MAURY USCG vessel records Sign in
← All vessels

RETRIEVER

RETRIEVER is a 1990 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1990, most recently in May 2026, along with 63 deficiencies.

Records from 1990 to 2026. Most recent: inspection, 21 May 2026.

Built
1990
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

348937
Flag
UNITED STATES
—
Maury page id
psix-348937

Inspections, by type

…with no type recorded1
Years with a record 33 calendar years (1990–2026)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)21.5 ft × 10.0 ft × 5.0 ft
Registered tonnagegross 7 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCROSBY YACHT YARD, INC. · OSTERVILLE, MA, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 27 October 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 50

21 May 2026 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8319856
30 April 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8319836
16 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8096674
30 April 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8096673
9 April 2025 Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8139205
20 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7913945
24 May 2023 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7651131
27 April 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7651128
25 May 2022 COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7431860
28 July 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7367280
29 April 2021 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7187843
18 August 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7035472
8 August 2019 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6776453
6 May 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6676228
16 August 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6512740
8 May 2017 Deficiency Check · COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6141335
17 August 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5975419
24 August 2015 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5225040
25 August 2014 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4965739
29 May 2012 COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4326768
1 December 2011 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4199145
11 May 2009 Hull Examination · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3472453
26 June 2008 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3248600
24 May 2007 Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2938838
27 May 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2369615
25 May 2005 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2367818
27 May 2003 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1818738
7 June 2002 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1627726
18 May 2001 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1415642
6 June 2000 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1403168
28 May 1999 Deficiency Check · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1188757
3 May 1999 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126210
8 July 1998 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 794640
3 June 1997 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 778849
19 May 1997 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1094731
12 May 1997 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1102693
21 May 1996 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 864754
13 June 1995 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1187425
31 May 1995 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 875133
1 June 1994 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1174119
24 May 1994 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1170307
21 May 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1147262
23 April 1993 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 833185
2 June 1992 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1254734
24 September 1991 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1002520
2 August 1991 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 935787
22 May 1991 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 938662
13 May 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 917787
24 April 1990 Initial Construction-Excluding Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 926396
24 April 1990 Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1244201

