MAURY USCG vessel records Sign in
← All vessels

PINE

PINE is a 1990 freight ship. The Coast Guard has recorded 32 inspections since 1990, most recently in July 2018, along with 10 deficiencies and 5 operational controls, 1 with no removal date recorded.

Records from 1990 to 2018. Most recent: inspection, 12 July 2018.

Built
1990
Last inspected
12 July 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8908765 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
348103
Flag
MARSHALL ISLANDS
—
Maury page id
psix-348103

Inspections, by type

…with no type recorded18
Years with a record 14 calendar years (1990–2018)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it39145 - Simplified, Gross Ton
39145 - Convention (Subpart B), Gross Ton
16899 - Simplified, Net Ton
16899 - Convention (Subpart B), Net Ton
42968 - Dead Weight, Ton
52511 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

12 July 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6474094
6 July 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6469669
23 May 2018 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6417088
28 March 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6376753
21 August 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6247259
21 August 2017 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6247450
3 July 2017 Ballast Water Examination · ISPS III Exam · NPV Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6189322
30 January 2017 Administrative Inspection · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6079716
26 January 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6078069
21 January 2017 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6074425
20 January 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6073875
21 September 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6006557
20 September 2016 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6005229
1 August 2016 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5952236
31 May 2016 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5886260
6 October 2014 Ballast Water Examination · COE-Dockside · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4991836
4 June 2014 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4879279
26 March 2014 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4821659
20 August 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2753557
25 July 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2724192
9 June 2006 ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2675000
23 August 2004 PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2174009
12 October 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1688865
26 June 2001 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 291268
18 July 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 393604
4 November 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 384509
18 March 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 376379
22 December 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 490958
6 November 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 354061
7 December 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 347515
6 January 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 537561
7 May 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 336940

Deficiency record · 10

Lifesaving › Buoyant Apparatus › Float Free
Issued 6 October 2014 Resolved
1671: Every ship shall be provided with an EPIRB capable of floating free if the ship sinks and being automatically activated when afloat. The vessel's EPIRB was found to be fitted with a hydrostatic release unit certified for liferaft only. 74SOLAS (97cons.) IV/7.1.6.4 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2014
Resolution: Hydrostatic release unit certified for liferaft only was replaced by a hydrostatic relase unit certified for EPIRB.
Operations/Management › Pollution › Control of Garbage
Issued 26 March 2014 Resolved
2120- GARBAGE- DISCHARGE OF ALL GARBAGE INTO THE SEA IS PROHIBITED. GARBAGE WAS FOUND BEING DISCHARGED INTO THE SEA. RECOMMEND AUDIT OF GARBAGE MANAGEMENT PLAN. MARPOL 73/78 ANNEX V REG 3.1
Action required: 705 - Other - as specified
Due 26 March 2014
Resolved 4 June 2014
Resolution: Vessel submitted audit report attesting to the correction of the deficeincy.
Engineering › Lubricating Oil Service System › Piping
Issued 9 June 2006 Resolved
Water supply line leading to the steam tracing line on the lube oil settling tank leaking. Repair/Replace to the satisfaction of the attending Coast Guard Marine Inspector. SOLAS Ch. II-1 / REG 11.1
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2006
Resolution: Received Class Report attesting to repairs being made.
Navigation › Piloting/Steering › Marine Charts
Issued 9 June 2006 Resolved
Chart of the Gulf of Mexico and Tidal Current Table missing. Both must be on board prior to departure from the Port of Mobile.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 July 2006
Resolution: Received Class Report attesting to repairs being made.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 5 June 2006 Resolved
Emergency Fire Pump leaking excessively repair/replace packing to the satisfaction of classification society. SOLAS Ch. II-1 / Reg 11.1
Condition: Unknown
Due 5 July 2006
Resolved 23 July 2006
Resolution: Received Class Report attesting to repairs being made.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 5 June 2006 Resolved
Main Fire Pump at bottom, left of ladderway leaking excessively, repair/replace packing to the satisfaction of classification society. SOLAS II-1 / Reg. 11.1
Condition: Unknown
Due 5 July 2006
Resolved 23 July 2006
Resolution: Received Class Report attesting to repairs being made.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 August 2004 Resolved
Place nonconductive matting on deck in way of all high voltage switch panels in engine room and forecastle. 74SOLAS CH-II-1/45. Action 70c.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2004
Resolved 23 August 2006
Resolution: Nonconductive matting on deck in front of switch panels has been installed.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Discharge Hose
Issued 23 August 2004 Resolved
Re-new semi-portable fire extinguisher hose for unti on primary generator deck. 74 SOLAS CH II-2/6. Action 70c.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 31 August 2004
Resolved 23 August 2006
Resolution: Semi-portable fire extinguisher hose has been replaced.
Fire Fighting › Ventilation Systems › Ducts
Issued 23 August 2004 Resolved
Exercise and ensure readiness all ventilation dampers in engine room. Replace/renew ducting on starboard side near MSD where wasted. Remove temporary duct work and properly repair ducting where compromised in way of compressor air drying unit. 74 SOLAS CH-II-2/16. Action: 70a.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2004
Resolved 23 August 2006
Resolution: Temporary duct work has been repaired.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 August 2004 Resolved
Re-new salt water cooling pipe starboard side adjacent to MDE cylinders #1 & #2 near throttle platform. 74 SOLAS CH II-1/26. Action 70a.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2004
Resolved 23 August 2006
Resolution: Salt water cooling pipe has been renewed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.