MAURY USCG vessel records Sign in
← All vessels

SANTA MARIA

SANTA MARIA is a 1990 passenger vessel (inspected). The Coast Guard has recorded 115 inspections since 1990, most recently in November 2025, along with 229 deficiencies — 1 with no resolution recorded — and 6 operational controls.

Records from 1990 to 2025. Most recent: inspection, 5 November 2025.

Built
1990
Last inspected
5 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH4392
350563
Flag
UNITED STATES
367617230
Maury page id
psix-350563

Inspections, by type

…with no type recorded13
Years with a record 33 calendar years (1990–2025)
The 115 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)136.3 ft × 37.5 ft × 11.1 ft
Registered tonnagegross 72 / net 49
ITC dimensions (L × B × D)136.3 ft × 37.5 ft × 11.1 ft
ITC tonnagegross 326 / net 100
BuilderBLOUNT MARINE CORP. · WARREN, RI, UNITED STATES · built 1990
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFAJARDO, PR
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it326 - Convention (Subpart B), Gross Ton
72 - Regulatory (Subpart C or D), Gross Ton
100 - Convention (Subpart B), Net Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH4392MMSI 367617230 · active · compulsorily equipped · granted 29 April 2024, expires 24 April 2034
WDC6942MMSI 367063620 · expired · compulsorily equipped · granted 24 August 2005, cancelled 24 October 2015
WAN9965MMSI not assigned · expired · compulsorily equipped · granted 13 February 1997, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 115

5 November 2025 Internal Structural Exam · Drydock Exam · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8264487
12 August 2025 Annual Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 8207367
19 September 2024 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7999411
16 November 2023 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7824388
6 September 2023 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7786303
8 June 2023 Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7709453
31 January 2023 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7629496
16 December 2022 In-Service Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7624676
22 August 2022 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7536369
16 November 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7352383
30 August 2021 COI Inspection · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7300122
6 July 2021 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7247003
19 August 2020 Deficiency Check · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7037361
15 January 2019 Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6608957
14 November 2018 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6580417
14 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6511378
3 May 2018 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6405078
20 March 2018 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6375524
26 February 2018 Internal Structural Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6362293
14 December 2017 Deficiency Check · Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6325051
28 September 2017 In-Service Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6290793
12 July 2017 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6207101
10 April 2017 In-Service Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6122327
13 January 2017 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6069869
14 October 2016 Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6022875
8 September 2016 Examination of Repairs · Administrative Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6017936
4 August 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5962358
6 June 2016 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5898677
21 March 2016 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5837189
10 March 2016 Administrative Inspection · Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5830906
29 February 2016 Drydock Extension
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5825062
29 January 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5809390
7 November 2015 Damage Survey
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5758910
16 October 2015 Examination of Repairs
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5745752
9 October 2015 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5739311
21 October 2014 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5009205
20 October 2014 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5061627
12 December 2011 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4206606
7 August 2011 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4110382
7 July 2011 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4072848
10 February 2010 Hull Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3678085
15 March 2009 Drydock Extension
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3433599
24 June 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3248996
24 June 2008 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3249406
17 December 2007 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3158603
25 October 2007 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3087206
26 September 2007 In-Service Inspection · Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3158586
20 July 2007 Damage Survey
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3004040
18 June 2007 Deficiency Check · In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3001331
5 April 2007 Deficiency Check · COI Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2902091
22 March 2007 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2892680
15 September 2006 Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2857443
25 August 2006 Load Line/Change of Employment
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2759266
18 May 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2652494
8 November 2005 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2530913
28 October 2005 Drydock Extension
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2524114
27 October 2005 Deficiency Check · Drydock Extension
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2512254
26 August 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2475566
23 June 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2462141
23 May 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2385756
4 March 2005 Annual Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2305718
15 February 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2296786
21 January 2005 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2278806
20 October 2004 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2224904
7 September 2004 In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2189409
22 August 2004 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2172981
14 July 2004 In-Service Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2132878
24 May 2004 In-Service Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2076335
30 December 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2062466
5 November 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1943087
23 October 2003 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1934684
29 April 2003 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1782933
30 January 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1737354
26 December 2002 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1723230
26 December 2002 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1723379
9 September 2002 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1673125
7 March 2002 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1603059
24 April 2000 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1448181
28 January 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1401177
24 January 2000 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 814104
8 November 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 810287
28 October 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 811645
6 October 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 691629
30 September 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1433538
15 July 1999 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1096183
23 June 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1090256
29 April 1999 Re-Inspection · Drydock Extension
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1453605
12 April 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1124180
30 April 1998 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1400772
24 April 1997 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368202
9 April 1997 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1456451
24 October 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 691627
11 September 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 52183
12 January 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1182008
4 January 1996 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1453187
15 February 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 846001
6 January 1995 Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1463146
16 August 1994 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1440844
30 June 1994 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1137950
10 June 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 166591
6 June 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1014856
28 April 1994 Drydock Extension
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1400015
16 September 1993 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 836949
14 August 1993 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1410842
13 July 1993 Excursion Permit
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1154753
27 August 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 953001
13 August 1992 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1250595
9 June 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1268767
11 May 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 956568
7 April 1992 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 960157
2 October 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1248436
24 September 1991 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1245070
