R/V JOHN DEMPSEY

R/V JOHN DEMPSEY is a 1990 passenger vessel (inspected). The Coast Guard has recorded 66 inspections since 1990, most recently in June 2026, along with 115 deficiencies, 1 operational control and 1 casualty investigation in 2006.

Records from 1990 to 2026. Most recent: inspection, 1 June 2026.

Built
1990
Last inspected
1 June 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAN9694
351264
Flag
UNITED STATES
367058813
Maury page id
psix-351264

Inspections, by type

…with no type recorded5
Years with a record 34 calendar years (1990–2026)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.3 ft × 5.8 ft
Registered tonnagegross 31 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA FAB · PASCAGOULA, MS, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portOLD LYME, CT
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Simplified, Gross Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAN9694MMSI 367058813 · active · compulsorily equipped · granted 18 June 2026, expires 6 August 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

1 June 2026 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8385743
10 March 2025 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8083451
10 February 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8042159
27 March 2024 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7875187
1 March 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7642655
25 January 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7625792
30 November 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7348692
26 July 2021 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7238639
25 June 2021 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7235624
1 December 2020 Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7089146
16 July 2020 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7007552
8 November 2019 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6848464
19 March 2019 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6644253
29 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6526113
1 March 2018 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6364012
11 July 2017 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6208997
11 April 2017 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6122213
2 December 2016 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6051673
29 March 2016 COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5842538
27 May 2014 Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4871447
10 July 2012 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4374482
7 May 2012 Internal Structural Exam · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4302212
22 July 2011 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4090441
2 November 2010 Plan Review "T" Boat · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3882969
30 July 2009 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3550411
14 July 2009 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3530095
20 March 2009 Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3437254
1 July 2008 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3292719
22 May 2008 Type not recorded
No type recorded · Station New Haven · USCG Northeast District (CGD-NE) · Activity 3214136
26 March 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3172150
15 May 2007 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2933701
2 August 2006 Annual Inspection · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2733966
10 July 2006 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2720105
7 March 2006 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2598113
7 June 2005 Annual Inspection · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2382502
3 May 2004 Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2079762
10 March 2004 Internal Structural Exam · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2021769
3 September 2003 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1895983
14 July 2003 Internal Structural Exam · Annual Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1846298
29 April 2002 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1608981
13 August 2001 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1443233
31 May 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1426403
27 March 2000 Plan Review "T" Boat · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1452654
27 May 1999 COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1453613
10 August 1998 Re-Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 790347
10 April 1998 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1127788
6 March 1998 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1118768
31 July 1997 Hull Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 781332
10 June 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878688
10 June 1996 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1123468
24 April 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878806
22 August 1995 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 875075
18 October 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869655
25 July 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 862065
28 April 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 862063
23 June 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 843503
21 August 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944665
7 April 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1256608
12 November 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1252321
15 August 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245116
12 February 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907354
15 January 1991 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1221980
28 August 1990 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1226625
21 August 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927091
19 July 1990 Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 915116
16 January 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1226378

Deficiency record · 115

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 June 2026 Resolved
Vessel had on board 06 flares. Limited Coastwise Route requires vessel have 12 Flares (6 hand red, and 6 orange smoke or 12 hand red). Provide flares for limited coastwise route. Vessel restricted to lakes, bays, and sounds.
Action required: 10 - Deficiency Rectified
Resolved 1 June 2026
Resolution: Vessel now has 12 flares.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 June 2026 Resolved
Vessel required FCC Station License (expired 8/6/2025), while operating beyond 1000' from shore. Provide copy of valid FCC Station License.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 13 July 2026
Resolution: Rec'd pic of valid FCC Station License, updated in MISLE
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 June 2026 Resolved
Masthead light couldn't be verified as turned on. Check light and verify it is working. Vessel restricted to day time operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 2 June 2026
Resolution: all nav lights working
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 June 2026 Resolved
Aspirin in the 1st Aid kit is expired. Provide at least 48 doses of analgesic for the 1st aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 2 June 2026
Resolution: aspirin replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 1 June 2026 Resolved
Hatches are required to have captive chains to prevent loss of the hatch. The forepeak and aft exit of the engine room hatches need a captive chain attached.
