Records from 2016 to 2026. Most recent: inspection, 28 May 2026.
Inspection history · 17
28 May 2026
PSC B
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8376710
5 May 2026
PSC A · COC-CVE Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8356588
1 June 2025
PSC A · COC-CVE Annual
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8144960
23 February 2025
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8087036
22 February 2025
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8083015
29 December 2024
PSC B · COC-CVE Quarterly · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8050530
1 June 2024
COC-CVE Annual · PSC A · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7914544
3 March 2024
PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7871899
30 December 2019
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6877743
23 December 2019
Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6877977
1 January 2019
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6603909
19 June 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6449794
2 February 2018
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6348174
28 December 2017
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6329926
30 December 2016
COC-CVE Annual · Deficiency Check · Ballast Water Examination · ISPS II Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6063005
29 December 2016
Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6063364
8 March 2016
ISPS II Exam · COC-CVE Quarterly · NPV Safety Exam · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5822886
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 5 May 2026
Resolved
Every crew member with assigned emergency duties shall
be familiar with these duties before the voyage begins.
During abandon ship drill aft stairwell had members unable
to perform required duties. 74 SOLAS 20 III/19.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 18 May 2026
Resolution: Recieved proof of training held by vessel for entire crew.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 May 2026
Resolved
In passenger ships, doors other than power-operated
watertight doors, shall be so arranged that positive closure is assured in case of fire in the space, by power-operated
closing arrangements or by the provision of self-closing
doors capable of closing against an inclination of 3.5
opposing closure and having a fail-safe hook-back facility,
provided with a remotely operated release device. Fire
doors IID-29, IID-20A, IID-29C, SD OS are not fully closing
when activating release. 74 SOLAS 81 Amend II-2/11.2.3
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 5 May 2026
Resolution: Doors were repaired before PSCO departed from ship.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 May 2026
Resolved
The speed of door closure shall, if necessary, be controlled
so as to prevent undue danger to persons. Fire doors LDOS,
PHIS, EX 105, 4D 60, Citadel door 36, all close rapidly
presenting risk. 74 SOLAS 81 II-2/30.4
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 5 May 2026
Resolution: Doors were repaired before PSCO departed from ship.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 May 2026
Resolved
Furniture in the corridors and stairway enclosures shall be kept to a minimum. Forward stair on deck 5 has storage
cabinets installed in the stairway enclosure. 74 SOLAS 81 Amend II-2/34.6.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2026
Resolved 22 May 2026
Resolution: Provided class report removing all unallowed items stored in stairways.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 May 2026
Resolved
Above the bulkhead deck there shall be at least two means of
escape from each main vertical zone or similarly restricted
space or group of spaces at least one of which shall give
access to a stairway forming a vertical escape. Casino
Office has one identified escape route. 74 SOLAS 81 Amend II-2/28.1.2
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2026
Resolved 22 May 2026
Resolution: Recieved class report stating Casino Office was found acceptable as falling into the correct group of spaces.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 May 2026
Resolved
Where the contents and use of a space are such that there is a doubt as to its classification for the purpose of this regulation, it shall be treated as a space within the relevant category having the most stringent boundary requirements. Ship cannot provide a space categorization plan or clarification for the following spaces used for storage: lobby area between cryoconverter and watertight door 12, and sewage land greywater treatment room. Spaces were found with
storage of combustable material and no fixed firefighting. 74 SOLAS 81 amend II-2/ 26.2.2
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2026
Resolved 22 May 2026
Resolution: Class report provided evidence that combustible materials have all been removed from both spaces.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 30 December 2024
Resolved
The arrangements for the storage, distribution and utilization of oil used shall be such as to ensure the safety of the ship and persons onboard. Every oil fuel pipe which if damaged would allow oil to escape from a storage tank shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire. The pneumatic remote shut off valve on the emergency generator fuel oil tank was not capable of remote operation.
