Records from 1990 to 2019. Most recent: inspection, 30 September 2019.
Inspection history · 76
30 September 2019
ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6824550
6 September 2018
ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6533983
22 August 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 6245028
14 September 2015
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 5718821
19 January 2012
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4227874
18 June 2008
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3240403
18 June 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3240591
5 May 2008
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3199516
16 February 2008
MARPOL Annex I Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3148447
12 February 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3146465
13 January 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3129568
9 January 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3127615
5 December 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3109793
3 December 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3108808
30 March 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2898544
3 March 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2881209
1 March 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2880139
3 February 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2867436
31 January 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2865008
7 December 2005
Random ISPS/MTSA/PSC · Deficiency Check · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2547420
29 August 2005
Random ISPS/MTSA/PSC · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2478457
1 April 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2330444
4 March 2005
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2303217
4 March 2005
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2303733
8 February 2005
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2288904
2 February 2005
NPV Safety Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2285566
29 December 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2266707
30 November 2004
Random ISPS/MTSA/PSC
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2250429
29 October 2004
ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2230837
31 March 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2034408
1 February 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1998320
4 January 2004
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1974466
2 December 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1957222
4 March 2003
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1752318
2 February 2003
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1738682
29 December 2002
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1723919
25 November 2002
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1710202
21 November 2002
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1709121
15 October 2002
Annual Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1687702
13 May 2002
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1615966
26 November 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 295268
15 October 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 294460
31 May 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 725518
19 April 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 289295
8 February 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286612
19 October 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 214276
19 October 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 282873
21 March 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 275890
5 July 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 430202
26 April 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 427275
12 April 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 78057
28 October 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 701850
26 October 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 182393
13 October 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 421421
1 September 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 419833
8 July 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 417597
16 December 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 673181
27 October 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 409576
15 October 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 198606
10 June 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 404401
10 June 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 391906
17 August 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 518204
12 June 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 379227
12 December 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 473844
6 June 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 462773
24 May 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 474144
6 December 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 514139
8 November 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 668335
27 October 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 79810
19 July 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 524203
5 July 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 359268
21 June 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 512226
12 April 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 357602
1 June 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 479649
17 June 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 344376
23 June 1990
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 337879
Fire Fighting › Fire Main › Condition
Issued 23 January 2012
Resolved
0725(Fixed Fire Fighting Installation)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The ship has a leak in the fire main, reducing the available fire-fighting water supply. Cite: SOLAS74(09 CONS) I/11a
Action required: 705 - Other - as specified
Due 22 February 2012
Resolved 29 February 2012
Resolution: Sector Delaware Bay received Class Surveyor report from DNV attesting to the proper repair and testing of the leaking fire man.
Electrical › Electric Generation Source (service) › Generator
Issued 23 January 2012
Resolved
1430(Auxiliary Engines)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO noted excessive vibration on No.3 generator. Cite:SOLAS74(09 CONS) I/11a
Action required: 705 - Other - as specified
Due 22 February 2012
Resolved 29 February 2012
Resolution: Sector Delaware Bay received Class Surveyor report from DNV attesting to the proper repair and testing of the No. 3 Diesel Generator.
Fire Fighting › Fire Pumps › Location
Issued 23 January 2012
Resolved
0740(Pumps)-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Temporary rope line was being used to provide anti vibration to fire pump observed when ship's MDE was in operation. Cite:SOLAS74(09 CONS) I/11a
Action required: 705 - Other - as specified
Due 22 February 2012
Resolved 29 February 2012
Resolution: Sector Delaware Bay received Class Surveyor report from DNV attesting to the proper repair and testing of fire pump and the MDE.
Construction/Loadline › Hull › Hull Plating
Issued 16 February 2008
Resolved
During inspection of the hull noted crack on the fore peak area on the STB side of the anchor chaffing guide. Further investigation revealed no safety threat to the vessel or its crew. Area of damage is supported by the hull of the vessel. As per class repairs are to be conducted prior to March 3, 2008.
