MELEKAI is a 1990 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1990, most recently in March 2026, along with 151 deficiencies and 3 operational controls.

Records from 1990 to 2026. Most recent: inspection, 10 March 2026.

Built
1990
Last inspected
10 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD6591
348855
Flag
UNITED STATES
—
Maury page id
psix-348855

Inspections, by type

…with no type recorded3
Years with a record 32 calendar years (1990–2026)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 59

10 March 2026 Deficiency Check · Administrative Inspection · Drydock Exam · Vessel Attendance
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8314573
8 December 2025 Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8279554
20 November 2025 Annual Inspection · Vessel Attendance · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8262807
18 November 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8037792
14 March 2024 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7870999
13 November 2023 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7820944
19 July 2022 Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7512216
26 May 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7460206
25 April 2022 Simplified Stability Test
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7438974
17 August 2021 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7285149
1 July 2020 Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6994033
2 March 2020 Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6918984
29 May 2019 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6697539
24 May 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6421998
27 March 2018 Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6379155
19 June 2017 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6182824
19 December 2016 Damage Survey · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6060265
19 December 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6065262
21 March 2016 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5834730
1 March 2016 Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5822924
12 June 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4892650
5 March 2014 Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4809421
17 May 2012 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4314179
19 May 2008 Deficiency Check · DAPI Audit · Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3211421
29 March 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2876125
26 May 2006 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2685264
7 April 2006 COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2619446
12 May 2005 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2357207
8 July 2004 Annual Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2106437
11 May 2004 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2064931
27 June 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1827890
2 July 2002 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1637391
21 May 2002 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1617279
24 April 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1062192
20 April 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 718361
13 April 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1066469
10 April 2001 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1373424
14 June 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365821
26 May 2000 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1437730
19 July 1999 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1375890
14 June 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1470987
3 May 1999 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 793230
2 December 1998 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1375606
30 April 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1413357
1 May 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383530
3 December 1996 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367980
17 May 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1383248
7 May 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359107
15 June 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 877210
9 May 1995 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1367377
7 December 1994 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380119
10 May 1994 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353567
7 June 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 841840
10 May 1993 COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1143833
2 December 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1140756
11 August 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1265515
11 May 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 958091
26 June 1991 Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1226958
16 May 1990 Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1241807

Deficiency record · 151

02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 10 March 2026 Resolved
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] found under aft port hull. Grind back and restore to the satisfaction of the attending marine inspector as discussed, prior to receiving credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 26 March 2026
Resolution: Final inspection of repair found satisfactory to attending marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2025 Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs. This subpart summarizes the responsibilities of credentialed mariners, marine employers, MRO, SAP and other chemical testing service providers in 49 CFR part 40. The regulations in 49 CFR part 40 should be consulted to determine the specific procedures which must be established and utilized. Sea Eagle Diving Adventure Corporation drug testing program is not in compliance with Title 49, CFR Part 40 based on the company Drug and Alcohol Program audit on December 8, 2025. Bring program into compliance to satisfaction of attending marine inspector. 46 CFR 16.113(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 8 April 2026
Resolution: Corrected
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2025 Resolved
No marine employer may engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Breeze Hawaii dive masters and snorkel guides serve as crew members in a safety sensitive position that directly affect the safe operation of the vessel without a negative pre-employment test and enrollment in a random drug testing program as described by 46 CFR 16.230. (1) Ensure Breeze Hawaii dive or snorkel employees do not serve in a safety sensitive position as a crew member; or (2) Provide Breeze Hawaii employees pre-employment drug test and provide results from a qualified Medical Review Officer (MRO) to the attending marine inspector; and (3) Enroll Breeze Hawaii employees in a chemical testing program that meets the requirements of 46 CFR 16.230 and provide objective evidence of enrollment to the satisfaction of the attending marine inspector by December 15, 2025. 46 CFR 16.210(a)
Action required: 705 - Other - as specified
Resolved 29 December 2025
