MAURY USCG vessel records Sign in
← All vessels

FREJA MAERSK

FREJA MAERSK is a 2001 tank ship. The Coast Guard has recorded 63 inspections since 2001, most recently in March 2016, along with 15 deficiencies and 13 operational controls.

Records from 2001 to 2016. Most recent: inspection, 27 March 2016.

Built
2001
Last inspected
27 March 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9219276 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
DENMARK
—
Maury page id
psix-35193

Inspections, by type

…with no type recorded19
Years with a record 15 calendar years (2001–2016)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it21516 - Convention (Subpart B), Gross Ton
21516 - Regulatory (Subpart C or D), Gross Ton
7871 - Convention (Subpart B), Net Ton
7871 - Regulatory (Subpart C or D), Net Ton
39474 - Displacement, Ton
31632 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 63

27 March 2016 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5837449
21 March 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5837317
26 January 2016 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5803383
19 January 2016 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5799959
16 November 2015 ISPS II Exam · COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5764122
5 November 2015 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5758077
5 October 2014 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4999307
20 August 2014 PII Safety Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4959577
11 August 2014 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4951538
11 August 2014 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4952314
14 June 2014 COE-Dockside · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4881832
6 June 2014 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4881117
18 May 2014 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4861206
16 May 2014 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4860022
25 March 2014 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4822302
28 February 2012 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4252924
27 February 2012 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4252436
26 February 2012 COE-Dockside
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4251352
30 August 2011 NPV Safety Exam · COE-Dockside · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4127754
29 January 2011 COE-Administrative
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3935481
10 January 2011 Deficiency Check · COC-CHEM Annual · ISPS II Exam · Ballast Water Examination · COE-Dockside
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3923446
24 January 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3669214
21 January 2010 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3667280
4 January 2010 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3658083
12 December 2009 Ballast Water Examination · ISPS III Exam · COE-Dockside · COC-CHEM Renew · MARPOL Annex I Examination · MARPOL Annex VI Survey · MARPOL Annex II Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3646834
29 July 2009 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3549511
29 July 2009 COE-Administrative
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3549618
10 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3530326
10 July 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3530494
29 January 2009 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3402083
29 November 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3371093
29 November 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3372556
24 November 2008 ISPS II Exam · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3368303
24 October 2008 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3350526
5 October 2008 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3368657
16 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3208640
9 January 2008 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3127208
19 November 2007 COC-CHEM Renew · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3100805
22 January 2007 COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2859714
22 January 2007 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2860415
27 June 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2694274
10 January 2006 Random ISPS/MTSA/PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2563904
13 December 2005 Type not recorded
No type recorded · Vessel Traffic Service Houston-Galveston · USCG Heartland District (CGD-H) · Activity 2550876
9 November 2005 Ballast Water Examination · COC-CHEM Renew · ISPS III Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2529958
9 November 2005 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2531838
17 December 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2261216
17 December 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2261368
15 October 2004 COC-CHEM Annual
Type not classified · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2221376
10 June 2004 MTSA/ISPS Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2094781
17 October 2003 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1929091
17 October 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1930485
16 July 2003 Special Interest Vessel
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1875365
9 July 2003 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1841054
12 September 2002 MARPOL Annex V Examination · MARPOL Annex I Examination · Certificate of Compliance
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1676356
27 May 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1621363
1 April 2002 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1599683
18 March 2002 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1494312
5 March 2002 Security Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1491305
5 March 2002 Special Interest Vessel
Type not classified · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1492203
8 January 2002 Security Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1488882
13 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 294737
3 September 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 293396
3 September 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1074167