15 August 1991 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 939394
26 March 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1232723
17 August 1990 Hull Examination · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1223880

Deficiency record · 229

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2025 Resolved
A fixed-gas fire extinguishing system must be capable to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Main diesel engine number 4 failed to shut-off during the fixed-gas fire system test.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2025
Resolution: A solenoid was found damaged, then replaced and retested. Corrected on the spot 10C.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 August 2025 Resolved
Each hatch exposed to the weather must be watertight. Engine Room cargo deck access hatch was found leaking water into the engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2025
Resolution: Hatch was readjusted, 10c. Corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 12 August 2025 Resolved
Each hatch exposed to the weather must be watertight. Engine Room center main cargo deck access hatch was found leaking water into the engine room. Main engine room access hatch was found not sealing watertight. Engine room is a Co2 protected space.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 August 2025
Resolution: Hatch was readjusted, 10C. Corrected on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 August 2025 No resolution recorded
Exhaust gas must not leak from the piping or any connections. The piping must be properly supported by noncombustible hangers or blocks. Exhaust leaks were identified in several locations on top of the lagging in all 04 main diesel engines, engine room exhaust piping. Once exhaust leaks are corrected, provide a report to the USCG about findings and repairs conducted. CODE &)% to be corrected for next dry dock credit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 August 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The Notifier indicator panel located in the main deck portside was found to have its main cover door not closing properly as its box frame loose, the access key in the lock accessible to passengers, and marked as restricted area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 20 August 2025
Resolution: Readjusted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 12 August 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Coast Guard Light List;(4) Tide tables; and(5) Current tables. Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Vessel is missing updated current and tide tables, and Light List.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 20 August 2025
Resolution: Publications have been updated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 August 2025 Resolved
Connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and, where necessary, fire-resisting properties of the cable. All connecting devices must be suitable for copper stranded conductors. Correct dead-end wires found in under the operating station, and in the fire detection panel main deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 August 2025
Resolved 20 August 2025
Resolution: All dead-end wires were secured.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 16 November 2023 Resolved
Explosion-proof equipment and intrinsically safe systems must meet the requirements of 111.105 in subchapter J of this chapter. Aft stbd deck light cover is broken. Replace or repair t manufacturer specifications. Hazardous cargo operations are restricted to daylight operations only. Crew must electrically isolate/tag out deck lighting prior to loading hazardous cargo and log in the ship's log. 46 CFR 183.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2023
Resolved 16 November 2023
Resolution: Vessel rep submitted images of replaced deck lighting fixture.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 16 November 2023 Resolved
Gauges to indicate revolutions per minute (RPM) must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. #2 port MDE RPM gauge at the helm is not providing an accurate reading. Repair or replace. 46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2023
Resolved 17 November 2023
Resolution: Vessel rep submitted video of rpm gauge functioning properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 June 2023 Resolved
In systems were flexible hoses are permitted to be clamped double hose clamping is required. Port and starboard generator raw water flexible hoses have one clamp installed. 46 CFR 182.410(d)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 16 June 2023
Resolution: Hose clamps were properly installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 13 June 2023 Resolved
All exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: “EMERGENCY EXIT, KEEP CLEAR”. Engine room starboard emergency escape hatch is not labeled. 46 CFR 185.606
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 16 June 2023
Resolution: Engine room starboard emergency escape hatch was properly labeled.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 June 2023 Resolved
The cognizant OCMI may require that a vessel undergo additional test deemed reasonable and necessary to determine that the vessel is suitable for the service in which they are employed. Port void forward of fuel tank hull plating above and below longitudinal beam in way of ladder is required to be gauged for thickness. 46 CFR 176.840 Code 705 By next dry dock.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 July 2023
Resolved 24 October 2023
Resolution: gauged as required
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 8 June 2023 Resolved
A hatch exposed to the weather must be watertight. Engine room starboard emergency escape hatch “knife edge” has been covered with a rubber channel and silicone. Return “knife edge” to original metal design. 46 CFR 179.360 Code 705 by next dry dock
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 July 2023
Resolved 1 November 2023
Resolution: Adjusted dogs and conducted satisfactory hose test with firemain
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 August 2022 Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Stability letter was not posted at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 8 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 22 August 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices and other hazardous situations must be corrected. During the MOB drill, MI's observed free swinging doors at the bulwark rescue gate. When the vessel crew prepare to rescue a person in the water (PIW), a rescue ladder is attached to the bulwark and the bulwark rescue gate is opened. While the vessel is being maneuvered to recover a PIW the rescue gate doors swing freely. This presents a hazard to the crew and to the person being recovered. Bulwark rescue gate doors must have a means of latching them open to minimize potential injuries.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 8 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2022 Resolved
A ship must have a placard of at least 5 X 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station, stating the following: "Discharge of Oil Prohibited." The machinery room did not have the required placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 8 September 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 22 August 2022 Resolved
The official number of the vessel preceded by the abbreviation "NO," must be marked in block-type Arabic numerals not less than three inches in height on some clearly visible interior structural part of the hull. The number must be permanently affixed to the vessel so that alteration, removal, or replacement would be obvious. The vessel ON was not found on any interior part of the hull.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2022
Resolved 12 September 2022
Resolution: Image of the ON tack welded to the inside hull plating (engine room) was sent to SSJ.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 November 2021 Resolved
Vessel's 2nd cylinder on the port inboard engine, in the B bank is not firing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 December 2021
Resolution: Marine inspectors witnessed satisfacotry running testing of the port inboard engine and a successful sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 November 2021 Resolved
Propulsion machinery must be suitable in type and design or propulsion requirements of the hull in while it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Port inboard engine's, second cylinder sleeve in the B Bank is broken. Provide tech report or mechanic report to the satisfaction of the attending USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2022
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 30 August 2021 Resolved
Automatic Identification System (AIS) must be maintained in effective operating conditions. The AIS is not broadcasting the following information: a. Official Number Missing; b. Length; c. Beam; d. Draft; e. Antenna distance A-D. The information currently being transmitted by the vessel is not being received at the U.S. Coast Guard Navigation Center Website (www.navcen.uscg.gov). Prove proper operation of the AIS and that the USCG Navigation center received the vessel information particulars within 30 days. 33 CFR 164.46 (d)(2).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2021
Resolved 22 August 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2020 Resolved
Repair/permanently attach ladder in number 2 center void space.
Action required: 705 - Other - as specified
Resolved 13 July 2021
Resolution: Verified ladder permanently attached in 2021 drydock.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 March 2019 Resolved
crop and renew mared wasted areas on port side. From transom fwd 6'x9'3" section from chine to sheer. From sheer down 28" by 26' long and from chine to sheer 6'x66'.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 August 2020
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 August 2018 Resolved
IMO: Vsl is broadcasting no IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 January 2019
Resolved 22 February 2019
Resolution: Vessel operator acknowledged the AIS discrepensy and provided proof from the AIS website.
