← All vessels
CATTYWAMPUS
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Heartland District (CGD-H) · Other hulls named CATTYWAMPUS
CATTYWAMPUS is a 1990 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1990, most recently in March 2026, along with 101 deficiencies and 1 casualty investigation in 2012.
Records from 1990 to 2026. Most recent: inspection, 2 March 2026.
- Built
- 1990
- Last inspected
- 2 March 2026
- Documentation
- Expired · documentation file of 10 September 2026
- Deficiencies
- 101 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2012
Identity
964804
WDD8596
349964
Flag
UNITED STATES
367300180
Maury page id
psix-349964
Inspections, by type
…with no type recorded9
Years with a record
34 calendar years (1990–2026)
The 69 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 28.5 ft × 8.0 ft
Registered tonnagegross 14 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOLYMPIC BOAT WORKS, INC · PORT TOWNSEND, WA, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeSail (Faired Keel)
Hull configurationTwin Hull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Recreational, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it14 - Simplified, Gross Ton
14 - Simplified, Net Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD8596MMSI 367300180 · active · compulsorily equipped · granted 6 May 2017, expires 29 June 2027
WBL3166MMSI not assigned · expired · compulsorily equipped · granted 1 July 1997, cancelled 24 November 2007 · licensed under a name not among this hull’s recorded names (not shown)
WAN7254MMSI not assigned · expired · voluntarily equipped · granted 11 August 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 69
2 March 2026
Vessel Attendance · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8318815
10 February 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8077314
7 November 2024
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8031968
10 April 2024
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7893096
2 April 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7888989
10 April 2023
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7666371
19 December 2022
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7610806
31 May 2022
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7464445
9 March 2022
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7409300
20 April 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7179692
23 November 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7101231
10 March 2020
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6921772
4 June 2019
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6704250
21 February 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6630492
24 May 2018
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6416996
24 May 2017
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6154094
2 May 2017
Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6141744
16 February 2017
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6088000
29 June 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5923891
20 May 2014
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4863087
28 May 2012
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4330978
15 September 2011
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4146149
4 November 2010
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3884577
20 October 2010
Type not recorded
No type recorded · USCGC VIGILANT (WMEC 617) · Activity 3901081
7 September 2010
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3837872
11 May 2009
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3494167
7 May 2009
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3452245
14 April 2009
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3468903
26 June 2007
COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2981688
9 April 2007
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2902160
10 July 2006
Deficiency Check · Re-Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2708212
3 April 2006
Hull Examination
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2628369
1 June 2005
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2375874
22 September 2004
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2202285
26 June 2004
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2111022
5 August 2003
Periodic Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1866042
28 May 2003
Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1820626
3 September 2002
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1670159
31 July 2001
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1444581
21 May 2001
Hull Examination
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1362385
19 June 2000
COI Inspection · Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1444357
2 October 1999
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1041111
28 July 1999
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1384214
27 May 1999
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 801432
11 March 1999
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 809579
8 July 1998
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1447846
25 July 1997
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1419807
20 June 1997
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1388321
31 May 1996
Hull Examination · COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1400358
17 October 1995
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 882745
11 October 1995
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 655238
14 September 1995
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1440978
24 August 1995
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1409353
12 July 1994
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1176947
27 May 1994
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1431365
16 August 1993
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1472660
9 August 1993
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1373905
2 August 1993
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1393980
24 June 1993
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1358106
20 July 1992
Damage Survey
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 949158
19 July 1992
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 101940
2 June 1992
Plan Review "T" Boat · Re-Inspection · Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1472090
29 August 1991
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 937729
9 August 1991
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1244382
22 July 1991
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 939806
5 June 1991
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 922706
30 July 1990
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 899457
18 July 1990
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1295619
14 June 1990
Initial Construction-Excluding Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1219897
Deficiency record · 101
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2024
Resolved
Type I PFD donning placard must be posted for each style of PFD carried onboard.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 2 April 2024
Resolved
Vessel's DSC radio must be programmed with vessel's GPS location.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 December 2022
Resolved
Inspect hull in accordance with 46 CFR 176.600. Port steering compartment aft hull was deteriorated in lower outboard corner.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 23 November 2020
Resolved
Vessel has removed both dagger boards, glassed over openings and inserted approximately 700lbs of rock ballast in dagger board voids. Remove unauthorized modifications and provide repair proposal prior to carrying passengers.
