MAURY USCG vessel records Sign in
← All vessels

ATLANTIC SPIRIT

ATLANTIC SPIRIT is a 1988 freight ship. The Coast Guard has recorded 19 inspections since 1993, most recently in January 2003, along with 21 deficiencies and 5 operational controls.

Records from 1993 to 2003. Most recent: inspection, 18 January 2003.

Built
1988
Last inspected
18 January 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8601800 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
348864
Flag
ROMANIA
—
Maury page id
psix-348864

Inspections, by type

…with no type recorded16
Years with a record 6 calendar years (1993–2003)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12215 - Regulatory (Subpart C or D), Gross Ton
6880 - Regulatory (Subpart C or D), Net Ton
15985 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

18 January 2003 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1735784
2 January 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1726833
26 December 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1723058
22 December 2002 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1722311
9 August 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 19004
21 July 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 280235
6 December 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 385626
23 October 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 702386
18 October 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 53985
18 October 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 472053
2 July 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 380037
16 March 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 699187
16 February 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 699188
12 February 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1396049
10 February 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 364354
11 February 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 356321
26 January 1993 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 460446
21 January 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 355777
11 January 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 355627

Deficiency record · 21

Navigation › Electronic Positioning
Issued 2 January 2003 Resolved
Vessel reported inoperable radar and ARPA. Inbound deviation granted. Vessel detained .Vessel must repair radar and ARPA pior to departure from the Port of Houston.
Due 2 January 2003
Resolved 6 January 2003
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 22 December 2002 Resolved
Inoperable reefer compartments due to compressor failure. New compressors are on board and are awaiting installation. LEGACY COMPONENT DESC: compressor
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 18 January 2003
Resolution: Recieved report from DNV stating deficiency has been cleared.
Engineering › Steering Gear System
Issued 22 December 2002 Resolved
Faulty circuit card resulted in loss of 24 vdc to steering alarm. LEGACY COMPONENT DESC: Solenoid Valve
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 18 January 2003
Resolution: Cleared
Accommodation/Occupational Safety › Washroom/Toilet
Issued 22 December 2002 Resolved
Toilets do not flush. LEGACY COMPONENT DESC: Toilet
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 December 2002
Accommodation/Occupational Safety › Washroom/Toilet
Issued 22 December 2002 Resolved
There is no running hot water on board vessel. LEGACY COMPONENT DESC: Hot and Cold Running Water
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 December 2002
Lifesaving › Launching Appliances
Issued 22 December 2002 Resolved
Inoperative recovery winch for port side lifeboat. LEGACY COMPONENT DESC: Winch
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 December 2002
Navigation › Collision/Grounding Avoidance
Issued 22 December 2002 Resolved
Radar display not functioning properly at different range settings. LEGACY COMPONENT DESC: Radar
Action required: 705 - Other - as specified
Due 29 December 2002
Resolved 2 January 2003
Resolution: Recieved technician report attesting to repairs and satisfactory operation of RADAR.
Navigation
Issued 2 July 1995 Resolved
VSL'S STEERING SPACE HAD OPEN TOP 55 GAL. DRUM FULL OF HYDRAULIC_x001C_ OIL. ALSO EXCESSIVE AMOUNT OF HYDRAULIC OIL ON DECK IN MOST OF SPACE._x001C_ BEFORE VSL DEPARTS ALL OIL TO BE WIPED AND ALL LEAKS DETECTED & REPAIRED_x001C_ IF POSSIBLE. DRUM OF OIL TO BE PROPERLY DISPOSED OF._x001C_
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Lifesaving
Issued 2 July 1995 Resolved
2 OF VSL'S STBD L/B PULLEYS NOT TURNING WHEN L/B LOWERED & RAISED. ALSO_x001C_ L/B INTERNAL RELEASE SYSTEM NOT WORKING PROPERLY. VSL TO PROVE PROPER LAUNCHING & RETRIEVING OF STBD L/B BEFORE DEPARTURE. SOLAS III/12
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Navigation
Issued 2 July 1995 Resolved
VSL HAD NO LARGE SCALE CHART FOR AREA TRANSITED. TO BE CORRECTED WITH_x001C_ NEW CHART ONBOARD BEFORE VSL DEPARTURE.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Lifesaving
Issued 2 July 1995 Resolved
NONE OF VSL'S LIFERING BUOYS HAVE RETROREFLECTIVE TAPE. ALL LIFERING _x001C_ BUOYS TO HAVE TAPE PRIOR TO DEPARTURE. SOLAS III/30.2.7_x001C_
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Navigation
Issued 2 July 1995 Resolved
VSL'S ARPA HAS NO LABEL. TO CORRECT PRIOR TO NEXT U.S. VOYAGE BUT_x001C_ NLT 02AUG95.
Condition: Unknown
Due 24 October 1995
Resolved 24 October 1995
Fire Fighting
Issued 2 July 1995 Resolved
DISCHARGE PIPING CONNECTED TO VSL'S SECONDARY FIRE PUMP IN E/R LEAKING_x001C_ UNDER PRESSURE. APPROX. 3" VERTICAL HAIRLINE CRACK OBSERVED. VSL TO MAKE TEMPORARY REPAIRS PRIOR TO DEPARTURE WITH PERMANENT REPAIRS MADE NLT 02AUG95. SOLAS II-2/21 03JUL: FIBERGLASS WRAP TEMP PATCH IN PLACE.
Condition: Unknown
Due 23 July 2000
Resolved 23 July 2000
Navigation
Issued 2 July 1995 Resolved
VSL HAS 1985 SUPPLEMENT FOR BA COAST PILOT VOLUME 69. NEEDS 95 SUPPLEMENT_x001C_CORRECT OR GET U.S. COAST PILOT VOLUME 4 BEFORE VSL DEPARTS.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Navigation
Issued 2 July 1995 Resolved
VSL TRANSITED UP THE CAPE FEAR RIVER (AN INLAND WATER) WITHOUT INLAND_x001C_ NAVIGATION RULES. TO CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 July 1995
Resolved 3 July 1995
Navigation
Issued 10 February 1994 Resolved
July 1993 edition of U.S. Light List showed no corrections nor updates._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 July 1995
Resolved 2 July 1995
Navigation
Issued 10 February 1994 Resolved
Vessel's 1992 edition of the U.S. Coast Pilot missing all Notice to Mariners updates and corrections.
Condition: Unknown
Due 17 February 1994
Resolved 3 March 1994
Navigation
Issued 10 February 1994 Resolved
Tidal Current tables not on board.
Condition: Unknown
Due 17 February 1994
Resolved 3 March 1994
Navigation
Issued 10 February 1994 Resolved
No block diagram on bridge. Vessel Engineers took approximately 30 minutesto operate steering gear in after steering._x001C_
Condition: Unknown
Due 17 February 1994
Resolved 3 March 1994
Accommodation/Occupational Safety
Issued 10 February 1994 Resolved
Trash in stern discharge bins not segregated. Trash stowed in plastic bags._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 February 1994
Resolved 3 March 1994
Engineering
Issued 10 February 1994 Resolved
Vessel did not have fuel transfer procedures aboard.
Condition: Unknown
Due 21 March 1994
Resolved 21 March 1994

Ownership record