Records from 1992 to 2001. Most recent: inspection, 19 November 2001.
Inspection history · 22
19 November 2001
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 295649
21 March 2000
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 275881
1 February 2000
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 274000
31 January 2000
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 176504
17 May 1999
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 428746
30 March 1999
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 723963
14 March 1999
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 28988
14 March 1999
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 426645
12 April 1998
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 414726
25 March 1997
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 401835
14 February 1997
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 399439
21 August 1996
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 394437
24 July 1996
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 393550
1 February 1996
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 387576
19 January 1996
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 386319
13 November 1995
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 685593
1 November 1995
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 383687
12 October 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 383614
5 January 1995
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 685594
4 January 1995
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 373966
21 May 1993
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 685595
18 August 1992
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 452798
Lifesaving
Issued 21 March 2000
Resolved
GEAR BEING STOWED AROUND ELECTRIC PANEL IN ENGINE ROOM. SEE SOLAS 74/78 I REG. 11(a).
Condition: Unknown
Due 22 March 2000
Resolved 29 March 2000
Engineering
Issued 21 March 2000
Resolved
EXPOSED EXHAUST PIPES ON MAIN ENGINE. NEED TO BE COVERED. SEE SOLAS 74/78_x001C_ I REG. II.A
Condition: Unknown
Due 22 March 2000
Resolved 29 March 2000
Lifesaving
Issued 1 February 2000
Resolved
IMMERSION SUITS DETERIORATED REPLACEMENT REQUIRED SEE SOLAS 74/78 III REG 27/3.2.
Condition: Unknown
Due 4 February 2000
Resolved 4 February 2000
Lifesaving
Issued 1 February 2000
Resolved
MSD SYSTEM INOPERABLE. SEE 33 CFR 159.7.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Fire Fighting
Issued 1 February 2000
Resolved
EMERGENCY FIRE PUMP DOES NOT PRODUCE ENOUGH WATER PRESSURE FOR TWO JETS OF WATER. SEE SOLAS 74 PART D REG 52 b(ii).
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Electrical
Issued 17 May 1999
Resolved
PROVIDE GLOBES FOR DROP LIGHTING IN ENGINE ROOM OR REMOVE DROP LIGHTING WITHOUT GLOBES FROM SERVICE.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Lifesaving
Issued 17 May 1999
Resolved
REMOVE OR PROPERLY STOW BOXES, GARBAGE, AND COMBUSTIBLE MATERIAL IN ENGINE ROOM.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Accommodation/Occupational Safety
Issued 14 March 1999
Resolved
TOILET IN HOSPITAL SPACE INOPERATIVE.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Construction/Loadline
Issued 14 March 1999
Resolved
ENGINE ROOM HATCH COVER COAMING WASTED THROUGH.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Electrical
Issued 14 March 1999
Resolved
EMBARKATION LIGHTING INOPERATIVE.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Construction/Loadline
Issued 14 March 1999
Resolved
STEERING GEAR ROOM WATER-TIGHT DOOR INOPERATIVE.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Engineering
Issued 14 March 1999
Resolved
TWO (OF 4) STARTING AIR COMPRESSORS INOPERABLE.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Construction/Loadline
Issued 14 March 1999
Resolved
HOLE IN SHAFT ALLEY OVERHEAD INTO STEERING GEAR ROOM.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Fire Fighting
Issued 14 March 1999
Resolved
PORTABLE EXTINGUISHER BRACKET IN ENGINE ROOM BROKEN, STARBOARD SIDE AFT LOWER LEVEL.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Lifesaving
Issued 14 March 1999
Resolved
STARBOARD LIFEBOAT HOLED IN THREE PLACES.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Electrical
Issued 14 March 1999
Resolved
GROUND FAULT IN EMERGENCY LIGHTING CIRCUIT INDICATED.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Accommodation/Occupational Safety
Issued 14 March 1999
Resolved
FOOD STORED IN PAINT LOCKER.
Condition: Unknown
Due 15 March 1999
Resolved 18 March 1999
Lifesaving
Issued 14 March 1999
Resolved
GENERAL ALARM IN ENGINE SPACES INOPERATIVE.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Construction/Loadline
Issued 14 March 1999
Resolved
WEATHER TIGHT DOOR FROM AFT DECK PORT SIDE INTO GALLEY NOT WEATHER TIGHT.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Lifesaving
Issued 14 March 1999
Resolved
VESSEL FAILED TO REPORT A HAZARDOUS CONDITION (LOSS OF MAIN PROPULSION) TO NEAREST COAST GUARD OFFICE.
