MAURY USCG vessel records Sign in
← All vessels

MAGNOLIA BLOSSOM

MAGNOLIA BLOSSOM is a 1990 passenger vessel (inspected). The Coast Guard has recorded 46 inspections since 1990, most recently in May 2026, along with 80 deficiencies and 1 operational control.

Records from 1990 to 2026. Most recent: inspection, 5 May 2026.

Built
1990
Last inspected
5 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBJ7814
348018
Flag
UNITED STATES
—
Maury page id
psix-348018

Inspections, by type

…with no type recorded2
Years with a record 33 calendar years (1990–2026)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.0 ft × 17.0 ft × 4.7 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMID-CITY STEEL FABRICATIN · LA CROSSE, WI, UNITED STATES · built 1990
Hull materialSteel
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portST. LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 21 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Simplified, Gross Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBJ7814MMSI not assigned · expired · compulsorily equipped · granted 5 August 1997, cancelled 6 October 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 46

5 May 2026 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8340481
4 August 2025 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8200066
23 May 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7917245
25 May 2023 In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7694597
2 August 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7523026
5 May 2021 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7189966
5 April 2021 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7168821
9 February 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7138104
23 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7014224
23 July 2019 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6759795
30 July 2018 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6495363
6 July 2017 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6177901
6 May 2016 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5846822
31 March 2016 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5844630
10 August 2015 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5211782
25 August 2014 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4965162
28 July 2011 Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4097098
10 January 2011 Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3924257
7 July 2009 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3498532
15 July 2008 Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3268947
19 May 2008 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3191504
23 July 2007 Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3097521
20 July 2007 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3000701
26 May 2006 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2656695
6 October 2005 Examination of Repairs
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2508897
12 August 2005 Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2465903
16 August 2004 Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2167748
29 April 2003 Re-Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1783704
3 September 2002 Re-Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1672867
3 July 2001 COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1441877
26 June 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1051862
18 May 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1365804
7 June 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1455719
2 June 1998 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473467
31 July 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1118192
26 June 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1418205
30 July 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1467935
24 April 1996 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1404178
14 June 1995 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1360144
22 August 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1380042
29 September 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1159960
19 July 1993 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1153340
27 September 1992 Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 61908
1 July 1992 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1260626
16 June 1992 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1252857
17 May 1990 Initial Construction-Excluding Oversight · Plan Review "T" Boat · Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1241546