Engineering › Lubricating Oil Service System › Piping
Issued 3 May 2018 Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personal injury. Proper maintenance was not performed as evidenced by failure of the crew to proactively manage observed and logged low lube oil readings for #4 MDE. Crew continued to operate the vessel in an unsafe manner for prolonged daily use from 27APR2018 to 02MAY2018, leading to engine failure. Review maintenance procedures, revise as appropriate, and educate crew. 13199; 46CFR182.01-5
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 May 2018
Resolution: Corrective action was taken to review applicable maintenance procedures and were revised to include immediate reporting. Crew educated.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 3 May 2018 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. The #4 MDE experienced an unknown failure causing loss of lube oil, resulting in water intrusion and a large amount of metal shavings in the oil, rendering the engine inoperable. Repair or replace #4 MDE in-kind. 13101; 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 4 May 2018
Resolution: In-kind engine installed and satisfactory sea trails performed.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (electric)
Issued 14 December 2017 Resolved
Prove proper operation of #3 MDE
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2018
Resolution: Conducted major overhaul of the #3 Engine. Successful operational test completed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 December 2017 Resolved
Remove oily water from the bilges
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2018
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 28 September 2017 Resolved
At every other inspection all observed unsafe practices must be corrected. Found a total of (04) broken seat backs at port upper deck. 46CFR176.830(a).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 20 October 2017
Resolution: All seats were repaired.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 28 September 2017 Resolved
Fire detection system must be installed in compliance with 46CFR 181.400 thru 181.420. Fire detection system loss its programming and only shows zones. 46CFR174.410(c)(3).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 20 October 2017
Resolution: Panel has been programed to identify locations.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 28 September 2017 Resolved
At every other inspection, all observed unsafe practices must be corrected. Found about 1 foot of oil and water mixture in the engine room bilge. 46CFR176.830(a).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2017
Resolved 20 October 2017
Resolution: Bilges were found at appropiate level and mixtures.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 April 2017 Resolved
Lifejackets for children shall be stowed separately IAW 46CFR180.25-10.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: Children lifejackets were re-stowed separately.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 April 2017 Resolved
Lifejackets containers at upper deck next to the operating station shall be so design as to allow lifejackets to float free IAW 46CFR180.25-10.
Action required: 705 - Other - as specified
Due 21 April 2017
Resolved 21 April 2017
Resolution: A new FRP storage bin was installed in place and will allow the PFDs to flotate free.
Construction/Loadline › Hull › Bottom Plating
Issued 6 June 2016 Resolved
Guaging report indicated many areas on the bottom plating to be wasted beyond limitations
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 August 2016
Resolution: cropped and renewed areas on bottom plating with 3/8 inch steel plating
Engineering › Reduction Gearing/Clutches › Clutch Plate
Issued 10 March 2016 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2016
Resolved 13 January 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 February 2016 Resolved
REPLACE SPLIT WIRING TO STARTER ON INBOARD STARBOARD ENGINE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 7 March 2016
Resolution: Verified replace split wires to starter on inboard starboard engine.
Fire Fighting › Fire Main › Condition
Issued 29 February 2016 Resolved
REPLACE DAMAGED SECTION OF BILGE/FIRE MAIN LINE
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2016
Resolved 8 March 2016
Resolution: Verified damage section of bilge/fire main line.
Construction/Loadline › Hull › Longitudinal Frame
Issued 29 February 2016 Resolved
Lazarette: replace bottom section of #1 frame on aft stbd side bulkhead, frame #68, 4th beam crack, crop & renew frame #62/fwd bulkhead stbd side, replace corroded webbing fix hydraulic hose weak port side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 29 December 2016
Construction/Loadline › Penetrations › Pipe Flange
Issued 29 February 2016 Resolved
Properly repair leaking piping in the CO2 room.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 31 March 2016
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 29 February 2016 Resolved
Repair/replace torn insulation on stbd engine.
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 13 January 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 29 February 2016 Resolved
Install stbd lighting fixture in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 31 March 2016
Electrical › Electric Generation Source (service) › Generator Cable
Issued 29 February 2016 Resolved
Replace welding cable on batteries with marine grade material.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 2 May 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 29 January 2016 Resolved
Prove proper operation of starboard inboard main diesel engine prior to carrying passengers or cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 January 2016
Resolved 15 February 2016
Resolution: #3 engine reduction gear was repaired. All parts that were deteriorated due to casualty were replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 16 October 2015 Resolved
Prove proper operation of No. 3 main engine prior to carrying passengers or cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 October 2015
Resolved 19 October 2015
Resolution: Conducted succesfull sea-trials.
Communications › Alarms/Indicators › Collision Alarm
Issued 9 October 2015 Resolved
Provide audible alarm at the operating station for bilge high level alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2015
Resolved 19 October 2015
Resolution: Operationally tested the bilge alarm.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 9 October 2015 Resolved
Rearrange Carbon Dioxide hose to prevent damage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2015
Resolved 19 October 2015
Resolution: Verified the arrangement of the hose.
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 9 October 2015 Resolved
Repair exhaust leak on the port inboard engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2015
Resolved 19 October 2015
Resolution: Verified the repairs completed on the exhaust of the port inboard engine.
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 21 October 2014 Resolved
Renew STBD outboard intermediate shaft to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2014
Resolved 20 January 2015
Resolution: Vessel replace STBD outboard irtemidiate shaft.
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 21 October 2014 Resolved
Conduct a sea trial in the presence of CG Marine Inspectors.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2014
Resolved 20 January 2015
Resolution: Vessel conducted successful sea trials.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 10 February 2010 Resolved
Provide gas free certificate for any welding within 25' of fuel tank
Action required: 705 - Other - as specified
Resolved 5 February 2014
Resolution: Deficiency closed, vessel has been out of service and need to undergo COI Inspection and Drydock credit. Currently vessel is not being repaired and no work is being performed according with vessel operator.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 24 June 2008 Resolved
Vessel has 102 Adult life Jackets on board but limits it's seating to 80 passengers. passenger count is reduced until 153 life jackets and 16 child jackets are verified on board vessel.
Action required: 705 - Other - as specified
Resolved 30 June 2008
Resolution: Deficiency closed, vessel is out of service and need to undergo a COI Inspection and Drydock credit.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 17 December 2007 Resolved
1. Segregate adult from child lifejackets throughout vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2007
Resolution: Done.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 December 2007 Resolved
2. Post COI pages in passenger area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2007
Resolution: Done.
