MAURY USCG vessel records Sign in
← All vessels

SEA SPRAY

SEA SPRAY is a 1990 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1998, most recently in June 2025, along with 60 deficiencies.

Records from 1998 to 2025. Most recent: inspection, 4 June 2025.

Built
1990
Last inspected
4 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF4251
351686
Flag
UNITED STATES
367640130
Maury page id
psix-351686

Inspections, by type

…with no type recorded2
Years with a record 24 calendar years (1998–2025)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)51.0 ft × 16.0 ft × 5.0 ft
Registered tonnagegross 27 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSULLIVAN BOAT WORKS · POINT HARBOR, NC, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMONTAUK, NY
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 7 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Simplified, Gross Ton
21 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH6641MMSI 367640130 · active · compulsorily equipped · granted 31 July 2024, expires 10 September 2034
WCY2273MMSI not assigned · expired · compulsorily equipped · granted 17 March 1998, cancelled 17 May 2008
WAS6165MMSI not assigned · expired · voluntarily equipped · granted 10 May 1994, cancelled 11 July 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

4 June 2025 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8140553
17 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8112942
15 August 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7980340
9 August 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7763273
24 April 2023 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7674811
18 August 2022 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7519563
14 June 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7225036
8 April 2021 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7170384
5 June 2020 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6915131
10 August 2019 Type not recorded
No type recorded · USCGC STEELHEAD (WPB 87324) · USCG East District (CGD-E) · Activity 6783152
11 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6696212
20 March 2019 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6634105
17 April 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6379274
22 July 2017 Type not recorded
No type recorded · USCGC ALBACORE (WPB 87309) · USCG Northeast District (CGD-NE) · Activity 6256778
14 June 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6174744
15 March 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6105975
14 June 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5907474
27 October 2014 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5013326
13 May 2014 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4856836
23 December 2010 Hull Examination · Internal Structural Exam · Administrative Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3913820
20 February 2009 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3420851
22 October 2008 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3349304
7 August 2008 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3285235
30 March 2007 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2898469
23 May 2006 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2657862
11 May 2006 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2643997
11 July 2005 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2449932
17 May 2005 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2358915
19 January 2005 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2276974
26 May 2004 Annual Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2078528
29 May 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1787882
16 May 2003 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2126102
14 June 2002 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1629821
23 May 2002 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1618497
15 June 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1065597
30 May 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1065703
30 April 2001 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1391578
18 May 2000 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 818624
8 May 2000 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1421862
12 May 1999 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 812546
14 July 1998 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1128496
15 May 1998 Hull Examination · Initial Certification
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1473448