Deficiency record · 80

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 August 2025 Resolved
A vessel on an LBS and rivers route must carry three hand red flare distress signals and three hand orange smoke distress signals approved in accordance with §160.037 in subchapter Q of this chapter, or other standard specified by the Commandant. All flares were found expired; replace with new.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2025
Resolved 5 August 2025
Resolution: New distress signals purchased, and placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 August 2025 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or standard specified by the Commandant... Main deck forward life ring was found without retroflective tape. Apply tape with proper Type II tape equidistant in 04 spaces around ring.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 August 2025
Resolution: Retro reflective tape applied to FWD life ring.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 August 2025 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. MOB drills not properly logged.
Action required: 705 - Other - as specified
Due 31 October 2025
Resolved 3 November 2025
Resolution: Training Logged.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 August 2025 Resolved
The master shall conduct sufficient drills to make sure that each crew member is familiar with his or her duties in case of a fire. Fire Drills not logged.
Action required: 705 - Other - as specified
Due 31 October 2025
Resolved 3 November 2025
Resolution: Training logged.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 23 May 2024 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Bolt hole was discovered in #4 void port side. Properly seal hole to make space watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 17 July 2024
Resolution: Hole properly sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 23 May 2024 Resolved
Each lighting fixture globe, lens or diffuser must have a guard or be made of high strength material... Globe was found missing from fixture in void #4. Replace with new.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2024
Resolved 17 July 2024
Resolution: Globe re-installed on overhead light.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 May 2023 Resolved
Deck rails must be designed and constructed to withstand a pint load of 200 pounds applied at any point in any direction, and a uniform load of 50 pounds per foot applied to the top rail in any direct. STBD FWD hand rail, and STBD AFT hand rail need to properly secured or renewed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2023
Resolved 12 July 2023
Resolution: Hand rail, and upper deck railing replaced with new.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 May 2023 Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards in sofar as it is reasonable and practicable. Remove flammable liquids from engine room.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 May 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2022 Resolved
A vessel of at least 26 feet (7.9 meters) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment, except that the space forward of the collision bulkhead need not be fitted with a bilge suction line when the arrangement is such that ordinary leaked may be removed through the use of a hand portable pump. Bilge was not able to draw suction due to a cracked manifold valve for water room. Replace, and re-test operation of bilge pump. 46 CFR 182.210(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2022
Resolution: Valve replaced with new. Op test Sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2022 Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe. Sewage room bilge suction strainer was discovered wasted. Replace with new. 46 CFR 182.510 (b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 3 August 2022
Resolution: Strainer replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2022 Resolved
Batteries must be mounted in trays lined with, or constructed of, a material that is resistant to damage by the electrolyte. Port battery not installed in tray. Replace with correct battery, and install tray. 46 CFR 183.350(f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 3 August 2022
Resolution: Correct battery, and tray installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 August 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. E/R electric bilge wire found now connected. Remove dead end wires. Electrical box on FWD bulkhead of water room was found with missing cover.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 12 September 2022
Resolution: Wires were properly capped.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 August 2022 Resolved
Each ring life buoy must be marked with Type II retro-reflective material approved in accordance with 46 CFR 164.018. 02 Life rings found with no retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 3 August 2022
Resolution: Retro tape attached to life rings.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Health protection, medical care?)
Issued 2 August 2022 Resolved
Employers must maintain records of chemical tests as provided by 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Records could not be provided by Vessel Captain.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2022
Resolved 12 September 2022
Resolution: Witness DAPI roster.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 23 July 2020 Resolved
audio/visual indicators for high bilge alarms inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2020
Resolved 25 August 2020
Resolution: alarms operational
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 July 2020 Resolved
no record of fire/abandonship drills being conducted this season.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2020
Resolved 14 September 2020
Resolution: owner sent photo of drill logs
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 July 2020 Resolved
starboard side lifejacket stowage door found stuck in place, unable to be opened without breaking the door. Also found stowage without proper marking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2020
Resolved 14 September 2020
Resolution: owner sent photo of newly installed door and labeling
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 July 2018 Resolved
GFCI outlets are needed in two outlets in the galley area.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2018
Resolution: GFCI breaker installed.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 30 July 2018 Resolved
No record of fire fighting drills or MOB drills have been logged.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018 Resolved