Engineering › Bilge Water Management System › Manifold
Issued 17 December 2007 Resolved
3. Provide diagram or identify all bilge and ballast valves in engine room manifold.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2007
Resolution: Done.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 December 2007 Resolved
4. Remove adrift battery in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2007
Resolution: Done.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 December 2007 Resolved
5. Reinstall missing light fixtures covers in engine room lights.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2007
Resolution: Done.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 17 December 2007 Resolved
6. Renew life floats retro tape.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2007
Resolution: Done.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 17 December 2007 Resolved
7. Repair engines #2 and # 4 kill switch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2007
Resolution: Done.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 December 2007 Resolved
8. Remove all trash under pilothouse bench by aft winch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2007
Resolution: Done.
Engineering › Steering Gear System › Ram
Issued 25 October 2007 Resolved
Repair Steering System excessive leakage
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM put new backing seals in both rams.Tested sat.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 October 2007 Resolved
Remove excess Hydralic Fluid from Aft steering compartment
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM rented a vacuum truck and cleaned steering compartment. SAT
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 October 2007 Resolved
Remove twelve inches of excess oil from Engine Room Bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM rented Vacuum truck and cleaned bilge. Sat.
Construction/Loadline › Structures › Scuttle
Issued 25 October 2007 Resolved
Make proper repairs to Steering Compartment access scuttle
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM repaired broken hardware and replaced gasket.SAT.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 25 October 2007 Resolved
Repair access to Starboard side upper deck life jacket locker.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM repaired box for easy access.SAT
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 25 October 2007 Resolved
Verify total quantity of Lifejackets on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: Inspectors did complete count of all life jackets.SAT
Lifesaving › Lifefloat › Float Free
Issued 25 October 2007 Resolved
make port side lifefloat in a float free arangment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM installed new float light and made float free.SAT
Lifesaving › Buoyant Apparatus › Serviceable
Issued 25 October 2007 Resolved
replace missing two oars from port side buoyant apparatus.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM installed new oars with proper markings. SAT
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 25 October 2007 Resolved
repair oil leaks on turbo chargers Starboard side MDE.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM installed new mating seals on turbos.SAT
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 October 2007 Resolved
Seperate child lifejackets from adult lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM marked childs life jackets and provided them lower stoage rack below Adults. SAT
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 25 October 2007 Resolved
Label lifejacket storage locker.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM properly labeled life jacket stowage. SAT
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 October 2007 Resolved
remove excess gear from lifejacket locker.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM removed extra trash and gear from stowage space. SAT
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 October 2007 Resolved
reinstall seperated meter from engine room electrical distribution panel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM installed new meter in panel.SAT
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 October 2007 Resolved
Remove wing nuts from all batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM replaced all wingnuts from batteries with proper hardware.SAT
Electrical › Electrical Distribution System (service) › Panelboard
Issued 25 October 2007 Resolved
label panel board aft bulkhead in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM labeled all breaker panels.SAT
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2007 Resolved
Remove all deadend wires from engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2007
Resolution: ATM removed noticeable dead end wires or properly terminated them.SAT
Electrical › Lighting (service) › Lighting Fixture
Issued 26 September 2007 Resolved
1. Repair inoperative searchlight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2007
Resolution: Done
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 26 September 2007 Resolved
2. Reinstall missing portable lights
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2007
Resolution: Done
Navigation › Piloting/Steering › Marine Charts
Issued 26 September 2007 Resolved
3. Provide missing navigational chart.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 December 2007
Resolution: Done.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 September 2007 Resolved
4. Passenger count not to exceed 67 passengers untill missing seating and A/C repaired.
Action required: 705 - Other - as specified
Due 2 October 2008
Resolved 17 December 2007
Resolution: Done.
Accommodation/Occupational Safety › Ventilation › General
Issued 26 September 2007 Resolved
5. Repair engineroom ventilation blower.
Action required: 705 - Other - as specified
Due 2 October 2007
Resolved 17 December 2007
Resolution: Done
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 September 2007 Resolved
7. Renew both pilothouse doors and install missing lock.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 17 December 2007
Resolution: Done
Construction/Loadline › Penetrations › Gasket
Issued 26 September 2007 Resolved
6. Reseal all leaking windows and repair broken window glass
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 17 December 2007
Resolution: Done
Accommodation/Occupational Safety › Ventilation › General
Issued 26 September 2007 Resolved
8. Provide missing ventilation fans in both bathrooms.
Action required: 705 - Other - as specified
Due 2 October 2007
Resolved 17 December 2007
Resolution: Done.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 18 June 2007 Resolved
Provide new anchor line with +450ft of line.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 18 June 2007 Resolved
Repair #2 engine start button. (Engine will not start from bridge).
Due 19 June 2007
Resolved 29 June 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 18 June 2007 Resolved
Provide Inoperational engineroom ventilation blower.
Due 19 June 2007
Resolved 29 June 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 18 June 2007 Resolved
Provide dimmer or red light forr navigation compas.
Due 19 June 2007
Resolved 29 June 2007
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 April 2007 Resolved
Provide missing training log book.
Due 5 May 2007
Resolved 5 May 2007
Navigation › Collision/Grounding Avoidance › Relative Motion Plotting Equipment
Issued 5 April 2007 Resolved
Provide navigation charts, light list, tidal current tables & plotting equipment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2007
Construction/Loadline › Penetrations › Gasket
Issued 5 April 2007 Resolved
Seal all holes & leaks in pilothouse windows and bridge.
Due 5 May 2007
Resolved 29 June 2007
Lifesaving › Lifefloat › Retroreflective Material
Issued 5 April 2007 Resolved
Provide retroreflective tape for lifeboats and provide 3 missing oars.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 5 April 2007 Resolved
Repair stbd side decklight topside next to bridge. Bracket corroded.
