11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 June 2026
Resolved
Vessel had on board 06 flares. Limited Coastwise Route requires vessel have 12 Flares (6 hand red, and 6 orange smoke or 12 hand red). Provide flares for limited coastwise route. Vessel restricted to lakes, bays, and sounds.
Action required: 10 - Deficiency Rectified
Resolved 1 June 2026
Resolution: Vessel now has 12 flares.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 June 2026
Resolved
Vessel required FCC Station License (expired 8/6/2025), while operating beyond 1000' from shore. Provide copy of valid FCC Station License.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 13 July 2026
Resolution: Rec'd pic of valid FCC Station License, updated in MISLE
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 June 2026
Resolved
Masthead light couldn't be verified as turned on. Check light and verify it is working. Vessel restricted to day time operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 2 June 2026
Resolution: all nav lights working
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 June 2026
Resolved
Aspirin in the 1st Aid kit is expired. Provide at least 48 doses of analgesic for the 1st aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 2 June 2026
Resolution: aspirin replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 1 June 2026
Resolved
Hatches are required to have captive chains to prevent loss of the hatch. The forepeak and aft exit of the engine room hatches need a captive chain attached.
Action required: 10 - Deficiency Rectified
Resolved 1 June 2026
Resolution: Captive chains added
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 March 2023
Resolved
Provide service report for E/R Halon System, overdue for service as of Nov 2022.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2023
Resolution: completed, re-conditioned "new" bottle installed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 March 2023
Resolved
Topmost lifefloat is severely sun damaged. Repair as per manuf instructions or provide new. Total capacity is restricted to 20 people beyond 3 miles from shore in cold water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 10 August 2023
Resolution: completed
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 March 2023
Resolved
Complete fire/abandonship/MOB drills in presence of a marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2023
Resolved 14 April 2023
Resolution: completed underway
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 March 2023
Resolved
Provide new nozzle for fire hose on deck. Current nozzle rusted and not providing a pressured spray. Prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2023
Resolution: done
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 March 2023
Resolved
Provide new painter for lifefloats as well as new lines from lifefloat to waterlights. Line has been deteriorated by the sun.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2023
Resolution: provided
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 March 2023
Resolved
Re-label RLB on aft deck, can no longer see vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 14 April 2023
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 March 2023
Resolved
Provide new hydrostatic release for liferaft on forward deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 14 April 2023
Resolution: provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 March 2023
Resolved
Missing panel at operating station to enclose the exposed wires. Provide panel and cover exposed wires.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2023
Resolved 14 April 2023
Resolution: completed
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 1 March 2023
Resolved
General housekeeping, vessel has just come from dry dock, but inside areas are in need of some TLC. Please clean up spaces and remove hazards.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2023
Resolution: Huge effort made, boat was very clean and orderly when we went on board.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 March 2023
Resolved
Provide Lifejacket donning placards for each type of lifejacket on board. Place in a conspicuous place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 1 March 2023
Resolution: cleared
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 June 2021
Resolved
A vessel that is exposed to salt water more than 3mths in any 12mth period must undergo a drydock examination and internal structural examination at least once every 2yrs. Complete credit dry dock prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2021
Resolution: Completed Hull/ISE.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 December 2020
Resolved
Prove proper operation of bilge alarms. Panel for alarms did not work.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2020
Resolved 26 July 2021
Resolution: Bilge alarm panel works properly.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 December 2020
Resolved
Provide new battery for EPIRB. Vessel route limited to within 3nm of shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021
Resolved 19 January 2021
Resolution: rec'd new epirb, updated info in MISLE
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 December 2020
Resolved
Label Lifefloat (new) with vessel name and capacity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2020
Resolved 26 July 2021
Resolution: Life float is marked properly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 July 2020
Resolved
Replace 12 person life float. LF basket straps were wasted and found to be unserviceable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 1 December 2020
Resolution: new LF
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2020
Resolved
Prove proper operation of aft bilge alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2020
Resolved 17 July 2020
Resolution: Recieved photos and videio evidence of the aft bilge alarm working properly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 July 2020
Resolved
Conduct annual servicing of fixed halon system and provide report.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 11 August 2020
Resolution: Recieved servicing report via photo.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 July 2020
Resolved
Provide additional flares for limited coast wise route. Vessel is required 12 and has 07 on board.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2020
Resolved 17 July 2020
Resolution: New flares on board.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2019
Resolved
Remove stray wires at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 18 November 2019
Resolution: Installed covering for dead end wires.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 8 November 2019
Resolved
Replace port center window at operating station. Crack in window is impeding visibility.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 1 December 2020
Resolution: replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 November 2019
Resolved
Repair/Replace catch on forward hatch cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 18 November 2019
Resolution: repaired
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 8 November 2019
Resolved
Repair/replace aft bilge alarm. Tested during inspection and it was not working, no audible or visual at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2019
Resolved 18 November 2019
Resolution: installed and operational
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 8 November 2019
Resolved
Provide cover plate on engine (clutch housing).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 18 November 2019
Resolution: installed
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 29 August 2018
Resolved
Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V) and no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 18 March 2019
Resolution: The vessels proper name is R/V JOHN DEMPSEY. Deficiency issued in error.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 1 March 2018
Resolved
Inspect Halon system. Bottle was partially discharged and will need to be re-charged. A no-sail item was generated. Will need to be inspected and charged prior to taking on passengers. A control measure was generated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2018
Resolution: System charged and inspected.