Passenger count maximum is not marked on the upper deck as required by the stability letter.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 July 2018 Resolved
Replace zip ties as cable supports in the E/R with metal supports.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2018
Lifesaving › Hand Flares › Quantity
Issued 6 July 2017 Resolved
04 red flares were onboard; add 02 additional or add 03 orange.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 8 August 2017
Resolution: red flares purchased.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 July 2017 Resolved
Replace retroreflective tape on both liferings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 8 August 2017
Resolution: retro tape replaced.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 6 July 2017 Resolved
Provide proof of enrollment in a drug consortium.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2017
Resolved 8 August 2017
Resolution: proof of enrollment provided.
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2016 Resolved
Upper deck life buoy was found with multiple deep holes through the foam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Life buoy replaced.
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2016 Resolved
Upper deck life buoy battery is expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Battery has been replaced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 6 May 2016 Resolved
Original COD needs to be onboard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Original COD is onboard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 May 2016 Resolved
Stern light inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Stern light and associated wiring was replaced and now operational.
Lifesaving › Rescue Boat › Embarkation/Disembarkation Capabilities
Issued 6 May 2016 Resolved
Bow ramp wires, also used as a rescue platform, were found twisted.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 10 June 2016
Resolution: Verified bow ramp wires are rigged properly.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 6 May 2016 Resolved
Need proof that vessel is enrolled in a current drug consortium
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Owner provided proof of enrollment.
Engineering › Generator (propulsion-electric) › Winding
Issued 6 May 2016 Resolved
The screen on the generator winding end is dented and oil soaked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Screen has been replaced.
Engineering › Bilge Water Management System › Manifold
Issued 6 May 2016 Resolved
Bilge manifold labeling is missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 1 June 2016
Resolution: Label has been replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 May 2016 Resolved
Dead end wiring found in the E/R
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 6 May 2016
Resolution: Wiring has been removed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 26 August 2014 Resolved
Remove excess oil from engineroom bilge.
Due 29 August 2014
Resolved 8 September 2014
Resolution: Bilges Cleaned as required.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 August 2014 Resolved
Remove dead end wires from engine room bulkhead between stbd main engine and generator.
Due 26 September 2014
Resolved 8 September 2014
Resolution: Wires removed as required.
Communications › Radio Communications › VHF Radiotelephone
Issued 26 August 2014 Resolved
Provide on board emergency broadcast placard.
Due 26 September 2014
Resolved 8 September 2014
Resolution: Emergency broadcast placard on board.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 26 August 2014 Resolved
Make operational port lifejacket storage locker door.
Due 26 August 2014
Resolved 8 September 2014
Resolution: Door made operational.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 August 2014 Resolved
Correct arch of visibility of anchor light.
Due 26 September 2014
Resolved 8 September 2014
Resolution: Light corrected.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 July 2009 Resolved
Current COD is expired; obtain valid COD IAW 46 CFR 67.6
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 10 August 2009
Resolution: Valid COD obtained
Lifesaving › Lifebuoys › Not on Board
Issued 7 July 2009 Resolved
Ring buoy missing type II Retro Tape, place type II Retro reflective Tape on each ring buoy IAW 46 CFR 185.604
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 12 August 2009
Resolution: Type 2 retro tape now installed on both life rings.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 July 2009 Resolved
Correctly mark # of Adult and Child Life Jackets IAW 46 CFR 180.78 on outside storage locations.
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 10 August 2009
Resolution: Item completed.
Documentation › Markings/Placards › Lifejacket Placard
Issued 7 July 2009 Resolved
Place Life Jacket Donning Placards inside bulkhead IAW 46 CFR 185.56
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 10 August 2009
Resolution: O/O placed extra donning placards inside heads. Also requested O/O to place outside the heads as well.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 7 July 2009 Resolved
Show proof of arrangements are made for Post Casualty Testing IAW 46 CFR 16.24
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 10 August 2009
Resolution: O/O contacted APCA who provided documentation to conduct Post Casulty Testing
Electrical › Lighting (service) › Lighting Fixture
Issued 7 July 2009 Resolved
Replace missing globe on center light located in Engine Room IAW 46 CFR 183.40
Action required: 705 - Other - as specified
Due 7 August 2009
Resolved 12 August 2009
Resolution: Owner removed the light fixture and associated wiring.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 24 July 2008 Resolved
Two crewmembers were not enrolled in a chemical testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 July 2008
Resolved 4 August 2008
Resolution: Owner/operated enrolled the two crewmembers and provided evidence of that fact.
Electrical › Electrical Distribution System (service) › Cable
Issued 19 May 2008 Resolved
Port main engine starter battery positive cable insulation is cracked. Replace or repair cable 46 CFR 183.01-15
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 24 July 2008
Resolution: Cable replaced
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 May 2008 Resolved
Replace missing fasteners on 2nd deck railing, 2 missing. 46 CFR 177.35-1
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 24 July 2008
Resolution: Owner/operator refastened 2nd deck railing to deck.
Deck/Cargo › Cargo Refrigeration › General
Issued 19 May 2008 Resolved