Due 5 May 2007
Resolved 29 June 2007
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 5 April 2007 Resolved
Provide missing bow hook onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2007
Construction/Loadline › Structures › Deck Plating
Issued 28 October 2005 Resolved
Repair new perforations found on main ro-ro deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Construction/Loadline › Structures › Machinery Space Opening
Issued 28 October 2005 Resolved
Repair perforations found on main deck vent ducts leading to the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Construction/Loadline › Structures › Deck Plating
Issued 28 October 2005 Resolved
Repair and replace missing and wasted deck plates found in engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 28 October 2005 Resolved
Replace electrical piping located at winch for main deck stern ramp.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Engineering › Diesel Engine (propulsion-direct drive) › Pump, Positive Displacement
Issued 28 October 2005 Resolved
Provide operational lights on all pilothouse gauges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Engineering › Lubricating Oil Service System › Gauge
Issued 28 October 2005 Resolved
Provide operational alarm for all engines in pilothouse.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 October 2005 Resolved
Renew all corroded and missing deck plates from engineroom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 October 2005 Resolved
Provide electrical box for exposed wires in loudhailer.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 October 2005 Resolved
Restencil lifering on board with vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Accommodation/Occupational Safety › Ventilation › General
Issued 27 October 2005 Resolved
Remove and reseal all windows and replace #1 broken window in stbd door at next drydock.
Action required: 705 - Other - as specified
Resolved 16 March 2007
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 October 2005 Resolved
Repair all inoperative emergency lighting.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 October 2005 Resolved
Reinstall cover guard on #1 ship service generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 October 2005 Resolved
Remove all old batteries from engineroom.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 27 October 2005 Resolved
Restencil all emergency shutdowns and vents.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 27 October 2005 Resolved
Renew missing sewage discharge valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 October 2005 Resolved
Renew electrical pipe on aft receptacle with exposed wires
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2005
Communications › Internal Communications System › Voice Tube
Issued 26 August 2005 Resolved
Repair inoperative Public anouncement system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2005
Engineering › Steering Gear System › Rudder Bearing
Issued 26 August 2005 Resolved
Repair excessive oil leaks on all main diesel engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2005
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 26 August 2005 Resolved
Correct exhaust leak in aft steering space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2005
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 26 August 2005 Resolved
Correct excessive oil leaks on all main diesel engines.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 September 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 26 August 2005 Resolved
Repair leak on seachest stop valve on stbd side fwd.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2005
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 26 August 2005 Resolved
Reinstall generator strainer cover.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2005
Engineering › Bilge Water Management System › Piping
Issued 26 August 2005 Resolved
Repair soft patch on bilge piping system manifold.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2005
Engineering › Fuel Oil Service System › Filter
Issued 26 August 2005 Resolved
Reinstall fuel filter flame protection plates.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2005
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 26 August 2005 Resolved
Correct #1 maiin diesel engine fuel oil leak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 26 August 2005 Resolved
Repair inoperative VHF radio.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2005
Engineering › Freshwater System (jacketwater cooling) › Charging Tank
Issued 14 August 2005 Resolved
Provide sealed cooling system for service generator.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2005
Electrical › Electric Supply System (service) › Battery Charger
Issued 14 August 2005 Resolved
Provide operational battery charging system as original design of vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2005
Construction/Loadline › Hull › Hull Plating
Issued 14 August 2005 Resolved
Repair corroded engine room hatch during next dry-dock, meanwhile no heavy trucks over hatch area until renewed.
Action required: 705 - Other - as specified
Resolved 1 September 2005
Engineering › Steering Gear System › Rudder
Issued 14 August 2005 Resolved
Seal leaking rudders in lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 14 August 2005 Resolved
Provide operational engineroom lighting.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2005
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 10 June 2005 Resolved
Repair a/c in port lower passenger area COI downgrade to 80 passengers.
Action required: 705 - Other - as specified
Due 23 June 2005
Resolved 1 September 2005
Construction/Loadline › Hull › Hull Plating
Issued 10 June 2005 Resolved
Provide repair proposal for port engineroom engine deck cover current one is cracked and leaking water on top of engine.
Action required: 705 - Other - as specified
Due 23 June 2005
Resolved 1 September 2005
Engineering › Steering Gear System › Rudder Stock
Issued 4 March 2005 Resolved
Clean all soot and excess trash in lazarette.
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 11 March 2005
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 4 March 2005 Resolved
Provide missing insulation panels in bathroom.
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 11 March 2005
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 4 March 2005 Resolved
Renew missing vehicle tie down point.
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 11 March 2005
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 4 March 2005 Resolved
Renew missing A/C grating cover in pasenger area.
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 11 March 2005
Construction/Loadline › Hull › Hull Plating
Issued 4 March 2005 Resolved
Provide a Ultrasonic test for several areas designated by CG inspector at next drydock.
Action required: 705 - Other - as specified
Due 30 August 2005
Resolved 16 March 2007
Construction/Loadline › Structures › Air Pipe
Issued 4 March 2005 Resolved
PROVIDE REPAIR PROPOSAL FOR BOTH AIR INTAKE STRUCTURES.
Action required: 705 - Other - as specified
Due 31 August 2005
Resolved 1 September 2005
Construction/Loadline › Structures › Superstructure
Issued 22 February 2005 Resolved
Submit to CG inspector repair proposal for rear ramp cargo door/ Current one is severely corroded and is a safety hazard for passengers/ cargo.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2005
Communications › Audible Communications › SPD (Other)
Issued 22 February 2005 Resolved
Repair vessel P.A. system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 March 2005
Fire Fighting › Fire Main › Valves
Issued 21 January 2005 Resolved
RENEW BROKEN FIRE STATION VALVE.
Action required: 705 - Other - as specified
Due 4 March 2005
Resolved 4 March 2005
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 21 January 2005 Resolved
PROVIDE OPERATIONAL LIGHT ON PORT BUOYANT APPARATUS.
Action required: 705 - Other - as specified
Due 4 March 2005
Resolved 4 March 2005
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 21 January 2005 Resolved
MARK EXPIRATION DATE ON ALL HYDROSTATIC RELEASES.
Action required: 705 - Other - as specified
Due 4 March 2005
Resolved 4 March 2005
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 21 January 2005 Resolved
RENEW BROKEN ENGINEROOM ELECTRICAL PANEL 240-30
Action required: 705 - Other - as specified
Due 4 March 2005
Resolved 4 March 2005
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 January 2005 Resolved
REPAIR ALL DEFECTIVE FLUORESCENT LIGHTS IN PASSENGER AREA AND ENGINEROOM LIGHTS.
Action required: 705 - Other - as specified
Due 25 January 2005
Resolved 4 March 2005
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 21 January 2005 Resolved
REPAIR WIPER IN PILOTHOUSE.