Communications › Radio Communications › EPIRB
Issued 24 May 2017
Resolved
Provide current EPRIB Registation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 June 2016
Resolved
Complete a credit annual exam. Annual exam is overdue as of 24May16.
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 November 2010
Resolved
Prior to carrying passengers, provide and permanently install engine starting batteries in a battery box lined with, or constructed of, a material that is resistant to damage by the electrolyte as per 46 CFR 183.350(e).
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 4 November 2010
Resolved
Prior to carrying passengers, remove each existing 28 gallon portable plastic gasoline storage fuel tanks and replace with ABYC H-25 Standard portable plastic gasoline storage tanks not to exceed twelve (12) gallons capacity each as per 46 CFR 182.458(b) and MSM.
Engineering › Steering Gear System › Linkage
Issued 9 September 2010
Resolved
Replace deteriorated clevis linking steering and pins
Construction/Loadline › Hull › Keel
Issued 7 May 2009
Resolved
Make repairs to port rudder, port dagger board, and stern.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 April 2009
Resolved
Vessel's drydock, and internal structural exam (DD/ISE) date expired on issued Certificate of Inspection. De-activated COI. Vessel will be required to undergo a DD/ISE, and a Renewal of COI exam prior to carrying passengers.
Construction/Loadline › Structures › Superstructure
Issued 9 April 2007
Resolved
Make the mast ready for inspection in way of having it mounted as per 46 CFR 176.610.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 April 2007
Resolved
Make the deck rail spacing meet the requirements of 46 CFR 177.900.
Engineering › Bilge Water Management System › Pump
Issued 9 April 2007
Resolved
Properly mount the independent bilge pumps as per 46 CFR 182.520.
Engineering › Bilge Water Management System › Valve
Issued 9 April 2007
Resolved
Provide a positive shut off valve at the hull penetration for the independent bilge pump discharge lines as per 46 CFR 182.520
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 April 2007
Resolved
Provide approved plans or submit plans for approval for the modification and or relocation of the out board engines as per 46 CFR 176.700
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 April 2007
Resolved
Provide approved plans or submit plans for approval for the modification and or relocation of the out board engines as per 46 CFR 176.700
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 July 2006
Resolved
Prior to operating perform annual service on portable fire extinguishers.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 July 2006
Resolved
Limited to daylight operations only until waterlight is repaired and mounted with a corrosion resistant clip and retro reflective tape is installed on ring buoy.
Documentation › Certificates/Documents › FCC SSL
Issued 10 July 2006
Resolved
Limited to no more than 1000' from shore until FCC station license is provided.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 10 July 2006
Resolved
Limited to no more than 44 persons until proper number of PFD's are provided as per COI.
Engineering › Bilge Water Management System › Pump
Issued 10 July 2006
Resolved
Remount stbd bilge pump.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 July 2006
Resolved
Install battery hold down straps on batteries.
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 July 2006
Resolved
Perform drills in presense of CG Marine Inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 April 2006
Resolved
Properly wire bilge pumps IAW 46 CFR 183.340, if wire nut are to be used must be installed to comply with (i) of provided cite.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 April 2006
Resolved
Replace hose for installed Marine Sanitation Device connection to take. Arrangement must comply with 46CFR184.704.
Lifesaving › Lifebuoys › Serviceable
Issued 26 June 2004
Resolved
replace grab line around ring buoy
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 June 2004
Resolved
conduct drills in the presence of USCG inspector
Engineering › Gasoline Engine (auxiliary) › Cylinder (4 cycle)
Issued 26 June 2004
Resolved
Prove proper operation of start in gear protection on outboard engine as required in 46CFR183.710.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 5 August 2003
Resolved
Locate B-1 fire Extinguisher at helm using approved mounting bracket.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 5 August 2003
Resolved
Locate sound producing devise at helm station.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 3 September 2002
Resolved
Evaluate / prove that newly installed trampoline netting is safe for allowance for passengers.
Documentation
Issued 19 June 2000
Resolved
Provide proof of user fees being paid.