Resolution: Received pre employment testing for Breeze Hawaii members.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 November 2025 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. Terminal board on bridge is unsupported and susceptible to ship's motions. Properly mount terminal board to the satisfaction of attending marine inspector. 46 CFR 183.310 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2025
Resolved 5 December 2025
Resolution: MI verified terminal board on bridge to be permanently mounted. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 November 2025 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this sub chapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Bilge piping in head as broken away at thru-hull connection. Replace thru-hull connection on piping to the satisfaction of attending marine inspector. 46 CFR 176.800
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2025
Resolved 5 December 2025
Resolution: MI verified thru-hull connection in head to be replaced. Witnessed operational test of hand pump. All sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 21 November 2025 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be dry docked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Exposed wood on the port crossbeam observed to be wet and rotting. Submit temporary repair proposal for review. Once approved, complete the repairs to the satisfaction of attending marine inspector. 46 CFR 176.600 (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2025
Resolved 10 March 2026
Resolution: Physically verified on site during most recent drydock, found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 November 2025 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. The portable fire extinguishers stored inside the forward storage space signage indicating their location is not legible. Replace signage to the satisfaction of attending marine inspector. 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2025
Resolved 5 December 2025
Resolution: MI verified new signage had been posted for location of portable fire extinguishers. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2025 Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). Fixed hand pumps in the port midship compartment, starboard forward compartment, and starboard midship compartment were inoperable. Repair. Prove satisfactory operation in the presence of the attending marine inspector. 46 CFR 182.25-10 (Old T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2025
Resolution: Repaired and demonstrated operation of bilge pumps.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 November 2025 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Port bow rail mount deck material has rotted and does not provide protection for passengers. Submit repair proposal for review and approval by attending marine inspector. Once approved, complete repairs to satisfaction of attending marine inspector. 46 CFR 177.35-1 (Old T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 10 March 2026
Resolution: Physically verified on site during most recent drydock, found satisfactory.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 20 November 2025 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this sub chapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Fuel hose for both outboards not double hose clamped when fitting has enough room for two clamps. Add extra hose clamp on fuel hose for both outboards to satisfaction of attending marine inspector. 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 5 December 2025
Resolution: MI verified additional hose clamps addded to each outboard fuel hoses. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 November 2025 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the commandant. Blade type fuses and holder installed, replace with UL approved cartridge type fuses and holder to satisfaction of attending marine inspector. 46 CFR 183.380 (l)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 5 December 2025
Resolution: MI verified blade type fuses had been replaced with UL-approved cartridge fuses. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 November 2025 Resolved
Battery chargers must have an ammeter connected in the charging circuit. Ammeter not installed. Install an ammeter in charging circuit or replace with battery charger with ammeter built in or remove to the satisfaction of the attending marine inspector. 46 CFR 183.350 (f)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 5 December 2025
Resolution: MI verified battery charger had been removed. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 20 November 2025 Resolved
A portable or temporary electrical cord must be constructed and used in compliance with the requirements of 46 CFR 111.60-13. Prove existing flexible extension cable used for battery charging is: 1) UL62 approved; 2) 18 AWG; 3) outlet is GFCI; 4) connection is made to reduce tension as described in 46 CFR 111.60-13(f) to the satisfaction of the attending marine inspector. 46 CFR 183.340 (r)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 5 December 2025
Resolution: MI verified extension cord had been removed. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 November 2025 Resolved
The masthead light, or the all-round light described in Rule 23(d)(§ 83.23(d) of this chapter), of a power-driven vessel of less than 12 meters in length shall be carried at least one meter higher than the sidelights. The aft center all-around white light is lower than one meter than the sidelights. Raise to meet the regulation to the satisfaction of the attending marine inspector. 33 CFR 84.02(d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 5 December 2025
Resolution: MI measured height of aft-masthead light in relation to sidelights. Height is over 1 meter. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 November 2025 Resolved
Each life jacket kept in a stowage container must be readily available. Life jacket stowage areas had other items stowed in them. Remove additional stored items in life jacket storage areas to the satisfaction of the attending marine inspector. 46 CFR 180.78(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 5 December 2025
Resolution: MI verified removal of additional items in lifejacket stowage location. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 November 2025 Resolved
A vessel is inspected for compliance with the standards required by this sub chapter. Machinery, equipment, materials, and arrangements not covered by standards in this sub chapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. There are five wires connected to the stbd battery terminal negative and the standard is a maximum of four connections. Remove one wire connection from the battery negative terminal and use an alternate means of connecting it to the negative battery terminal to the satisfaction of the attending marine inspector. 46 CFR 176.800(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 5 December 2025
Resolution: MI witnessed removal of additional wire connections from battery terminals. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 November 2025 Resolved