Action required: 705 - Other - as specified
Due 25 January 2005
Resolved 4 March 2005
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 January 2005 Resolved
CAP OFF END OF MISSING MUFFLER AREA OR RENEW MUFFLER.
Action required: 705 - Other - as specified
Due 4 March 2005
Resolved 4 March 2005
Engineering › Bilge Water Management System › Not Operational
Issued 21 January 2005 Resolved
REMOVE ALL OILY WATER FROM BILGE.
Action required: 705 - Other - as specified
Due 4 March 2005
Resolved 4 March 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 21 January 2005 Resolved
PROVIDE NEW B5 EXTINGUISHER ON DECK CURRENT ONE RUSTED EXTREMELY
Due 4 March 2005
Resolved 4 March 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Valve Actuating Gear
Issued 20 October 2004 Resolved
Change cable and adjust control # 2 and #3 on pilothouse.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2004
Resolved 20 October 2004
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 20 October 2004 Resolved
Repair inoperative rudder angle indicator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 October 2004
Resolved 20 October 2004
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 20 October 2004 Resolved
REPAIR A/C SYSTEM IN PILOTHOUSE AND PASSENGER AREA . COI DOWNGRADED TO 18 PASSENGERS ONLY.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 January 2005
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 7 September 2004 Resolved
Downgraded COI to 46 passengers due to inoperational A/C system vessel has sealed windows. Untill problem fixed.
Action required: 705 - Other - as specified
Resolved 20 January 2005
Navigation › Piloting/Steering › Swing Meter
Issued 6 August 2004 Resolved
PROVIDE OPERATIONAL RUDDER ANGLE INDICATOR.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2004
Fire Fighting › Fire Hydrants › Condition
Issued 6 August 2004 Resolved
PROVIDE OPERATIONAL STBD FIRE HYDRANT VALVE (CURRENT ON OOC).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2004
Deck/Cargo › Cargo Stowage › General
Issued 6 August 2004 Resolved
RENEW ALL HARDWARE IN CABLES FOR HOLDING MAST.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2004
Construction/Loadline › Penetrations › Gasket
Issued 6 August 2004 Resolved
REPLACE MISSING WINDOWS AND SEAL ALL LEAKING WINDOWS 8 TOTAL
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 11 March 2005
Engineering › Bilge Water Management System › Not Installed
Issued 14 July 2004 Resolved
Clean all excess oil in the bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2004
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 14 July 2004 Resolved
Install all missing air filters on turbochargers 8 total.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2004
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 14 July 2004 Resolved
Renew faded lifejacket donning placard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2004
Resolved 14 July 2004
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 14 July 2004 Resolved
Repair A/C unit in passenger compartment potside. Passenger count downgraded to 91 passengers only.
Action required: 705 - Other - as specified
Due 24 July 2004
Resolved 3 August 2004
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 14 July 2004 Resolved
Provide adecuate missing seating for 32 passengers in area established with vessel representative as per CFR 46.177.820
Action required: 705 - Other - as specified
Resolved 16 March 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 14 July 2004 Resolved
Repair passenger space lighting in fwd lower section and engineroom.
Action required: 705 - Other - as specified
Due 24 July 2004
Resolved 3 August 2004
Engineering › Diesel Engine (auxiliary) › Charge Air Cooling
Issued 14 July 2004 Resolved
Install missing engineroom ventilation blower.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 September 2004
Resolved 2 September 2004
Engineering › Freshwater Generation System › Pump
Issued 14 July 2004 Resolved
Repair inoperative potable water system corect prior to loading passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 July 2004
Navigation › Piloting/Steering › Compass Deviation Table
Issued 14 July 2004 Resolved
Repair compass light.
Due 8 August 2004
Resolved 3 August 2004
Navigation › Collision/Grounding Avoidance › Radar
Issued 14 July 2004 Resolved
Repair inoperational radar.
Due 8 August 2004
Resolved 4 August 2004
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 14 July 2004 Resolved
Provide operational rpm gauges and engine alarms
Due 8 August 2004
Resolved 17 August 2004
Engineering › Diesel Engine (propulsion-direct drive) › Silencer (exhaust)
Issued 14 July 2004 Resolved
REPAIR ALL EXHAUST LEAKS IN STEERING LAZARETTE AND CLEAN AREA.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2004
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 May 2004 Resolved
REPLACE MISSING BATTERIES IN #2 BATTERY BANK.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 July 2004
Resolved 7 July 2004
Engineering › Bilge Water Management System › Not Installed
Issued 24 May 2004 Resolved
CLEAN ALL ADRIFT ITEMS IN ENGINEROOM BILGE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2004
Resolved 7 July 2004
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 May 2004 Resolved
REPAIR FIXED EMERGENCY LIGHTS PORT AND STARBOARD SIDE IN PASSENGER CABIN.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 May 2004
Resolved 3 August 2004
Engineering › Diesel Engine (propulsion-electric)
Issued 23 October 2003 Resolved
Repair Fuel Oil leak on the Port Service Generator. Prior to the Carriage of passnegers LEGACY COMPONENT DESC: Fuel Lines
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Electrical › Electrical Distribution System (service)
Issued 23 October 2003 Resolved
Repair and verify proper operation of the generator switchboard and all gauges and indicators. Prior to the carriage of passengers. LEGACY COMPONENT DESC: Switchboard
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Accommodation/Occupational Safety › Ventilation
Issued 23 October 2003 Resolved
Remove unguarded fan from engine room while the vessel is underway. LEGACY COMPONENT DESC: Fan
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 23 October 2003 Resolved
Install di-electric mat on deck under switchboard. Prior to the carriage of passengers LEGACY COMPONENT DESC: Di-electric mat
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Lifesaving › Lifejacket/PFD (General)
Issued 23 October 2003 Resolved
Secure upper deck lifejacket lockers. Prior to the carriage of passengers. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Construction/Loadline › Structures
Issued 23 October 2003 Resolved
Re-Install and verify proper securing of starboard engine room deck scuttle. Prior to the carriage of passengers LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Communications › Audible Communications
Issued 23 October 2003 Resolved
Repair forward public address speaker wire. Prior to the carriage of passengers. LEGACY COMPONENT DESC: Public Address System
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Electrical › Electrical Distribution System (service)
Issued 23 October 2003 Resolved
Label passenger compartment breaker boxes with proper idnetification. Prior to the carriage of passengers. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Electrical › Electric Supply System (service)