74 SOLAS 97 II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 December 2024
Resolved 30 December 2024
Resolution: Crewmembers onboard fixed the shut off valve to close properly. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 December 2024
Resolved
Fire doors in main vertical zone bulkheads and stairway enclosures, other than power-operated watertight doors and those which are normally locked, shall be self-closing type. Crew area stairway No. 2 door, 4D 23 self-closing device did not fully close door when opened. Workshop escape route stairway door to engine control room self-closing device did not fully close door when opened.
Action required: 15 - Rectify deficiencies by next port
Due 10 January 2025
Resolved 30 December 2024
Resolution: Watertight door corrected to fully close on scene.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 January 2019
Resolved
0799/10c: Indication must be provided at fire control panel in the continuously manned central control station whether each remote-controlled door is closed. When testing door 73A, the indicator registered the door as open when the door was closed. SOLAS 74(1997 Cons.) Chapter II-2, Reg. 42-1.4.2.
Action required: 705 - Other - as specified
Resolved 1 January 2019
Resolution: Contact for FSD was repaired. Indicator light was reset on panel in control station in the bridge.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 January 2019
Resolved
0725/10c: Passenger ships carrying more than 36 passengers shall be equipped with an automatic sprinkler in all service spaces. In section valve areas and fan room, had boxes and other combustible materials stored. SOLAS 74 (1997 Cons.) Chapter II-2, Reg. 36.2.
Action required: 705 - Other - as specified
Resolved 1 January 2019
Resolution: Boxes and other combustible materials were removed from sectional valve no. 13, closet and fan motor room on Deck 8.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 January 2019
Resolved
0510/10c: Where ventilation systems penetrate decks precautions shall be taken in addition to 18.1.1 and 30.5 to reduce the likelihood of smoke and hot gases passing through the system. Ventilation in engine room workshop would not close and does not prevent passage of smoke and hot gases. SOLAS 74 (1997 Cons.) Chapter II-2, Reg. 32.1.3.
Action required: 705 - Other - as specified
Resolved 1 January 2019
Resolution: Directional ventilation covers were replaced to as original prior to USCG departure.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 31 December 2017
Resolved
1. 1740/ 40b: Whenever a defect is discovered which substantially affects the integrity of the ship or the efficiency of its equipment covered by this annex the master or owner of the ships shall report at the earliest opportunity to the administration. While examining the engine room, found that oil content meter was missing for oily water separator No. 1. MARPOL ANNEX I Reg 6, 4.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 February 2018
Resolution: Recieved class report to attest to repair.
Fire Fighting › Firemans Outfit › Gloves
Issued 31 December 2017
Resolved
2. 0735/ 40b: Personal equipment shall consist of the following; 1. Protective clothing of material to protect the skin from the heat radiating from the fire and from burns and scalding by steam. Fire team member’s firefighter’s outfit was found during fire drill to have gloves of torn and wasted condition. FSS CODE 2007 CH 3, 2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 February 2018
Resolution: Recieved class report to attest to repair
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 31 December 2017
Resolved
3. 0715/ 40b: Detectors shall be operated by heat, smoke or other products of combustion, flame, or any combination of factors. Multiple detectors found inoperable. SOLAS 1981 REG 13/1.11
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 2 February 2018
Resolution: Recieved class report and verified operation onboard
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 December 2017
Resolved
4. 0910/ 10c: Fire doors in main vertical zone bulkheads and stairway enclosures shall be of the self closing typw capable of closing against an inclination of 3.5 degrees opposing closure. Numerous fire doors found to not fully close. SOLAS 1981 REG 30/4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2017
Resolved 31 December 2017
Resolution: Vessel was able to fix fire doors that were not able to close properly before USCG departure from vessel.