Each number required by § 173.15 must:(1) Be painted on or permanently attached to each side of the forward half of the vessel except as allowed by paragraph (b) or required by paragraph (c) of this section;(2) Be in plain vertical block characters of not less than 3 inches in height;(3) Contrast with the color of the background and be distinctly visible and legible;(4) Have spaces or hyphens that are equal to the width of a letter other than “I” or a number other than “1” between the letter and number groupings (Example: DC 5678 EF or DC-5678-EF); and(5) Read from left to right. Affix HA numbers to the each side of the bow to the satisfaction of the attending marine inspector. 33 CFR 173.15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 21 November 2025
Resolution: Crew permanently attached state registration number on both sides of bow.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 November 2025 Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Life buoy not in a serviceable condition. Provide an approved life buoy to the satisfaction of the attending marine inspector. 46 CFR 180.70(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 5 December 2025
Resolution: MI verified life buoy to be CG approved and 24". All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 18 November 2024 Resolved
Gages to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. STBD gage not working and port gage not visible. 46CFR182.15-5(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2024
Resolved 22 December 2024
Resolution: O/O submitted photos.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 November 2023 Resolved
Connections to batteries must be made with permanent type connectors. The battery lugs had terminals held in place with wing nuts. Replace wing nuts with permanent type connectors. 46 CFR 183.350(d)
Action required: 10 - Deficiency Rectified
Resolved 13 November 2023
Resolution: Wing nuts were removed and replaced with hex nuts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 November 2023 Resolved
Each ring buoy must be marked with with the vessel's name. The provided ring buoy was not properly marked. Properly mark the ring buoy. 46 CFR 185.604(b)
Action required: 10 - Deficiency Rectified
Resolved 13 November 2023
Resolution: Ring buoy was properly marked.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 July 2022 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. The vessel’s stern, mast, and starboard navigation lights are extinguished. 46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 23 August 2022
Resolution: Verified the proper operation of the navigation lights.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 July 2022 Resolved
An EAP training program must be conducted for the employer's crewmembers and supervisor personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer's supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. EAP supervisor did not provide documentation of training. 46 CFR 16.401(b)
Action required: 705 - Other - as specified
Resolved 22 July 2022
Resolution: Provided evidence of EAP training.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 19 July 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The first-aid kit is expired. Replace expired medication. 46 CFR 184.710
Action required: 705 - Other - as specified
Resolved 23 August 2022
Resolution: A new unexpired first-aid kit was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 July 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot [name withheld] List, tide tables, current tables, and charts of large enough scale to make safe navigation possible. Vessel requires current U.S. Coast Pilot [name withheld] List, tide tables, current tables, and up to date charts. 46 CFR 184.420(a)(1)-(5)
Action required: 705 - Other - as specified
Resolved 21 July 2022
Resolution: Vessel provided current U.S. Coast Pilot [name withheld] List, tide tables, current tables, and up to date charts.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 July 2022 Resolved
A valid certificate of number for that vessel issued by the issuing authority in the State in which the vessel is principally operated is required. State registration was not on board. 33 CFR 173.21(a)(1)
Action required: 705 - Other - as specified
Resolved 21 July 2022
Resolution: Provided documentation of state registration.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 July 2022 Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to demonstrate operation of the starboard bilge pump. Prove proper operation of the starboard bilge pump. 46 CFR 182.500(a)
Action required: 705 - Other - as specified
Resolved 23 August 2022
Resolution: Witnessed proper operation of the starboard bilge pump.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 July 2022 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. All bilge alarms not labeled. Label all bilge alarms. 46 CFR 182.530(a)
Action required: 705 - Other - as specified
Resolved 22 July 2022
Resolution: Labeling provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 March 2020 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following spaces; A space with a non-watertight hatch on the main deck. Provide high water level alarm and separate indicator for each of the 4 compartments on each side. 46 CFR 182.530 (a)&(b) 3/13/2020 - reissued from worklist item as 30 day CG-835
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2020
Resolved 17 August 2021
Resolution: Required bilge alarms were provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 March 2020 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without approval of the cognizant OCMI. Vessel is in the process of rewiring the boat. Submit changes to the electrical plan for review to the Marine Safety Center, email [email withheld] . Include [email withheld] in all email correspondence. 46 CFR 176.700 3/13/2020 - reissued from worklist item as 30 day CG-835
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2020
Resolved 25 August 2021
Resolution: An extensive comparison of the vessels approved electrical plans and the existing system was conducted and found to be compliant.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 March 2020 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Countless wires unsupported in all compartments. 46 CFR 183.340 (b)(4) 3/13/2020 - reissued from worklist item as 30 day CG-835
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2020
Resolved 1 July 2020
Resolution: Vessel supported all cables.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 March 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found many compartments. 46 CFR 183.200 3/13/2020 - reissued from worklist item as 30 day CG-835
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2020
Resolved 1 July 2020
Resolution: Vessel removed dead end wires.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 2 March 2020 Resolved
A port light must have an inside, hinged dead cover. Vessels dead covers missing closing devices in several compartments. Prove satisfactory operation. 46 CFR 179.350 3/13/2020 - reissued from worklist item as 30 day CG-835
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2020
Resolved 1 July 2020
Resolution: Vessel installed dead cover closing devices.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2020 Resolved