Deficiency record · 63

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2026 Resolved
Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Battery inside waterlight was expired. Replace with new type approved battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 4 June 2026
Resolution: Operator provided pictures of newly purchased battery of correct type.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2026 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). Ring buoy was missing retroreflective material on one of the quadrants. Apply new retroreflective material to missing section.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 4 June 2026
Resolution: Operator provided pictures of newly applied retro tape on lifebuoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 May 2026 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 2.5 gallon buckets. Fire buckets were 5 gallon buckets. Replace with 2.5 gallon buckets or drill holes halfway up the side of existing bucket so that it cannot be filled past 2.5 gallons.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2026
Resolved 4 June 2026
Resolution: Operator provided pictures of holes drilled into existing fire buckets.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 16 May 2025 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel carried two different types of type 1 PFD's and only had instructions for one type on board. O/O to equip vessel with donning instructions for both types of PFD's carried on board to satisfaction of attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 29 May 2025
Resolution: O/O installed life jacket donning instructions to satisfaction of attending marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 May 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's all around white light was missing a bulb and not shining in front half of vessel. O/O to repair/replace light to satisfaction of attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 9 June 2025
Resolution: Received objective evidence of light fully fuctioning.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 16 May 2025 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The medical certificate will be issued for various periods of time based upon the endorsements the mariner holds. Master of vessel had an expired medical certificate at time of inspection. O/O to have master renew medical certificate. 46CFR10.301
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 9 June 2025
Resolution: O/O will have alternate operators use launch.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 May 2025 Resolved
THE EMPLOYER SHALL PROVIDE AN EMPLOYEE ASSISTANCE PROGRAM (EAP) FOR ALL CREWMEMBERS. OPERATOR COULD NOT PROVIDE EVIDENCE OF HAVING AN ESTABLISHED EAP. PROVIDE EVIDENCE THAT WOULD SHOW THAT THE COMPANY HAS AN EAP, OR CREATED AN EAP TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46CFR16.401(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2025
Resolved 29 May 2025
Resolution: O/O posted EAP hot line number and updated EAP program for yacht club to satisfaction of attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2025 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. Vessel's shaft cutlass bearing was near the end of allowable service life. Instead of requiring replacement this year, CID allowed the deficiency to repaired at the end of season within one year. O/O to repair/replace to satisfaction of attending marine inspector within one year if issuance. 46CFR182.05-1(a) Old T
Action required: 705 - Other - as specified
Due 30 April 2026
Resolved 30 April 2026
Resolution: Cutlass bearing was replaced during dry dock. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 20 May 2024 Resolved
Suitable overs, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Railing on the PORT side embarkation was broken in two spots and needs to be repaired. 46 CFR 17735-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2024
Resolved 19 June 2024
Resolution: MI received objective evidence photographs showing the fixed welds of the stanchion's sockets and the proper installation of the safety rails.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 July 2021 Resolved
Battery connections must be made to battery terminals with permanent type connectors. Connectors are currently twist on nuts and must be replace with permanent connectors.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2021
Resolved 29 July 2021
Resolution: Confirmed the replacing of the battery terminals.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 July 2021 Resolved
Vessel must carry one floating waterlight. Vessel's waterlight is inoperable and shall be replaced. Clear def prior to operating at night.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2021
Resolved 29 July 2021
Resolution: Confirmed the replacement of the waterlight.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 28 July 2021 Resolved
Vessel shall have two operable portable battery lights. Vessel lacks all portable battery lights. Ensure the installation of the two lights onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 August 2021
Resolved 29 July 2021
Resolution: Confirmed that two portable lights are now onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 August 2020 Resolved
A vessel must have one or more ring life buoys as follows: A vessel of not more than 7.9 meters (26 feet) in length must carry a minimum of one life buoy of not less than 510 millimeters (20 inches) in diameter. Life ring buoy was present but not in serviceable condition. Grab lines were deteriorated. Replace life ring bouy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 19 August 2020
Resolution: Vessel provided photograph of new ring life buoy to replace the previous one onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 August 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; (2) U.S. Coast Pilot or similar publication; (3) Coast Guard Light List; (4) Tide tables; and (5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Charts of large enough scale to make safe navigation possible. No charts or pubs available.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2020
