Records from 2016 to 2026. Most recent: inspection, 17 April 2026.
Documentation record
Registered dimensions (L × B × D)58.0 ft × 16.0 ft × 7.0 ft
Registered tonnagegross 43 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSLEEPY CREEK BOAT WORKS · MARSHALLBERG, NC, UNITED STATES · built 1990
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portVIRGINIA BEACH, VA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 29 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Simplified, Gross Ton
34 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 26
17 April 2026
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8350357
1 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8103197
13 November 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8030013
8 April 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7890666
9 September 2023
Type not recorded
No type recorded · USCGC SEAHAWK (WPB 87323) · USCG Southeast District (CGD-SE) · Activity 7814736
16 May 2023
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7690724
10 April 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7665654
7 November 2022
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7590766
13 April 2022
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7421033
17 May 2021
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7199210
21 April 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7179913
12 April 2021
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7173868
9 April 2021
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7167625
18 November 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7097151
9 June 2020
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6968967
26 June 2019
Type not recorded
No type recorded · USCGC HAWK (WPB 87355) · USCG Heartland District (CGD-H) · Activity 6726103
9 April 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6655916
10 January 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6607323
6 December 2018
Simplified Stability Test · In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6591023
20 June 2018
Type not recorded
No type recorded · USCGC DOLPHIN (WPB 87354) · USCG Heartland District (CGD-H) · Activity 6463937
9 April 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6383601
17 April 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6126402
11 April 2017
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6112404
16 March 2017
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6105872
12 January 2017
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6069076
12 April 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5846860
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 April 2025
Resolved
Irrespective of build date, a vessel to which this subchapter applies must meet 181.450 if it is operating on a Coastwise or Oceans route. Vessels must have an interconnected fire detection system installed in all enclosed areas where passengers and crew have routine access. An interconnected detection and alarm system must consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217; be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system; contain an independent power source; and alarm on low power. Vessel did not have interconnected smoke detection system.
//46 CFR 175.110(c)//
//46 CFR 181.405(c)//
//46 CFR 181.450(a)//
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 30 April 2025
Resolution: Tested interconnected smoke detection system installation and verified it met UL 217.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2025
Resolved
In systems and applications where flexible hoses are permitted to be clamped: double hose clamping is required where practicable. Single hose clamping was observed on the port and starboard raw water cooling to exhaust.
//46 CFR 182.410(d)//
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2025
Resolved 9 April 2025
Resolution: Received objective evidence of installed clamps.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 April 2024
Resolved
For a vessel described by 46 CFR 175.110(c), the training program in paragraph (a) of this section must address firefighting proficiency and must include, but need not be limited to—fire fighting drills and training, and emergency egress training. There were no records of the crew training.
46 CFR 185.420(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 16 April 2024
Resolution: Vessel started new log capturing training, drills, etc.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 April 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 23 April 2024
Resolution: All publications and charts are updated.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2024
Resolved
The number and identification of the lifesaving equipment items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Letters and numbers must be at least 2 in. high. The adult and child life jacket markings have missing letters on the stowage location.
46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 16 April 2024
Resolution: Vessel marked the adult and child life jacket stowage locations.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2024
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. The portable fire extinguisher near the operating station was not clearly visible and the label was on an adjacent stowage compartment.
46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2024
Resolved 16 April 2024
Resolution: The portable fire extingisher stowage location at the operation station is marked/labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 April 2024
Resolved
A vessel must carry one floating water light. The water light attached to the ring buoy did not illuminate when actuated. The battery was replaced with an approved type and tested satisfactorily in the presence of the CG Marine Inspector.
46 CFR 180.70(d)
Action required: 10 - Deficiency Rectified
Resolved 8 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2024
Resolved
Each life jacket carried on a vessel on oceans route, must have a life jacket light approved in accordance with § 161.012 in subchapter Q of this chapter. One adult life jacket and two child life jackets did not have working lights. The adult received a satisfactory replacement light and the two child lifejackets were taken out of service.
46 CFR 180.75(a)
Action required: 10 - Deficiency Rectified
Resolved 8 April 2024
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 11 April 2023
Resolved
A vessel must comply with the applicable requirements for any radio... installations including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission..
Vessel does not have an MF radio installed. Vessel must apply for FCC waiver to operate 20-100NM from shore with VHF and satellite phone. Vessel is restricted to 20NM from shore until waiver is granted.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 May 2023
Resolution: Vessel installed SSB
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 April 2021
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed hazardous places such as gears, machinery, etc. Port and starboard shafts are not protected by a cover, guard or rail.
Action required: 705 - Other - as specified
Due 21 July 2021
Resolved 17 May 2021
Resolution: Operator had installed suitable guards over port and starboard shafts.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 9 April 2021
Resolved
Exposed hazards such as gears and rotating machinery must be properly protected by a cover or rail. Port and stbd engines had exposed hazards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2021
Resolved 21 April 2021
Resolution: Cleared and reissued separate def for exposed hazard caused by main engines' shafts. See activity 7179913.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 June 2020
Resolved
Vessel must comply with FCC vessel safety certificate. Vessel's safety certificate expired. 46 CFR184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 18 June 2020
Resolution: Vessel installed FCC approved radio equipment and obtained a FCC Vessel Safety Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 June 2020
Resolved
Vessel's life raft must be of float free arrangement. Hydrostatic release installed upside down. 46 CFR 180.130
Action required: 10 - Deficiency Rectified
Due 9 June 2020
Resolved 9 June 2020
Resolution: Crew member installed hydrostatic release correctly.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 9 June 2020
Resolved
Vessel must have mounted emergency instructions in the event of a fire. Vessel needs to post instructions for fixed extinguishing system. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 17 June 2020
Resolution: Vessel posted instruction for operating fire system.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2019
Resolved
All cable wires must be installed with metal supports to avoid chafing and damage. Bilge float alarm in lazarette has a junction box that is not mounted. Repair to satisfaction of Coast Guard Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 15 April 2019
Resolution: Operator mounted new junction box.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 April 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts. Vessel charts have not been updated in 4 years. Purchase new or update current charts.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 23 April 2019
Resolved 15 April 2019
Resolution: Operator purchased new, updated charts
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 9 April 2018
Resolved
Vessel restricted to operating within one nautical mile from shore. Vessel must comply with applicable FCC requirements. Master could not provide Marine Radio Operator Permit.
46CFR184.502
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2018
Resolved 11 April 2018
Resolution: Master provided proof of his Marine Radio Operator Permit; cleared CG-835 item# 1.
Engineering › Bilge Water Management System › Pump
Issued 9 April 2018
Resolved
Vessel shall be provided with a satisfactory arrangement for draining any watertight compartment. Vessels gray water pump and associated line are inoperable. Repair to the satisfaction of the attending Marine Inspector.
46CFR182.25-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2018
Resolved 11 April 2018
Resolution: Vessel repaired gray water pump and associated piping; cleared CG-835 item# 2.
Communications › Radio Communications › VHF Radiotelephone
Issued 11 April 2017
Resolved
Emergency broadcast placard was not posted by the radiotelephone. Post IAW 45 CFR 184.510 instructions.
Due 11 May 2017
Resolved 17 April 2017
Resolution: Sent Picture of mounted placcard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 April 2017
Resolved
Medical kit missing required items. Replace missing items or kit entirely.
Due 11 May 2017
Resolved 17 April 2017
Resolution: Sent picture of new USCG certified first aid kit.