Documentation
Issued 19 June 2000
Resolved
Provide proof of contract with drug testing consortium and crew list.
Construction/Loadline
Issued 11 March 1999
Resolved
VESSEL CAN NOT OPERATE WITH PASSENGERS UNTIL IT IS IN COMPLIANCE WITH THE NEW BILGE SYSTEM REQUIREMENTS.
Documentation
Issued 8 July 1998
Resolved
Provide proof of drug testing program and information for audit.
Lifesaving
Issued 8 July 1998
Resolved
Provide replacement for broken life ring in accordance with 46CFR180.70(c) and marked with retro reflective tape IAW 46CFR185.604(i)
Documentation
Issued 8 July 1998
Resolved
Provide proof of licensed master of auxiliary Sail.
Construction/Loadline
Issued 20 June 1997
Resolved
MAKE OPERATIONAL THE HAND BILGE/FIRE PUMP. AN EXTENTION NEEDS TO BE ADDED TO PUMP SUCTION AND DISCHARGE SO SUCTION MAY BE TAKEN FROM DECK OF VESSEL FOR BOTH FIRE FIGHTING AND EMERGENCY DEWATERING. VESSEL IS ABLE TO FIGHT FIRE W/ EXTINGUISHERS AND BUCKETS OF WATER, ALL BILGES HAVE SEPARATE PUMPS.
Construction/Loadline
Issued 20 June 1997
Resolved
REPLACE HATCH HANDLES AS APPROPRIATE, ON WEATHERTIGHT COMPARTMENT HATCHES TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Navigation
Issued 20 June 1997
Resolved
UPDATE CHARTS AND LIGHT LIST IN AREA OF OPERATION.
Documentation
Issued 31 May 1996
Resolved
Develop and implement procedures for documenting crew training and test of EPIRB per 46 CFR 184/185 [NEW T].
Fire Fighting
Issued 31 May 1996
Resolved
Replace or recharge to the satisfaction of the attending USCG marine inspector vessel's B-I uncharged fire extinguisher.
Construction/Loadline
Issued 31 May 1996
Resolved
Demonstrate the proper operation of the aft starboard pontoon bilge pump tothe satisfaction of the attending USCG marine inspector.
Navigation
Issued 31 May 1996
Resolved
Install to the satisfaction of the attending USCG marine inspector cotter pins in the port and starboard steering arm joint pins.
Lifesaving
Issued 31 May 1996
Resolved
Demonstrate to the satisfaction of the attending USCG marine inspector compliance with the provisions of 46 CFR 16 relating to drug testing programs including the pre-employment testing of crewmembers, enrollment ofsaid employees in a random testing program and availability of an EAP.
Lifesaving
Issued 31 May 1996
Resolved
Mark flare box "Distress Signals" in accordance with the provisions of 46 CFR 185.614 [NEW T] to the satisfaction of the attending USCG marine inspector.
Navigation
Issued 31 May 1996
Resolved
Place onboard ship's bell iaw the provisions of Inland Navrule 33 to the satisfaction of the attending USCG marine inspector.
Documentation
Issued 31 May 1996
Resolved
Post to the satisfaction of the attending USCG marine inspector stability letter issued by G-MSC-1 on 12JUL90.
Lifesaving
Issued 31 May 1996
Resolved
Replace to the satisfaction of the attending USCG marine inspector net restraining ropes.
Lifesaving
Issued 31 May 1996
Resolved
Demonstrate to the satisfaction of the attending USCG marine inspector thatthe vessel is equipped with at least two operable portable battery lights iaw 46 CFR 183.430 [NEW T].
Lifesaving
Issued 31 May 1996
Resolved
Demonstrate to the satisfaction of the attending marine inspector that the vessel has onboard required number (49) of satisfactory adult type 1 approved PFDs.
Navigation
Issued 31 May 1996
Resolved
Reinstall to the satisfaction of the attending USCG marine inspector compass illumination battery.
Electrical
Issued 31 May 1996
Resolved
Demonstrate operation of the vessel's deck lights to the satisfaction of the attending USCG marine inspector.