Deficiency record · 60

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2025 Resolved
Provide 4 additionally adult type 1 PFD's prior to carrying more than 32 total POB.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 June 2025
Resolved 4 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 June 2025 Resolved
Provide 3 additional night time flares, currently only have 09 total flares all of which are night. (cleared 04JUN25)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2025
Resolved 4 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2025 Resolved
Provide CG approved ring buoy float light, O/O had a lifejacket light with floatation attached , the light was water activated but not the appropriate style #goodeffort (cleared 04JUN25)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2025
Resolved 4 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 June 2025 Resolved
Provide new 10:BC and 2:A fire extinguishers. Currently fire servicing company replaced 10:BC with a 5:BC and 2:A was not available for inspection (cleared 04JUN25)
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2025
Resolved 4 June 2025
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 August 2023 Resolved
Mid ships visual bilge alarm inop.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2023
Resolved 31 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 August 2023 Resolved
Vessel only had 08 flares; required 12.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 September 2023
Resolved 10 August 2023
Resolution: New flares purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 August 2023 Resolved
Vessel was missing required waterlight for lifering. Restricted to daylight ops only.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2023
Resolved 10 August 2023
Resolution: New waterlight purchased.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 August 2023 Resolved
Add lines to the fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2023
Resolved 10 August 2023
Resolution: Lines attached.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 August 2023 Resolved
Vessel did not have light list, coast pilot, or tide tables.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2023
Resolved 31 August 2023
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 August 2023 Resolved
Missing logged drills and epirb checks.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 September 2023
Resolved 10 August 2023
Electrical › Electric Supply System (service) › Cable
Issued 17 April 2018 Resolved
Update line drawing for new DC electrical install
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 26 April 2018
Resolution: MI attended cleared outstanding
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 17 April 2018 Resolved
Update common block-elec. within machinery space
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 April 2018
Resolved 26 April 2018
Resolution: MI attended cleared outstanding
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 17 April 2018 Resolved
Update fuse panel installations under Nav. Sta
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 April 2018
Resolved 26 April 2018
Resolution: MI attended vessel cleared outstanding
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 17 April 2018 Resolved
Properly secure DC leads to Nav. Sta that run thru bilges
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 April 2018
Resolved 26 April 2018
Resolution: MI attended and cleared outstanding
Engineering › Steering Gear System › Rudder
Issued 17 April 2018 Resolved
Properly adjust steering pintal and resecure
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 April 2018
Resolved 26 April 2018
Resolution: MI attended to clear outstanding
Lifesaving › Lifefloat › Retroreflective Material
Issued 15 June 2016 Resolved
Replace retroreflective tape on life floats and add retroreflective tape to lifering buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 19 October 2016
Resolution: Retroreflective tape added to life floats and ring life buoy.
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 15 June 2016 Resolved
Seal vents for blowers going to engine room. Blowers were used for cooling and are no longer in use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 19 October 2016
Resolution: Blower ducts on forward and aft engine cover were sealed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 June 2016 Resolved
Remove dead end wiring from engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 19 October 2016
Resolution: Dead end wiring from engine room removed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 June 2016 Resolved
Renew eye wash and asprin in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 19 October 2016
Resolution: New eye wash and asprin added to vessel first aid kit.
Engineering › Fuel Oil Service System › Gauge
Issued 15 June 2016 Resolved
Make jacket water discharge temperature gauge and lubricating oil pressure gauge readily visible/operational at the operating station.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 July 2016
Resolved 19 October 2016
Resolution: Jacket water temperature gauge and lubricating oil pressure gauge installed at operating station and operationally tested.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 13 May 2014 Resolved
Provide after hours post causality drug testing.
Due 13 May 2014
Resolved 23 May 2014
Resolution: Received email proof.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2014 Resolved
Provide aspiran for first aid kit.
Due 13 June 2014
Resolved 30 May 2014
Resolution: Received email proof.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2014 Resolved
Provide a complete first aid kit.
Due 30 May 2014
Resolved 30 May 2014
Resolution: Received email proof.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 May 2014 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 30 May 2014
Resolved 30 May 2014
Resolution: Received email proof.
Lifesaving › Lifefloat › Painter
Issued 13 May 2014 Resolved
Install proper length sea painter.
Due 13 May 2014
Resolved 30 May 2014
Resolution: Received email proof.
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 13 May 2014 Resolved
Repair or replace spot light.
Due 30 May 2014
Resolved 30 May 2014
Resolution: Received email proof.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 13 May 2014 Resolved
Repair fixed fire fighting system alarm wiring.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 May 2014
Resolution: Repaired on the spot.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 May 2014 Resolved
Provide proper installation of automatic engine shutdown system with integrated alarm horn and discharge light and override switch for engine restarting for pre eng fire fighting system.
Action required: 705 - Other - as specified
Due 1 November 2014
Resolved 27 October 2014
Resolution: Inspected installation of approved pre-engineered clean agent system. Installation and operation sat.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 13 May 2014 Resolved
Provide radio station auth cert with vessel name and official number.
Due 30 May 2014
Resolved 7 October 2014
Resolution: Received email copy of Radio Station Auth document.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 13 May 2014 Resolved
Master to provide FCC Operators License.
Due 30 May 2014
Resolved 21 May 2014
Resolution: Received email proof.
Stability › Watertight Integrity › General
Issued 13 May 2014 Resolved
Repair frozen wth fwd of eng room.
Due 23 May 2014
Resolved 23 May 2014
Resolution: Hatch repaired
Communications › Radio Communications › EPIRB
Issued 23 December 2010 Resolved
