Records from 2001 to 2024. Most recent: inspection, 5 February 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 12 August 2002
Resolved
Provide [name withheld] the Minimum Safe Manning Document.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2002
Electrical
Issued 29 November 2001
Resolved
Replace / Prove operation of electrical start system for emergency generator. Repair exhaust leak and holed/wasted fire main piping.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Documentation
Issued 29 November 2001
Resolved
Provide Panamanian radio station license.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Fire Fighting
Issued 29 November 2001
Resolved
Correct Fire control plan to match vessel.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Fire Fighting
Issued 29 November 2001
Resolved
Service and replace all portable extinguishers.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Fire Fighting
Issued 29 November 2001
Resolved
Provide period of service or service fixed co2 systems.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Construction/Loadline
Issued 29 November 2001
Resolved
Provide test procedures, demonstrate/prove proper operation of ows, in accordance w/Marpol.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Electrical
Issued 29 November 2001
Resolved
Provide non-conductive mats and handrails in front of main switchboards.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Fire Fighting
Issued 29 November 2001
Resolved
Provide SOLAS approved fire hose nozzles throughout vessel.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Electrical
Issued 29 November 2001
Resolved
Correct all electrical hazards in accomodations and service spaces.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Fire Fighting
Issued 29 November 2001
Resolved
Provide fire hoses in engine room for two (2) fire hydrants.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Engineering
Issued 29 November 2001
Resolved
Replace / Repair in kind engine room ventilation to prelude oil accummulation.
Condition: Unknown
Due 29 November 2001
Resolved 5 February 2024
Resolution: 5Feb2024: Vessel def's were cleared in activity #1639966 narrative but not properly cleared in MISLE.I cleared open deficiencies from activity 293514 that had had not been closed.
[name withheld]
Navigation
Issued 29 November 2001
Resolved
Align rudder angle indicators w/ rudder stock.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Accommodation/Occupational Safety
Issued 29 November 2001
Resolved
Remove all cargo from accomodation spaces.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Lifesaving
Issued 29 November 2001
Resolved
Prove operation of all Ring bouy lights.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Navigation
Issued 29 November 2001
Resolved
Provide US Coast Pilot [name withheld], and Coast Guard Light list.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Documentation
Issued 29 November 2001
Resolved
Provide correct crew list.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Lifesaving
Issued 29 November 2001
Resolved
Place retro-reflective tape on bottom of lifeboat.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Navigation
Issued 29 November 2001
Resolved
Prove proper operation and class report for GMDSS.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Navigation
Issued 29 November 2001
Resolved
Provide SOLAS Exemption Certificate for Radio Direction Finder.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Documentation
Issued 29 November 2001
Resolved
Provide a SOLAS Training Manual that is in the language of the crew and that reflects ship specific equipment.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Documentation
Issued 29 November 2001
Resolved
Provide updated Garbage Management Plan.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Documentation
Issued 29 November 2001
Resolved
Provide proper log entries for Emergency Steering Drills.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Documentation
Issued 29 November 2001
Resolved
Provide updated SOPEP with local and owner contacts.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Documentation
Issued 29 November 2001
Resolved
Provide proper log entries in Oil Record Book.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Documentation
Issued 29 November 2001
Resolved
Provide proper Oil Transfer Procedures prior to transfering fuel in U.S.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Documentation
Issued 29 November 2001
Resolved
Provide MARPOL and US Pollution Placard.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Lifesaving
Issued 29 November 2001
Resolved
Conduct fire, abandon ship and man overboard drills in presence of USCG Marine Inspectors.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Documentation
Issued 29 November 2001
Resolved
Provide all officers and crews license IAW Safe Manning Certificate.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Engineering
Issued 29 November 2001
Resolved
Repair flame screens on all oil tank vents.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Electrical
Issued 29 November 2001
Resolved
Replace missing light guards throughout vessel.
Condition: Unknown
Due 29 November 2001
Resolved 5 February 2024
Resolution: 5Feb2024: Vessel def's were cleared in activity #1639966 narrative but not properly cleared in MISLE.I cleared open deficiencies from activity 293514 that had had not been closed.
[name withheld]
Lifesaving
Issued 29 November 2001
Resolved
Remove flammable materials from water closet, aft of crew mess.
Condition: Unknown
Due 29 November 2001
Resolved 29 November 2001
Electrical › Electric Generation Source (emergency)
Issued 26 November 2001
Resolved
Provide repairs to the emergency generator
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2002
Resolution: Emergency Generator tested Sat.
Personnel › Manning/Qualifications
Issued 26 November 2001
Resolved
Provide licensed Chief Engineer in accordance with the Minimum Safe Manning Cert. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2002
Resolution: Chief Engineer had necessary license and certificates.
Engineering › Generator (propulsion-electric)
Issued 26 November 2001
Resolved
Provide means for safe start of #1 generator. LEGACY COMPONENT DESC: Switch
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2002
Resolution: New starter and starting switch was installed and tested Sat.
Engineering › Generator (propulsion-electric)
Issued 26 November 2001
Resolved
Replace generator breaker switch in center switchboard. LEGACY COMPONENT DESC: Circuit Board
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2002
Resolution: New switch was installed.