Resolved 1 September 2020
Resolution: Vessel acquired new up-to-date charts and publications applicable to the vessel's route.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 18 August 2020 Resolved
Abandon ship fire and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and (2) General description of the drill scenario and training. No drills logged. Logged after inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 August 2020
Resolved 18 August 2020
Resolution: Vessel logged MOB drill and Fire drill conducted during the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 August 2018 Resolved
A vessel must carry 01 floating waterlight attached to a ring buoy by lanyard. Provide approved waterlight with lanyard and corrosion resistant clip to attach light to ring buoy. Vessel limited to daylight operations only.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 16 August 2018
Resolution: Vessel owner purchased and installed new waterlight.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 August 2018 Resolved
Portable and fixed fire extinguishers must be inspected. Provide proof of inspection for all firefighting extinguishers. Provide proof of inspection to Marine Inspector within 7 days
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 August 2018
Resolved 23 August 2018
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 June 2017 Resolved
Provide emergency instructions.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 June 2017
Resolution: Provided emergency instructions.
Personnel › Training › Fire Fighting Basic
Issued 1 June 2017 Resolved
Conduct required crew training for man overboard and fire. Provide log to satisfaction of marine inspector.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 June 2017
Resolution: Provided log of required training.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 1 June 2017 Resolved
Provide name of vessel on port and stbd bow.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 15 June 2017
Resolution: Provided proper vessel marking.
Stability › Weathertight Integrity › General
Issued 1 June 2017 Resolved
Re-seal engine compartment hatch, make weathertight.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 29 June 2017
Resolution: Completed repair on engine compartment hatch.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear, Timing
Issued 8 May 2017 Resolved
Prove proper operation of new engine installation.
Action required: 705 - Other - as specified
Resolved 1 June 2017
Resolution: Conducted underway sea trial of Engine Installation; all satisfactory.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 August 2016 Resolved
Vessel rep could not produce valid COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2016
Resolution: Received proof of current COD.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 August 2016 Resolved
Vessel did not have available written emergency instructions.
Action required: 705 - Other - as specified
Resolved 17 August 2016
Resolution: Operator produced emergency instructions; corrected on-site.
Documentation › Markings/Placards › Lifejacket Placard
Issued 17 August 2016 Resolved
No PFD donning placard in place.
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 2 September 2016
Resolution: Received photo of mounting PFD donning placard.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 August 2016 Resolved
Failure to provide proof of enrollement in DAP for one operator.
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 2 September 2016
Resolution: Operator enrolled in company DAP and new updated list received.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 17 August 2016 Resolved
Failure to produce current/valid MMC for one operator. Provide prior to operating.
Action required: 705 - Other - as specified
Resolved 2 September 2016
Resolution: Received proof of valid MMC for referenced operator.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 17 August 2016 Resolved
No Vessel name on Port/STBD bow.
Action required: 705 - Other - as specified
Due 31 August 2016
Resolved 2 September 2016
Resolution: Received photo of Vessel name affixed.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 August 2015 Resolved
Fire extinguishers servicing tags missing; provide servicing tags or certificates.
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 8 September 2015
Resolution: Vsl rep provided servicing tags for fire extinguishers.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 24 August 2015 Resolved
Lable lifejacket stowage with correct number.
Action required: 705 - Other - as specified
Due 7 September 2015
Resolved 22 September 2015
Resolution: Life jacket stowage is labeled with the correct number.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 August 2014 Resolved
When testing the fire boy engine shutdown, an audible alarm sounded, but the fire boy engine shutdown was inoperable. Service and/or repair fire boy engine shutdown by specified date. 46 CFR 181.20-5(a)
Action required: 705 - Other - as specified
Due 8 September 2014
Resolved 9 September 2014
Resolution: Verified the engine shutdown of the pre-engineered fixed fire extinguishing system.
Engineering › Steering Gear System › Rudder
Issued 25 August 2014 Resolved
There was leaking from the rudder packing. Repair/replace rudder packing. 46 CFR 182.30-1
Action required: 705 - Other - as specified
Due 8 September 2014
Resolved 9 September 2014
Resolution: Verified that the rubber packing was tightened.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 August 2014 Resolved
There was no retro reflective tape on the ring buoy. Add retro reflective tape.
Action required: 705 - Other - as specified
Due 8 September 2014
Resolved 9 September 2014
Resolution: Verified that the RLB had reflective tape.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 August 2014 Resolved
Mounting bracket for forward fire extinguisher is not secured to the vessel. Repair mounting bracket. 46 CFR 181.20-30
Action required: 705 - Other - as specified
Due 8 September 2014
Resolved 9 September 2014
Resolution: New mounting bracket was installed.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 29 May 2012 Resolved