Issued 23 October 2003 Resolved
Demonstrate proper operation of the 12 volt DC Battery Charger in pilot house. Prior to the carriage of passengers. LEGACY COMPONENT DESC: Battery Charger
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Electrical › Lighting (emergency)
Issued 23 October 2003 Resolved
Install emergency lighting and demonstrate proper operation in the lower passenger compartment includeing the exisiting "EXIT" signs. Prior to the carriage of passengers. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 October 2003 Resolved
Prior to operation between the hours of sunset to sunrise and in restricted visibility. Replace the port and starboard navigation light lenses and verify the shield emits the arch of visibility to 112.5 degrees abaft of beam. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 July 2004
Navigation › Piloting/Steering › Swing Meter
Issued 23 October 2003 Resolved
Repair the rudder angle indicator. LEGACY COMPONENT DESC: Rudder angle indicator
Condition: Improper/Lack of Maintenance
Due 25 November 2003
Resolved 7 July 2004
Construction/Loadline › Hull
Issued 29 April 2003 Resolved
Crop and Re-new Port side aft rudder post support. LEGACY COMPONENT DESC: Strut/Cross Tie
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2003
Construction/Loadline › Structures
Issued 29 April 2003 Resolved
Renew wasted Void Vent, port side aft. LEGACY COMPONENT DESC: Void Vent
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2003
Construction/Loadline › Structures
Issued 29 April 2003 Resolved
renew engine space center deck access cover LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2003
Construction/Loadline › Structures
Issued 29 April 2003 Resolved
Renew all void and compartment access covers LEGACY COMPONENT DESC: Manhole
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2003
Resolution: cancelled
Construction/Loadline › Hull
Issued 29 April 2003 Resolved
Gauge lower section below weld on transverse bulkhead between void #3 and engine space. Provide results to the attending marine inspector or renew the bulkhead. LEGACY COMPONENT DESC: Transverse bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 May 2003
Construction/Loadline › Structures
Issued 29 April 2003 Resolved
Renew or block off the sluice valve pipe from engine space to void #3. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2003
Construction/Loadline › Structures
Issued 29 April 2003 Resolved
Remove all interferences in forward passenger deck. Inspect, crop to new metal, and renew the wasted deck plate in the passenger space. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2003
Construction/Loadline › Structures
Issued 29 April 2003 Resolved
Remove the false overhead in the forward passenger compartment: inspect, crop to new metal and renew the deck and verify the continuity of the deck support structure welds. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2003
Construction/Loadline › Hull
Issued 29 April 2003 Resolved
Crop and renew the forward deck cleat starboard side. LEGACY COMPONENT DESC: cleat
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 November 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 29 April 2003 Resolved
Replace or repair all broken seats in the forward passenger accomodation LEGACY COMPONENT DESC: Passenger seating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2003
Construction/Loadline › Hull
Issued 29 April 2003 Resolved
Audio gauge forepeak keel section from the aft bulkhead forward to the ladder 2 feet out form the keel port and starboard. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2003
Construction/Loadline › Hull
Issued 29 April 2003 Resolved
Audio gauge the underwater hull fom the forward engine room bulkhead aft to the stern. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2003
Construction/Loadline › Hull › Keel
Issued 29 April 2003 Resolved
clean all bilges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 July 2004
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 26 December 2002 Resolved
Repair or replace forward passenger compartment seating aft section port side. The maximum passenger count is reduced by three (3) to not more than 46 passengers until this dieficiency is cleared.
Action required: 705 - Other - as specified
Due 26 January 2003
Resolved 24 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 26 December 2002 Resolved
Replace the cracked glass on the port side door to the forward passenger compartment.
Action required: 705 - Other - as specified
Due 26 January 2003
Resolved 24 October 2003
Electrical › Lighting (service)
Issued 26 December 2002 Resolved
Inspect, install, replace as necessary all light fixtures, globes, and guards as required in the engine space. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2003
Resolved 29 January 2003
Engineering › Sea-water System (primary cooling)
Issued 26 December 2002 Resolved
Remove, clean, repair or replace as necessary the port generator sea strainer. LEGACY COMPONENT DESC: Sea Chest
Action required: 705 - Other - as specified
Due 26 January 2003
Resolved 24 October 2003
Documentation › Markings/Placards
Issued 26 December 2002 Resolved
Properly label the engine room fuel emergency shut off boxes with the appropriate operating instuctions.
Action required: 705 - Other - as specified
Due 26 December 2002
Resolved 24 October 2003
Fire Fighting › Combustible Materials
Issued 26 December 2002 Resolved
Remove all combustibles from engine room and forward pump room. The bilges and overall condition of the vessel was extremely dirty and unkept.
Action required: 705 - Other - as specified
Due 26 January 2003
Resolved 29 January 2003
Engineering › Bilge Water Management System
Issued 26 December 2002 Resolved
Repair or replace the portable bilge pump found under the deck plates in the engine room LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 5 November 2003
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 26 December 2002 Resolved
Properly secure the main deck Type V extinguisher.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 7 July 2004
Engineering › Diesel Engine (auxiliary)
Issued 9 September 2002 Resolved
Rreceived a request to remove 1 of the 2 ship generators from the vessel for overhaul. Under current regulations the vessel may continue to operate. When the ship service generator has been reinstalled on the vessel a Marine Inspector must witness its proper intallation and operation. LEGACY COMPONENT DESC: Overhaul
Due 23 September 2002
Resolved 6 November 2002
Resolution: Removed after reciept of faxed statement form [name withheld]
Fire Fighting › Miscellaneous Items
Issued 25 February 2002 Resolved
Provide a fix axe holder and properly label for crew recognition LEGACY COMPONENT DESC: Fire Axe
Condition: Improper/Lack of Maintenance
Due 25 March 2002
Resolved 1 March 2002
Resolution: Received statement from administrator that req 1 has been cleared
Lifesaving › Lifejacket/PFD (General)
Issued 25 February 2002 Resolved
Properly label all lifejackets storage with accurate number of lifejackets and size (adult/child); adult lifejackets must be separate from child size. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 25 March 2002
Resolved 1 March 2002
Resolution: Received statement from vessel admnistrator that req 2 has been cleared.
