SUNDANCE

SUNDANCE is a 1990 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 1990, most recently in July 2020, along with 114 deficiencies — 5 with no resolution recorded —, 1 operational control and 1 casualty investigation in 2013.

Records from 1990 to 2020. Most recent: inspection, 7 July 2020.

Built
1990
Last inspected
7 July 2020
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG 2298
349325
Flag
UNITED STATES
367514210 (licence lapsed)
Maury page id
psix-349325

Inspections, by type

…with no type recorded5
Years with a record 24 calendar years (1990–2020)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)53.9 ft × 17.7 ft × 5.9 ft
Registered tonnagegross 15 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBELLECRAFT INDUST CORP · NAPLES, FL, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeSail (Distinct Keel)
Hull configurationTwin Hull
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it15 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG2298MMSI 367514210 · expired · compulsorily equipped · granted 31 December 2011, cancelled 5 March 2022
WCO7455MMSI not assigned · expired · voluntarily equipped · granted 14 November 1994, cancelled 15 January 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 47

7 July 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6999738
10 February 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6906325
16 May 2019 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6685857
14 February 2019 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6631877
11 May 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6411771
21 November 2017 Examination of Repairs · Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339620
4 May 2017 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6139148
14 February 2017 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6087968
3 May 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5867874
27 November 2015 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5770894
15 August 2014 Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4955883
13 May 2014 Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 4866138
9 May 2014 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4854568
5 July 2012 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4366208
27 January 2012 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4233323
22 March 2010 Drydock Exam · Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3700490
6 February 2009 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3402647
4 March 2008 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3416606
8 October 2007 Initial Certification · Deadweight Survey · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3092149
21 June 2004 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2106161
19 June 2002 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1633375
14 September 2001 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1071849
10 August 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1071100
26 April 2000 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1379043
6 March 2000 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1420271
28 October 1998 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1433425
5 November 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784220
30 March 1995 Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1424075
25 March 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 114318
7 March 1995 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1382915
18 March 1994 Deficiency Check · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1373999
22 February 1994 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 854484
28 January 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 853312
20 December 1993 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1160553
1 December 1993 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 848717
16 April 1993 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1412504
3 February 1993 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1445973
14 April 1992 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1267915
30 March 1992 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1359383
15 April 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 909874
2 April 1991 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1233625
25 September 1990 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214804
20 September 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1231691
4 September 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1238283
18 July 1990 Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1232546
13 July 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214763
5 July 1990 Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 930688

Deficiency record · 114

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2020 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is required to carry 51 life jackets but only had 50 on board. Provide the proper number of life jackets. 46CFR180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 4 March 2020
Resolution: An additional life jacket was procured and put onboard
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 10 February 2020 Resolved
The required IBA was not on board. Obtain IBA and install on board. Provide certificates to USCG upon installation. 46CFR180.200
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 March 2020
Resolved 31 March 2020
Resolution: Received life raft certificate and servicing record
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 10 February 2020 Resolved
The required first aid kit is not Coast Guard approved under 46CFR160.041. Provide a CG approved first aid kit or provide proof that the kit contains the items listed in 46CFR160.041-4 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2020
Resolved 2 March 2020
Resolution: An additional kit was provided and all items meet requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 February 2020 Resolved
Life jacket stowage does not accurately reflect the number of PFD's stowed in each location. The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Properly label life jacket stowage areas with the ammount stowed in each location. 46CFR185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2020
Resolved 4 March 2020
Resolution: Labeling of life jacket stowage areas has been updated, reflecting the proper number for each location.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 February 2020 Resolved
The reflective tape on the life ring is worn out and is no longer serviceable. Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Replace tape on life ring. 46CFR185.604(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2020
Resolved 2 March 2020
Resolution: New reflective tape was installed in lifering.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 February 2020 Resolved
The fire station does not have a spanner wrench. Spanner wrenches must be provided where a 40 millimeter (1.5 inch) diameter fire hose is required by §181.320(b). Provide a spanner wrench to be with the hose and nozzle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2020
Resolved 2 March 2020
Resolution: Spanner wrench provided at fire station.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 February 2020 No resolution recorded
Prior to operating under the new operator, provide training logs/records. The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by §185.510 of this part and, when applicable, the duties listed in the station bill required by §185.514 of this part.
