Records from 2016 to 2025. Most recent: inspection, 5 November 2025.
Inspection history · 32
5 November 2025
Internal Structural Exam · Drydock Exam · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8264487
12 August 2025
Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8207367
19 September 2024
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7999411
16 November 2023
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7824388
6 September 2023
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7786303
8 June 2023
Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7709453
31 January 2023
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7629496
16 December 2022
In-Service Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7624676
22 August 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7536369
16 November 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7352383
30 August 2021
COI Inspection · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7300122
6 July 2021
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7247003
19 August 2020
Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7037361
15 January 2019
Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6608957
14 November 2018
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6580417
14 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6511378
3 May 2018
Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6405078
20 March 2018
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6375524
26 February 2018
Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6362293
14 December 2017
Deficiency Check · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6325051
28 September 2017
In-Service Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6290793
12 July 2017
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6207101
10 April 2017
In-Service Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6122327
13 January 2017
Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6069869
14 October 2016
Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6022875
8 September 2016
Examination of Repairs · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6017936
4 August 2016
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5962358
6 June 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5898677
21 March 2016
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5837189
10 March 2016
Administrative Inspection · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5830906
29 February 2016
Drydock Extension
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5825062
29 January 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5809390
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2025
Resolved
A fixed-gas fire extinguishing system must be capable to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Main diesel engine number 4 failed to shut-off during the fixed-gas fire system test.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2025
Resolution: A solenoid was found damaged, then replaced and retested. Corrected on the spot 10C.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 August 2025
Resolved
Each hatch exposed to the weather must be watertight. Engine Room cargo deck access hatch was found leaking water into the engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2025
Resolution: Hatch was readjusted, 10c. Corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 August 2025
Resolved
Each hatch exposed to the weather must be watertight. Engine Room center main cargo deck access hatch was found leaking water into the engine room. Main engine room access hatch was found not sealing watertight. Engine room is a Co2 protected space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2025
Resolution: Hatch was readjusted, 10C. Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 August 2025
No resolution recorded
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Exhaust leaks were identified in several locations on top of the lagging in all 04 main diesel engines, engine room exhaust piping. Once exhaust leaks are corrected, provide a report to the USCG about findings and repairs conducted. CODE &)% to be corrected for next dry dock credit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 August 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The Notifier indicator panel located in the main deck portside was found to have its main cover door not closing properly as its box frame loose, the access key in the lock accessible to passengers, and marked as restricted area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 20 August 2025
Resolution: Readjusted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 August 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Coast Guard Light List;(4) Tide tables; and(5) Current tables. Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Vessel is missing updated current and tide tables, and Light List.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 20 August 2025
Resolution: Publications have been updated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 August 2025
Resolved
Connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. All connecting devices must be suitable for copper stranded conductors. Correct dead-end wires found in under the operating station, and in the fire detection panel main deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 20 August 2025
Resolution: All dead-end wires were secured.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 November 2023
Resolved
Explosion-proof equipment and intrinsically safe systems must meet the requirements of 111.105 in subchapter J of this chapter. Aft stbd deck light cover is broken. Replace or repair t manufacturer specifications. Hazardous cargo operations are restricted to daylight operations only. Crew must electrically isolate/tag out deck lighting prior to loading hazardous cargo and log in the ship's log.
46 CFR 183.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2023
Resolved 16 November 2023
Resolution: Vessel rep submitted images of replaced deck lighting fixture.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 November 2023
Resolved
Gauges to indicate revolutions per minute (RPM) must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. #2 port MDE RPM gauge at the helm is not providing an accurate reading. Repair or replace.
46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2023
Resolved 17 November 2023
Resolution: Vessel rep submitted video of rpm gauge functioning properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 June 2023
Resolved
In systems were flexible hoses are permitted to be clamped double hose clamping is required. Port and starboard generator raw water flexible hoses have one clamp installed.
46 CFR 182.410(d)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 16 June 2023
Resolution: Hose clamps were properly installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 June 2023
Resolved
All exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR”. Engine room starboard emergency escape hatch is not labeled.