Provide update data for new EPIRB recently purchased & prove new EPIRB is properly registered.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 May 2011
Resolution: EPIRB DATA PROVIDED
Stability › Incline Test › General
Issued 23 December 2010 Resolved
USCG is currently reviewing the vessel's past SSTs and the current stability status of the vessel. The fixed canopy over the aft deck is no longer aboard and vessel is back to her original design deckplan. Vessel shall not operate w/ more than 25 persons aboard until the stability has been successfully approved by USCG.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 25 January 2011
Resolution: OCMI is requiring a new SST utilizing the new AAPPW of 185#/ person.
Documentation › Certificates/Documents › Stability Letter
Issued 23 December 2010 Resolved
Vessel restricted to Partially Protected routes and not more than 25 total persons until a valid stability letter is issued by the OCMI.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 4 August 2011
Resolution: Ltr drafted for OCMI signature.
Stability › Incline Test › General
Issued 23 December 2010 Resolved
After review of the vessel's current stability data and in consideration of the 14 December 2010 increase in the average assumed per passenger weight (AAPPW) the [name withheld] is requiring that the vessel conduct a satisfactory simplified stability test (SST) prior to carrying more than 25 total persons.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 March 2011
Resolved 5 May 2011
Resolution: SST witnessed and vessel determined to be satisfactory for 36 persons @ 185# on partially protected routes.
Construction/Loadline › Structures › Scupper
Issued 16 December 2010 Resolved
Repair tear in FRP sheathing on upper panel of fwd freeing port on port side. Sending a photo of the repair progress & completion will suffice to prove compliance w/ repair requirement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2011
Resolution: Repaired w/ epoxy resin and 3 M 5200 marine urethane adhesive.
Engineering › Bilge Water Management System › Pump
Issued 16 December 2010 Resolved
Submersible electric pump aft of MDE stuck in on position. Locate switching fault & repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 December 2010
Resolution: Float switch replaced.
Documentation › Certificates/Documents › FCC SSL
Issued 7 August 2008 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 1 September 2009
Resolution: The vessel representative did not complete an annual inspection in 2009 and the COI was revoked.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 August 2008 Resolved
Provide proof of servicing for all fire fighting equipment IAW 46 CFR 176.810 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2009
Resolution: Provided proof of servicing for all fire fighting equipment IAW 46 CFR 176.810.
Lifesaving › Lifefloat › Lifeline
Issued 7 August 2008 Resolved
Connect all lifefloats to painter IAW 46 CFR 180.137(e) within 14 days.
Action required: 705 - Other - as specified
Due 21 August 2008
Resolved 20 February 2009
Resolution: Connected all lifefloats to the painter IAW 46 CFR 180.137(e).
Communications › Radio Communications › EPIRB
Issued 7 August 2008 Resolved
Provide proof of NOAA registration of EPIRB IAW 46 CFR 185.728. Vsl restricted to 3 nm from shore until cleared.
Action required: 705 - Other - as specified
Resolved 20 February 2009
Resolution: Provided proof of NOAA registration of EPIRB.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 May 2006 Resolved
Prove hydro date on all portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 23 May 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Crankcase
Issued 11 May 2006 Resolved
Repair L/O leak on filter assy.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 23 May 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 May 2006 Resolved
Provide covers for the battery terminals.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 23 May 2006
Engineering › Steering Gear System › Trick Wheel
Issued 11 May 2006 Resolved
Prove proper operation of the emergency steering tiller.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 26 May 2006
Resolved 23 May 2006
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 17 May 2005 Resolved
Provide proof of crew enrollment in USCG approved drug testing program.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2005
Resolution: Proof of crew enrollment in drug testing program was provided via fax.
Lifesaving › Hand Flares › Expired
Issued 17 May 2005 Resolved
Provide three new red hand flares and three new hand orange smokes to meet the requirements of the COI. Vessel is restricted to lakes bays and sounds route or less.
Due 17 June 2005
Resolved 20 May 2005
Resolution: The receipt for the purchase of six hand red flares and six orange smokes was faxed to the MSO.
Communications › Radio Communications › EPIRB
Issued 17 May 2005 Resolved
Install a hydrostatic release for EPIRB. Vessel is restricted to three miles from shore.
Due 17 June 2005
Resolved 14 June 2005
Resolution: Vessel owner purchased and installed new hydrostatic release.
Lifesaving › Lifefloat › Markings
Issued 17 May 2005 Resolved
Renew retro reflective tape on FWD lifefloat. Vessel is restricted to warm water operation.
Condition: Unknown
Due 17 June 2005
Resolved 17 May 2005
Resolution: Retro reflective tape on lifefloat renewed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 May 2005 Resolved
Install a 60 foot life line not less than 5/16" in diameter for life rung buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2005
Resolved 17 May 2005
Resolution: New 60 foot life line installed on ring buoy.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 17 May 2005 Resolved
Attach lanyard to hatch cover.
Due 17 June 2005
Resolved 17 May 2005
Resolution: Vessel owner installled lanyard on hatch cover.
Construction/Loadline › Hull › Keel
Issued 11 February 2005 Resolved
A 6' shallow crack was found along the stbd keel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2005
Resolution: Crack was repaired.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 26 May 2004 Resolved
Provide two water lights for life floats.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2004
Resolved 2 June 2004
Lifesaving › Liferaft Equipment › Paddle
Issued 26 May 2004 Resolved
Stencil vessel name on life float paddles before 27 June 2004.
Due 26 June 2004
Resolved 2 June 2004
Lifesaving
Issued 30 April 2001 Resolved
REPLACE LINES ON LIFEFLOATS AS NEEDED.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Lifesaving
Issued 30 April 2001 Resolved
RE-NEW HYDRO RELEASE ON EPIRB. VESSEL RESTRICTED TO LAKES BAYS AND SOUNDS UNTIL IT COMPLIES WITH THIS REQUIREMENT.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Documentation
Issued 30 April 2001 Resolved
PROVIDE AND POST STABILITY LETTER.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Construction/Loadline
Issued 15 May 1998 Resolved
PROVIDE VISUAL INDICATOR FOR BILGE PUMPS. IAW 46CFR 182.520.
Condition: Unknown
Due 22 June 1998
Resolved 22 June 1998
Lifesaving
Issued 15 May 1998 Resolved
PROVIDE AN FCC TYPE ACCEPTED CATEGORY 1, 406 MHz EPIRB, INSTALLED TO AUTOMATICALLY FLOAT FREE AND ACTIVATE. 46CFR 180.64. VESSEL IS RESTRICTED TO NOT MORE THAN THREE (3) MILES OFF SHORE.
Condition: Unknown
Due 15 May 1998
Resolved 15 May 1998
Fire Fighting
Issued 15 May 1998 Resolved
INSTALL FIXED FIRE FIGHTING SYSTEM WITHIN THIRTY (30) DAYS UPON RECEIPT OF APPROVED PLANS. VESSEL IS RESTRICTED TO LBS ROUTE UNTIL SATISFACTORY INSTALLATION OF APPROVED SYSTEM.
Condition: Unknown
Due 15 May 1998
Resolved 15 May 1998

Ownership record