Documentation record
Registered dimensions (L × B × D)71.0 ft × 24.0 ft × 8.5 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)71.0 ft × 24.0 ft × 8.5 ft
ITC tonnagegross 181 / net 64
BuilderALUMINUM BOATS INC · JEAN LAFITTE, LA, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORTLAND, OR
Endorsements, as the file codes themcw_un
DocumentationValid · issued 1 July 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it181 - Convention (Subpart B), Gross Ton
91 - Regulatory (Subpart C or D), Gross Ton
64 - Convention (Subpart B), Net Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 18 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
26 March 2026
COI Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8332384
6 January 2026
Internal Structural Exam · Drydock Exam · Vessel Attendance
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8312379
20 March 2025
Annual Inspection · DAPI Audit
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8097236
13 March 2025
In-Service Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8094097
7 March 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7876232
9 May 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7683893
23 March 2023
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7655244
17 March 2022
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7412567
30 December 2021
Examination of Repairs · Plan Review "T" Boat
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7373950
16 March 2021
COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7148460
23 February 2021
Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7143683
5 May 2020
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6950062
8 April 2019
Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6661533
7 March 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6638816
20 December 2018
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6601515
8 March 2018
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6377637
23 March 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6108453
10 March 2016
COI Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5826939
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 May 2020
Resolved
The starboard generator exhaust pipe was found leaking exhaust fumes into the steering compartment. Make permanent repairs to the exhaust pipe to the satisfaction of the local OCMI and prior to the carriage of passengers. 46 CFR 182.20-20(Old T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Observed satisfactory repairs to exhaust piping.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 May 2020
Resolved
The child and adult life jackets on the top (Star) deck were not stowed separately. Ensure child life jackets are marked and stowed separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets to the satisfaction of the local OCMI and prior to the carriage of passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Observed satisfactory segregation and labeling of child & adult PFDs.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 5 May 2020
Resolved
The alcohol test strips on board the vessel were found expired. Provide sufficient alcohol testing equipment to test the entire crew in the event of a marine casualty.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2020
Resolution: Observed new alcohol swabs placed onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 March 2019
Resolved
AB02 - Repair inadequate weld on bilge piping on port side salon space void. During all cruises with passengers on board between 08Apr19 and now, check this void every hour.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2019
Resolved 8 April 2019
Resolution: Adequate repairs made.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 March 2019
Resolved
AB01 - Install shunt trip device for electric oven in galley within thirty days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2019
Resolved 12 April 2019
Resolution: Shunt trip device installed and verified in working order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 December 2018
Resolved
Prior to carrying passengers prove proper operation of the port engine to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 January 2019
Resolved 26 December 2018
Resolution: Conducted satisfactort U?W test. Port engine maintains proper operating temp.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 March 2016
Resolved
Expired
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 March 2016
Resolution: Vessel completed payment to the NVDC for COD and information was updated in MISLE as to the vessel having a valid Coastwise endorsement.