MAURY USCG vessel records Sign in
← All vessels

QC ATHINA

QC ATHINA is a 2000 freight ship. The Coast Guard has recorded 19 inspections since 2000, most recently in September 2017, along with 6 deficiencies and 4 operational controls.

Records from 2000 to 2017. Most recent: inspection, 1 September 2017.

Built
2000
Last inspected
1 September 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9208514 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
MARSHALL ISLANDS
—
Maury page id
psix-3499

Inspections, by type

…with no type recorded7
Years with a record 12 calendar years (2000–2017)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it72918 - Dead Weight, Ton
83831 - Displacement, Ton
38684 - Convention (Subpart B), Gross Ton
24591 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 19

1 September 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6253929
4 September 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5234976
4 September 2015 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5235087
4 September 2015 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5235095
10 February 2011 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3937711
8 February 2010 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3670237
1 July 2008 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3254319
14 June 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3227958
14 August 2006 Ballast Water Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2747311
10 August 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2742314
25 August 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2474024
18 August 2005 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2466678
20 February 2005 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2296066
30 May 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2087500
3 December 2003 Deficiency Check · Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1958789
3 January 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1725528
8 January 2002 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1476717
30 August 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 293137
28 March 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 276294

Deficiency record · 6

Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 10 February 2011 Resolved
1499 - Other (Prop & Aux. Machinery) - Each bunker line transfer pipe must be tested annually and not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel conducted annual test, however air was used as medium. Vessel is prohibited from bunkering in US waters until bunker line is static liquid pressure tested. - 33CFR 156.170.
Action required: 703 - Prior to bunkering operations
Due 10 February 2011
Resolved 10 February 2011
Resolution: Received, reviewed and accepted proper documentation from master stating the deficiency was rectified. C/E conducted satisfactory bunker line pressure test in accordance with 33 CFR 156.170.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 10 February 2011 Resolved
0100 - Ship's certificates and document - The transfer procedures required by 33CFR155.720 must contain information either in the order listed in 33CFR155.750 or by use of a cross reference index page. Vessel cannot provide transfer procedures in accordance with 33CFR155.750. Vessel is prohibited from bunkering in US waters until transfer procedures are provided and approved. - 33CFR 155.720.
Action required: 703 - Prior to bunkering operations
Due 10 February 2011
Resolved 23 February 2011
Resolution: Received, reviewed, and accepted proper documentation from master stating the deficiency has been rectified. Vessel generated and provided oil transfer procedures in the format required by 33 CFR 155.750.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 August 2005 Resolved
Can not properly test oily water seperator content meter. Prior to departure
Action required: 705 - Other - as specified
Due 26 August 2005
Resolved 26 August 2005
Resolution: Received class surveyors report attesting to the proper function of the OWS system and oil content meter.
Engineering › Generator (propulsion-electric)
Issued 3 January 2003 Resolved
Generator No. 1 has temporary welded repairs made to seawater cooling inlet piping. Renew piping.
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 3 December 2003
Resolution: Witnessed satisfactory permanent repairs to seawater cooling inlet piping.
Engineering › Generator (propulsion-electric)
Issued 3 January 2003 Resolved
Generator No.3 has temporary welded repairs made to seawater cooling inlet piping. Renew piping.
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 3 December 2003
Resolution: Witnessed satisfactory permanent repairs to piping.
Engineering › Generator (propulsion-electric)
Issued 3 January 2003 Resolved
Generator No. 2 seawater cooling inlet piping has a leak on the expansion joint bottom flange. Repair connection.
Action required: 705 - Other - as specified
Due 17 January 2003
Resolved 3 December 2003
Resolution: Witnessed satisfactory repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.