, AND COI.
Lifesaving
Issued 17 May 1990
Resolved
REPAIR/REPLACE WATERLIGHT.