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 19 June 2008
Resolution: Recieved class report attesting to the repairs of the anchor chaffing guide.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 February 2008
Resolved
During inspection of the OWS and its pump through put, noted that the overboard discharge valve although visually closed was internally opened. As per class, replacement of the valve is to be conducted prior to March 7, 2008
Action required: 705 - Other - as specified
Due 7 March 2008
Resolved 6 May 2008
Resolution: The valve before overboard discharge valve removed and replaced with new manual shut off non-return valve.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 12 February 2008
Resolved
INOPERABLE HAS CONDITION FROM CLASS TO ALLOW TO OPERATE WITHOUT ONE.
Action required: 705 - Other - as specified
Due 28 July 2008
Resolved 28 July 2008
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 9 January 2008
Resolved
VESSEL'S ECHO DEPTH SOUNDER IS INOP
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Resolution: Cleared deficiency due to Sector LA/LB having the same opened deficiency. Echo Depth sounder remains inoperable.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 3 December 2007
Resolved
Inop Echo-Depth sounder
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2007
Resolution: Vessel provided class report stating that the echo-depth sounder is to be repaired at next dry dock.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 3 December 2007
Resolved
MF-HF Transceiver inop
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 19 June 2008
Resolution: Recieved class report attesting to repairs.
Navigation › Piloting/Steering › Chronometer
Issued 3 December 2007
Resolved
Speed Log inop. Flag exemption until installation at next drydock.
Action required: 705 - Other - as specified
Due 29 February 2008
Resolved 4 April 2011
Resolution: Sector Delaware Bay received statement from vessel''s master that speedlog was renewed during vessel''s last drydock in June 2010.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 3 March 2007
Resolved
Echo depth sounder found inoperable, and can only be repaired in drydock. Class report was issued approving the repair of the echo depth sounder at drydock and authorizing the ship to sail without an operating echo depth sounder until next dry dock or 29 JUL 2008, whichever comes first.
Action required: 705 - Other - as specified
Due 29 July 2008
Resolved 3 March 2007
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 1 March 2007
Resolved
Vessel has a condition of class to have the echo depth sounder repaired at the next drydock. The vessel is authorized by Flag and Class to sail without an operating echo depth sounder until next drydock or 29 JUL 2008, whichever comes first. .
Action required: 705 - Other - as specified
Due 29 July 2008
Resolved 8 April 2010
Resolution: vessel was provided with a new echo depth sounder
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 3 February 2007
Resolved
Echo depth sounder is inoperable due to a faulty transducer unit. There is currently an outstanding Condition of Class for the unit to be repaired at next dock due 29July2009.
Action required: 705 - Other - as specified
Due 29 July 2008
Resolved 3 March 2007
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 7 December 2005
Resolved
When conducting steering test the vessels rudder angle indicator was found to be up to 3 degrees off. Also when in non- follow up mode steering gear continuosly drifts., starboard. Additionally the previousissued deficiency from activity #2478457 was never corrected to the satisfaction of class.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 8 December 2005
Resolved 12 December 2005
Resolution: Sector Delaware Bay received fax from class attesting to the working conditions of the steering gear.
Fire Fighting › Fire Main › Condition
Issued 7 December 2005
Resolved
A steady leak was found in the fire main piping system near # 2 cargo hold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2006
Resolved 6 January 2006
Resolution: Recieved class report attesting to the satisfactory repair of vessel''s firemain.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 7 December 2005
Resolved
Vessels incinerator was found to be inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2006
Resolved 6 January 2006
Resolution: Received class report attesting to the satisfactory operation of vessel''s incinerator.
Construction/Loadline › Structures › Deck Plating
Issued 7 December 2005
Resolved
Large hole and excessive amounts of corrosion was found on the deck underneath vessels fresh water generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 January 2006
Resolved 6 January 2006
Resolution: Received class report attesting to sufficient repair of deck beneath fresh water generator.