46 CFR 185.606
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 16 June 2023
Resolution: Engine room starboard emergency escape hatch was properly labeled.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 June 2023
Resolved
The cognizant OCMI may require that a vessel undergo additional test deemed reasonable and necessary to determine that the vessel is suitable for the service in which they are employed. Port void forward of fuel tank hull plating above and below longitudinal beam in way of ladder is required to be gauged for thickness.
46 CFR 176.840 Code 705 By next dry dock.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 July 2023
Resolved 24 October 2023
Resolution: gauged as required
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 June 2023
Resolved
A hatch exposed to the weather must be watertight. Engine room starboard emergency escape hatch “knife edge” has been covered with a rubber channel and silicone. Return “knife edge” to original metal design.
46 CFR 179.360 Code 705 by next dry dock
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 July 2023
Resolved 1 November 2023
Resolution: Adjusted dogs and conducted satisfactory hose test with firemain
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 August 2022
Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Stability letter was not posted at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 8 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 August 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices and other hazardous situations must be corrected. During the MOB drill, MI's observed free swinging doors at the bulwark rescue gate. When the vessel crew prepare to rescue a person in the water (PIW), a rescue ladder is attached to the bulwark and the bulwark rescue gate is opened. While the vessel is being maneuvered to recover a PIW the rescue gate doors swing freely. This presents a hazard to the crew and to the person being recovered. Bulwark rescue gate doors must have a means of latching them open to minimize potential injuries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 8 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2022
Resolved
A ship must have a placard of at least 5 X 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following: "Discharge of Oil Prohibited." The machinery room did not have the required placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 8 September 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 August 2022
Resolved
The official number of the vessel preceded by the abbreviation "NO," must be marked in block-type Arabic numerals not less than three inches in height on some clearly visible interior structural part of the hull. The number must be permanently affixed to the vessel so that alteration, removal, or replacement would be obvious. The vessel ON was not found on any interior part of the hull.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 12 September 2022
Resolution: Image of the ON tack welded to the inside hull plating (engine room) was sent to SSJ.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 November 2021
Resolved
Vessel's 2nd cylinder on the port inboard engine, in the B bank is not firing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2021
Resolution: Marine inspectors witnessed satisfacotry running testing of the port inboard engine and a successful sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 November 2021
Resolved
Propulsion machinery must be suitable in type and design or propulsion requirements of the hull in while it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Port inboard engine's, second cylinder sleeve in the B Bank is broken. Provide tech report or mechanic report to the satisfaction of the attending USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2022
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 30 August 2021
Resolved
Automatic Identification System (AIS) must be maintained in effective operating conditions. The AIS is not broadcasting the following information: a. Official Number Missing; b. Length; c. Beam; d. Draft; e. Antenna distance A-D. The information currently being transmitted by the vessel is not being received at the U.S. Coast Guard Navigation Center Website (www.navcen.uscg.gov). Prove proper operation of the AIS and that the USCG Navigation center received the vessel information particulars within 30 days. 33 CFR 164.46 (d)(2).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2021
Resolved 22 August 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2020
Resolved
Repair/permanently attach ladder in number 2 center void space.
Action required: 705 - Other - as specified
Resolved 13 July 2021
Resolution: Verified ladder permanently attached in 2021 drydock.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 March 2019
Resolved
crop and renew mared wasted areas on port side. From transom fwd 6'x9'3" section from chine to sheer. From sheer down 28" by 26' long and from chine to sheer 6'x66'.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 August 2018
Resolved
IMO: Vsl is broadcasting no IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2019
Resolved 22 February 2019
Resolution: Vessel operator acknowledged the AIS discrepensy and provided proof from the AIS website.