Vent pipes terminating on the hull exterior must be installed or equipped to prevent the accidental contamination of the fuel by water under normal operating conditions. Vessels current fuel tank vent is exposed angled up allowing rain/ sea spray into vent. 46 CFR 182.450 (d)
Action required: 705 - Other - as specified
Resolved 13 March 2020
Resolution: Vessel purchased and installed fuel vents with adequate protection from rain/ sea spray.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 March 2020 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens, corrosion resistant 30x30 mesh. One flame screen was painted over, the other was not secured. Provide adequate vent fitting. 46 CFR 182.450 (e)
Action required: 705 - Other - as specified
Resolved 13 March 2020
Resolution: Vessel purchased and installed fuel vents with flame screens.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 2 March 2020 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessels sewage vent is flex hose stuck through a hole drilled in the side of the vessel. Provide permanent, adequate venting arrangements. 46 CFR 176.800(a)
Action required: 705 - Other - as specified
Resolved 13 March 2020
Resolution: Vessel installed satisfactory venting arrangements.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 March 2020 Resolved
A vessel must be provided with bilge pumps in accordance with table 182.520(a). Electric submersible pump overboard valves need to be removed and holes plugged. 46 CFR 182.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2020
Resolved 1 July 2020
Resolution: Vessel ovbd valves removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 2 March 2020 Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction. Reinforce port forward handrail to ensure 200 lb load. 46 CFR 177.900 (b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 April 2020
Resolved 1 July 2020
Resolution: Vessel reinforced deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 March 2020 Resolved
The owner or operator shall make a vessel available for drydock examinations. Due to concerns with COVID-19, vessel was unable to complete the last 07 CG-835s issued on 13MAR2020 following drydock. Vessel rep elected to take prior to passenger CG-835 until COVID-19 concerns have passed and vessel is able to complete 07 remaining open CG-835s.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2020
Resolved 17 August 2021
Resolution: The vessel then completed a credit drydock examination on 13MAR2020 and cleared the remaining defs in July 2020 and August 2021.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 May 2019 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Visual indicator is not provided at the operating station. Provide an indicator of activation of automatic bilge pump or remove automatic bilge pumps and maintain your fixed and portable hand pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 11 June 2019
Resolution: Vessel has elected to operate only with fixed and portable hand pumps. Vessel is in accordance with Table 182.520(a) in Subchapter T.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 May 2019 Resolved
Battery chargers must have an ammeter connected in the charging circuit. Battery charger does not have an ammeter. Provide a battery charger with an ammeter.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 18 June 2019
Resolution: Ammeter was installed
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 May 2019 Resolved
A vessel not required to have a power driven fire pump must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. Vessel's fire buckets were 2 gallons and not 2 1/2. Provide 2 1/2 gallon buckets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 10 June 2019
Resolution: Received email providing proof of three 2 1/2 gallon fire buckets
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 May 2019 Resolved
When the operator on duty and in charge of transmitting systems, or performing service, maintenance or inspection functions, the license or permit document, or a photocopy thereof, or a copy of the application and PPC(s) received by the FCC, must be posted or in the operator's personal possession, and available for inspection. Operator could not provide Marine Radio Operators Permit. Provide Marine Radio Operators Permit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 18 June 2019
Resolution: Radio Operators permit was provided to MI.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 29 May 2019 Resolved
One ship station license will be granted for operation of all maritime services transmitting equipment on board a vessel. Vessel's ship station license is expired. Provide proof of valid station license.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2019
Resolved 12 June 2019
Resolution: Received copy of stationed license via email.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2019 Resolved
Vessel is not meeting the requirements of 46 CFR 16. Recommend a full DAPI Audit to be conducted
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2019
Resolved 5 July 2019
Resolution: DAPI Audit was Conducted
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 May 2019 Resolved
Based off 05JULY19 DAPI Audit, company drug and alcohol program is not in compliance with 46 CFR 16.210 and 40.25(Pre Employment testing), 46 CFR 16.401 (EAP Requirements), and 46 CFR 16.500(MIS Submission). Company has 30 Days to be found in compliance by attending Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 August 2019
Resolved 12 September 2019
Resolution: Verified DAPI program is in place including EAP. All required documents per deficiency verified.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 May 2018 Resolved
Provide servicing record for all four fire extinguishers IAW 46CFR176.810.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2018
Resolved 24 May 2018
Resolution: Vessel rep provided servicing records for fire extinguishers.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 24 May 2018 Resolved
Provide six hand red flare and six hand orange smoke distress signals IAW 46CFR180.68.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2018
Resolved 24 May 2018
Resolution: MI verified vessel had six hand red flare and six hand orange smoke distress signals.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 May 2018 Resolved
Replace lifeline on ring buoy IAW 46CFR180.70.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2018
Resolved 31 May 2018
Resolution: Verified new lifeline on ring buoy.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2018 Resolved
Provide operational first aid kit IAW 46CFR160.041.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2018
Resolved 4 June 2018
Resolution: Vessel provided new first aid kit. All sat.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 24 May 2018 Resolved
Provide two operable portable battery lights IAW 46CFR183.430.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2018
Resolved 31 May 2018
Resolution: Vessel obtained two operable portable battery lights. All sat.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 24 May 2018 Resolved
Provide up-to-date tide tables IAW 46CFR184.420.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2018
Resolved 24 May 2018
Resolution: Verified up-to-date tide tables. All sat.