Lifesaving › Lifeboat › Hull
Issued 29 August 2005
Resolved
Port lifeboat was found with hull damage, starboard side oft and temporary repair inplace. water was found underneath patch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 August 2005
Resolution: Surveyor and CG Inspector attested to repair made prior to departure. Patch was replaced.
Engineering › Steering Gear System › Motor
Issued 29 August 2005
Resolved
#2 steering motor had bearing vibration noise when operating.
Action required: 705 - Other - as specified
Due 7 October 2005
Resolved 12 December 2005
Resolution: Recieved class report attesting to satisfactory operation of vessel''s steering gear.
Fire Fighting › Remote Fuel Shutoff › General
Issued 2 February 2005
Resolved
REMOTE FUEL SHUTDOWN FOR EMERGENCY GENERATOR NOT WORKING
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 March 2005
Resolved 4 March 2005
Resolution: REMOTE FUEL SHUTOFF FOR EMERGENCY GENERATOR WAS CORRECTED.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 2 February 2005
Resolved
STEAM SLUDGE LINE IN SHAFT ALLEY STB. SIDE NEEDS SOFT PATCH REMOVED AND REPAIR PIPE
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 March 2005
Resolved 4 March 2005
Resolution: SOFT PATCH WAS REMOVED FROM STEAM PIPE LINE AND NEW PIPPING WAS INSTALLED.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 2 February 2005
Resolved
ALL FIRE DOORS IN HOUSE CAN NOT BE CLOSED PROPERLEY.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 March 2005
Resolved 4 March 2005
Resolution: ALL FIRE DOORS IN THE WHEEL HOUSE WERE CORRECTED.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 February 2005
Resolved
COVERS FOR ENGINE ROOM LIGHTS MISSING, EXPOSED WIRING.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 March 2005
Resolved 4 March 2005
Resolution: ENGINE ROOM LIGHT COVERS WERE INSTALLED AND ALL WIRING WERE CORRECTED.
Engineering › Steering Gear System › Pump
Issued 2 February 2005
Resolved
STEERING GEAR HYDROLIC FLUID LEAKING FROM BOTH PUMPS
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 March 2005
Resolved 4 March 2005
Resolution: STEARING GEAR LEAK WAS CORRECTED.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 December 2003
Resolved
Main deck railing on stbd side, next to #2 cargo hold was found to be broken. As required by ILO 147. To be corrected w/in 30 days or prior to next U.S. port of call after sailing foreign. LEGACY COMPONENT DESC: Deck Rail
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 January 2004
Resolved 4 January 2004
Construction/Loadline › Markings
Issued 2 December 2003
Resolved
Load lines, indicating marks, and marks of assigning authority were found not to be permanently affixed. As required by ICLL, 1966/Reg.8. To be corrected w/in 30 days or prior to next U.S. port of call after sailing foreign. LEGACY COMPONENT DESC: Load Line Mark
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 January 2004
Resolved 4 January 2004
Lifesaving › Lifeboat Equipment
Issued 2 December 2003
Resolved
Tiller bars were found to be missing from each lifeboat. As required by Solas 74/78 Ch.III/reg.41.7.2. To be corrected w/in 30 days or prior to next U.S. port of call after sailing foreign. LEGACY COMPONENT DESC: Tiller Bar
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 2 January 2004
Resolved 4 January 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 25 November 2002
Resolved
RAILING ON AFT FOREPEAK PORT SIDE AND THE #1 BILGE VENT ARE BENT/DAMAGED.ILO 147 REGULATION LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 December 2002
Resolution: Damaged railing has been repaired.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 November 2002
Resolved
LADDER RAILING LEADING UP TO FOREPEAK ON STARBOARD SIDE IS WASTED/BENT.ILO 147 REGULATION LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 December 2002
Resolution: Ladder railing leading up to forepeak on starboard side has been repaired.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 November 2002
Resolved
AFT FOREPEAK DECK RAILING BY LADDER RAILING ON STARBOARD SIDE IS WASTED/ BENT.