Engineering › Lubricating Oil Service System › Piping
Issued 3 May 2018
Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personal injury. Proper maintenance was not performed as evidenced by failure of the crew to proactively manage observed and logged low lube oil readings for #4 MDE. Crew continued to operate the vessel in an unsafe manner for prolonged daily use from 27APR2018 to 02MAY2018, leading to engine failure. Review maintenance procedures, revise as appropriate, and educate crew. 13199; 46CFR182.01-5
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 May 2018
Resolution: Corrective action was taken to review applicable maintenance procedures and were revised to include immediate reporting. Crew educated.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 3 May 2018
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The #4 MDE experienced an unknown failure causing loss of lube oil, resulting in water intrusion and a large amount of metal shavings in the oil, rendering the engine inoperable. Repair or replace #4 MDE in-kind. 13101; 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 May 2018
Resolution: In-kind engine installed and satisfactory sea trails performed.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 14 December 2017
Resolved
Prove proper operation of #3 MDE
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2018
Resolution: Conducted major overhaul of the #3 Engine. Successful operational test completed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 December 2017
Resolved
Remove oily water from the bilges
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2018
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 28 September 2017
Resolved
At every other inspection all observed unsafe practices must be corrected. Found a total of (04) broken seat backs at port upper deck. 46CFR176.830(a).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 20 October 2017
Resolution: All seats were repaired.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 28 September 2017
Resolved
Fire detection system must be installed in compliance with 46CFR 181.400 thru 181.420. Fire detection system loss its programming and only shows zones. 46CFR174.410(c)(3).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 20 October 2017
Resolution: Panel has been programed to identify locations.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 28 September 2017
Resolved
At every other inspection, all observed unsafe practices must be corrected. Found about 1 foot of oil and water mixture in the engine room bilge. 46CFR176.830(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 20 October 2017
Resolution: Bilges were found at appropiate level and mixtures.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 April 2017
Resolved
Lifejackets for children shall be stowed separately IAW 46CFR180.25-10.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: Children lifejackets were re-stowed separately.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 April 2017
Resolved
Lifejackets containers at upper deck next to the operating station shall be so design as to allow lifejackets to float free IAW 46CFR180.25-10.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: A new FRP storage bin was installed in place and will allow the PFDs to flotate free.
Construction/Loadline › Hull › Bottom Plating
Issued 6 June 2016
Resolved
Guaging report indicated many areas on the bottom plating to be wasted beyond limitations
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 August 2016
Resolution: cropped and renewed areas on bottom plating with 3/8 inch steel plating
Engineering › Reduction Gearing/Clutches › Clutch Plate
Issued 10 March 2016
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2016
Resolved 13 January 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 February 2016
Resolved
REPLACE SPLIT WIRING TO STARTER ON INBOARD STARBOARD ENGINE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 7 March 2016
Resolution: Verified replace split wires to starter on inboard starboard engine.
Fire Fighting › Fire Main › Condition
Issued 29 February 2016
Resolved
REPLACE DAMAGED SECTION OF BILGE/FIRE MAIN LINE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 8 March 2016
Resolution: Verified damage section of bilge/fire main line.
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 February 2016
Resolved
Lazarette: replace bottom section of #1 frame on aft stbd side bulkhead, frame #68, 4th beam crack, crop & renew frame #62/fwd bulkhead stbd side, replace corroded webbing fix hydraulic hose weak port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 29 December 2016
Construction/Loadline › Penetrations › Pipe Flange
Issued 29 February 2016
Resolved
Properly repair leaking piping in the CO2 room.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 31 March 2016
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 29 February 2016
Resolved
Repair/replace torn insulation on stbd engine.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 13 January 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 29 February 2016
Resolved
Install stbd lighting fixture in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 31 March 2016
Electrical › Electric Generation Source (service) › Generator Cable
Issued 29 February 2016
Resolved
Replace welding cable on batteries with marine grade material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 2 May 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 29 January 2016
Resolved
Prove proper operation of starboard inboard main diesel engine prior to carrying passengers or cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2016
Resolved 15 February 2016
Resolution: #3 engine reduction gear was repaired. All parts that were deteriorated due to casualty were replaced.