Documentation › Logs/Records › Drug Test Records
Issued 24 May 2018 Resolved
Make drug and alcohol program records available for inspection IAW 46CFR16.203.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2018
Resolved 13 June 2018
Resolution: DAPI audit complete. All sat.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 March 2018 Resolved
Mount battery in port aft #4 compartment IAW 46CFR183.350.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 23 April 2018
Resolution: Battery mounted in port aft #4 compartment.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 March 2018 Resolved
Provide supports for cable and wiring in compartments #3 port and #3 starboard IAW 46CFR183.340.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 23 April 2018
Resolution: Provide supports for cable and wiring.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 March 2018 Resolved
Remove unused wire in compartment #3 starboard IAW 46CFR183.220.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 23 April 2018
Resolution: Removed unused wire.
Construction/Loadline › Hull › Side Shell
Issued 27 March 2018 Resolved
Submit repair proposal to repair port aft corner near railing IAW 46CFR176.600.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 23 April 2018
Resolution: Completed repairs.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 June 2017 Resolved
Provide updated nautical publications to include Coast Pilot [name withheld], and Tide Tables.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 28 June 2017
Resolution: Operator provided updated publications.
Operations/Management › Drills/Instruction › Fire
Issued 19 June 2017 Resolved
Make fire and abandon ship drill records available for inspection.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 31 August 2017
Resolution: Record of drills provided to marine inspector; all sat.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 19 June 2017 Resolved
Provide EPIRB testing logs.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 31 August 2017
Resolution: Record of EPIRB testing provided to inspector; all sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 June 2017 Resolved
Provide valide FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 28 August 2017
Resolution: Valid FCC Certificate received by Sector Honolulu.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 June 2017 Resolved
Provide first-aid kit.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 19 June 2017
Resolution: Operator renewed first aid kit.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 19 June 2017 Resolved
Update emergency instructions to reflect particulars of vessel.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 31 August 2017
Resolution: Emergency instructions updated to reflect vessel particulars.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 19 June 2017 Resolved
Provide flame screen for port fuel tank vent.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 31 August 2017
Resolution: Flame screen installed.
Documentation › Logs/Records › Drug Test Records
Issued 19 June 2017 Resolved
Make drug and alcohol program records available for inspection.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 19 September 2017
Resolution: Records reviewed; all sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 June 2017 Resolved
Label fuel shutoff valves IAW 46 CFR 185.608.
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 31 August 2017
Resolution: Labeling for shutoff valves provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 June 2017 Resolved
Provide documentation attesting to servicing of portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2017
Resolved 19 June 2017
Resolution: Received email documenting servicing by Oahu Fire Protection on 19 June.
Documentation › Markings/Placards › Warning Signs
Issued 21 March 2016 Resolved
Ensure durable placard posted next to radiotelephone with emergency broadcast instructions.
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 1 April 2016
Personnel › Training › Passenger Safety
Issued 21 March 2016 Resolved
Ensure log of crew training maintained and available upon request.
Action required: 705 - Other - as specified
Due 21 March 2016
Resolved 21 March 2016
Resolution: Discussed with crew, corrected on the spot.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 21 March 2016 Resolved
Ensure compliance with drug and alcohol testing requirements.
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 19 June 2017
Resolution: Re-issued on 19 June 2017.
Navigation › Piloting/Steering › Marine Charts
Issued 21 March 2016 Resolved
Ensure updated charts and pubs maintained upon the vessel.
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 23 May 2016
Resolution: Vessel rep emailed receipt, all sat.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 March 2016 Resolved
Ensure logs of fire fighting drills and training maintained and available upon request.
Action required: 705 - Other - as specified
Due 21 March 2016
Resolved 21 March 2016
Resolution: Discussed, corrected on the spot.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 March 2016 Resolved
Ensure logs of abandonship and man overboard drills and training maintained and available upon request.
Action required: 705 - Other - as specified
Due 21 March 2016
Resolved 21 March 2016
Resolution: Discussed, corrected on the spot.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 21 March 2016 Resolved
Ensure log of EPIRB monthly test maintained and available upon request.
Action required: 705 - Other - as specified
Due 21 March 2016
Resolved 21 March 2016
Resolution: Discussed, corrected on the spot.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 21 March 2016 Resolved
Ensure audible/visual indicator for bilge high level water alarm operable (port side and stbd side).
