MAURY USCG vessel records
← All vessels

R/V JOHN DEMPSEY

Built
1990
Last inspected
1 June 2026
Documentation
Case Pending · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 June 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAN9694
351264
Flag
UNITED STATES
Maury page id
psix-351264

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.3 ft × 5.8 ft
Registered tonnagegross 31 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA FAB · PASCAGOULA, MS, UNITED STATES · built 1990
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portOLD LYME, CT
Endorsements, as the file codes themcw_un, fi
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it31 - Simplified, Gross Ton
25 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 50 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

1 June 2026 Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8385743
10 March 2025 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8083451
10 February 2025 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8042159
27 March 2024 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7875187
1 March 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7642655
25 January 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7625792
30 November 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7348692
26 July 2021 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7238639
25 June 2021 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7235624
1 December 2020 Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7089146
16 July 2020 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7007552
8 November 2019 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6848464
19 March 2019 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6644253
29 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6526113
1 March 2018 Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6364012
11 July 2017 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6208997
11 April 2017 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6122213
2 December 2016 Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6051673
29 March 2016 COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5842538

Deficiency record · 50

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 June 2026 Resolved
Vessel had on board 06 flares. Limited Coastwise Route requires vessel have 12 Flares (6 hand red, and 6 orange smoke or 12 hand red). Provide flares for limited coastwise route. Vessel restricted to lakes, bays, and sounds.
Action required: 10 - Deficiency Rectified
Resolved 1 June 2026
Resolution: Vessel now has 12 flares.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 June 2026 Resolved
Vessel required FCC Station License (expired 8/6/2025), while operating beyond 1000' from shore. Provide copy of valid FCC Station License.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 13 July 2026
Resolution: Rec'd pic of valid FCC Station License, updated in MISLE
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 June 2026 Resolved
Masthead light couldn't be verified as turned on. Check light and verify it is working. Vessel restricted to day time operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 2 June 2026
Resolution: all nav lights working
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 June 2026 Resolved
Aspirin in the 1st Aid kit is expired. Provide at least 48 doses of analgesic for the 1st aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2026
Resolved 2 June 2026
Resolution: aspirin replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 1 June 2026 Resolved
Hatches are required to have captive chains to prevent loss of the hatch. The forepeak and aft exit of the engine room hatches need a captive chain attached.
Action required: 10 - Deficiency Rectified
Resolved 1 June 2026
Resolution: Captive chains added
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 March 2023 Resolved
Provide service report for E/R Halon System, overdue for service as of Nov 2022.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2023
Resolution: completed, re-conditioned "new" bottle installed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 March 2023 Resolved
Topmost lifefloat is severely sun damaged. Repair as per manuf instructions or provide new. Total capacity is restricted to 20 people beyond 3 miles from shore in cold water.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 10 August 2023
Resolution: completed
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 March 2023 Resolved
Complete fire/abandonship/MOB drills in presence of a marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2023
Resolved 14 April 2023
Resolution: completed underway
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 March 2023 Resolved
Provide new nozzle for fire hose on deck. Current nozzle rusted and not providing a pressured spray. Prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2023
Resolution: done
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 March 2023 Resolved
Provide new painter for lifefloats as well as new lines from lifefloat to waterlights. Line has been deteriorated by the sun.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2023
Resolution: provided
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 March 2023 Resolved
Re-label RLB on aft deck, can no longer see vessel name.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 14 April 2023
Resolution: completed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 1 March 2023 Resolved
Provide new hydrostatic release for liferaft on forward deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 April 2023
Resolved 14 April 2023
Resolution: provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 March 2023 Resolved
Missing panel at operating station to enclose the exposed wires. Provide panel and cover exposed wires.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2023
Resolved 14 April 2023
Resolution: completed
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 1 March 2023 Resolved
General housekeeping, vessel has just come from dry dock, but inside areas are in need of some TLC. Please clean up spaces and remove hazards.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 April 2023
Resolution: Huge effort made, boat was very clean and orderly when we went on board.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 March 2023 Resolved
Provide Lifejacket donning placards for each type of lifejacket on board. Place in a conspicuous place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 March 2023
Resolved 1 March 2023
Resolution: cleared
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 June 2021 Resolved
A vessel that is exposed to salt water more than 3mths in any 12mth period must undergo a drydock examination and internal structural examination at least once every 2yrs. Complete credit dry dock prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 July 2021
Resolution: Completed Hull/ISE.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 1 December 2020 Resolved
Prove proper operation of bilge alarms. Panel for alarms did not work.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 December 2020
Resolved 26 July 2021
Resolution: Bilge alarm panel works properly.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 December 2020 Resolved
