MAURY USCG vessel records Sign in
← All vessels

MARTINI

MARTINI is a 1990 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1990, most recently in May 2026, along with 58 deficiencies and 2 operational controls.

Records from 1990 to 2026. Most recent: inspection, 27 May 2026.

Built
1990
Last inspected
27 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

350965
Flag
UNITED STATES
—
Maury page id
psix-350965

Inspections, by type

…with no type recorded1
Years with a record 29 calendar years (1990–2026)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it3 - Simplified, Gross Ton
2 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 50

27 May 2026 Drydock Extension · Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8382109
27 August 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8214246
2 July 2024 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7946277
22 May 2024 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7907507
8 May 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7677327
31 May 2022 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7464054
11 May 2022 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7452304
16 September 2019 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6815530
5 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6697922
2 May 2019 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6655593
20 April 2018 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6383448
9 May 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6141280
18 April 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6132412
16 August 2016 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5984108
19 April 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5857296
8 April 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5849883
27 May 2014 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4866157
24 May 2012 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4320749
7 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4203580
1 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4199643
1 October 2008 Simplified Stability Test
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3337788
10 June 2008 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3232495
18 March 2008 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3166117
30 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3139035
25 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2937466
24 August 2006 Hull Examination · Internal Structural Exam · Periodic Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2756483
5 July 2005 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2414953
30 June 2004 Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2115284
10 March 2004 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2021386
11 June 2003 MARPOL Annex V Examination · COI Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1814291
18 March 2003 Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1758783
6 October 2000 Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1365987
26 August 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1423243
21 May 1999 Plan Review "T" Boat · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1388832
10 May 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1129998
15 April 1999 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1411868
27 August 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 797643
25 August 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 785023
11 April 1997 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1100684
28 August 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1250516
23 May 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936870
13 August 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878124
15 July 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175090
15 April 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175087
2 September 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1145122
3 June 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942989
8 April 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942988
7 September 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942410
6 September 1990 Initial Certification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902762
21 June 1990 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1223307

