Records from 1990 to 2010. Most recent: inspection, 17 December 2010.
Inspection history · 27
17 December 2010
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3912607
9 December 2010
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3905115
8 December 2010
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3904045
24 January 2007
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2861016
20 January 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2859112
16 September 2006
Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2775309
12 December 2005
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2549826
7 August 2005
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2448067
20 June 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2398191
29 May 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2372284
25 May 2005
ISPS II Exam · ILO-147 Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2368011
20 December 2002
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1721628
12 December 2002
Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1717256
15 March 2001
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 640174
15 March 2001
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 685282
18 November 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 422774
27 August 1997
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 712200
29 July 1997
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 406310
1 September 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 394666
23 May 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 358467
9 November 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 354526
24 May 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 351048
21 January 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 348243
17 January 1992
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 348254
15 May 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 473153
13 May 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 525035
5 September 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 339290
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 24 January 2007
Resolved
PROVIDE EXPIRATION DATES FOR THE LIFE JACKET LIGHTS IN A LOG BOOK OR ON THE LIGHT OR CHANGE ALL BATTERIES ANNUALLY LSA CODE
RECTIFY DEFICIENCIES PRIOR TO NEXT US PORT AFTER SAILING FOREIGN
Action required: 705 - Other - as specified
Due 24 February 2007
Resolved 9 December 2010
Resolution: Class report attested to deficiency being corrected.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 24 January 2007
Resolved
EMERGENCY FIRE PUMP CONTROL BOX HAS A FLICKERING LIGHT WHILE PUMP IS RUNNING INDICATING A SHORT CIRCUT. SOLAS 74 AND I/II
RECTIFY DEFICIENCIES PRIOR TO NEXT US PORT AFTER SAILING FOREIGN
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 February 2007
Resolved 9 December 2010
Resolution: Class report attested to deficiency being corrected.
Lifesaving › Inflatable Liferafts › Painter
Issued 24 January 2007
Resolved
BOTH 25 PERSON LIFE RAFT PAINTERS FOUND TIED TO VESSEL VICE HAMMER WEAK LINK. NOW CORRRECTED
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 January 2007
Resolved 24 January 2007
Resolution: PAINTERS WERE INSTALLED CORRECTLY
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 24 January 2007
Resolved
BATTERY BANK #1 TO EMERGENCY GENERATOR FOUND IN DISCHARGEED CONDITION SOLAS 74 AND I/II
RECTIFY DEFICIENCIES PRIOR TO NEXT US PORT AFTER SAILING FOREIGN
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 February 2007
Resolved 9 December 2010
Resolution: Class report attested to deficiency being corrected.
Engineering › Bilge Water Management System › Piping
Issued 24 January 2007
Resolved
PROVE PROPER OPERTATION OF THE OILY WATER SEPARATING EQUIPMENT WHERE THE ANTI SIPHON DEVICE WAS FOUND WITH A VALVE FITTER AND IN TNE CLOSED POSITION. A TUBE HAS BEEN ADDED THAT IS NOT SHOWN ON THE DRAWING. MARPOL 73/78 I
RECTIFY DEFICIENCIES PRIOR TO NEXT US PORT AFTER SAILING FOREIGN
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2007
Resolved 9 December 2010
Resolution: Class report attested to deficiency being corrected.
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 24 January 2007
Resolved
A GYRO-COMPASS HEADING REPEATER IS MISSING AT THE EMERGENCY STEERING STATION. SOLAS 74 AND V/19.2.6.2
RECTIFY DEFICIENCIES PRIOR TO NEXT US PORT AFTER SAILING FOREIGN
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 February 2007
Resolved 9 December 2010
Resolution: Class report attested to deficiency being corrected.