Accommodation/Occupational Safety
Issued 31 May 1996
Resolved
Reinstall vessel's toilet to the satisfaction of the attending USCG marine inspector.
Lifesaving
Issued 31 May 1996
Resolved
Update vessel's emergency instructions iaw 46 CFR 185.510 and .512 [NEW T] to the satisfaction of the attending USCG marine inspector.
Lifesaving
Issued 31 May 1996
Resolved
Post the Emergency Broadcast Placard iaw 46 CFR 184.506 and .510 [NEW T] tothe satisfaction of the attending USCG marine inspector.
Construction/Loadline
Issued 31 May 1996
Resolved
Tighten partially installed screws and install missing screws on underside of port net retaining bracket to the satisfaction of the attending USCG marine inspector.
Lifesaving
Issued 31 May 1996
Resolved
Obtain and post PFD placards containing donning instructions iaw 46 CFR 185.516 [NEW T].
Documentation
Issued 31 May 1996
Resolved
Demonstrate to the satisfaction of the attending USCG marine inspector compliance with FCC requirements relating to the possession of a valid Great Lakes Radiotelephony Certificate.
Navigation
Issued 31 May 1996
Resolved
Correct to the satisfaction of the attending marine inspector vessel's navigation charts, light list, and coast pilot for route of operation.
Construction/Loadline
Issued 24 August 1995
Resolved
Repair to the satisfaction of the attending Coast Guard marine inspector port and stbd fore and aft dagger board crash blocks.
Construction/Loadline
Issued 24 August 1995
Resolved
Have conducted a drydock examination by an attending Coast guard marine inspector in accordance with the provisions of 46 CFR 176.15.
Construction/Loadline
Issued 24 August 1995
Resolved
Install missing port pontoon aft hatch securing mechanism to the satisfaction of the attending Coast Guard marine inspector.
Construction/Loadline
Issued 24 August 1995
Resolved
Reestablish the integrity of the port pontoon collision bulkhead by reinstalling the three missing 6.5" diameter access ports to the satisfaction of the attending Coast Guard marine inspector.
Construction/Loadline
Issued 24 August 1995
Resolved
Repair to the satisfaction of the attending Coast Guard marine inspector dmg iwo port pontoon stem.
Documentation
Issued 24 August 1995
Resolved
Provide to the satisfaction of the attending Coast Guard marine inspector satisfactory evidence of renewal of Certificate of Documentation.
Engineering
Issued 24 August 1995
Resolved
Prior to the carriage of passengers for hire demonstrate satisfactory operation of starboard pontoon outboard motor.
Documentation
Issued 24 August 1995
Resolved
Provide to the satisfaction of the attending Coast Guard marine inspector satisfactory evidence that a current Light List and Coast Pilot is onboard the vsl as required by 46 CFR 185.20-35.
Documentation
Issued 24 August 1995
Resolved
Demonstrate to the satisfaction of the attending Coast Guard marine inspector satisfactory evidence of compliance with the drug test program provisions of 46 CFR 16.
Lifesaving
Issued 24 August 1995
Resolved
Conduct in the presence of a Coast Guard marine inspector a satisfactory underway fire and man overboard drill.
Documentation
Issued 24 August 1995
Resolved
Prior to the carriage of passengers for hire post emergency checkoff list required by 46 CFR 185.25.
Electrical
Issued 9 August 1993
Resolved
Install lighting to the satisfaction of the cognizant OCMI in stbd pontoon stairway.
Engineering
Issued 24 June 1993
Resolved
INSTALL AND DEMONSTRATE OPERATION OF THE STARBOARD OUTBOARD ENGINE.
Navigation
Issued 24 June 1993
Resolved
DEMONSTRATE OPERATION OF THE COMPASS LIGHT.
Engineering
Issued 24 June 1993
Resolved
PROPERLY INSTALL THE IGNITION SWITCH FOR THE PORT OUTBOARD ENGINE.
Engineering
Issued 24 June 1993
Resolved
REINSTALL FUEL TANK IN PROPER LOCATION ON DECK.
Lifesaving
Issued 24 June 1993
Resolved
STOW CHILD'S PFD'S SEPARATELY FROM ADULT PFD'S.