Provide new battery for EPIRB. Vessel route limited to within 3nm of shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2021
Resolved 19 January 2021
Resolution: rec'd new epirb, updated info in MISLE
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 December 2020 Resolved
Label Lifefloat (new) with vessel name and capacity.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2020
Resolved 26 July 2021
Resolution: Life float is marked properly.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 July 2020 Resolved
Replace 12 person life float. LF basket straps were wasted and found to be unserviceable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 1 December 2020
Resolution: new LF
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 July 2020 Resolved
Prove proper operation of aft bilge alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2020
Resolved 17 July 2020
Resolution: Recieved photos and videio evidence of the aft bilge alarm working properly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 July 2020 Resolved
Conduct annual servicing of fixed halon system and provide report.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 11 August 2020
Resolution: Recieved servicing report via photo.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 July 2020 Resolved
Provide additional flares for limited coast wise route. Vessel is required 12 and has 07 on board.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2020
Resolved 17 July 2020
Resolution: New flares on board.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 November 2019 Resolved
Remove stray wires at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 18 November 2019
Resolution: Installed covering for dead end wires.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 8 November 2019 Resolved
Replace port center window at operating station. Crack in window is impeding visibility.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 1 December 2020
Resolution: replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 8 November 2019 Resolved
Repair/Replace catch on forward hatch cover.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 18 November 2019
Resolution: repaired
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 8 November 2019 Resolved
Repair/replace aft bilge alarm. Tested during inspection and it was not working, no audible or visual at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2019
Resolved 18 November 2019
Resolution: installed and operational
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 8 November 2019 Resolved
Provide cover plate on engine (clutch housing).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2019
Resolved 18 November 2019
Resolution: installed
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 29 August 2018 Resolved
Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V) and no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 18 March 2019
Resolution: The vessels proper name is R/V JOHN DEMPSEY. Deficiency issued in error.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 1 March 2018 Resolved
Inspect Halon system. Bottle was partially discharged and will need to be re-charged. A no-sail item was generated. Will need to be inspected and charged prior to taking on passengers. A control measure was generated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2018
Resolution: System charged and inspected.
Engineering › Bilge Water Management System › Piping
Issued 1 March 2018 Resolved
Repair engine room bilge suction pipe. Pipe has a hole in it. A control measure was generated. Operator understands that prior to taking passengers the pipe will have to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 25 April 2018
Resolution: pipe repaired
Electrical › Lighting (service) › Lighting Fixture
Issued 1 March 2018 Resolved
Repair light fixture in lazerate.
Condition: Improper/Lack of Maintenance
Due 1 April 2018
Resolved 25 April 2018
Resolution: light repaired.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 1 March 2018 Resolved
Provide MMC for Capt.
Due 1 April 2018
Resolved 25 April 2018
Resolution: MMC provided
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 1 March 2018 Resolved
Add crew member to random drug testing program.
Due 1 April 2018
Resolved 25 April 2018
Resolution: member added.
Navigation › Collision/Grounding Avoidance › Radar
Issued 1 March 2018 Resolved
Prove operation of Marine Radar
Due 1 April 2018
Resolved 25 April 2018
Resolution: radar operated.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 March 2018 Resolved
Repair flood light STBD. Light is located on the AFT STBD corner of the cabin.
Due 1 April 2018
Resolved 25 April 2018
Resolution: light repaired.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 July 2017 Resolved
Replace all batteries in float lights.
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: Batteries replaced.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 July 2017 Resolved
Provide L/S maintenance log
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: log generated
Communications › Audible Communications › Bell
Issued 11 July 2017 Resolved
Install bell
Due 11 August 2017
Resolved 14 July 2017
Resolution: bell installed
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 July 2017 Resolved
Provide new start batteries for generator and MDE.
Due 11 August 2017
Resolved 14 July 2017
Resolution: batteries installed.
Lifesaving › Lifefloat › Markings
Issued 11 July 2017 Resolved
Label life floats with vessel name.
Due 11 July 2017
Resolved 14 July 2017
Resolution: life float labeled.
Construction/Loadline › Structures › Ventilators
Issued 11 July 2017 Resolved
Secure port vent cover on cabin
Due 11 August 2017
Resolved 14 July 2017
Resolution: vent cover secured.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 July 2017 Resolved
Repair navigation light.
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: light repaired
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 11 July 2017 Resolved
provide one flashlight.
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: installed.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 11 July 2017 Resolved
Install bonding wire.
Condition: Improper/Lack of Maintenance
Due 14 July 2017
Resolved 14 July 2017
Resolution: wire installed.
Engineering › Steering Gear System › Ram
Issued 11 July 2017 Resolved
adjust bolts on steering gear ram
Condition: Improper/Lack of Maintenance
Due 11 August 2017
Resolved 14 July 2017
Resolution: Bolts tightened
Communications › Alarms/Indicators › High Water Alarm
Issued 11 July 2017 Resolved
adjust high water alarm. Bolt restricting lever
Condition: Improper Installation
Due 11 August 2017
Resolved 14 July 2017
Resolution: High water alarm lever moved.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 March 2016 Resolved
Provide valid COD.
Due 15 April 2016
Resolved 2 February 2017
Resolution: Valid COD provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 March 2016 Resolved
Repair stern light prior to operating at night or reduced visibility.
Action required: 705 - Other - as specified
Resolved 2 June 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 March 2016 Resolved
Provide asprin and eye-wash for first aid kit.
Due 8 May 2016
Resolved 2 June 2016

Ownership record