MAURY USCG vessel records Sign in
← All vessels

CARILLON

CARILLON is a 1990 passenger vessel (inspected). The Coast Guard has recorded 48 inspections since 1990, most recently in June 2025, along with 22 deficiencies, 1 operational control and 1 casualty investigation in 2017.

Records from 1990 to 2025. Most recent: inspection, 23 June 2025.

Built
1990
Last inspected
23 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCP5323
350995
Flag
UNITED STATES
367037460
Maury page id
psix-350995

Inspections, by type

…with no type recorded3
Years with a record 31 calendar years (1990–2025)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.0 ft × 11.0 ft × 7.0 ft
Registered tonnagegross 30 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSCARANO BOATBUILDING INC. · ALBANY, NY, UNITED STATES · built 1990
Hull materialWood
PropulsionDiesel Direct
Hull shapeShip
Hull configurationMonohull
Hailing portTICONDEROGA, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Gross Ton
24 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH9601MMSI 367037460 · active · compulsorily equipped · granted 7 February 2025, expires 30 April 2035
WCP5323MMSI not assigned · expired · compulsorily equipped · granted 29 December 1994, cancelled 5 March 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 48

23 June 2025 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8165959
3 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8087343
31 May 2024 DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7926396
13 June 2023 DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7714634
28 September 2022 DAPI Audit
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7568892
6 June 2022 Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7470050
26 May 2022 COI Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7460055
19 July 2021 DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7261679
22 March 2021 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7160433
8 May 2020 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6950465
27 June 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6728576
6 November 2018 Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6589942
28 June 2018 DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6460011
20 August 2017 Damage Survey
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6249133
20 August 2017 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6260184
10 May 2017 DAPI Audit · COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 6130021
18 July 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5948787
3 August 2015 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 5205517
13 September 2011 Simplified Stability Test
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4144543
19 July 2011 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4088692
21 May 2008 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3206423
16 May 2007 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2919656
15 May 2006 Annual Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2660113
27 May 2005 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2414880
27 April 2005 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2344469
27 May 2004 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2086926
15 May 2003 MARPOL Annex II Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1796177
16 May 2002 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1621642
1 June 2001 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1461425
30 May 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1468147
24 April 2000 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 823617
21 April 2000 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1404972
25 October 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1472358
15 October 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1441572
12 May 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1438921
22 January 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 787704
1 June 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1131513
15 May 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1102208
12 November 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 861940
17 May 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1083400
22 May 1995 Hull Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1185198
19 May 1995 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 871165
26 May 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1178503
1 November 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852606
11 May 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 844216
28 May 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946303
12 June 1991 Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1244990
30 June 1990 Deficiency Check · COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249079

Deficiency record · 22

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 3 March 2025 Resolved
Assess the cracks in the transverse floor frames accordingly and provide an assessment of the damage and a plan for repair if need be. ] Prior to credit DDX
Action required: 705 - Other - as specified
Resolved 7 April 2025
Resolution: Vessel completed repairs to floors IAW approved repair plan
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 June 2019 Resolved
Provide properly working waterlight prior to operating at night.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2019
Resolved 1 July 2019
Resolution: New waterlight was purchased and installed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 May 2008 Resolved
UV deterioration found on 19 original PFDs.
Due 21 May 2008
Resolved 21 May 2008
Resolution: Replaced immediately.
Documentation › Logs/Records › Drug Test Records
Issued 27 May 2004 Resolved
Prove DAPI program is instituted.
Due 27 June 2004
Resolved 27 July 2004
Resolution: Resolved
Navigation › Emergency Steering
Issued 16 May 2002 Resolved
No emergency tiller for single engine vessel. Provide plans for review nlt 31AUG02. Repair to be completed prior to MAY03.
Action required: 705 - Other - as specified
Due 16 May 2003
Resolved 18 July 2002
Resolution: 46 CFR 182.30-5 of "Old T" requires emergency steering for vsls on oceans and coastwise service only. Thus not required for this vsl (L,B,S).
Fire Fighting
Issued 25 October 1999 Resolved
Submit plans for the installation of a fire detection system for the enginespace. Upon approval, install a fire detecton system to the satisfation ofan attending CG marine inspector.
Condition: Unknown
Due 25 October 1999
Resolved 25 October 1999
Construction/Loadline
Issued 12 May 1999 Resolved
Provide plans for making a vapor tight barrier between machinery/fuel spaces and accomodation spaces.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Lifesaving
Issued 17 May 1996 Resolved
PROVIDE AND PROPERLY MARK A PROPER CONTAINER FOR DISTRESS SIGNALS.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Unknown
Issued 17 May 1996 Resolved
POST POLLUTION PREVENTION PLACARD.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Lifesaving
Issued 17 May 1996 Resolved
PROVIDE PROPER LINE AND LANYARD FOR RING BUOY.
Condition: Unknown
Due 17 May 1996
Resolved 17 May 1996
Accommodation/Occupational Safety
Issued 22 May 1995 Resolved
SUBMIT FOR APPROVAL PLANS FOR HEATING SYSTEM TO THE SATIFACTION OF THE ATTENDING MARINE INSPECTOR PLAN REVIEWER.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Fire Fighting
Issued 1 November 1993 Resolved
PRIOR TO 11MAY94, PROVIDE ADDITIONAL FIRE EXTINGUISHERS AS FOLLOWS: ONE B- I, ONE B-II. BOTH ARE TO BE FOR MARINE USE. INSTALLATION IS TO BE TO THE SATISFACTION OF [name withheld] THIS MUST BE COMPLETED PRIOR TO CARRIAGE OFPASSENGERS.
Condition: Unknown
Due 1 November 1993
Resolved 1 November 1993
Engineering
Issued 30 June 1990 Resolved
STENCIL "FUEL SHUT OFF" NEAR ACCESS COVER.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Electrical
Issued 30 June 1990 Resolved
DEMONSTRATE GPM CAPACITY OF ELECTRIC BILGE PUMP.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Fire Fighting
Issued 30 June 1990 Resolved
PROVIDE AND MOUNT 2 BII SIZE FIRE EXTINGUISHERS VICE 2 BI SIZE/1 IN ENG SPACE AND ONE IN CONTROL STATION.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Lifesaving
Issued 30 June 1990 Resolved
PROVIDE 6 RED DISTRESS FLARES.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Accommodation/Occupational Safety
Issued 30 June 1990 Resolved
PROVIDE A SUITABLE PORT AND STARBOARD ENGINE ROOM VENTILATION SYSTEM (ONE LOWER).
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Engineering
Issued 30 June 1990 Resolved
PROPERLY SUPPORT STERN LOG WATER LINE.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Construction/Loadline
Issued 30 June 1990 Resolved
PROVIDE ADDITIONAL ATTACHMENT OF THE FIRST SIX FRAMES TO THE LOG AS REQUIRED BY [name withheld] LTR 16715/CARILLON DATED 26 JUNE 1990.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Lifesaving
Issued 30 June 1990 Resolved
PROVIDE PROPER STOWAGE FOR ALL LIFE PRESERVERS SO THEY ARE READILY ACCESSIBLE.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Lifesaving
Issued 30 June 1990 Resolved
PROVIDE USCG APPROVED RING BUOY WITH 6 OFF LINE AND USCG APPROVED WATERLIGHT ATTACHED AND PROPERLY MOUNTED.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Navigation
Issued 30 June 1990 Resolved
PROVIDE A SUITABLE MEANS FOR EMERGENCY STEERING.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991

Casualty record · 1

20 August 2017Routine · role: Involved in a Marine Casualty · activity 6260184
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.