Action required: 10 - Deficiency Rectified
Resolved 1 June 2026
Resolution: Captive chains added
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 March 2023 Resolved
Provide service report for E/R Halon System, overdue for service as of Nov 2022.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2023
Resolution: completed, re-conditioned "new" bottle installed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 March 2023 Resolved
Topmost lifefloat is severely sun damaged. Repair as per manuf instructions or provide new. Total capacity is restricted to 20 people beyond 3 miles from shore in cold water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 10 August 2023
Resolution: completed
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 March 2023 Resolved
Complete fire/abandonship/MOB drills in presence of a marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2023
Resolved 14 April 2023
Resolution: completed underway
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 March 2023 Resolved
Provide new nozzle for fire hose on deck. Current nozzle rusted and not providing a pressured spray. Prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2023
Resolution: done
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 March 2023 Resolved
Provide new painter for lifefloats as well as new lines from lifefloat to waterlights. Line has been deteriorated by the sun.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2023
Resolution: provided
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 March 2023 Resolved
Re-label RLB on aft deck, can no longer see vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 14 April 2023
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 March 2023 Resolved
Provide new hydrostatic release for liferaft on forward deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 14 April 2023
Resolution: provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 March 2023 Resolved
Missing panel at operating station to enclose the exposed wires. Provide panel and cover exposed wires.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2023
Resolved 14 April 2023
Resolution: completed
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 1 March 2023 Resolved
General housekeeping, vessel has just come from dry dock, but inside areas are in need of some TLC. Please clean up spaces and remove hazards.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2023
Resolution: Huge effort made, boat was very clean and orderly when we went on board.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 March 2023 Resolved
Provide Lifejacket donning placards for each type of lifejacket on board. Place in a conspicuous place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 1 March 2023
Resolution: cleared
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 June 2021 Resolved
A vessel that is exposed to salt water more than 3mths in any 12mth period must undergo a drydock examination and internal structural examination at least once every 2yrs. Complete credit dry dock prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2021
Resolution: Completed Hull/ISE.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 December 2020 Resolved
Prove proper operation of bilge alarms. Panel for alarms did not work.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2020
Resolved 26 July 2021
Resolution: Bilge alarm panel works properly.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 December 2020 Resolved
Provide new battery for EPIRB. Vessel route limited to within 3nm of shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021
Resolved 19 January 2021
Resolution: rec'd new epirb, updated info in MISLE
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 December 2020 Resolved
Label Lifefloat (new) with vessel name and capacity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2020
Resolved 26 July 2021
Resolution: Life float is marked properly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 July 2020 Resolved
Replace 12 person life float. LF basket straps were wasted and found to be unserviceable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 1 December 2020
Resolution: new LF
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2020 Resolved
Prove proper operation of aft bilge alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2020
Resolved 17 July 2020
Resolution: Recieved photos and videio evidence of the aft bilge alarm working properly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 July 2020 Resolved
Conduct annual servicing of fixed halon system and provide report.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 11 August 2020
Resolution: Recieved servicing report via photo.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 July 2020 Resolved
Provide additional flares for limited coast wise route. Vessel is required 12 and has 07 on board.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2020
Resolved 17 July 2020
Resolution: New flares on board.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2019 Resolved
Remove stray wires at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 18 November 2019
Resolution: Installed covering for dead end wires.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 8 November 2019 Resolved
Replace port center window at operating station. Crack in window is impeding visibility.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 1 December 2020
Resolution: replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 November 2019 Resolved
Repair/Replace catch on forward hatch cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 18 November 2019
Resolution: repaired
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 8 November 2019 Resolved
Repair/replace aft bilge alarm. Tested during inspection and it was not working, no audible or visual at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2019
Resolved 18 November 2019
Resolution: installed and operational
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 8 November 2019 Resolved
Provide cover plate on engine (clutch housing).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 18 November 2019
Resolution: installed
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 29 August 2018 Resolved
Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V) and no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 18 March 2019
Resolution: The vessels proper name is R/V JOHN DEMPSEY. Deficiency issued in error.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 1 March 2018 Resolved
Inspect Halon system. Bottle was partially discharged and will need to be re-charged. A no-sail item was generated. Will need to be inspected and charged prior to taking on passengers. A control measure was generated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2018
Resolution: System charged and inspected.