ILO 147 REGULATION LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 December 2002
Resolution: Deck railing by ladder railing on aft forepeak on starboard side has been repaired.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 November 2002
Resolved
DECK RAILING BY CARGO HOLD #3 PORT SIDE IS WASTED/BENT.ILO 147 REGULATION LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 December 2002
Resolution: Deck railing by cargo hold was repaired.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 November 2002
Resolved
LADDER FOR CAT WALK ADJACENT TO #2 HOLD PORT SIDE IS WASTED.ILO 147 REGULATION LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 December 2002
Resolution: Ladder for catwalk has been repaired.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 November 2002
Resolved
DECK RAILING ADJACENT TO #2 CARGO HOLD STARBOARD ISDE IS WASTED/ BROKEN. ILO 147 REGULATION. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 December 2002
Resolution: Deck railing was repaired.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 November 2002
Resolved
CATWALK AND CONTAINER BUMPER OADJACENT TO #2 CARGO HOLD STARBOARD SIDE WAS WASTED/ MISSING/ BROKEN. ILO 147 REGULATION LEGACY COMPONENT DESC: CAT WALK/ CONTAINER GUARD
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 December 2002
Resolution: Catwalk Repaired.
Deck/Cargo › Mooring/Anchoring
Issued 25 November 2002
Resolved
#5 MOORING LINE STARBOARD SIDE WAS WASTED AND DETERMINED TO BE UNSAFE FOR USE. SOLAS74/78 CHAP III REG 19. CORRECTIVE ACTIONS REQUIRED, TAKE LINE OUT OF SERVICE. LEGACY COMPONENT DESC: Mooring Line/Hawser
Condition: Improper/Lack of Maintenance
Due 25 November 2002
Resolved 29 December 2002
Resolution: Ship has replaced worn mooring line with new.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 October 2002
Resolved
MISSING SAFETY RAIL ON MAIN DECK, STBD SIDE, ADJACENT TO #2 CARGO HOLD. ILO 147 REGULATION. TO BE CORRECTED IN 30 DAYS. LEGACY COMPONENT DESC: Deck Rail
Due 15 November 2002
Resolved 25 November 2002
Resolution: SAFTEY RAIL WAS INSTALLED ON MAIN DECK, STRB SIDE, ADJACENT TO #2 CARGO HOLD
Accommodation/Occupational Safety › Occupational Safety
Issued 15 October 2002
Resolved
BROKEN CAT WALK ON MAIN DECK, STBD SIDE, NEXT TO #1 CRANE HOUSE. ILO 147 REGULATION. TO BE CORRECTED IN 30 DAYS. LEGACY COMPONENT DESC: Cat Walk
Due 15 November 2002
Resolved 25 November 2002
Resolution: REPAIRED THE CATWALK WITH NEW METAL AND PROPERLY PAINTED FOR TRIP HAZARD.
Construction/Loadline › Markings
Issued 15 October 2002
Resolved
LOADLINE, DRAFT MARKINGS, & PLIMSOLL MARK IS NOT PAINTED IN CONTRASTING COLOR OR PERMANENTLY AFFIXED TO HULL. ILLC 66 REGULATION. TO BE CORRECTED IN 30 DAYS. LEGACY COMPONENT DESC: Loadline, Draft Markings, & Plimsoll Mark
Due 15 November 2002
Resolved 25 November 2002
Resolution: PIANTED AND PERMENATLY AFFIXED TO THE VESSEL HULL
Pollution Prevention/Response › Prevention Equipment
Issued 15 October 2002
Resolved
THE FIXED CONTAINMENT MECHANICAL MEANS OF CLOSURE FOR SOME OF THE F/O, LO/, & D/O VENTS AND/OR MANIFOLD CONNECTIONS WERE MISSING OR INADEQUATE. 33 CFR 156.120 REGULATION. TO BE CORRECTED PRIOR TO NEXT BUNKERING IN A U.S. PORT. LEGACY COMPONENT DESC: Fixed Containment
Action required: 703 - Prior to bunkering operations
Resolved 16 October 2002
Resolution: ALL OF THE SUBJECT FIXED CONTAINMENTS WERE FOUND TO HAVE ADEQUATE MECHANICAL MEANS OF CLOSURE.