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 10 February 2020 No resolution recorded
Prior to operating under the new operator,provide proof the the personnel are enrolled in a Chemical testing program. Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40.
Action required: 17 - Rectify deficiencies prior to departure
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 10 February 2020 No resolution recorded
Prior to operating under the new operator, demonstrate to the satisfaction of the attending marine inspector an abandon ship and man overboard drill.
Action required: 17 - Rectify deficiencies prior to departure
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 10 February 2020 No resolution recorded
Prior to operating under the new operator, demonstrate to the satisfaction of the attending marine inspector a fire drill.
Action required: 17 - Rectify deficiencies prior to departure
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2020 No resolution recorded
Movement of the vessel in Puget Sound without passengers while the existing no sail deficiencies are still outstanding is authorized for the purposes of relocating the vessel to its berth or for any needed maintenance. Prior to passenger service the above deficiencies must be cleared.
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 16 May 2019 Resolved
Provide new Certificate of Documentation or proof of re-ordering. Current certificate is expired. 46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2019
Resolved 17 May 2019
Resolution: Recieved email from owner of receipt of new COD ordered.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 16 May 2019 Resolved
Provide repair proposal for 2 hull penetrations on port side side shell in #2 and #4 voids. There are 2 pipes in the #2 and #4 void penetrating through side shell that you can see light to the outside. 46 CFR 176.20-1
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2019
Resolved 14 August 2019
Resolution: Observed satisfactory repair work of side shells.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 May 2019 Resolved
Safety Radio Certificate is expired. Provide updated Safety Radio Certificate. Vessel is restricted to 1000 ft from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 22 July 2019
Resolution: Received certificate.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 May 2019 Resolved
A vessel with a pre-engineered fixed gas fire extinguishing system must install a means to reset devices to automatically shut down ventilation systems and engines. Vessel over ride system was inoperable. 46 CFR 181.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 14 August 2019
Resolution: Observed satisfactory test of the vessel pre-engineered fire extinguishing system.
Fire Fighting › Fire Hoses › Condition
Issued 11 May 2018 Resolved
firehose shall be UL 19 approved and free of leaks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 25 May 2018
Resolution: vessel provided approved fire hose
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 11 May 2018 Resolved
repair high water level installation in starboard stern void.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 25 May 2018
Resolution: vessel proved proper operation of high level alarm
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 11 May 2018 Resolved
repair insulation on starboard side engine hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 25 May 2018
Resolution: vessel repaired insulation
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 11 May 2018 Resolved
install cover for exposed bus bar in battery compartment on the port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 25 May 2018
Resolution: vessel installed bus bar cover
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 11 May 2018 Resolved
reattach hatch cover on stern, port side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 25 May 2018
Resolution: vessel reattached cover on stern hatch, port side
Navigation › Piloting/Steering › Marine Charts
Issued 11 May 2018 Resolved
provide updated charts
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2018
Resolved 25 May 2018
Resolution: vessel provided updated charts
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 4 May 2017 Resolved
Provide unexpired alcohol testing strips.
Due 19 May 2017
Resolved 5 May 2017
Resolution: Received photo documentation of unexpired testing strips.
Electrical › Electrical Distribution System (emergency) › Junction Box
Issued 4 May 2017 Resolved
Make all high water alarm wires enclosed in junction boxes.
Due 31 May 2017
Resolved 11 May 2017
Resolution: Received photo documentation showing new junction boxes for high water alarm wires.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2016 Resolved
Vessel is to have onbaord a USCG approved first aid kit with required contents. Vessel does not have approved first aid kit or required contents. 46 CFR 184.710
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 18 May 2016
Resolution: Vessel bought a new USCG approved first aid kit.
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2016 Resolved
Vessel is to have onboard current and corrected charts for intended area of operation. Vessel's charts have not been updated since 2014.
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 18 May 2016
Resolution: Vessel bought new charts.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 May 2014 Resolved
Vessel shall not carry passengers in transit to New York or carry passengers in New Yorkuntil inspected and new COI issued by OCMI in New York.