Engineering › Bilge Water Management System › Piping
Issued 1 March 2018 Resolved
Repair engine room bilge suction pipe. Pipe has a hole in it. A control measure was generated. Operator understands that prior to taking passengers the pipe will have to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2018
Resolution: pipe repaired
Electrical › Lighting (service) › Lighting Fixture
Issued 1 March 2018 Resolved
Repair light fixture in lazerate.
Condition: Improper/Lack of Maintenance
Due 1 April 2018
Resolved 25 April 2018
Resolution: light repaired.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 1 March 2018 Resolved
Provide MMC for Capt.
Due 1 April 2018
Resolved 25 April 2018
Resolution: MMC provided
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 1 March 2018 Resolved
Add crew member to random drug testing program.
Due 1 April 2018
Resolved 25 April 2018
Resolution: member added.
Navigation › Collision/Grounding Avoidance › Radar
Issued 1 March 2018 Resolved
Prove operation of Marine Radar
Due 1 April 2018
Resolved 25 April 2018
Resolution: radar operated.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 March 2018 Resolved
Repair flood light STBD. Light is located on the AFT STBD corner of the cabin.
Due 1 April 2018
Resolved 25 April 2018
Resolution: light repaired.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 July 2017 Resolved
Replace all batteries in float lights.
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: Batteries replaced.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 July 2017 Resolved
Provide L/S maintenance log
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: log generated
Communications › Audible Communications › Bell
Issued 11 July 2017 Resolved
Install bell
Due 11 August 2017
Resolved 14 July 2017
Resolution: bell installed
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 July 2017 Resolved
Provide new start batteries for generator and MDE.
Due 11 August 2017
Resolved 14 July 2017
Resolution: batteries installed.
Lifesaving › Lifefloat › Markings
Issued 11 July 2017 Resolved
Label life floats with vessel name.
Due 11 July 2017
Resolved 14 July 2017
Resolution: life float labeled.
Construction/Loadline › Structures › Ventilators
Issued 11 July 2017 Resolved
Secure port vent cover on cabin
Due 11 August 2017
Resolved 14 July 2017
Resolution: vent cover secured.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 July 2017 Resolved
Repair navigation light.
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: light repaired
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 July 2017 Resolved
provide one flashlight.
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: installed.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 11 July 2017 Resolved
Install bonding wire.
Condition: Improper/Lack of Maintenance
Due 14 July 2017
Resolved 14 July 2017
Resolution: wire installed.
Engineering › Steering Gear System › Ram
Issued 11 July 2017 Resolved
adjust bolts on steering gear ram
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: Bolts tightened
Communications › Alarms/Indicators › High Water Alarm
Issued 11 July 2017 Resolved
adjust high water alarm. Bolt restricting lever
Condition: Improper Installation
Due 11 August 2017
Resolved 14 July 2017
Resolution: High water alarm lever moved.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 March 2016 Resolved
Provide valid COD.
Due 15 April 2016
Resolved 2 February 2017
Resolution: Valid COD provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 March 2016 Resolved
Repair stern light prior to operating at night or reduced visibility.
Action required: 705 - Other - as specified
Resolved 2 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 March 2016 Resolved
Provide asprin and eye-wash for first aid kit.
Due 8 May 2016
Resolved 2 June 2016
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 May 2014 Resolved
Properly label deck side of escape hatch in foward compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 June 2014
Resolved 6 June 2014
Resolution: Escape hatch properly labeled.