Deficiency record · 58

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 August 2025 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in an SMI. Provide approved alcohol testing devices on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2025
Resolved 5 September 2025
Resolution: ALCO strips onboard.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 27 August 2025 Resolved
At each initial and subsequent inspection for certification and reinspection the firefighting equipment of all vessels shall be inspected. Provide an annual inspection report for the pre-engineered fixed gas extinguishing system. 46 CFR 176.25-25(a) Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2025
Resolved 5 September 2025
Resolution: Fireboy serviced. Manual pull cable renewed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 August 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. The current onboard chart is not current.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2025
Resolved 5 September 2025
Resolution: New
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 August 2025 Resolved
The minimum number of portable fire extinguishers required on each vessel shall be as determined by the Officer in Charge, Marine Inspection, in accordance with Table 181.30-1(a). Vessel is missing required 10-B:C portable fire extinguisher at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2025
Resolved 5 September 2025
Resolution: New purchased.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 August 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. The required analgesics and burn gel were expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2025
Resolved 5 September 2025
Resolution: New first aid kit on board
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 27 August 2025 Resolved
Spaces containing machinery shall be fitted with adequate ventilation. All ducts shall be of rigid permanent construction of fire proof material and reasonably gastight from end to end. The port and starboard ventilation ducts presented with holes in the ducting within the fwd compartment. Repair to the satisfaction of the attending MI. 46 CFR 182.20-45(d) Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2025
Resolved 5 September 2025
Resolution: Ventilation ducting wrapped with HVAC foil tape
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 27 August 2025 Resolved
At each inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Multiple large penetrations were observed in the forward and aft bulkhead of the engine room. Seal all penetrations in the bulkhead due to the fixed fire extinguishing system. 46 CFR 176.25-50 Old T
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 September 2025
Resolved 5 September 2025
Resolution: Penetration filled with firestop foam
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2025 Resolved
It is intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personnel injury. A split was identified in the coolant overflow hose and the fuel tank ventilation hose. Renew. 46 CFR 182.01-5 Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2025
Resolved 5 September 2025
Resolution: Hoses renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 May 2023 Resolved
Each hatch exposed to the weather must be watertight except it may be weathertight if the vessel operates only on protected waters. Aft hatch is cracked.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 24 May 2023
Resolution: New hatch installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 15 May 2023 Resolved
Rails shall consist of evenly spaced courses and spacing between courses shall not be greater than 12". Spacing is currently 16".
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 24 May 2023
Resolution: With ACID approval, temporary rail course installed.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 15 May 2023 Resolved
The vessel stability letter must be posted under glass or kept onboard in a weathertight container available to the crew and passengers. No stability letter is onboard.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 15 May 2023
Resolution: Obtained stability letter and addendum from misle and emailed it to operator to be placed onboard.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 15 May 2023 Resolved
The master and crew will be familiar with the content of and have mounted at the operating station, emergency instructions for actions to be taken in case of fire, heavy weather, and MOB. If no suitable mounting surface exists, it may be kept onboard. No muster/emergency instructions onboard.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 May 2023
Resolution: Muster/emergency instructions have been placed onboard.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 May 2023 Resolved
A marine employer whose vessel is involved in a casualty that becomes a serious marine incident shall comply with the alcohol testing requirements of 46 CFR part 4, requiring alcohol testing within 2 hours. No alcohol swabs onboard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2023
Resolved 23 May 2023
Resolution: New alcohol swabs placed onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 May 2023 Resolved
The name (state registration numbers) of the vessel shall be marked on both sides of the bow. State numbers are only on the stbd side.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 15 May 2023
Resolution: Marked the port bow with state registration number stickers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2023 Resolved
When the flexible section of the fill pipe is a nonconductor, the metallic sections of the filling pipe shall be joined by a conductor for protection against static spark when filling. Wire is no longer connected.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 May 2023
Resolution: Wire has been properly reconnected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 May 2023 Resolved
Battery terminals shall be soldered and all connections shall be made to the battery terminals with permanent type connectors. Battery cables are loose.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 May 2023
Resolution: Battery cables have been tightened.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 May 2023 Resolved
All wiring shall be run as high as practicable above bilges. Cables for fireboy are drooping down through the engine space.
Action required: 10 - Deficiency Rectified
Resolved 15 May 2023
Resolution: Cable has been secured to the overhead in the engine space.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 31 May 2022 Resolved
Each vessel must be equipped with at least two operable portable battery lights. Flashlights must be located at the operating station and at entry to the propulsion machinery space. One flashlight in inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 10 June 2022
Resolution: Two new flashlights onboard. Test:SAT
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 May 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First-aid kit contains multiple expired products.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 14 June 2022
Resolution: New First Aid Kit placed onboard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 May 2022 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. No buckets found onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 15 June 2022
Resolution: Operator received new fire buckets and placed onboard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 May 2022 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. No way to secure air intake to protected space.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2022
Resolved 10 June 2022
Resolution: Air vent covers purchased and placed onboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 September 2019 Resolved
Railing on vessel found bent and broken and unable to support 200LBS IAW CFR 46 CFR 177.900(b)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 October 2019
Resolved 23 May 2022
Resolution: During hull exam, railings were found in adequate condition.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 5 June 2019 Resolved
LABLE FIRE BUCKETS AND INSTALL LINE ON FIRE BUCKETS
