Records from 1990 to 2003. Most recent: inspection, 21 May 2003.
Documentation record
Registered dimensions (L × B × D)57.0 ft × 20.0 ft × 5.0 ft
Registered tonnagegross 47 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builder3-M LIFT BARGES INC · GALLIANO LA, UNITED STATES · built 1966
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itUnclassified
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Simplified, Gross Ton
38 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
21 May 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1814157
23 July 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189880
2 December 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1159630
15 October 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370715
26 June 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391774
31 March 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425259
25 February 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 951495
3 December 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1251814
6 September 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936185
6 September 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938105
19 June 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205617
7 August 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211068
6 July 1990
Initial Certification · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926083
29 June 1990
Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915269
Construction/Loadline
Issued 15 October 1993
Resolved
CROP AND RENEW DAMAGED CORNER OF STARBOARD AFT LEG PAD.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Electrical
Issued 15 October 1993
Resolved
REWIRE PANEL BOX AND INSTALL JUNCTION BOXES FOR WIRING SYSTEM PILOT HOUSE HELM CONSOLE.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Documentation
Issued 15 October 1993
Resolved
PROVIDE ONBOARD VESSEL COPY OF STABILITY LETTER ISSUED BY USCG MSO MORGAN CITY UPON ISSUANCE AND RECEIPT.
Condition: Unknown
Due 31 December 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 15 October 1993
Resolved
RENEW DAMAGED FRAME AND DIAGIONAL IN STEERING COMPT.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Documentation
Issued 15 October 1993
Resolved
PROVIDE ONBOARD VESSEL COPY OF APPROVED OPERATIONS MANUAL UPON RECEIPT.
Condition: Unknown
Due 15 December 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 6 September 1991
Resolved
PROVE OPERATION OF BOTH GENERATOR OVERSPEEDS. 46 CFR 183.10-35
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Accommodation/Occupational Safety
Issued 6 September 1991
Resolved
MOUNT POLLUTION PLACARD. 33 CFR 151.59
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Lifesaving
Issued 6 September 1991
Resolved
PROVE PROPER OPERATION ALARM PANEL IN PILOT HOUSE.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Electrical
Issued 6 September 1991
Resolved
RENEW AS ORIGINAL OR REMOVE ALL OPEN WIRE SPLICING IN ENGINE ROOM. PROVIDEJUNCTION BOX FOR FUSES. 46 CFR PART 183.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Navigation
Issued 6 September 1991
Resolved
PROVIDE CURRENT COPY OF NAVIGATIONAL RULES.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Lifesaving
Issued 6 July 1990
Resolved
PROVIDE MOUNTING RACK FOR RESCUE BOAT AND SLING.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Fire Fighting
Issued 6 July 1990
Resolved
PROVIDE GAUGE FOR FIRE PUMP.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Electrical
Issued 6 July 1990
Resolved
PROVIDE GUARD ON ALTERNATOR BELT AND FAN FOR GENERATOR.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Documentation
Issued 6 July 1990
Resolved
SUBMIT AN OPERATING MANUAL MEETING THE APPLICABLE SECTIONS OF 46 CFR 109.121 TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Engineering
Issued 6 July 1990
Resolved
PROVIDE REACH RODS FOR SHUT OFF OF BOTH FUEL OIL TANKS.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Construction/Loadline
Issued 6 July 1990
Resolved
PROVIDE ADDITIONAL GUARD RAIL IN ADDITION TO ONE ALREADY INSTALLED AROUND ENTIRE VESSEL.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Construction/Loadline
Issued 6 July 1990
Resolved
PROVIDE GAUGING REPORT OF SHELL PLATING.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Construction/Loadline
Issued 6 July 1990
Resolved
PROVIDE A REPORT OF ULTRASONIC TESTING ON ALL LEG BUTT WELDS AND LEG TO PAD CONNECTIONS.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Construction/Loadline
Issued 6 July 1990
Resolved
MAKE REPAIRS TO ENGINE ROOM BILGE ALARM.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Documentation
Issued 6 July 1990
Resolved
PLACE THE U.S. COAST GUARD CERTIFICATE OF DOCUMENTATION ON BOARD AND MAIL A COPY TO [name withheld].
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Documentation
Issued 6 July 1990
Resolved
SUBMIT PLANS SHOWING GENERAL ARRANGEMENT, INBOARD AND OUTBOARD PROFILE, A STRUCTURAL ANALYSIS OF ALL LEGS AND LEG TOWER SUPPORTS AND FAIL SAFE SYSTEM TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990
Documentation
Issued 6 July 1990
Resolved
SUBMIT STABILITY CALCULATIONS TO THE U.S. COAST GUARD MARINE SAFETY CENTER FOR ISSUANCE OF A STABILITY LETTER.
Condition: Unknown
Due 6 July 1990
Resolved 6 July 1990