Deck/Cargo › Mooring/Anchoring
Issued 15 October 2002
Resolved
STBD ANCHOR WINDLESS WAS FOUND TO BE LEAKING AN EXCESSIVE AMOUNT OF HYDRAULIC OIL INTO ITS FIXED CONTAINMENT; MAKING IT A POTENTIAL FOR AN OIL SPILL DISCHARGE. MARPOL 73/78 ANNEX I/REG.9 & 33CFR151.10 REGULATIONS. TO BE CORRECTED IN 30 DAYS. LEGACY COMPONENT DESC: Anchor Windless
Due 15 November 2002
Resolved 25 November 2002
Resolution: STBD ANCHOR WINDLESS WAS FOUND TO BE LEAK FREE.
Fire Fighting › Fire Hydrants › Condition
Issued 15 October 2002
Resolved
NUMEROUS FIRE HYDRANTS, NOZZLES, & HOSES ARE MISSING ADEQUATE RUBBER SEAL/GASKETS.
SOLAS 74/78 CHAP.II-2 REG.21 REGULATION. TO BE CORRECTED PRIOR TO DEPARTURE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2002
Resolution: ALL OF THE SUBJECT FIRE HYDRANTS, NOZZLES, & HOSES WERE FOUND TO HAVE ADEQUATE RUBBER SEAL/GASKETS.
Fire Fighting › Fire Hydrants › Condition
Issued 15 October 2002
Resolved
FIRE HYDRANT GATE VALVE, LOCATED IN THE ENGINE ROOM BILGE FLAT, AFT SECTION, WAS FOUND TO BE LEAKING. SOLAS 74/78 CHAP.II-2 REG.21 REGULATION. TO BE CORRECTED IN 30 DAYS.
Due 15 November 2002
Resolved 16 October 2002
Resolution: THE SUBJECT HYDRANT WAS FOUND TO BE LEAK-FREE.
Electrical › Electric Generation Source (service)
Issued 15 October 2002
Resolved
VSL'S #2 MAIN GENERATOR FOUND TO BE INOPERABLE DUE TO FAULTY CRANK SHAFT. SOLAS 74/78 CHAP.II-1 REG.41 REGULATION. MASTER STATED NEW CRANK SHAFT ON ORDER. VSL TO PROVIDE THE LOCAL USCG OCMI A COPY OF THE CLASS RPT ATTESTING THE SAT. OPERATION OF THE SUBJECT GENERATOR, ONCE REPAIRS COMPLETED. LEGACY COMPONENT DESC: Generator
Action required: 705 - Other - as specified
Due 30 May 2003
Resolved 2 December 2003
Resolution: Def. Cleared.
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 15 October 2002
Resolved
VESSEL MISSING THE REQUIRED NTM'S (WEEKS 21 TO THE PRESENT) TO MAKE THE CORRECTIONS TO THEIR CHARTS, LIGHT LISTS, & COAST PILOTS. 33 CFR 164.33 REGULATION. TO BE CORRECTED PRIOR TO DEPARTURE.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2002
Resolution: VERIFIED THAT THE VSL HAD THE SUBJECT NTM''S ON BOARD.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 15 October 2002
Resolved
ECHO DEPTH SOUNDER WAS FOUND TO BE INOPERABLE. 33 CFR 164.33(h) REGULATION. TO BE CORRECTED PRIOR TO DEPARTURE. REQUEST FOR OUTBOUND TRANSIT WAS DENIED, LOD 64-02 DENIAL WAS ISSUED TO THE VESSEL.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2002
Resolution: RCVD TECH REPORT ATTESTING TO THE PROPER OPERATION OF THE SUBJECT DEPTH SOUNDER. LOD 64-02 WAS RECINDED.