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2016
Resolved 21 March 2016
Resolution: Verified audible and visual alarms in working order.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 March 2016 Resolved
Ensure EPIRB hyrostatic release has valid installation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2016
Resolved 22 March 2016
Resolution: Verified proper installation.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 March 2016 Resolved
Replace 04 child-size lifejackets.
Action required: 705 - Other - as specified
Due 21 March 2016
Resolved 1 April 2016
Resolution: Verified replacement lifejackets.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 21 March 2016 Resolved
Replace retro-reflective material for 06 adult life-jackets.
Action required: 705 - Other - as specified
Due 28 March 2016
Resolved 1 April 2016
Resolution: Verified replacement retro-reflective material.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 12 June 2014 Resolved
Provide 14 additional adult life jackets for a total of 33. Passenger count is reduced to 17.
Due 27 June 2014
Resolved 11 May 2015
Resolution: Verified 33 adult PFDs and 4 Child PFDs onboard; all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2014 Resolved
Provide metal supports for wire runs.
Due 27 June 2014
Resolved 11 May 2015
Resolution: Verified battery cable wiring supported by metal loops.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 June 2014 Resolved
Remove or properly terminate dead end wires.
Due 27 June 2014
Resolved 18 May 2015
Resolution: No dead end wires were noted during 4th annual exam.
Communications › Radio Communications › EPIRB
Issued 12 June 2014 Resolved
Provide proof of EPIRB registration.
Due 27 June 2014
Resolved 11 May 2015
Resolution: Current registration was found onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 June 2014 Resolved
Properly mark first aid kit.
Due 27 June 2014
Resolved 11 May 2015
Resolution: Water tight box containing first aid kit was found to be properly marked.
Stability › Watertight Integrity › General
Issued 5 March 2014 Resolved
MAKE ALL WATERTIGHT BULKHEAD PENETRATIONS WATERTIGHT.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2014
Resolution: SEALED
Construction/Loadline › Hull › Side Shell
Issued 5 March 2014 Resolved
FAIR OUT MARKED AREAS OF BOTH HULLS AND RELAMINATE
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2014
Resolution: FIXED
Stability › Water on Deck › General
Issued 5 March 2014 Resolved
DRY OUT INTERNAL SPACES
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2014
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 March 2014 Resolved
TIGHTEN ALL RAILING FIXTURES
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2014
Resolution: TIGHTENED
Communications › Radio Communications › EPIRB
Issued 17 May 2012 Resolved
Provide current NOAA registration for EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2012
Communications › Radio Communications › EPIRB
Issued 17 May 2012 Resolved
Renew battery for EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2012
Communications › Radio Communications › VHF Radiotelephone
Issued 17 May 2012 Resolved
Provide current FCC radio safety certificate
Due 18 June 2012
Resolved 18 May 2012
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 17 May 2012 Resolved
Remove gas BBQ system until in compliance with 46 CFR 184.200 and ABYC
Due 18 May 2012
Resolved 8 June 2012
Resolution: Vessel will be using small disposable bottles for BBQ IAW ABYC A-30. In the future vessel plans to install permanent system IAW ABYC A-1. When they do they will contact USCG and have system inspected for compliance.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 June 2008 Resolved
Provide proof of employee awareness of company drug program
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 2 July 2008
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 June 2008 Resolved
Provide proof of substance abuse professional and employee awareness of EAP IAW 46CFR16.401
Condition: Unknown
Due 4 July 2008
Resolved 2 July 2008
Stability › Watertight Integrity › General
Issued 11 June 2008 Resolved
Provide proper stuffing materials throughout vessel IAW 46CFR183.340
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 2 July 2008
Resolution: Vessel removed rags and other materials from stuffing tubes.