Accommodation/Occupational Safety
Issued 24 June 1993
Resolved
MAKE A PROPOSAL FOR ENCLOSING THE SPACE BELOW THE UPPER COURSE OF THE LIFELINES ON THE SIDES OF THE VESSEL TO THE [name withheld] 15JUL93. INSTALLATION TO BE COMPLETED NLT 31JUL93. REF: 46 CFR 177.35-1(c).
Fire Fighting
Issued 24 June 1993
Resolved
INSTALL THE B-I PORTABLE FIRE EXTINGUISHER.
Documentation
Issued 24 June 1993
Resolved
POST THE EMERGENCY CHECKOFF LIST.
Navigation
Issued 24 June 1993
Resolved
PROVIDE FOG BELL, ANCHOR BALL AND CONE DAYSHAPES.
Fire Fighting
Issued 24 June 1993
Resolved
PROVIDE BRACKETS AND MOUNT TWO B-II PORTABLE FIRE EXTINGUISHERS.
Documentation
Issued 2 June 1992
Resolved
Provide evidence that a sufficient number of crewmembers hold valid fcc operator permits so that at least one crewmember, with a permit, is on board whenever the vessel is operated. vessel is restricted to not more than 1000' offshore until completed.
Documentation
Issued 2 June 1992
Resolved
Provide great lakes radiotelephony certificate. Vessel may not operate on the Great Lakes, (beyond the break wall,) until completed.
Deck/Cargo
Issued 2 June 1992
Resolved
Provide sutible second anchor.
Navigation
Issued 2 June 1992
Resolved
Provide red and green running lights in accordance with rules for power boat.
Construction/Loadline
Issued 2 June 1992
Resolved
Make permanent fitting to starboard forward bilge pump.
Accommodation/Occupational Safety
Issued 22 July 1991
Resolved
INSTALL RETAINING DEVICE FOR TRAMPOLINE SUPPORT CONNECTING PINS ON STARBOARD SIDE._x001C_ _x001C_ _x001C_
Navigation
Issued 5 June 1991
Resolved
PROVIDE A CURRENT COPY OF THE CHART OF THE VESSELS AREA OF OPERATION._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 5 June 1991
Resolved
PROVIDE CURRENT COPY OF THE COAST GUARD LIGHT LIST FOR AREA OF OPERATION._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 5 June 1991
Resolved
PROPERLY MOUNT IGNITION SWITCH FOR PORT OUTBOARD ENGINE._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 5 June 1991
Resolved
REPAIR HATCH DOG ON STARBOARD HULL FORWARD ACCESS HATCH._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 5 June 1991
Resolved
COMPLETE INSTALLATION OF WEB BELTING IN BOTH TRAMPOLINES, (MISSING ABOUT 15TO 20 FT OF WEB BELTING IN EACH TRAMPOLINE.)_x001C_ _x001C_ _x001C_
Electrical
Issued 5 June 1991
Resolved
REMOVE DEAD WIRE RUNS FROM VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 5 June 1991
Resolved
PROVIDE SOUND PRODUCING DEVICE. THIS ITEM REQUIRED BEFORE VESSEL CAN GET UNDER WAY._x001C_ _x001C_ _x001C_
Navigation
Issued 5 June 1991
Resolved
PROVIDE CURRENT COPY OF THE U.S. COAST PILOT - GREAT LAKES_x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 5 June 1991
Resolved
PROVIDE AN ANCHORING DAYSHAPE._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 5 June 1991
Resolved
PROVIDE A CURRENT COPY OF THE RULES OF THE ROAD._x001C_ _x001C_ _x001C_ _x001C_
Navigation
Issued 18 July 1990
Resolved
PROVIDE ON BOARD AND POST NECESSARY FCC RADIO CERTIFICATES. UNTIL PROVIDED,VESSEL IS LIMITED TO WITHIN 1000 FT. OF SHORE.
Lifesaving
Issued 18 July 1990
Resolved
PROVIDE ON BOARD ONE ADDITIONAL ADULT TYPE LIFE PRESERVER TO BRING TOTAL TO49. UNTIL PROVIDED, VESSEL IS LIMITED TO 44 PASSENGERS.
Casualty record · 1
28 May 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4330978
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
EMERALD DANCER (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.