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2019
Resolved 22 December 2020
Resolution: cleared requirement.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 16 August 2016 Resolved
Launch operator didn't have MMC on her person.
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 16 August 2016
Resolution: Launch operator terminate operations until MMC provided, the master of S/V CHRISTEEN assumed duties for the day.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 16 August 2016 Resolved
Vessel was found operating in excess of COI maximum allowable child size type I lifejackets. 09 onboard when COI maximum is 02
Action required: 705 - Other - as specified
Due 16 August 2016
Resolved 16 August 2016
Resolution: Interim vessel operations manager was educated on site not to exceed launch COI requirements for child size type I lifejackets.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 10 May 2016 Resolved
Provide vessel registration from NY state.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 15 June 2016
Resolution: provided.
Engineering › Diesel Engine (propulsion-electric) › Valve
Issued 10 May 2016 Resolved
Repair raw water leak on the MDE.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 15 June 2016
Resolution: provided.
Communications › Alarms/Indicators › High Water Alarm
Issued 10 May 2016 Resolved
Repair or replace bilge high level alarm.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 15 June 2016
Resolution: repaired.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 10 May 2016 Resolved
Service fixed fire fighting system
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 21 June 2016
Resolution: replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 May 2016 Resolved
Service portable fire extinguishers
Due 13 May 2016
Resolved 21 June 2016
Resolution: serviced.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 10 May 2016 Resolved
Replace waterlight battery.
Due 13 May 2016
Resolved 2 June 2016
Resolution: Battery replaced with approved battery.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 May 2016 Resolved
Label life rig and install retro tape.
Due 13 May 2016
Resolved 15 June 2016
Resolution: Retro tape installed and labeled.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 10 May 2016 Resolved
Provide MIS report and after hour testing arrangements.
Due 13 May 2016
Resolved 15 June 2016
Resolution: provided.
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 10 May 2016 Resolved
Install battery box covers
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 15 June 2016
Resolution: installed.
Construction/Loadline › Structures › Scupper
Issued 19 April 2016 Resolved
Deck scuppers need to be free to open. Arrange fenders to allow for scuppers to open.
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 28 September 2016
Resolution: Item cleared under activity 5849883 on 28SEEP16.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 19 April 2016 Resolved
Shaft log Starboard side set screw needs repaired, contact boat builder for repair. Submit to CG for approval.
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 2 June 2016
Resolution: Repaired as per manf.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 19 April 2016 Resolved
Sterntube is fractured IVA of cutlass bearing set screw (set screw missing). Make repairs as as per manfature recommedations PTCHE.
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 2 June 2016
Resolution: Repairs made as per manf.
Stability › Freeing Ports › General
Issued 8 April 2016 Resolved
Deck freeing ports are blocked by finders. Rearange finders to allow for free movement of scuppers prior to credit hull exam.
Action required: 705 - Other - as specified
Due 19 April 2016
Resolved 28 September 2016
Resolution: Attended vessel and operationally tested freeing ports. Water flowed out of ports with newly installed devices to keep fenders off of hull.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 May 2014 Resolved
Make aft bulkhead in engine space air tight
Condition: Placed in Improper Service
Due 7 June 2014
Resolved 7 June 2014
Resolution: Corrected
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 27 May 2014 Resolved
Secure lifeline around body of lifering
Condition: Improper Installation
Due 27 May 2014
Resolved 27 May 2014
Resolution: corrected on the spot
Fire Fighting › Fire Bucket › Availability
Issued 27 May 2014 Resolved
Provide 3 fire buckets
Condition: Placed in Improper Service
Due 27 May 2014
Resolved 27 May 2014
Resolution: corrected on the spot
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 May 2014 Resolved
provide aspirin
Condition: Placed in Improper Service
Due 27 May 2014
Resolved 27 May 2014
Resolution: corrected on the spot
Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 December 2011 Resolved
O/O failed to complete an annual inspection within required time frame. O/O stated he will perform the inspection in the spring 2012. Issued (1) CG-835 restricting vessel to not sailing with passengers.
Action required: 705 - Other - as specified
Resolved 1 May 2012
Resolution: Completed an Annual Inspection.
Documentation › Certificates/Documents › Stability Letter
Issued 1 December 2011 Resolved
Due to new 185 lbs AAWPP that became effective Dec 1, 2011, the vessel passenger capacity is reduced to 15 persons total of which 14 may be passengers.
Action required: 705 - Other - as specified
Resolved 23 April 2012
Resolution: Completed SAT Annual Exam.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 June 2008 Resolved
Tamper seal missing from manual actuating locking pin.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 June 2008
Resolved 10 June 2008
Resolution: replaced date of inspection.
Documentation › Certificates/Documents › Stability Letter
Issued 17 March 2008 Resolved
Provide proof of vessel stability adequate to enable the cognizant OCMI to issue a stability letter for this vessel.
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 1 October 2008
Resolution: SST conducted.
Stability › Incline Test › General
Issued 30 January 2008 Resolved
Conduct stability test
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 10 June 2008
Resolution: See note w/ act 3232495. freeboard readings taken for comparison w/ other Crosby launches in an attempt to establish sisterships for stability purposes.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 July 2005 Resolved
Replace 6 Adult and 3 Child Life jackets, passenger count reduced until need is met.
Condition: Unknown
Due 15 July 2005
Resolved 10 August 2005
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 5 July 2005 Resolved
Replace engine mount
Condition: Improper Installation
Due 15 July 2005
Resolved 10 August 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 June 2004 Resolved
Replace light used for all around white light IAW COLREGS.
Due 7 July 2004
Resolved 13 August 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 June 2004 Resolved
Replace battery in water light.
Due 7 July 2004
Resolved 13 August 2004
Navigation › Piloting/Steering › Marine Charts
Issued 30 June 2004 Resolved
Provide chart on navigational area of the launch's operation.
Due 7 July 2004
Resolved 13 August 2004
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 30 June 2004 Resolved
Provide list of crew on consortium and pre-limenary drug tests.
Due 7 July 2004
Resolved 13 August 2004
Engineering
Issued 6 October 2000 Resolved
DEMONSTRATE SATISFACTORY OPERATION OF THE ENGINE AND CONTROLS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 January 2002
Resolved 11 June 2003
Lifesaving
Issued 6 October 2000 Resolved
DEMONSTRATE CREW PROFICIENCY VIA MAN OVERBOARD, FIRE AND ABANDON SHIP DRILLS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 6 January 2002
Resolved 11 June 2003
Fire Fighting
Issued 10 May 1999 Resolved
CONDUCT INSTALLATION INSPECTION AND TESTS FOR PRE-ENGINEERED HALON SYSTEM.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Engineering
Issued 15 April 1999 Resolved
RENEW CUTLASS BEARING.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Accommodation/Occupational Safety
Issued 15 April 1999 Resolved
REPAIR SUPPORT FOR BENCH SEATING, PORT SIDE FWD.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999

Ownership record