Engineering › Bilge Water Management System › Piping
Issued 1 March 2018
Resolved
Repair engine room bilge suction pipe. Pipe has a hole in it. A control measure was generated. Operator understands that prior to taking passengers the pipe will have to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2018
Resolution: pipe repaired
Electrical › Lighting (service) › Lighting Fixture
Issued 1 March 2018
Resolved
Repair light fixture in lazerate.
Condition: Improper/Lack of Maintenance
Due 1 April 2018
Resolved 25 April 2018
Resolution: light repaired.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 1 March 2018
Resolved
Provide MMC for Capt.
Due 1 April 2018
Resolved 25 April 2018
Resolution: MMC provided
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 1 March 2018
Resolved
Add crew member to random drug testing program.
Due 1 April 2018
Resolved 25 April 2018
Resolution: member added.
Navigation › Collision/Grounding Avoidance › Radar
Issued 1 March 2018
Resolved
Prove operation of Marine Radar
Due 1 April 2018
Resolved 25 April 2018
Resolution: radar operated.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 March 2018
Resolved
Repair flood light STBD. Light is located on the AFT STBD corner of the cabin.
Due 1 April 2018
Resolved 25 April 2018
Resolution: light repaired.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 July 2017
Resolved
Replace all batteries in float lights.
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: Batteries replaced.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 July 2017
Resolved
Provide L/S maintenance log
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: log generated
Communications › Audible Communications › Bell
Issued 11 July 2017
Resolved
Install bell
Due 11 August 2017
Resolved 14 July 2017
Resolution: bell installed
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 July 2017
Resolved
Provide new start batteries for generator and MDE.
Due 11 August 2017
Resolved 14 July 2017
Resolution: batteries installed.
Lifesaving › Lifefloat › Markings
Issued 11 July 2017
Resolved
Label life floats with vessel name.
Due 11 July 2017
Resolved 14 July 2017
Resolution: life float labeled.
Construction/Loadline › Structures › Ventilators
Issued 11 July 2017
Resolved
Secure port vent cover on cabin
Due 11 August 2017
Resolved 14 July 2017
Resolution: vent cover secured.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 July 2017
Resolved
Repair navigation light.
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: light repaired
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 July 2017
Resolved
provide one flashlight.
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: installed.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 11 July 2017
Resolved
Install bonding wire.
Condition: Improper/Lack of Maintenance
Due 14 July 2017
Resolved 14 July 2017
Resolution: wire installed.
Engineering › Steering Gear System › Ram
Issued 11 July 2017
Resolved
adjust bolts on steering gear ram
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: Bolts tightened
Communications › Alarms/Indicators › High Water Alarm
Issued 11 July 2017
Resolved
adjust high water alarm. Bolt restricting lever
Condition: Improper Installation
Due 11 August 2017
Resolved 14 July 2017
Resolution: High water alarm lever moved.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 March 2016
Resolved
Provide valid COD.
Due 15 April 2016
Resolved 2 February 2017
Resolution: Valid COD provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 March 2016
Resolved
Repair stern light prior to operating at night or reduced visibility.
Action required: 705 - Other - as specified
Resolved 2 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 March 2016
Resolved
Provide asprin and eye-wash for first aid kit.
Due 8 May 2016
Resolved 2 June 2016