Deficiency record · 15

Deck/Cargo › Holds/Tanks › Tank Pressure Monitoring Device
Issued 25 March 2014 Resolved
While conducting Cargo/Deck Inspection, it was observed that cargo tank #2 Starboard pressure sensor was not working. Vessel to make proper notification to flag and class of the deficiency and rectify issues to the satisfaction of class ABS. Manual read Pressure gauge has been installed and crew will monitor the tank pressure on rounds. 30 days to rectify with class.
Action required: 705 - Other - as specified
Due 25 April 2014
Resolved 17 April 2014
Resolution: Received class documentation that pressure sensor had been replaced and working properly.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 25 March 2014 Resolved
Faulty alarm discovered within the VDR and reported to Port State Control, MSU Port Arthur and NOA. Vessel notified Class and Flag. Technician to rectify deficiency and submit report prior to vessel departing next U.S. Port which will be Houston to load. PRIOR TO VESSEL DEPARTING NEXT U.S. PORT, HOUSTON, TECHNICIAN REPORT TO USCG.
Action required: 705 - Other - as specified
Resolved 17 April 2014
Resolution: Received class documentation that VDR fixed and operating properly.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 27 February 2012 Resolved
1899- Vessel's crew has no record of or is able to demonstrate testing, inspection, and/or maintenance of the IGS (Nitrogen). Operations manual from manufacturer, found on board, explains that there should be regular maintenance/inspections. But, no records or knowledge of a procedure is available.
Due 27 February 2012
Resolved 28 February 2012
Resolution: Class (DNV) has verified there are now written procedures for inspection, testing and maintenance of the IGS (Nitrogen).
Engineering › Steam System (auxiliary) › Piping
Issued 10 January 2011 Resolved
Steam was found leaking from the piping of the #1 FFO Circulation pump located in the purifier room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 January 2011
Resolved 13 January 2011
Resolution: Pipe replaced with new one by crew. Visually inspected by class and found in order.
Electrical › Electric Generation Source (emergency) › Generator
Issued 10 January 2011 Resolved
Hydraulic oil was found leaking from the hydraulic starting system for the emergency generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 January 2011
Resolved 13 January 2011
Resolution: Piston replaced with new one by crew. Visually inspected by class and found in order.
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 24 January 2010 Resolved
Auxiliary engines for the generators are operating with reduced capabilities
Due 25 January 2010
Resolved 28 January 2010
Resolution: received class report attesting to repairs
Navigation › Piloting/Steering › Gyro Compass
Issued 10 July 2009 Resolved
The vessel Gyro Compass is not operating properly. The vessel is required to submit a tech report attesting to the proper operation of the Gyro Compass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 July 2009
Resolution: Received tech report atesting to the proper repair and operation of teh gyro. Op Con released.
Engineering › Fuel Oil Service System › Pump
Issued 29 November 2008 Resolved
Received notification of loss of propulsion due to the No. 1 Main Engine and No. 1 Generator Engine Fuel Oil Circulating Pumps had tripped and the standby No. 2 Pumps did not immediately start.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 November 2008
Resolution: Received Class Report attesting to the proper operation of the vessel''s main engines. Surveyor ran tests of the start function of the relevant pumps and found in proper operating order. Main engine was operated ahead and astern with satisfactory results.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 24 November 2008 Resolved
Incinerator has an accumulation of sludge residue leaking outside the furnace to the underside of the unit's insulation shell creating an un-necessary fire hazard. (33 CFR 151.63 (b)(3) SOLAS 74 2004 CONSOL CH. II-I Reg 26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 November 2008
Resolution: Received Class report attesting to the removal of the sludge oil residue from the underside of the incinerator.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 24 November 2008 Resolved
During the examination of the purifier room it was discovered that a transfer pump was excessively leaking fuel oil. SOLAS 74 2004 consol Ch. II-I Reg 26.1
Action required: 705 - Other - as specified
Due 9 December 2008
Resolved 1 March 2016
Resolution: Received class report attesting to the repairs and operation of the fuel oil transfer pump in the purifier room.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 24 November 2008 Resolved
Third mates Flag State endorsement does match his certificate of competence (national license). STCW 95 Ch.1 Reg 2.6.2
Action required: 705 - Other - as specified
Due 2 December 2008
Resolved 26 November 2008
Resolution: Received copy of Third mate''''s Flag State endorsement with correct number, matching national license. Deficiency has been rectified.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 19 November 2007 Resolved
During eng inspection, a plastic clinker was found mixed w/ ashes from paper and oily rags inside the incinerator. Chief Mate , 3RD Mate and the 1ST ENG have been informed on the importance of properly seperating trash on board. Crew will do a more stringent check of the trash prior to using incinerator. All ash is always discharged on shore.
Action required: 705 - Other - as specified
Due 19 November 2007
Resolved 19 November 2007
Resolution: Corrected on the spot.
Construction/Loadline › Markings › Load Line Mark
Issued 19 November 2007 Resolved
Vsl class society, Det Norske Veritas, is not permentently marked on the sides of the ship. Ship's superintedent stated that the vsl will be in drydock, APR 2008, to correct to the satisfaction of the Administration.
Action required: 705 - Other - as specified
Due 19 November 2007
Resolved 19 November 2007
Resolution: Vsl had issue documented on drydock worksheet prior to present inspection.
Pollution Prevention/Response › Prevention Equipment › Internal Cargo Transfer Capability
Issued 19 November 2007 Resolved
Incinerator brick lining crumbles when touched. Replace or repair lining.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2007
Resolved 9 January 2008
Resolution: Received classification society surveyor report completed 03JAN08. The incinerator has been temporarily repaired and the brickwork will be renewed completely during vessels next shipyard visit in May 2008.
Documentation › Certificates/Documents › IOPP Certificate
Issued 22 January 2007 Resolved
Vessel is missing slop tank capacity written on its IOPP supplement form B.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2007
Resolution: Received class survey report attesting to revision/correction of IOPP.

Ownership record