Stability › Watertight Integrity › General
Issued 11 June 2008 Resolved
Make repairs to forward compartment frame STBD side IAW 46CFR182.720
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 2 July 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 11 June 2008 Resolved
Properly label locations of fire extinguishers IAW 46CFR181.500
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 July 2008
Resolved 11 July 2008
Lifesaving › Lifebuoys › Stowage
Issued 11 June 2008 Resolved
Properly affix waterlight to ringbuoy IAW 46CFR180.70
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 July 2008
Resolved 2 July 2008
Engineering › Steering Gear System › Piping
Issued 11 June 2008 Resolved
Ensure all hydraulic steering lines are kept out of the bilge IAW 46CFR182.720
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 July 2008
Resolved 2 July 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 June 2008 Resolved
Install metal supports at 24" intervals IAW 46CFR183.34
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 July 2008
Resolved 2 July 2008
Stability › Weathertight Integrity › General
Issued 15 May 2008 Resolved
Ensure all backing plates are properly installed throughout the vessel
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 11 June 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 May 2008 Resolved
Reinforce forward deck rails to ensure rails are capable of supporting 200lbs
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 11 June 2008
Stability › Watertight Integrity › General
Issued 14 May 2008 Resolved
Make repairs to indicated frame in starboard aft compartment
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 11 June 2008
Stability › Weathertight Integrity › General
Issued 14 May 2008 Resolved
Replace cracked windows on vessel
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 11 June 2008
Stability › Watertight Integrity › Weathertight Enclosure
Issued 14 May 2008 Resolved
Make hatches throughout vessel watertight
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 11 June 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 March 2007 Resolved
Deck rails on bow and around operator's station are loose. Reinforce deck rails throughout the vessel in order to withstand 200lbs, IAW 46 CFR 177.35-1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 30 April 2007
Construction/Loadline › Hull › Stringer
Issued 29 March 2007 Resolved
Stbd and port hulls forward compartment have wood rot in upper aft corners. The wing deck, forward section has angel hair visible from the port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 30 April 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 29 March 2007 Resolved
Lifesaving maintenance log and training log book unavailable for inspection, IAW 46 CFR 185.25-10.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 30 April 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 March 2007 Resolved
Secure hanging wires as high as practicle above bilges in both port and stbd hulls, IAW 46 CFR 183.05-50.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 30 April 2007
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 March 2007 Resolved
Lifebuoy lifeline deteriorated due to sun exposure. Replace lifeline, ensure buoy floats free IAW 46 CFR 180-30-1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 30 April 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 March 2007 Resolved
Make repairs to outer lining on lifejackets IAW 46 CFR 180.71.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 30 April 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 29 March 2007 Resolved
Provide a current light list IAW 46 CFR 185.20-35.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 30 April 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 29 March 2007 Resolved
Provide tide/tidal current tables IAW 46 CFR 185.20-35.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 30 April 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 29 March 2007 Resolved
Provide current US Coast Pilot IAW 46 CFR 185.20-35.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 30 April 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 29 March 2007 Resolved
Provide USCG with a complete and satisfactory drug program IAW 46 CFR 16.
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 23 June 2009
Resolution: Satisfactory DAPI completed.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 12 May 2005 Resolved
Conduct DAPI audit.
Action required: 705 - Other - as specified
Due 12 June 2005
Resolved 18 May 2005
Documentation › Certificates/Documents › Stability Letter
Issued 12 May 2005 Resolved
Post Stability Letter on vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 May 2005
Resolved 18 May 2005
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 May 2005 Resolved
Provide current Coast Pilot and Light List.
Action required: 705 - Other - as specified
Due 12 June 2005
Resolved 7 April 2006
Lifesaving › Lifebuoys
Issued 27 June 2003 Resolved
Replace detachable line to waterlight IAW 46CFR180.70. LEGACY COMPONENT DESC: Detachable line for waterlight
Condition: Improper Installation
Due 27 June 2003
Resolved 27 June 2003
Resolution: Corrected on the spot.
Lifesaving › Visual Distress Signals (General)
Issued 27 June 2003 Resolved
Replace 3 expired hand flares IAW 46CFR180.68. LEGACY COMPONENT DESC: Signaling devices - hand flares
Due 4 July 2003
Resolved 7 July 2003
Communications › Radio Communications
Issued 27 June 2003 Resolved
Reregister EPIRB IAW46CFR185.728(c). LEGACY COMPONENT DESC: EPIRB
Due 10 July 2003
Resolved 7 July 2003
Documentation › Logs/Records
Issued 27 June 2003 Resolved
Provide a current training log IAW 46CFR185.20. LEGACY COMPONENT DESC: Logbook (official)
Condition: Unknown
Due 4 July 2003
Resolved 7 July 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 June 2003 Resolved
Replace expired eyewash IAW 46CFR184.710.
Condition: Improper/Lack of Maintenance
Due 27 June 2003
Resolved 27 June 2003
Resolution: Corrected on the spot.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 27 June 2003 Resolved
Service all portable fire extinguishers IAW 46CFR176.810.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 June 2003
Resolved 27 June 2003
Resolution: Corrected on the spot.
Construction/Loadline
Issued 21 May 2002 Resolved
Replace missing bulwark at the forward ladder. LEGACY COMPONENT DESC: Bulwark
Due 22 May 2002
Resolved 24 May 2002
Resolution: Vessel operator replaced the missing bulwark at the forward ladder.
Construction/Loadline
Issued 21 May 2002 Resolved
Replace missing bulwark and gate at the aft ladder. LEGACY COMPONENT DESC: Bulwark
Due 22 May 2002
Resolved 24 May 2002
Resolution: Vessel operator replace bulwark and gate at the aft ladder.