Secure pop machine compressor in #5 compartment and air conditioner pump in #2 compartment 46 CFR182.10-5
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 24 July 2008
Resolution: Items secured to the deck
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 19 May 2008 Resolved
Provide evidence of compliance with 46 CFR 16 to include a) MIS Report b) Past test results c) supervisor 1 hour training and d) testing rate.
Action required: 705 - Other - as specified
Due 2 June 2008
Resolved 24 July 2008
Resolution: Owner/Operator provided evidence of drug consortium MIS Report, Past test results, and supervisor training.
Engineering › Bilge Water Management System › Manifold
Issued 20 July 2007 Resolved
Relabel bilge manifold in engine room.
Action required: 705 - Other - as specified
Due 20 August 2007
Resolved 23 July 2007
Resolution: corrected
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 July 2007 Resolved
Replace Generator battery box cover.
Action required: 705 - Other - as specified
Due 20 August 2007
Resolved 23 July 2007
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 July 2007 Resolved
Replace/ update first aid kit.
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 23 July 2007
Resolution: Replacec
Electrical › Lighting (service) › Lighting Fixture
Issued 20 July 2007 Resolved
Put / install light fixture covers on overhead lights in galley.
Action required: 705 - Other - as specified
Due 20 August 2007
Resolved 23 July 2007
Resolution: Installed
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 July 2007 Resolved
Install an electrical outlet cover on receptical in way of engine room hatch (Main deck)
Action required: 705 - Other - as specified
Due 20 August 2007
Resolved 23 July 2007
Resolution: Installed
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 July 2007 Resolved
Vessel limited to max passenger of 139, upper deck 64, main deck 75 per 46 CFR 176.13
Action required: 705 - Other - as specified
Resolved 9 January 2008
Resolution: Amended COI issued this date reflecting proper number of passengers, 139
Electrical › Electrical Distribution System (service) › Cable
Issued 20 July 2007 Resolved
Remove portable electrical cable for fwd bar area cooler or replace
Action required: 705 - Other - as specified
Due 20 August 2007
Resolved 23 July 2007
Resolution: Removed
Lifesaving › Hand Flares › Storage
Issued 20 July 2007 Resolved
Provide and mark watertight container for flares IAW 180.68 and 185.614
Action required: 705 - Other - as specified
Due 20 August 2007
Resolved 23 July 2007
Resolution: Provided
Communications › Radio Communications › VHF Radiotelephone
Issued 20 July 2007 Resolved
Provide Emergency broadcast placard VHF radio
Action required: 705 - Other - as specified
Due 20 August 2007
Resolved 23 July 2007
Resolution: Provided
Operations/Management › Passenger Operations › Safety Orientation
Issued 20 July 2007 Resolved
Install Passenger count box on dock
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2007
Resolution: Installed
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 20 July 2007 Resolved
Prior to carrrying passengers for hire submit documentation indicating all employees involved with passengers are in an approved DOT drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2007
Resolution: All employees in dot approved program
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 26 May 2006 Resolved
Prove proper operation of vessel's high water level bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2006
Resolved 31 May 2006
Resolution: Observed proper operation of both high water level bilge alarms.
Construction/Loadline
Issued 3 July 2001 Resolved
REPAIR LEAKING COOLING WATER SUCTION LINE IN ENGINE ROOM.
Condition: Unknown
Due 17 July 2001
Resolved 24 July 2001
Lifesaving
Issued 18 May 2000 Resolved
PROVIDE RETRO REFLECTIVE TAPE TO RING BUOYS.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Construction/Loadline
Issued 18 May 2000 Resolved
PROVIDE AND INSTALL LANYARD TO HATCH COVER TO FORE PEAK TANK ON MAIN DECK
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Accommodation/Occupational Safety
Issued 18 May 2000 Resolved
REPLACE OUTDATED ITEMS IN FIRST AID KIT
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Construction/Loadline
Issued 7 June 1999 Resolved
PROVIDE AND INSTALL HIGH LEVEL BILGE ALARMS (VISUAL & AUDIBLE) NEAR THE PILOT STATION FOR THE ENGINE COMPARTMENT & THE A/C PUMP COMPARTMENT.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Construction/Loadline
Issued 7 June 1999 Resolved
REPAIR OR REPLACE BOTH DOORS ON FORWARD PFD STOWAGE COMPARTMENTS.
Condition: Unknown
Due 7 June 1999
Resolved 7 June 1999
Electrical
Issued 19 July 1993 Resolved
Provide cover for the generator battery box not later than the compliance date.
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Lifesaving
Issued 19 July 1993 Resolved
Provide upperdeck stowage location for childrens life preservers not later than the compliance date.
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Lifesaving
Issued 19 July 1993 Resolved
Provide one adult life preserver not later than the compliance date. The vessel is restricted to the carriage of 117 persons until the approved lifepreserver is place onboard.
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Documentation
Issued 17 May 1990 Resolved
PROVIDE FCC LICENSE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Electrical
Issued 17 May 1990 Resolved
PROVIDE RUBBER MAT IN FRONT OF THE GENERATOR MAIN PANEL.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Lifesaving
Issued 17 May 1990 Resolved
PROVIDE 13 ADULT AND 01 CHILD-SIZE PFDS. UNTIL THIS ITEM IS COMPLETED THE NUMBER OF PERSONS ON BOARD IS REDUCED TO 105 ADULT AND 11 CHILDREN.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Construction/Loadline
Issued 17 May 1990 Resolved
PROVIDE A LATCHING MECHANISM ON ALL HINGED HATCHES TO PREVENT THE HATCH FROM ACCIDENTALY CLOSING.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 17 May 1990 Resolved
DOUBLE CLAMP ALL COOLING WATER FLEX HOSES ON THE MAIN ENGINES AND GENERATOR
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 17 May 1990 Resolved
PROVIDE GUARD ON BOTH MAIN ENGINES AND GENERATOR.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Lifesaving
Issued 17 May 1990 Resolved
PROVIDE PROPER STOWAGE FOR SECOND DECK PFDS.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 17 May 1990 Resolved
PROVIDE A FLASHLIGHT FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Documentation
Issued 17 May 1990 Resolved
MOUNT CERTIFICATE OF DOCUMENTATION, STABILITY LETTER, AND COI.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Lifesaving
Issued 17 May 1990 Resolved
REPAIR/REPLACE WATERLIGHT.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.