Personnel › Training › Crisis Management/Human Behaviour
Issued 30 December 2016
Resolved
0220 Prior to being assigned shipboard duties on board passenger ships, seafarers shall have completed training required by regulation V/2. Officers do not have training evidence for Crowd Management or Crisis Management as required by V/2. STCW (2010) CH. V Reg. V/2.4 and V/2.5 40b
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 December 2016
Resolved 4 January 2017
Resolution: Recieved officer seaman's book with required training endorsement.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 8 March 2016
Resolved
0725 - Fixed Fire Extinguishing Installation - Any required automatic sprinkler shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. Over eighty-nine sprinkler heads were identified that are unable to operate properly because they are blocked by overheard paneling. 74 SOLAS (1997 Cons) II-2 / 12.3
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2016
Resolved 9 March 2016
Resolution: The vessel's crew unobstructed the sprinkler heads allowing for the designed spray pattern to be achieved.
Lifesaving › Lifeboat › Propeller Shaft
Issued 8 March 2016
Resolved
0610 - Lifeboats - Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The lifeboat required a crewmember to continually douse the propeller shaft with water in order to prevent overheating. 74 SOLAS (2014 Cons) III / 20.2
Action required: 17 - Rectify deficiencies prior to departure
Due 8 March 2016
Resolved 8 March 2016
Resolution: Number 8 lifeboat was repaired and is operational.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 March 2016
Resolved
2035 – Fire Control Plan - In all ships general arrangement plans shall be permanently exhibited, plans shall be kept up to date, any alterations being recorded thereon as soon as practicable. The fire control plan does not show an additional general, engine, and chemical material cargo storage room located within the sewage room. 74 SOLAS (2001 Cons) II-2 / 20.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 April 2016
Resolved 20 January 2017
Resolution: Verified fire control plan shows (sewage room) Pump room No. 1 in present state accurately.
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 8 March 2016
Resolved
0960 - Means of Escape - Furniture in stairway closures shall be limited to seating. It shall be fixed, limited to six seats on each deck in each stairway enclosure, and shall not restrict the passenger escape route. Aft stairways on decks 6 and 11 contained multiple non-fixed display tables. 74 SOLAS (1997 Cons) II-2 / 41-2.4.10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 April 2016
Resolved 8 March 2016
Resolution: Non-fixed display tables were removed from aft stairways on decks 6 and 11.
Engineering › Steering Gear System › Ram Seal
Issued 8 March 2016
Resolved
0750 – Fire Prevention - Steering gear assembly is modified to capture excessive hydraulic leak of ram cylinders and results in the open storage of hydraulic oil in buckets beneath the assembly. 74 SOLAS (1997 Cons) II-2 / 15.4. See Form B for Complete Details.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 April 2016
Resolved 30 December 2016
Resolution: Received confirmation letter from Japan Government for deficiency rectification and verified during inspection.
Personnel › Training › Passenger Safety
Issued 8 March 2016
Resolved
2025 - Abandon Ship Drills - Multiple guides posted on fore and aft stairways were unable to explain passenger mustering procedures during the abandon ship drill. Initial crewman posted as in charge of lifeboats 4 and 7 were unable to operate survival craft and launching arrangements. 74 SOLAS (2014 Cons) III / 10.2, 3. SEE FORM B FOR COMPLETE DETAILS.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 April 2016
Resolved 30 December 2016
Resolution: Received confirmation letter from Japan Government for deficiency rectification and verified during inspection.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 8 March 2016
Resolved
2535 - Development of Plans for Shipboard Ops - Every company should develop, implement, and maintain a safety management system. PSCO discovered objective evidence supported by the above deficiencies that the company has failed to implement an effective safety management system. Recommend external audit. 74 SOLAS (2009 Cons) IX / 3.1 ISM Code 1.4
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 30 December 2016
Resolution: Received confirmation letter from Japan Government for deficiency rectification and verified during inspection.
Fire Fighting › Automatic Sprinkler System › Power Sources
Issued 8 March 2016
Resolved
0725 - The sprinkler systems operation manual outlined the operation sequence of the system. The crew bled off the pressure from the fresh water supply tank, the salt water pump should have actuated at 6 kgf/cm^2 but it did not. The salt water pump control panel was not set-up for automatic operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2016
Resolved 9 March 2016
Resolution: The crew set the salt water pump control panel up for auto operation. The system’s operation was verified.