Condition: Unknown
Due 14 March 1999
Resolved 18 March 1999
Engineering
Issued 14 March 1999
Resolved
VESSEL FAILED TO REPORT MARINE CASUALTY, LOSS OF MAIN PROPULSION, TO NEAREST COAST GUARD OFFICE.
Condition: Unknown
Due 14 March 1999
Resolved 18 March 1999
Engineering
Issued 14 March 1999
Resolved
FUEL TANK VENT VALVE BROKEN, PORT AND STARBOARD SIDE MAIN DECK.
Condition: Unknown
Due 15 March 1999
Resolved 18 March 1999
Engineering
Issued 14 March 1999
Resolved
NUMEROUS WASTED SALT WATER PIPING THROUGHOUT ENGINE ROOM.
Condition: Unknown
Due 29 March 2000
Resolved 29 March 2000
Navigation
Issued 14 March 1999
Resolved
RPM INDICATORS ON BRIDGE WINGS INOPERATIVE.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Lifesaving
Issued 14 March 1999
Resolved
PROVIDE RING LIFE BOUYS IAW SOLAS.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Construction/Loadline
Issued 14 March 1999
Resolved
STARBOARD SIDE WEATHER TIGHT DECK DOOR AT GALLEY NOT WEATHER TIGHT.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Fire Fighting
Issued 14 March 1999
Resolved
EMERGENCY FIRE PUMP INOPERABLE.
Condition: Unknown
Due 15 March 1999
Resolved 30 March 1999
Lifesaving
Issued 14 February 1997
Resolved
REMOVE PORTABLE STORAGE SHEDS PLACED NEXT TO PORT AND STARBOARD INFLATABLE LIFERAFTS.
Condition: Unknown
Due 26 March 1997
Resolved 26 March 1997
Accommodation/Occupational Safety
Issued 24 July 1996
Resolved
REMOVE SHIP'S STORES FROM HOSPITAL SPACE.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Documentation
Issued 24 July 1996
Resolved
RECORD TESTING OF SHIP'S EMERGENCY BATTERIES IN SHIP'S LOG PRIOR TO ENTRY INTO PORT AS REQUIRED BY 33CFR164.25
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Unknown
Issued 24 July 1996
Resolved
REPAINT LOADLINE IN CONTRASTING COLOR ON HULL AS REQUIRED BY ILLC 66 ANNEX I/8.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Lifesaving
Issued 24 July 1996
Resolved
REPAIR STBD. EMBARKATION LIGHTING AS REQUIRED BY SOLAS 74 UNAMENDED III/19(a)(ii).
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Electrical
Issued 24 July 1996
Resolved
INSTALL LIGHT FIXTURE COVERS IN SHIP/S ACCOMODATIONS AND ENGINE ROOM AS REQUIRED BY ILO 147 ARTICLE II.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Navigation
Issued 19 January 1996
Resolved
STEERING ROOM TELEPHONE BUZZER BROKE. BRIDGE HAS NO MEANS OF CONTACTING STRG ROOM IN CASE OF EMERGENCY.
Condition: Unknown
Due 3 February 1996
Resolved 3 February 1996
Navigation
Issued 1 November 1995
Resolved
The DHARA, a vessel of over 1,600 Gross Tons, Vessel did not have on board a 1995 Tidal Current Table for American Samoa to Pago Pago Harbor.
Condition: Unknown
Due 21 August 1996
Resolved 21 August 1996
Navigation
Issued 4 January 1995
Resolved
VESSEL HAS A GROSS TONNAGE OF 2,003 AND ENTERED PAGO PAGO HARBOR, AMERICAN SAMOA, A NAVIGABLE WATERWAY OF THE U.S. WITHOUT A CURRENT TABLE COVERING THIS HARBOR.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Navigation
Issued 4 January 1995
Resolved
SUBJECT VESSEL HAS A GROSS TONS OF 2,003 AND ENTERED PAGO PAGO HARBOR, AMERICAN SAMOA, A NAVIGABLE WATERWAY OF THE U.S. WITHOUT A COAST PILOT OR TIDE AND CURRENT TABLES FOR COVERING THIS HARBOR.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995
Navigation
Issued 4 January 1995
Resolved
VESSEL HAS A GROSS TONNAGE OF 2,003 AND ENTERED PAGO PAGO HARBOR, AMERICAN SAMOA, A NAVIGABLE WATERWAY OF THE U.S WITHOUT A TIDE TABLE COVERING THIS HARBOR.
Condition: Unknown
Due 6 December 1995
Resolved 6 December 1995