Action required: 705 - Other - as specified
Resolved 18 August 2014
Resolution: Sector NY confirmed vessel is in process of receiving COI
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 27 January 2012 Resolved
Provide servicing certificate for fire extinguishing systems in accordance with 46 CFR 176.810.
Due 27 February 2012
Resolved 3 February 2012
Resolution: Certificate provided.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 January 2012 Resolved
Provide tide/tidal current information for all areas of operation in accordance with 46 CFR 184.420(a)(4).
Due 27 February 2012
Resolved 3 February 2012
Resolution: Acceptable booklets provided.
Navigation › Piloting/Steering › Magnetic Compass
Issued 27 January 2012 Resolved
Provide readable magnetic compass deviation table in accordance with 46 CFR 183.302(a).
Due 27 February 2012
Resolved 3 February 2012
Resolution: Table recopied.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 27 January 2012 Resolved
Provide ten child-sized lifejackets in accordance with 46 CFR 180.71(b) (9 on board at present).
Due 27 February 2012
Resolved 3 February 2012
Resolution: Required number of lifejackets present.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 January 2012 Resolved
Mark child-sized lifejacket stowage in accordance with 46 CFR 180.78(a)(5).
Due 27 February 2012
Resolved 3 February 2012
Resolution: Stowage properly marked.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 27 January 2012 Resolved
Replace unsuitable hose run in starboard seawater suction line in accordance with 46 CFR 182.100.
Due 27 February 2012
Resolved 3 February 2012
Resolution: Hose replaced.
Engineering › Fuel Oil Service System › Filter
Issued 27 January 2012 Resolved
Provide flame impingement bulb on fuel filter for generator in accordance with 46 CFR 182.20-40.
Due 27 February 2012
Resolved 3 February 2012
Resolution: Fuel filter replaced. New filter acceptable.
Electrical › Electrical Distribution System (emergency) › Cable
Issued 27 January 2012 Resolved
Propose solution to issue of bilge pump being powered by plug exposed to elements in accordance with 46 CFR 183.01-10(a).
Due 27 February 2012
Resolved 3 February 2012
Resolution: Proposed solution accepted and is being implemented.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 27 January 2012 Resolved
Vent blackwater tank to exterior of vessel in accordance with 46 CFR 176.830(a).
Due 27 February 2012
Resolved 3 February 2012
Resolution: Vent extended to exterior.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 27 January 2012 Resolved
Repair or replace start solenoid in accordance with 46 CFR 182.100.
Due 27 February 2012
Resolved 3 February 2012
Resolution: Starter replaced.
Stability › Watertight Integrity › General
Issued 27 January 2012 Resolved
Fill hole in watertight bulkhead in blackwater tank void in accordance with 46 CFR 176.830(a).
Due 27 February 2012
Resolved 3 February 2012
Resolution: Hole filled.
Documentation › Markings/Placards › Capacity Marking
Issued 27 January 2012 Resolved
Second deck capacity not properly marked in accordance with stability letter. Reads: 47 persons. Should read: 45 passengers.
Due 27 February 2012
Resolved 3 February 2012
Resolution: Marked for 45.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 February 2009 Resolved
Conduct drills in the presence of Marine Inspector prior to carrying passengers in accordance with 46CFR176.500.
Action required: 705 - Other - as specified
Due 9 February 2009
Resolved 9 February 2009
Resolution: Drills were conducted to the satisfaction of on scene marine inspector.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 6 February 2009 Resolved
Procure and maintain a training log in accordance with 46CFR185.420.
Action required: 705 - Other - as specified
Due 9 February 2009
Resolved 9 February 2009
Resolution: Vessel procured a satisfactory training log.
Documentation › Logs/Records › Logbook (official)
Issued 6 February 2009 Resolved
Procure a satisfactory bridge log in accordance with 46CFR185.520.
Action required: 705 - Other - as specified
Due 9 February 2009
Resolved 9 February 2009
Resolution: Vessel procured a satisfactory bridge log.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 February 2009 Resolved
Produce a corrosion resistant clip for lifebuoy in accordance with 46CFR180.70.
Action required: 705 - Other - as specified
Due 9 February 2009
Resolved 9 February 2009
Resolution: Vessel installed a satisfactory clip on ring buoy.
