MAURY USCG vessel records Sign in
← All vessels

UBC SYDNEY

UBC SYDNEY is a 2001 freight ship. The Coast Guard has recorded 53 inspections since 2001, most recently in July 2023, along with 13 deficiencies and 11 operational controls.

Records from 2001 to 2023. Most recent: inspection, 11 July 2023.

Built
2001
Last inspected
11 July 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9236078 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
CYPRUS
—
Maury page id
psix-35009

Inspections, by type

…with no type recorded10
Years with a record 21 calendar years (2001–2023)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it39034 - Displacement, Metric Ton
31759 - Dead Weight, Metric Ton
19746 - Convention (Subpart B), Gross Ton
10669 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 53

11 July 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7736045
10 July 2023 COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7738262
9 May 2023 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7680979
8 May 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7684076
26 July 2022 Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7513067
26 May 2022 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7457209
26 May 2022 Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 7459638
23 May 2022 COE-Administrative
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7457250
19 April 2022 Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7433788
18 April 2022 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7433311
18 April 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7433345
20 February 2022 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7399101
16 February 2022 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7397123
7 September 2021 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7306064
10 August 2021 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7282233
18 September 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7061076
31 August 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7046437
27 February 2020 PSC B · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6913362
25 November 2019 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6861930
21 November 2019 Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6859984
14 August 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6783202
14 February 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6625686
2 July 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6459901
17 June 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6440722
5 December 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6312716
22 December 2016 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6058454
20 June 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5909034
5 October 2014 COE-Dockside · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4994657
26 June 2012 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 4351173
16 January 2011 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3926807
16 February 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3677691
8 February 2010 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3677005
3 February 2009 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3411659
3 February 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3411962
27 January 2009 COE-Dockside
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3399051
23 October 2008 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3350429
29 August 2008 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3312309
6 May 2008 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3200295
10 May 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2926945
8 May 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2922220
6 March 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2596650
24 June 2005 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2397953
1 February 2005 Annual Inspection · PII Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2284215
17 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2243354
27 August 2004 STCW 95 Exam · ILO-147 Exam · NPV Safety Exam · MARPOL Annex V Examination · ISM Exam · MARPOL Annex I Examination · Loadline Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2174806
2 July 2004 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2116457
17 December 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1966386
26 August 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1888185
18 May 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1795823
10 March 2003 Administrative Inspection
Administrative · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1755200
25 November 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1710501
10 March 2002 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1490813
13 September 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 293635