Fire Fighting › Combustible Materials › Insulation
Issued 27 May 2014 Resolved
Removing mattress padding from thruster space.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 June 2014
Resolved 6 June 2014
Resolution: Padding removed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 May 2014 Resolved
Prove operation of lighting fixture in halon room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 June 2014
Resolved 6 June 2014
Resolution: Fixture proved operable.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 May 2014 Resolved
Properly splice wiring in head cabinet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2014
Resolved 6 June 2014
Resolution: Wiring properly spliced.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 May 2014 Resolved
Properly repair and install exposed cables leading into distribution panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2014
Resolved 6 June 2014
Resolution: Cables and panel properly prepared and installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 May 2014 Resolved
Prove operation of bilge high level alarm in main hold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2014
Resolved 6 June 2014
Resolution: High level alarm proved operable.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 May 2012 Resolved
Prove proper operation of E/R high level alarm.
Due 7 July 2012
Resolved 10 July 2012
Lifesaving › Lifefloat › Float Free
Issued 7 May 2012 Resolved
Correct life float arrangement to allow independent deployment.
Due 7 July 2012
Resolved 10 July 2012
Resolution: Added 20 feet of line.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 7 May 2012 Resolved
Replace pit cock on generator fuel filter with plug.
Due 7 July 2012
Resolved 10 July 2012
Accommodation/Occupational Safety › Ventilation › General
Issued 7 May 2012 Resolved
Repair or replace E/R intake fan port side.
Due 7 July 2012
Resolved 10 July 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 November 2010 Resolved
Arrange mast head light and running light as per Rule 23, Annex I of the navrules 33 CFR 84.03(g). This requires that sidelights be placed at least one meter lower than the forward masthead light.
Due 3 March 2011
Resolved 25 April 2011
Resolution: Mastlight removed from pilothouse top and moved to mast. White all-around light on mast now has a shield providing 225 degree arc for forward mast light.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 20 March 2009 Resolved
Secure all gear adrift (entire vessel).
Due 14 April 2009
Resolved 14 July 2009
Resolution: Gear adrift properly stowed.
Communications › Radio Communications › EPIRB
Issued 20 March 2009 Resolved
Mark off expiration date on hydrostatic release for EPIRB for two years from purchase.
Due 14 April 2009
Resolved 14 July 2009
Resolution: Hydrostatic release propely marked.
Lifesaving › Lifefloat › Float Free
Issued 20 March 2009 Resolved
Removed gear stowed in lifefloats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2009
Resolution: Gear removed from lifefloats.
Documentation › Certificates/Documents › FCC SSL
Issued 20 March 2009 Resolved
Provide FCC Safety Radio Certificate and MROP for vessel's master.
Due 14 May 2009
Resolved 14 July 2009
Resolution: FCC Safety readio and MROP certificates provided.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 March 2009 Resolved
Remove dead end cable in engine room.
Due 14 April 2009
Resolved 14 July 2009
Resolution: Dead end cable removed.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 10 March 2004 Resolved
Provide proof of current servicing of fixed halon extinguishing system & bottle prior to operating with passengers. LEGACY COMPONENT DESC: Tanks
Condition: Unknown
Due 15 March 2004
Resolved 3 May 2004
Construction/Loadline › Structures
Issued 10 March 2004 Resolved
Provide captive device for lazzerette deck hatch, prove watertightness of same and pump out bilge water. LEGACY COMPONENT DESC: Manhole
Condition: Improper/Lack of Maintenance
Due 10 April 2004
Resolved 3 May 2004
Construction/Loadline › Markings
Issued 10 March 2004 Resolved
Repaint draft markings as necessary prior to refloating vessel. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 15 March 2004
Resolved 11 March 2004
Lifesaving › Buoyant Apparatus
Issued 10 March 2004 Resolved
Provide lanyards for lifefloat paddles. LEGACY COMPONENT DESC: Paddles
Condition: Placed in Improper Service
Due 10 April 2004
Resolved 3 May 2004
Electrical › Electrical Distribution System (service)
Issued 10 March 2004 Resolved
Provide metallic cable clamps in engineroom overhead in way of emergency escape. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Due 10 April 2004
Resolved 3 May 2004
Construction/Loadline › Structures
Issued 10 March 2004 Resolved
Label emergency escapes from engineroom and crew space with minimum 2 inch lettering. LEGACY COMPONENT DESC: Machinery Space Opening
Due 10 April 2004
Resolved 3 May 2004
Engineering › Sea-water System (primary cooling)
Issued 14 July 2003 Resolved
Repair weld on raw water cooling piping to/from MDE, and temp gauge on the hydraulic tank for steering system. LEGACY COMPONENT DESC: Piping
Due 14 August 2003
Resolved 2 September 2003
Resolution: Spoke to vessel rep and pipe was repaired.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 14 July 2003 Resolved
Prove proper operation of fixed fire fighting system. LEGACY COMPONENT DESC: Test system
Due 14 August 2003
Resolved 2 September 2003
Resolution: Received fax copy of servicing report.