Stability › Weathertight Integrity › General
Issued 6 February 2009 Resolved
Replace seal on fwd weather tight door on main passenger deck in accordance with 46CFR175.400.
Action required: 705 - Other - as specified
Due 9 February 2009
Resolved 9 February 2009
Resolution: Vessel repairs to weather tight door appear satisfactory.
Operations/Management › Passenger Operations › Safety Orientation
Issued 6 February 2009 Resolved
Provide satisfactory method for passenger orientation in accordance with 46CFR185.506.
Action required: 705 - Other - as specified
Due 9 February 2009
Resolved 9 February 2009
Resolution: Vessel provided satisfactory means of conducting passenger orientation.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 February 2009 Resolved
Procure satisfactory first aid kit in accordance with 46CFR184.710.
Action required: 705 - Other - as specified
Due 9 February 2009
Resolved 9 February 2009
Resolution: Vessel acquired satisfactory first aid kit.
Operations/Management › Passenger Operations › Safety Orientation
Issued 6 February 2009 Resolved
Post information placards in required areas in accordance with 46CRF185.516 and 46CFR184.506.
Action required: 705 - Other - as specified
Due 9 February 2009
Resolved 9 February 2009
Resolution: Appropriate placards were posted to the satisfaction of on scene marine inspector.
Engineering › Bilge Water Management System › Piping
Issued 8 October 2007 Resolved
Install check valve in #6 port void bilge suction piping and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2007
Lifesaving › Lifefloat › Approval
Issued 8 October 2007 Resolved
Provide sufficient USCG approved life floats for 50% of passengers, for Lakes Bays & Sounds route. Install and arrange per 180.137 (stacking allowed, but weak link must be of sufficient strength to hold combined capacity of all LF's.) In accordance with 180.175(d), each LF must be equipped with it's own water light. (As found painter not rigged properly for clear unobstructed payout.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2007
Resolution: Owner removed 3 BA''''s and replaced with one 50 man USCG approved IBA.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 8 October 2007 Resolved
Secure exhaust leak from cylinder head, port MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 October 2007 Resolved
Label remote fuel shutoffs, and direction to close.
Due 8 November 2007
Resolved 26 October 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 October 2007 Resolved
Adjust & prove proper operation of port remote F/O shutoff.
Due 8 November 2007
Resolved 26 October 2007
Fire Fighting › Fire Pumps › Pressure
Issued 8 October 2007 Resolved
Prove proper operation of fire pump (50GPM/60PSI).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2007
Operations/Management › Passenger Operations › Safety Orientation
Issued 8 October 2007 Resolved
Enforce "Crew Only" on aft weather deck and upper deck, or add 4" coursings to existing rails.
Due 8 November 2007
Resolved 26 October 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 October 2007 Resolved
Add 1st aid kit approved under USCG 160.041.
Due 8 November 2007
Resolved 26 October 2007
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 8 October 2007 Resolved
Provide all navigation publications per 184.420.
Due 8 November 2007
Resolved 26 October 2007
Operations/Management › Drills/Instruction › Safety Orientation
Issued 8 October 2007 Resolved
Post lifejacket donning placards, emergency instruction checklist, and emergency broadcast placard.
Due 8 November 2007
Resolved 26 October 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 8 October 2007 Resolved
Arrange 3rd party FCC inspection for issuance of radiotelephony certificate.
Due 8 October 2007
Resolved 26 October 2007
Stability › Watertight Integrity › General
Issued 8 October 2007 Resolved
Add keeper cable to all weather deck scuttles and W/T hatches that are not hinged.
Due 8 November 2007
Resolved 26 October 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 October 2007 Resolved
Conduct fire, abandon ship and man overboard drills in presence of marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2009
Resolution: Drills were performed to the satisfaction of the on scene marine inspector.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 8 October 2007 Resolved
Prove vessel and crew capable of man overboard recovery with recommended appliances (Lifesling, ladder with platform.)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2007
Resolution: Ladder and "life sling" added to equipment for MOB recovery. Crewman in water if necessary to attach life sling to victim.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 8 October 2007 Resolved
Swing compass and post deviation table.