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 May 2022 Resolved
FIRE FIGHTING SYSTEM AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER. WHILE ON DECK WALK, PSCO FOUND CO2 LINE TO CARGO HOLD #3 AFT PORT SIDE PAINTED YELLOW NOTATING LEAK. REVIEWED SMS AND DISSCUSSED LEAK WAS FOUND 3 DAYS PRIOR. SHIPS CREW WILL REPAIR LEAK ON PIPE WITH NEW. NO CARGO IS TO BE LOADED IN HOLD #3 UNTIL REPAIR IS MADE, CLASS ATTENDS AND LEAK TEST IS PASSED. 74SOLAS(20)II-2/14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 July 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 19 April 2022 Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the Administration. A second source of energy shall be provided unless manual starting can be demonstrated to be effective. Emergency generator's secondary starting battery is inoperable. 74SOLAS(04) II-1/44.2 Action Taken: 17ac/10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 19 April 2022
Resolution: Crew replaced battery and PSCO witnessed satisfactory operation.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 19 April 2022 Resolved
Immersion suits shall be so placed as to be readily accessible and their position shall be plainly indicated. PSCO observed 04 immersion suits on the bridge where the Fire [name withheld] indicated 05 immersion suits are required. 74SOLAS(20) III/32.3.4 Action Taken: 10c
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 19 April 2022
Resolution: 01 extra immersion suit stowed in foreward hold was moved to bridge. PSCO verified 02 suits remained forward, and 05 suits were on bridge IAW Fire Control Plan.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 16 February 2022 Resolved
07108 - FIRE-FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED THE GENERAL SERVICE AND FIRE PUMP ACTIVELY LEAKING WATER. 74SOLAS(04)II-2/14.2.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2022
Resolved 20 February 2022
Resolution: Received Class Survey Report rectifying this deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2022 Resolved
07199 - MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED FUEL OIL LEAKS ON THE SIDE OF THE MAIN ENGINE BY CYLINDERS, ON AUXILARY GENERATOR NO. 1, AND ON 3 VALVES ON THE HFO SETTLING TANK. 74SOLAS(04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2022
Resolved 20 February 2022
Resolution: Received Class Survey Report rectifying this deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 February 2022 Resolved
11101 - ALL LIFE-SAVING APPLIANCES SHALL BE FITTED WITH RETRO-REFLECTIVE MATERIAL WHERE IT WILL ASSIST IN DETECTION. THE RETO-REFLECTIVE TAPE ON THE LIFEBOAT WAS DETERIORATED. 74SOLAS(20)III/34 LSA 1.2.2.7
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 March 2022
Resolved 20 February 2022
Resolution: Received Class Survey Report rectifying this deficiency.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 10 August 2021 Resolved
SHIPS SHALL BE DESIGNED, CONSTRUCTED AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL MECHANICAL, AND ELECTRONIC REQUIREMENTS OF A CLASS SOCIETY. INSET OBSERVED WITH DEFORMATION OF INTERIOR FRAME.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 10 August 2021
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 August 2021 Resolved
FIREPROOF LIFELINE OF SUFFICIENT LENGTH AND STRENGTH SHALL BE PROVIDED. LIFELINE DOES NOT HAVE DOCUMENTATION ATTESTING TO IT BEING FIREPROOF.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 September 2021
Resolution: received class report clearing def
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 August 2021 Resolved
THE MECHINERY, BOILERS, AND OTHER PRESSURE VESSELS ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED. JACKET WATER COOLING WATER LEAK ON GENERATOR NUMBER 02 CYLINDER 02 TOP END.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 September 2021
Resolution: received class report clearing def
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 31 August 2020 Resolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Vessels main engine governor was found unstable by ships crew from the "ECR" command. Ship crew is currently using the main engine from "engine side". 74SOLAS(2004) Ch. II-1, Reg. 31.1
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 September 2020
Resolution: SECNOLA PSC ARRIVALS BRANCH RECIEVED CLASS REPORT FORM DNV GL ATTESTING TO THE REPAIRS.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 14 August 2019 Resolved
Every ship of 100GT or more shall carry a garbage management plan which the crew shall follow. PSCO observed excessive amounts of garbage in the bosun stores producing a strong odor and surrounded by flies. MARPOL V/10.2 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2019
Resolution: The reciept of garbage disposal to shore was recieved & reviewed. Over 90 bags of garbage was removed from the vessel.
14 - Pollution Prevention › 147 - Anti-Fouling › Other (AFS)
Issued 14 August 2019 Resolved
The Master, Owner, Operator or person in charge of any vessel operating in waters of the U.S. must remove fouling organisms from the vessles hull. PSCO observed growth along the lenght of the vessels hull. 33 CFR 151.2050(f) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2019
Resolved 21 November 2019
Resolution: Vessel provided proof of hull cleaning conducted in Panama on 30AUG2019 and members from Sector NNE conducteda hull inspection pier side.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 August 2019 Resolved
Whenever events cause NOA information submitted for a vessle to become inaccurate teh owner, agent, master or person in charge of the vessel must submit and update. The vessles updated departure date was not updated on the NOA. 33 CFR 160.208(a) 10c
Action required: 10 - Deficiency Rectified
Resolved 25 November 2019
Resolution: Deficiency was 10c on vessel.

Ownership record