Records from 1990 to 2002. Most recent: inspection, 28 June 2002.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting › International Shore Connection
Issued 15 July 2002
Resolved
PROVIDE A SOLAS APPROVED INTERNATIONAL SHORE CONNECTION. EXISTING SHORE CONNECTION ONBOARD, DOES NOT MEET SOLAS SPECIFICATIONS.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR WASTED BRACKET AT FIRE MAIN ACCESS HOLE AT STBD SIDE, FWD OF CARGO HOLD #5. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR WASTED BRACKET AT FIRE MAIN ACCESS HOLE AT STBD SIDE, AFT CARGO HOLD #4. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Pollution Prevention/Response › Prevention Equipment
Issued 15 July 2002
Resolved
PROVIDE MECHANICAL PLUGS AT ALL CONTAINMENT AREAS. LEGACY COMPONENT DESC: Fixed Containment
Due 15 August 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Deck/Cargo › Holds/Tanks
Issued 15 July 2002
Resolved
REMOVE DOUBLER AND MAKE REPAIR TO COAMING ADJACENT TO #5 WEB, STBD SIDE #4 CARGO HOLD. LEGACY COMPONENT DESC: Coaming
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR FRACTURED BRACKET AFT #3 CARGO HOLD. BRACKET COMING OFF OF DECK AT WELD. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR FRACTURED BRACKET PORT SIDE, AFT OF #3 CARGO HOLD, #4 FROM STBD AT CROSSDECK. BRACKET COMING OFF DECK AT WELD. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Deck/Cargo › Holds/Tanks
Issued 15 July 2002
Resolved
REPAIR WASTED COAMING ADJACENT TO #4 WEB, AT #3 CARGO HOLD, STBD SIDE. ADHESIVE TAPE FOUND ON COAMING AS TEMPORARY REPAIR. LEGACY COMPONENT DESC: Coaming
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Deck/Cargo › Holds/Tanks
Issued 15 July 2002
Resolved
REMOVE DOUBLER AND MAKE REPAIR TO COAMING ADJACENT TO #8 WEB, ON STBD SIDE #3 CARGO HOLD. LEGACY COMPONENT DESC: Coaming
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR WASTED WEB #4, STBD SIDE OF #3 CARGO HOLD. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR WASTED WEB #7 STBD SIDE OF #3 CARGO HOLD. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR WASTED BRACKET AT FIRE MAIN ACCESS HOLE, STBD SIDE, FWD OF #3 CARGO HOLD. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR FRACTURED BRACKET AT TOE AND WELD, #7 FROM PORT AT CROSSDECK, FWD #2 CARGO HOLD. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Deck/Cargo
Issued 15 July 2002
No resolution recorded
REPAIR ALL 6 BASES OF ALL 6 CHOCKS ON FORECASTLE. BASES ARE ALL WASTED ON OUTBOARD SIDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2002 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Occupational Safety
Issued 15 July 2002
Resolved
REPAIR WASTED HANDRAIL, PORT SIDE FORECASTLE, AFT OF THE AFTERMOST CHOCK. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Deck/Cargo › Holds/Tanks
Issued 15 July 2002
Resolved
REPAIR FRACTURED COAMING PORT SIDE, AFT #4 CARGO HOLD. LEGACY COMPONENT DESC: Coaming
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR WASTED WEB #2, IWO TOE BRACKET, PORT SIDE #5 CARGO HOLD. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR WASTED WEB #5, IWO TOE BRACKET, PORT SIDE #5 CARGO HOLD. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR WASTED WEB #9, IWO COMBING, PORT SIDE #5 CARGO HOLD. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Construction/Loadline › Hull
Issued 15 July 2002
Resolved
REPAIR WASTED WEB #11, IWO COAMING, PORT SIDE #5 CARGO HOLD. LEGACY COMPONENT DESC: Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Pollution Prevention/Response › Prevention Equipment
Issued 15 July 2002
No resolution recorded
PROVIDE CONTAINMENT FOR ME LO, ME TC, ME SYS OIL, DO TK, KER TK, ME SB DT, BO TK, AND RES TK VENTS ON PORT SIDE. LEGACY COMPONENT DESC: Fixed Containment
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 August 2002 — due date passed with no resolution recorded
Pollution Prevention/Response › Prevention Equipment
Issued 15 July 2002
No resolution recorded
PROVIDE CONTAINMENT FOR BILGE TK, ME CYL OIL, AND GE LO TANK VENTS, STBD SIDE. LEGACY COMPONENT DESC: Fixed Containment
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 20 August 2002 — due date passed with no resolution recorded
Lifesaving › Lifebuoys
Issued 15 July 2002
Resolved
REPAIR WATERLIGHT AT LIFERING ADJACENT TO PORT LIFEBOAT. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Due 16 July 2002
Resolved 15 July 2002
Resolution: CORRECTED IN FRONT OF PSC OFFICER.
Lifesaving › Buoyant Apparatus › Self-igniting Lights
Issued 15 July 2002
Resolved
REPLACE LIFERING LINE PORT SIDE ADJACENT TO LIFEBOAT.
Condition: Improper/Lack of Maintenance
Due 16 July 2002
Resolved 15 July 2002
Resolution: CORRECTED IN FRONT OF PSC OFFICER.
Fire Fighting
Issued 15 July 2002
No resolution recorded
PROVIDE PROPER LATCH FOR FIRE DOOR ON BRIDGE DECK.
Condition: Improper/Lack of Maintenance
Due 20 August 2002 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 15 July 2002
Resolved
PROVIDE EDB'S IN ACCOMODATION AREA AND MACHINERY SPACE IAW SOLAS CHAPTER II-2, 13.3.4.2, 13.3.4.5, 2000 AMMENDMENTS. MODIFY FIRE CONTROL PLAN TO REFLECT THE SAME.
Due 16 July 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 July 2002
Resolved
PROVIDE GUARD OVER FLYWHEEL AND VACUUM PUMP FOR EMERGENCY FIRE PUMP. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Due 15 August 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.
Fire Fighting
Issued 15 July 2002
Resolved
REPAIR STEEL GALLEY FIRE DOORS, 3 TOTAL. DOORS MUST SELF CLOSE AND LATCH.
Due 15 August 2002
Resolved 21 July 2002
Resolution: Received Class Report attesting to repairs.