Lifesaving › Lifejacket/PFD (General)
Issued 25 February 2002 Resolved
Place lifejackets donning placards on the second desck (passenger accommodations) for passenger review. LEGACY COMPONENT DESC: Donning Placards
Condition: Unknown
Due 25 March 2002
Resolved 1 March 2002
Resolution: Received statement from vessel administrator that req 3 has been cleaed/corrected.
Construction/Loadline › Hull
Issued 25 February 2002 Resolved
Provide repair proposal for damage and corrosion found on deck plating, loss of plate thickness due to corrosion under AC units. See narative for details Activity # 1603059. LEGACY COMPONENT DESC: Plates on cargo deck and passenger accommodation
Condition: Unknown
Due 15 March 2002
Resolved 16 May 2002
Unknown
Issued 30 September 1999 Resolved
Address and take proper action on outstanding eleven (11) deficiency items noted previously by SJPMS (MI99013556) on 29APR99 with a compliance date of29MAY99.
Condition: Unknown
Due 30 September 1999
Resolved 7 October 1999
Construction/Loadline
Issued 30 September 1999 Resolved
Monitor the bilge condition every hour and make entry into vessel's official logbook of the same (per CID).
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Engineering
Issued 29 April 1999 Resolved
Prior to 29MAY99 provide drip pans for fuel filters located at stb side generator or correct minor leak noted on subject filters.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Documentation
Issued 29 April 1999 Resolved
Prior to 29MAY99 properly post emergency instructions at a place available to the vessel master (bridge)
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Electrical
Issued 29 April 1999 Resolved
Prior to 29MAY99, replace battery chargers electrical wires for port and stb battery banks (noted missing protective cover and unauthorized connection-different cable sizes).
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 29 April 1999 Resolved
Prior to 29MAY99 replace section of rubber bilge piping located fwd of the inboard port side engine (engine #2). Metal piping was corroded and was replaced by rubber hose.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Documentation
Issued 29 April 1999 Resolved
Prior to 29MAY99, properly ammend man overboard procedures as to reflect actual procedures conducted by crew and master.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Lifesaving
Issued 29 April 1999 Resolved
Prior to 29MAY99, repair minor exhaust leak noted at bstb side generator raiser pipe.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 29 April 1999 Resolved
Prior to 29MAY99 properly install high water bilge level alarms (extended period by CID).
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Navigation
Issued 29 April 1999 Resolved
Prior to 29MAY99, loose or remove sackel pin for port and stb anchors as tomaintain ready access/use. Sackel pin is corroded to a point thta anchor can't be detached from stowage position.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Documentation
Issued 29 April 1999 Resolved
Prior to 29MAY99, re-register vessl EPIRB as to update owners address and phone numbers.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Navigation
Issued 29 April 1999 Resolved
Prior to 29MAY99 properly install marine grade navigation lights.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Navigation
Issued 29 April 1999 Resolved
Prior to 29MAY99, provide dark (black) background for nav lights casing, presently painted bright red.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Electrical
Issued 4 January 1996 Resolved
PROVE SATISFACTORY OPERATION OF THE PORT GENERATOR.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Engineering
Issued 6 January 1995 Resolved
REPAIR TACH ON PORT INBOARD MAIN ENGINE.
Condition: Unknown
Due 6 January 1995
Resolved 6 January 1995
Lifesaving
Issued 6 January 1995 Resolved
MAKE PERMANENT REPAIRS TO HANDRAIL ON MAN OVERBOARD RESCUE LADDER.
Condition: Unknown
Due 20 January 1995
Resolved 12 January 1995
Electrical
Issued 6 January 1995 Resolved
REPLACE LIGHT BULBS IN PORT AND STBD EXIT SIGNS.
Condition: Unknown
Due 20 January 1995
Resolved 12 January 1995
Documentation
Issued 6 June 1994 Resolved
Obtain revised stability letter allowing vessel to carry ballast in aft center ballast tank. Vessel may continue to carry ballast water until August 06, 1994, while Coast Guard Marine Safety Center reviews stability data and issues a new stability letter.
Condition: Unknown
Due 6 June 1994
Resolved 6 June 1994
Construction/Loadline
Issued 28 April 1994 Resolved
Conduct ultrasonic gauging of the after 50% bottom plate area in the engineroom and present test results to cognizant Officer in Charge, Marine Inspections.
Condition: Unknown
Due 5 May 1994
Resolved 18 May 1994
Construction/Loadline
Issued 14 August 1993 Resolved
Complete proper welding of maindeck 10 X 8 patch above engine room and subject same repair to nondestructive testing.
Condition: Unknown
Due 18 August 1993
Resolved 3 January 1994
Fire Fighting
Issued 13 August 1992 Resolved
PROVE PROPER OPERATION OF MAIN FIRE PUMP PRESSURE GUAGE. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 September 1992
Resolved 28 August 1992
Engineering
Issued 13 August 1992 Resolved
MAKE PERMANENT REPAIRS TO STBD OUTBOARD MDE SALT WATER SUCTION LINE AND_x001C_ TEST IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 9 September 1992
Resolved 28 August 1992
Engineering
Issued 7 April 1992 Resolved
IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR PROVE THAT NO EXHAUST LEAKS ARE PRESENT IN THE PORT MUFFLER COMPARTMENT.
Condition: Unknown
Due 7 May 1992
Resolved 12 May 1992
Lifesaving
Issued 15 August 1991 Resolved
MARK LIFE PRESERVER STORAGE AREA IN ACCORDANCE WITH 46 CFR 180.25-10._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Lifesaving
Issued 15 August 1991 Resolved
POST ON VESSEL EMERGENCY CHECK OFF LIST IN ACCORDANCE WITH 46 CFR 185.25-1 AND 46 CFR 185.25-5._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991
Lifesaving
Issued 15 August 1991 Resolved
INSTALL PROPER WEAKLINK FOR BUOYANT APPAUSTUS IN ACCORDANCE WITH 46 CFR 180.20._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 28 October 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.