Fire Fighting
Issued 27 May 1999 Resolved
Re-route air line from inside of stbd e/r vent to permit vent closure
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Fire Fighting
Issued 27 May 1999 Resolved
Clean or replace Fixed Fire Extinguishing system instruction placard
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Engineering
Issued 27 May 1999 Resolved
Double clamp generator raw water hoses
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Lifesaving
Issued 27 May 1999 Resolved
Provide donning placards which match the lifejackets carried on board.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Electrical
Issued 27 May 1999 Resolved
Make proper electrical connection of shore tie wiring in box in stack.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Electrical
Issued 27 May 1999 Resolved
Submit for approval - Plans for installation and wiring of engine room ventilation system
Condition: Unknown
Due 5 April 2000
Resolved 5 April 2000
Fire Fighting
Issued 27 May 1999 Resolved
Add instructions for shutting down generator to Fixed Fire Extinguishing instructions
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Electrical
Issued 27 May 1999 Resolved
Install covers on bunk lights in berthing area
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Engineering
Issued 27 May 1999 Resolved
Repair stbd remote fuel shutoff cable
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Construction/Loadline
Issued 27 May 1999 Resolved
Double clamp marine sanitation device salt water hose.
Condition: Unknown
Due 31 March 2000
Resolved 31 March 2000
Lifesaving
Issued 10 August 1998 Resolved
PROVIDE NEW NETTING FOR BOTH LIFEFLOATS.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Lifesaving
Issued 10 August 1998 Resolved
REPLACE (VIA NEW SPLICED IN SECTION) WORN PAINTER.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Lifesaving
Issued 10 August 1998 Resolved
PROVIDE A SERVICING REPORT FOR THE 6-PERSON LIFERAFT.
Condition: Unknown
Due 10 September 1998
Resolved 15 March 1999
Lifesaving
Issued 10 August 1998 Resolved
REATTACH PAINTER ON BOTTOM LIFEFLOAT SO IT IS ATTACHED TO THE MAIN PAINTER.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Accommodation/Occupational Safety
Issued 10 August 1998 Resolved
PROPERLY BRACE THE COFFEE POT.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Documentation
Issued 10 August 1998 Resolved
PROVIDE REQUIREMENTS FOR DRUG PROGRAM AS NOTED ON AUDIT FORM.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Lifesaving
Issued 10 August 1998 Resolved
PROVIDE ON-BOARD STOWAGE FOR ALL ADULT PFD'S.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Construction/Loadline
Issued 10 August 1998 Resolved
PROVIDE DOCUMENTATION ON WEIGHT CHANGES INVOLVING ADDITIONAL OF BALLAST IN HOLD.
Condition: Unknown
Due 10 September 1998
Resolved 15 March 1999
Fire Fighting
Issued 10 August 1998 Resolved
PROVIDE SERVICING REPORT FOR FIXED EXTINGUISHING SYSTEM._x001C_
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Engineering
Issued 10 August 1998 Resolved
REPLACE BOTH FLAMES SCREENS ON FUEL TANK VENTS.