Due 8 November 2007
Resolved 26 October 2007
Construction/Loadline › Structures › Door
Issued 8 October 2007 Resolved
At next credit drydock, install 6 inch combings on all weathertight doors for continued operation in partially protected waters IAW 176.360(d)(1).
Action required: 705 - Other - as specified
Due 1 May 2009
Resolved 7 May 2010
Resolution: 6 inch combings installed on all weathertight doors.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 October 2007 Resolved
Prove all crew enrolled in approved random drug testing program. Provide evidence of pre-employment neg/res test.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2009
Engineering
Issued 26 April 2000 Resolved
Provide approved flexible fuel hoses that meet SAE J-1942 IAW 46CFR182.720(e) prior to carrying passengers.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Construction/Loadline
Issued 26 April 2000 Resolved
Make watertight the port side collision bulkhead prior to carrying passengers, blkhd has screw holes unplugged.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Construction/Loadline › Penetrations › Bottom Plug
Issued 26 April 2000 Resolved
Make permanent and watertight unused hull penetrations port and stbd side plugged with plastic fittings no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Engineering
Issued 26 April 2000 Resolved
Double clamp port engine exhaust hose no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 1 May 2000
Engineering
Issued 26 April 2000 Resolved
Provide burn shield for port engine fuel filter no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 1 May 2000
Construction/Loadline
Issued 26 April 2000 Resolved
Individual electrical bilge pump discharge hoses improperly joined. Providenew discharge hoses and double clamped prior to carrying passengers.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Construction/Loadline
Issued 26 April 2000 Resolved
Fit all fixed system bilge suction pipes with strainers having an open areanot less than three times the area of the bilge pipe prior to carrying passengers.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Electrical
Issued 26 April 2000 Resolved
Properly mount electrical box on aft end of generator no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 1 May 2000
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 26 April 2000 Resolved
Provide an approval number for the marine sanitation system as a whole IAW 33 CFR 159.7 no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation
Issued 26 April 2000 Resolved
Provide an operational navigational radar IAW 46 CFR 184.404 prior to carrying more than 49 passengers and no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 1 May 2000
Engineering
Issued 26 April 2000 Resolved
Renew flexible fuel lines in stbd engine compartment in accordance with 46 CFR 182.720 prior to carrying passengers.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Engineering
Issued 26 April 2000 Resolved
Repair stbd main engine intermediate aluminum pipe connections (badly corroded) no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 1 May 2000
Construction/Loadline
Issued 26 April 2000 Resolved
Remove T connection in stbd engine compartment bilge pump overboard discharge piping prior to carrying passengers.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Construction/Loadline
Issued 26 April 2000 Resolved
Secure deck hatches in passenger cabin area prior to carrying passengers.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Construction/Loadline
Issued 26 April 2000 Resolved
Provide bilge high level alarms in port and starboard lazarette prior to carrying passengers.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Navigation
Issued 26 April 2000 Resolved
Repair/renew port stuffing box. Provide new hose with double hose clamps toconnect stuffing box assembly to rudder post no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 1 May 2000
Engineering
Issued 26 April 2000 Resolved
Shorten cables for port and stbd generator fuel shut-off valves no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 1 May 2000
Documentation › Logs/Records › Drug Test Records
Issued 26 April 2000 Resolved
Provide evidence of compliance with a random chemical testing program IAW 46 CFR 16 no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Unknown
Issued 26 April 2000 Resolved
Provide method for internal communications IAW 46 CFR 184.602 prior to carrying passengers.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Accommodation/Occupational Safety
Issued 26 April 2000 Resolved
Provide handrail of adequate height at aft deck perimeter (39.5") IAW with 46 CFR 177.900 prior to carrying passengers.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Engineering
Issued 26 April 2000 Resolved
Renew stbd main engine exhaust hose and clamps no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 1 May 2000
Construction/Loadline
Issued 26 April 2000 Resolved
Double clamp all raw water flexible hose connections no later than 19MAY00.
Condition: Unknown
Due 19 May 2000
Resolved 1 May 2000
Construction/Loadline
Issued 26 April 2000 Resolved
Make watertight all electrical penetrations through watertight bulkheads throughout vessel port and stbd side prior to carrying passengers.