Construction/Loadline
Issued 21 May 2002 Resolved
Tighten up hand rails on the stbd side, amidships. LEGACY COMPONENT DESC: Hand Rails
Due 22 May 2002
Resolved 24 May 2002
Resolution: Vessel operator tightened all hand rails on vessel.
Construction/Loadline › Structures
Issued 21 May 2002 Resolved
Replace cracked window on the stbd side, main deck. LEGACY COMPONENT DESC: Bridge Window
Due 22 May 2002
Resolved 24 May 2002
Resolution: Vessel operator replaced the cracked window on the stbd side, main deck.
Engineering
Issued 21 May 2002 Resolved
Replace broken bilge hand pump in the MSD compartment. LEGACY COMPONENT DESC: Bilge Hand Pump
Due 22 May 2002
Resolved 24 May 2002
Resolution: Vessel operator replaced the broken bilge hand pump.
Deck/Cargo › Mooring/Anchoring
Issued 21 May 2002 Resolved
Provide sufficient quantity of anchor line for area of operation. LEGACY COMPONENT DESC: Anchor Line
Due 22 May 2002
Resolved 24 May 2002
Resolution: Vessel operator provided sufficient quantity of anchor line for area of operation.
Unknown
Issued 10 April 2001 Resolved
Provide proof of acceptance in the (Reliable) Employee Assistance and Drug Screening Consortium IAW 46 CFR Part 16.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Unknown
Issued 10 April 2001 Resolved
Replace unreadable and poorly located Oil Pollution Placard IAW 33 CFR 155.450.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Navigation
Issued 10 April 2001 Resolved
Provide current USCG Light List (excerpt) IAW 46 CFR 184.420.
Condition: Unknown
Due 16 April 2001
Resolved 16 April 2001
Engineering
Issued 14 June 1999 Resolved
Install emergency fuel oil cutoff valves for each fuel tank and indicate on-off direction.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Fire Fighting
Issued 14 June 1999 Resolved
Completed annual service inspection for (1) BI and (2) BII fire extinguishers.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Accommodation/Occupational Safety
Issued 14 June 1999 Resolved
Make installed MSD accessible and operational. Ensure system cannot be unintentionally discharged to sea.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Fire Fighting
Issued 14 June 1999 Resolved
Acquire (3) 2 1/2 gallon buckets, label and attach lanyard in accordance with 46 CFR 181.610.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Engineering
Issued 14 June 1999 Resolved
Install flame vent safety screens in accordance with 46 CFR 182.450(e) on both fuel tanks.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Electrical
Issued 7 May 1996 Resolved
Provide portable lights in accordance with 46 CFR 183.430.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Lifesaving
Issued 7 May 1996 Resolved
Conduct passenger safety orientation in accordance with 46 CFR 185.506.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Lifesaving
Issued 7 May 1996 Resolved
Post PFD placards in accordance with 46 CFR 185.516.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Lifesaving
Issued 7 May 1996 Resolved
Provide a suitable container for the distress signals in accordance with 46 CFR 185.614.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Documentation
Issued 7 May 1996 Resolved
Properly post stability letter, COI, and the emergency check off list.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Lifesaving
Issued 7 May 1996 Resolved
Renew the ring buoy or replace the periphery grab line.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Documentation
Issued 7 May 1996 Resolved
Renew the oil pollution placard.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Navigation
Issued 7 May 1996 Resolved
Prove operation of the compass light in accordance with 46 CFR 184.402.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Documentation
Issued 7 May 1996 Resolved
Post a radio emergency broadcast placard in accordance with 46 CFR 184.506.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Construction/Loadline
Issued 9 May 1995 Resolved
INSTALL MEANS OF ADEQUATELY VENTING THE VOIDS.
Condition: Unknown
Due 9 May 1995
Resolved 9 May 1995
Construction/Loadline
Issued 10 May 1993 Resolved
REPAIR PORT SIDE DOOR
Condition: Unknown
Due 11 June 1993
Resolved 11 June 1993
Accommodation/Occupational Safety
Issued 10 May 1993 Resolved
REPAIR SEAT AFT CENTERLINE
Condition: Unknown
Due 11 June 1993
Resolved 11 June 1993
Construction/Loadline
Issued 10 May 1993 Resolved
REPAIR LIFE LINES FORWARD STARBOARD SIDE
Condition: Unknown
Due 11 June 1993
Resolved 11 June 1993
Accommodation/Occupational Safety
Issued 10 May 1993 Resolved
REPAIR HAND RAIL BASE FORWARD STARBOARD
Condition: Unknown
Due 11 June 1993
Resolved 11 June 1993