Stability › Weathertight Integrity › General
Issued 24 January 2007
Resolved
THE WEATHER DOOR STARBOARD SIDE, BETWEEN ACCOMMODATIONAND POOP DECK WILL NOT DOG CLOSED. SOLAS 74 AND I/II
RECTIFY DEFICIENCIES PRIOR TO NEXT US PORT AFTER SAILING FOREIGN
Action required: 705 - Other - as specified
Due 24 February 2007
Resolved 9 December 2010
Resolution: Class report attested to deficiency being corrected.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 24 January 2007
Resolved
THE DOORS TO THE STEERING ROOM FROM THE ENGINE ROOM WERE FOUND BLOCKED OPEN. NOW REPAIRED AND CLOSED WITH THE EXCEPTION OF THE LATCH. SOLAS 74 AND I/II
RECTIFY DEFICIENCIES PRIOR TO NEXT US PORT AFTER SAILING FOREIGN
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 February 2007
Resolved 9 December 2010
Resolution: Class report attested to deficiency being corrected.
Engineering › Lubricating Oil Service System › Gauge
Issued 24 January 2007
Resolved
BOTH SIGHT GLASSES TO THE STEERING GEAR PORT AND STARBOARD LEAK OIL. SOLAS 74 AND I/II
RECTIFY DEFICIENCIES PRIOR TO NEXT US PORT AFTER SAILING FOREIGN
Action required: 705 - Other - as specified
Due 24 February 2007
Resolved 9 December 2010
Resolution: Class report attested to deficiency being corrected.
Fire Fighting › Fire Hoses › Condition
Issued 16 September 2006
Resolved
Fire hose number 9 is in poor condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2006
Resolution: Fire hose number 9 was replaced.
Personnel › Training › Fire Fighting Basic
Issued 16 September 2006
Resolved
Fire drill was unsatisfactory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2006
Resolution: Fire drill was satisfactory.
Personnel › Training › Lifeboatman
Issued 16 September 2006
Resolved
Abandon ship drill unsatisfactory.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2006
Resolution: Abandon ship drill was satisfactory.
Electrical › Electric Generation Source (emergency) › Generator
Issued 25 May 2005
Resolved
Heater for emergency generator inoperable. Repair or replace heater to the satisfaction of a USCG inspector.
Action required: 705 - Other - as specified
Due 25 June 2005
Resolved 10 August 2005
Documentation › Certificates/Documents › IOPP Certificate
Issued 12 December 2002
Resolved
Include all of the tanks that the vessel uses to process sludge in block 3.1 of the IOPP and change the incinerator capacity to 20x10^4 kcal/hour. MARPOL 73/78
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2005
Resolution: IOPP updated
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 December 2002
Resolved
Repair door latch at engine room to steering room and remove all hold backs where the doors are required to be self closing. SOLAS 74amd II-2/47.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2005
Resolution: Door repaired and all hold backs removed
Lifesaving › Lifejacket/PFD (General)
Issued 12 December 2002
Resolved
Provide an external marking on the life jacket lights with the battery expiration or change the batteries annually. LSA Code 1.2.3 LEGACY COMPONENT DESC: Lights
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 December 2002
Resolution: Vessel placed labels on the exterior of the lights which showed the batteries'' expiration date.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 12 December 2002
Resolved
Update the fire control plan to include EEBD locations, paint locker sprinkler valve, paint locker door location and foc'sle deck hatch. SOLAS 74amd I/11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2005
Resolution: Fire control plan properly updated
Operations/Management › Pollution › Compliance with Transfer Procedures
Issued 12 December 2002
Resolved
Update the oil transfer procedure. 33 CFR 155.750
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2005
Resolution: Oil transfer procedures properly updated
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 December 2002
Resolved
Vessel issued Letter of Deviation for inoperative Radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2005
Resolution: Radar operating properly
Deck/Cargo
Issued 29 July 1997
Resolved
LEAKING HATCH COVER #4 HOLD STARBORD SIDE. MARPOL.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Electrical
Issued 29 July 1997
Resolved
NO NON CONDUCTIVE MATT IN FRONT OF ELECRICAL SWITCHBOARD FOR EMERGENCY _x001C_ GENERATOR. SOLAS CHII-1,REG 45.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Lifesaving
Issued 29 July 1997
Resolved
BATTERIES FOR IMMERSION SUITS LIGHTS ARE EXPIRED. SOLAS CH-III REG 33.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Navigation
Issued 29 July 1997
Resolved
U.S. CHART 18656 NOT CURRENTLY CORRECTED. 33 CFR 164. ISSUED LETTER OF _x001C_ WARNING.
Condition: Unknown
Due 29 July 1997
Resolved 18 August 1997