Lifesaving
Issued 15 October 2001
Resolved
FOOD RATIONS ON BOTH LIFEBOATS NOT IN AIRTIGHT PACKAGING.
Condition: Unknown
Due 17 October 2001
Resolved 19 October 2001
Fire Fighting
Issued 15 October 2001
Resolved
VALVE HANDLE LOCATED AFT ON BRDGE BROKE OFF WHILE ENERGIZING FIRE HOSE.
Condition: Unknown
Due 16 October 2001
Resolved 16 October 2001
Navigation
Issued 15 October 2001
Resolved
COULD NOT CONDUCT STEERING TEST DURING BOARDING DUE TO MAINTENANCE OF AUTO PILOT CONTROL BY TECHNICIAN. ROUTINE MAINTENANCE.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Navigation
Issued 19 April 2001
Resolved
VESSEL DOES NOT HAVE CURRENT EDITION OF USCG LIGHT LIST VOL II.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Navigation
Issued 19 October 2000
Resolved
Echo depth sounder and depth sounder repeater inoperable.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Engineering
Issued 19 October 2000
Resolved
Oil containment bins around vents lacking mechanical plugs.
Condition: Unknown
Due 8 February 2001
Resolved 8 February 2001
Navigation
Issued 21 March 2000
Resolved
VESSEL'S RADAR WAS INOPERATIVE DURING INBOUND TRANSIT.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Engineering
Issued 26 April 1999
Resolved
PIPELINE DIAGRAM MISSING FROM OIL TRANSFER PROCEDURES. CPRRECT PRIOR TO NEXT U.S. BUNKERING.
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Navigation
Issued 13 October 1998
Resolved
INOP GYRO COMPASS. TECHNICIAN REPORT REQUIRED BEFORE VESSEL DEPARTURE.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Unknown
Issued 8 July 1998
Resolved
Numerous discrepancies were noted on the class annual survey which was conducted the same day as the Coast Guard's AEF. Discrepancies will be corrected by 31AUG98 and MSO Philly should receive a letter from class stating so.
Condition: Unknown
Due 1 September 1998
Resolved 1 September 1998
Construction/Loadline
Issued 8 July 1998
Resolved
Vessel's load line was not painted in a contrasting color as required by ILLC 66 Annex l/8. _x001C_ _x001C_ *CORRECT PRIOR TO DEPARTURE*
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Navigation
Issued 8 July 1998
Resolved
Vsl missing U.S. Coast Pilot [name withheld] _x001C_ _x001C_ _x001C_ *CORRECT PRIOR TO DEPARTURE*
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Construction/Loadline
Issued 10 June 1997
Resolved
CLASS REPORT REQUIRED FOR DAMAGE TO THE BOW FROM A COLLISION IN A FORIGN PORT
Condition: Unknown
Due 11 June 1997
Resolved 17 June 1997
Documentation
Issued 10 June 1997
Resolved
A VIO OF SOLAS IN THAT THE SAFETY EQUIPMENT CERTIFICATE WAS MISSING THE ANNUAL ENDORCEMENT.
Condition: Unknown
Due 11 June 1997
Resolved 17 June 1997
Fire Fighting
Issued 10 June 1997
Resolved
A VIO OF SOLAS IN THAT THE VESSEL BROKE A FIRE HOSE WHEN PRESURE WAS PLACEDON IT.
Condition: Unknown
Due 11 June 1997
Resolved 17 June 1997
Accommodation/Occupational Safety
Issued 10 June 1997
Resolved
A VIO OF ILO-147 IN THAT THERE WAS A CREW MEMBER WAS LIVING IN THE HOSPITALSPACE.
Condition: Unknown
Due 11 June 1997
Resolved 17 June 1997
Navigation
Issued 10 June 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 June 1996
Resolved 10 June 1996
Unknown
Issued 12 June 1995
Resolved
VIO OF MARPOL 73\78 REG10 OWS AUTOMATIC STOP DID NOT WORK
Condition: Unknown
Due 14 June 1995
Resolved 15 June 1995