Records from 2016 to 2026. Most recent: inspection, 28 April 2026.
Inspection history · 17
28 April 2026
In-Service Inspection · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8357734
25 March 2026
Administrative Inspection
Administrative · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8331840
14 August 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8209967
10 June 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 8158830
25 June 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7942619
27 April 2023
Administrative Inspection · Internal Structural Exam · Examination of Repairs · COI Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7677062
6 July 2022
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7499150
24 June 2021
Administrative Inspection · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7205718
18 May 2021
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 7200209
29 May 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6963792
16 May 2019
Internal Structural Exam · Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6678016
14 May 2018
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6409027
2 March 2018
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6364960
14 November 2017
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6307012
20 April 2017
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6174786
25 October 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6029694
14 April 2016
COI Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5860578
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 14 August 2025
Resolved
Ensure IBA's are serviced and installed properly prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2026
Resolution: Newly installed IBAs.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 August 2025
Resolved
Ensure crew is enrolled in a CG approve drug testing program including alcohol swabs
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2026
Resolution: Verified enrollement into Consortium.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 14 August 2025
Resolved
Provide 03 day flares
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2025
Resolved 20 August 2025
Resolution: required flares onboard
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 August 2025
Resolved
Update first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2025
Resolved 20 August 2025
Resolution: first aid kit updated
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 14 August 2025
Resolved
Ensure stbd running light is operational
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 September 2025
Resolved 20 August 2025
Resolution: operational
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 14 August 2025
Resolved
Renew EPIRB battery and EPIRB hydro.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2026
Resolution: Verified presence of Registered EPIRB.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 August 2025
Resolved
Ensure emergency fuel shutoff is operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2025
Resolution: renewed and operational
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 May 2023
Resolved
Conduct satisfactory vapor detection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2023
Resolved 17 May 2023
Resolution: test sat
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2023
Resolved
Ensure there is a 2A fire extinguisher for the accommodation space. Currently there is a 1A fire extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2023
Resolved 17 May 2023
Resolution: fire extinguisher installed
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 11 May 2023
Resolved
Ensure all crew in a safety sensitive position are enrolled in a DOT approved drug testing program. Show proof of enrollment prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2023
Resolution: enrolled
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2023
Resolved
Ensure portable light at the operating station is operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2023
Resolved 17 May 2023
Resolution: operational
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 July 2022
Resolved
Ensure pre-engineered system has a manual activation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2022
Resolved 19 July 2022
Resolution: Witnessed connection of manual discharge handle for pre-engineered fire suppression system
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 July 2022
Resolved
Ensure fire buckets have appropriate lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2022
Resolved 19 July 2022
Resolution: Verified lanyards on fire buckets
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 July 2022
Resolved
High water alarm should have audible and visual alarms. Laz alarm, visual was not operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 19 July 2022
Resolution: Witnessed satisfactory test of audible and visual alarms
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 July 2022
Resolved
Provide lights for auto bilge pumps to show operating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 21 July 2022
Resolution: Witnessed light for automatic operation of bilge pumps.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 6 July 2022
Resolved
Post EAP phone number.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 August 2022
Resolved 19 July 2022
Resolution: Verified number posted
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 June 2021
Resolved
Vessel EPIRB is to be equipped with an in service battery. The EPIRB battery was found to be expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 8 July 2021
Resolution: replaced
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 24 June 2021
Resolved
Vessel EPIRB is to be equipped with an in-service hydrostatic release unit. The EPIRB hydrostatic release unit was found to be expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 July 2021
Resolved 8 July 2021
Resolution: replaced
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 June 2020
Resolved
Conduct emergency drills prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2021
Resolution: cleared
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 June 2020
Resolved
Provide current NOAA registration for EPIRB
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 18 May 2021
Resolution: corrected
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 18 June 2020
Resolved
Re-label storage space for portable fire extinguisher on back deck
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 18 May 2021
Resolution: corrected
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 June 2020
Resolved
Replace expired aspirin in first aid kit
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 18 May 2021
Resolution: corrected
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2020
Resolved
Replace expired alcohol test strips
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 18 May 2021
Resolution: corrected
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 May 2018
Resolved
Lifejackets need to be stenciled with name of vessel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2018
Resolved 11 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 14 May 2018
Resolved
Vessel's lifebuoy was worn and wasted.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 May 2018
Resolved 14 May 2018
Resolution: Managing Owner went to Eagle Enterprise-local boating store and purchased a new lifebuoy, light, and line. Stenciled prior to MI departure.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 14 May 2018
Resolved
Vessel does not have FCC Station license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: Vessel provided FCC license.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 May 2018
Resolved
Vessel did not have current publications, tide tables, etc.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2018
Resolved 11 June 2018
Resolution: Vessel purchased new pubs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 May 2018
Resolved
Vessel had multiple dead end wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2018
Resolved 11 June 2018
Resolution: Vessel removed dead wires from under steering console.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2018
Resolved
Vessels high level bilge alarm in fuel tank space was not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2018
Resolved 11 June 2018
Resolution: Vessel replaced high level alarm for bilge.
Operations/Management › Vessel Activity › Other
Issued 20 April 2017
Resolved
Complete a drydock and internal structural exam prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2017
Resolution: Completed satisfactory drydock exam
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 July 2016
Resolved
Prove proper operation of Aft bilge high level sensor alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2016
Resolved 11 June 2018
Resolution: Vessel replaced high level bilge alarm in fuel tank space.