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Electrical
Issued 31 July 1997 Resolved
INSTALL DRIP PROOF COVERS OVER THE BATTERY CHARGERS.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Engineering
Issued 31 July 1997 Resolved
INSTALL PROPER FANBELT FOR MAIN ENGINE'S ALTERNATOR.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Construction/Loadline
Issued 31 July 1997 Resolved
PROVER PROPER OPERATION OF THE VALVE LOCATED AFT OF THE COLLISION BULKHEAD.IF ACCESS IS OBSTRUCTED, VALVE MUST BE FITTED WITH A REACH ROD.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Lifesaving
Issued 31 July 1997 Resolved
REPLACE ASPRIN IN FIRST AID KIT.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Documentation
Issued 31 July 1997 Resolved
PROVIDE PROOF OF 60 MINUTE INSTRUCTION OF THE DRUG TESTING PROGRAM FOR THE OPERATOR.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Navigation
Issued 31 July 1997 Resolved
PROVIDE UPDATED CHARTS, COAST PILOT AND LIGHT LIST.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Documentation
Issued 31 July 1997 Resolved
PROVIDE VALID RADOITELEPHONY CERTIFICATE.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Engineering
Issued 31 July 1997 Resolved
PROPERLY HARD PIPE THE FUEL OIL SUPPLY FROM THE PORT TANK TO THE FUEL OIL MANIFOLD IAW APPROVED PLANS.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Navigation
Issued 31 July 1997 Resolved
PROVIDE A 200MM BELL.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Lifesaving
Issued 31 July 1997 Resolved
PROVIDE RETRO TAPE TO ALL 4 QUAD./SIDES TO BOTH REQUIRED RING BOUYS.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Construction/Loadline
Issued 31 July 1997 Resolved
EITHER CHANGE BILGE PIPING BACK TO IT'S ORIGINAL DESIGN BASED UPON THE APPROVED PLANS DTD 19JUL90 OR REVISE PLAN TO SHOW MODIFICATIONS AND SUBMIT TO [name withheld].
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Engineering
Issued 31 July 1997 Resolved
PROPERLY HARD PIPE THE FUEL OIL SUPPLY FROM THE FUEL OIL MANIFOLD TO THE S/S DIESEL GENERATOR IAW APPROVED PLANS.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Accommodation/Occupational Safety
Issued 10 June 1996 Resolved
Label emergency escape from engineroom.
Condition: Unknown
Due 10 July 1996
Resolved 25 October 1996
Lifesaving
Issued 10 June 1996 Resolved
Provide new battery for epirb.
Condition: Unknown
Due 10 July 1996
Resolved 25 October 1996
Construction/Loadline
Issued 10 June 1996 Resolved
Repair bilge alarm in forepeak.
Condition: Unknown
Due 10 July 1996
Resolved 25 October 1996
Navigation
Issued 10 June 1996 Resolved
Prove proper operation of the air tank relief valve.
Condition: Unknown
Due 10 July 1996
Resolved 25 October 1996
Navigation
Issued 15 January 1991 Resolved
PROVIDE A LETTER OF ALTERNATE COMPLIANCE FOR STERNLIGHT AFTER REQUEST TO COGNIZANT DISTRICT COMMANDER.
Condition: Unknown
Due 15 January 1991
Resolved 15 January 1991
Documentation
Issued 19 July 1990 Resolved
PROVIDE VALID FCC STATION LICENSE AND OPERATOR'S LICENSE.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Documentation
Issued 19 July 1990 Resolved
PROVIDE MASTER'S COAST GUARD LICENSE.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Navigation
Issued 19 July 1990 Resolved
PROVIDE A LETTER OF ALTERNATE COMPLIANCE FOR STERNLIGHT AFTER REQUEST TO COGNIZANT DISTRICT COMMANDER.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990
Engineering
Issued 19 July 1990 Resolved
REVISE BILGE SYSTEM DRAWING TO INCLUDE INSTALLED ELECTRIC BILGE PUMP AND ASSOCIATED PIPING. SUBMIT REVISED PLANS TO COGNIZANT OCMI.
Condition: Unknown
Due 19 July 1990
Resolved 19 July 1990

Casualty record · 1

10 July 2006Routine · role: Involved in a Marine Casualty · activity 2720105
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.