Vessels fire boy does not shut down engine. Vessel will carry a Additional BII until fire boy repaired
Condition: Improper Installation
Due 12 June 2012
Resolved 12 June 2012
Resolution: Fireboy tech rep and vessel rep found broken wire on back of elec. panel wire was replaced fireboy tested sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 29 May 2012 Resolved
Ventilation tubes to the engine compartment are wasted in the fwd compartment, both port and stbd horizontal section need replacement.
Condition: Improper/Lack of Maintenance
Due 12 June 2012
Resolved 12 June 2012
Resolution: Rotted ventilation tubes in fwd compartment were replaced.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 29 May 2012 Resolved
Vessels high water alarm is not working properly
Condition: Damaged By Earlier Event
Due 12 June 2012
Resolved 12 June 2012
Resolution: Vessel rep repaired broken bilge alarm wire.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 24 May 2007 Resolved
Pre-engineered system alarm and automatic engine shut down inoperable/annual service overdue.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2007
Resolved 5 June 2007
Resolution: Corrected
Engineering › Bilge Water Management System › Pump
Issued 24 May 2007 Resolved
Portable bilge pump missing, provide same.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2007
Resolved 29 May 2007
Resolution: Corrected
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2007 Resolved
First aid kit contents expired and missing/provide new.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 May 2007
Resolved 29 May 2007
Resolution: Corrected
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 May 2007 Resolved
Missing hose clamps on shaft seal cooling line/provide clamp.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 29 May 2007
Resolution: Corrected
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 May 2007 Resolved
Provide COD.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 29 May 2007
Resolution: Corrected
Documentation › Logs/Records › Logbook (official)
Issued 24 May 2007 Resolved
Provide logbook
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 29 May 2007
Resolution: Corrected
Engineering › Steering Gear System › Rudder
Issued 24 May 2007 Resolved
Rudder packing leaking. Tighten same.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 5 June 2007
Resolution: Corrected
Documentation › Markings/Placards › Lifejacket Placard
Issued 27 May 2005 Resolved
Post the following safety placards: emergency instructions, life preserver donning instructions, and may day radio placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 September 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 May 2005 Resolved
Provide launch with a first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 September 2005
Engineering › Fuel Oil Service System › Valve
Issued 27 May 2005 Resolved
Label fuel oil supply shut off valve.
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 September 2005
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 27 May 2005 Resolved
Fax a copy of the launch's drug testing enrollment to the Sector Boston [phone withheld].
Action required: 705 - Other - as specified
Due 10 June 2005
Resolved 2 September 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 May 2005 Resolved
Prior to carrying passengers, make vessel available for annual exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2005
Resolved 27 May 2005
Engineering › Steering Gear System
Issued 27 May 2003 Resolved
Prove rudder/tiller linkage will fail safe. Existing arrangement appears susceptible to failure under daily maneuvering vibration. LEGACY COMPONENT DESC: Linkage
Due 31 July 2003
Resolved 5 June 2003
Resolution: Received fax from YC with a statement from the manufacturer attesting to the suitability of the linkage arrangement.
Documentation
Issued 6 June 2000 Resolved
Prove compliance with an approved Drug testing program. To be completed to the satisfaction of the attending marine inspector, but not later than 26JUN00.
Condition: Unknown
Due 26 June 2000
Resolved 27 July 2000
Construction/Loadline
Issued 28 May 1999 Resolved
PROVIDE MANUAL BILGE PUMP FOR VESSEL
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Lifesaving
Issued 28 May 1999 Resolved
PROVIDE COAST GUARD APPROVED FIRST AID KIT.
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Fire Fighting
Issued 28 May 1999 Resolved
PROVIDE ENGINE SHUT DOWN DEVICE ASSOCAIATED WITH THE FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Navigation
Issued 28 May 1999 Resolved
ADJUST (TIGHTEN) RUDDER POST PACKING.
Condition: Unknown
Due 17 June 1999
Resolved 17 June 1999
Lifesaving
Issued 19 May 1997 Resolved
ADULT/CHILD PFDs NOT STORED IN SEPARATE CONTAINERS AND NOT CLEARLY MARKED.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Documentation
Issued 19 May 1997 Resolved
PROVIDE PROOF OF COMPLIANCE WITH FEDERAL DRUG TESTING REGULATIONS AS SPECIFIED IN 46 CFR PART 16.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Lifesaving
Issued 19 May 1997 Resolved
RING BUOY NOT FITTED WITH RETRO-REFLECTIVE TAPE PER 46 CFR 185.604(h).
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Lifesaving
Issued 21 May 1996 Resolved
REPLACED RING BUOY WORN BY WEATHER THIS EXAM.
Condition: Unknown
Due 21 May 1996
Resolved 5 June 1996
Construction/Loadline
Issued 31 May 1995 Resolved
GRIND OUT AND REGLASS FRACTURED FRP IN WAY OF SHAFT TUBE HULL PENATRATION. REPAIR IS TO BE COMPLETED TO THE SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR ON OR BEFORE VESSEL'S SECOND REINSPECTION OR 16JUN95.
Condition: Unknown
Due 31 May 1995
Resolved 31 May 1995
Documentation
Issued 21 May 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 June 1993
Resolved 11 June 1993
Lifesaving
Issued 21 May 1993 Resolved
PRIOR TO CARRYING PASSENGERS THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS.
Condition: Unknown
Due 10 June 1993
Resolved 11 June 1993
Lifesaving
Issued 21 May 1993 Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION, AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED VESSEL CREWMEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 10 June 1993
Resolved 11 June 1993

Ownership record