Condition: Unknown
Due 1 May 2000
Resolved 1 May 2000
Electrical
Issued 18 March 1994 Resolved
REPLACE MISSING LIGHT FIXTURE COVERS IN UPPER DECK PASSENGER AREA.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Navigation
Issued 18 March 1994 Resolved
DOUBLE NUT OR PIN STEERING LINKAGE.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Construction/Loadline
Issued 18 March 1994 Resolved
RELABEL BILGE MANIFOLD SYSTEM.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Documentation
Issued 30 March 1992 Resolved
PROVIDE PROOF OF FCC OPERATORS LICENSE
Condition: Unknown
Due 14 April 1992
Resolved 2 April 1992
Electrical
Issued 30 March 1992 Resolved
INSTALL FLOURESCENT FIXTURE COVER FOR STBD FWD LIGHT
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Construction/Loadline
Issued 30 March 1992 Resolved
CLEAN BILGE SUCTION STRAINERS FOR INSTALLED BILTGE SYSTEM
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Electrical
Issued 30 March 1992 Resolved
REMOVE WIRENUTS FROM LIGHTING FLOURESCENT FIXTURES AND REPLACE WITH APPROVED CONNECTOR
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Documentation
Issued 30 March 1992 Resolved
PROVIDE PROOF OF COAST GUARD OPERATORS LICENSE
Condition: Unknown
Due 14 April 1992
Resolved 2 April 1992
Accommodation/Occupational Safety
Issued 2 April 1991 Resolved
thru hull continuous threaded nipples for A/C system corroded.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Electrical
Issued 2 April 1991 Resolved
emergency light switches not labeled.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Fire Fighting
Issued 2 April 1991 Resolved
fixed halon sys indicator lights not wire to operating station. system will be removed.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Fire Fighting
Issued 2 April 1991 Resolved
electric fire pump not operational.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Navigation
Issued 2 April 1991 Resolved
missing charts for area of operation and nav. pubs.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Accommodation/Occupational Safety
Issued 2 April 1991 Resolved
bilge manifold valves not properly labled
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Accommodation/Occupational Safety
Issued 2 April 1991 Resolved
overboard discharges not double clamped.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Engineering
Issued 2 April 1991 Resolved
fuel system not properly bonded
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Electrical
Issued 13 July 1990 Resolved
INSTALL PERMANENT INTERLOCKS BETWEEN NO. 1 AND NO.2 GEN AND SHORE TIE BREAKER TO PREVENT ANY CROSS CONNECTING.
Condition: Unknown
Due 13 July 1990
Resolved 13 July 1990
Documentation
Issued 5 July 1990 Resolved
PROVIDE FCC STATION LICENSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Documentation
Issued 5 July 1990 Resolved
PROVIDE FCC RADIOTELEPHONY LICENSE. VESSEL IS LIMITED TO 1000' FROM SHORE UNTIL COMPLETED.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Electrical
Issued 5 July 1990 Resolved
MAKE EMERGENCY CROSSOVER SWITCH (120V AC) AVAILABLE FOR INSPECTION AND PROVIDE PLACARD FOR OPERATION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Electrical
Issued 5 July 1990 Resolved
LABEL ALL ELECTRIC BILGE PUMP SWITCHES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Deck/Cargo
Issued 5 July 1990 Resolved
LABEL ALL FIXED BILGE PUMP SYSTEM VALVES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Lifesaving
Issued 5 July 1990 Resolved
PLACE LIFEJACKETS ONBOARD AND LABEL STOWAGE BINS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Documentation
Issued 5 July 1990 Resolved
POST COI PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Documentation
Issued 5 July 1990 Resolved
POST STABILITY LETTER WHEN RECEIVED.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Deck/Cargo
Issued 5 July 1990 Resolved
FINISH INSTALLING FIXED SEATS (74 LOWER, 35 TOP DECK) PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Documentation
Issued 5 July 1990 Resolved
GET VESSEL ADMEASUREMENT/GROSS TONNAGE DETERMINED.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990
Documentation
Issued 5 July 1990 Resolved
PROVIDE A VALID DOCUMENT FOR THE VESSEL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 July 1990
Resolved 5 July 1990

Casualty record · 1

1 June 2013Routine · role: Involved in a Marine Casualty · activity 4609769
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.