MAURY USCG vessel records Sign in
← All vessels

GENMAR NESTOR

GENMAR NESTOR is a 1990 tank ship. The Coast Guard has recorded 48 inspections since 1990, most recently in January 2005, along with 22 deficiencies and 4 operational controls.

Records from 1990 to 2005. Most recent: inspection, 10 January 2005.

Built
1990
Last inspected
10 January 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8902773 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
352102
Flag
LIBERIA
—
Maury page id
psix-352102

Inspections, by type

…with no type recorded30
Years with a record 16 calendar years (1990–2005)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it52594 - Regulatory (Subpart C or D), Gross Ton
28137 - Regulatory (Subpart C or D), Net Ton
97112 - Dead Weight, Ton
111243 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

STC 2806 Tank Barge · MISLE 45798 · 30 November 1996 · activity 28873S-25 Tank Barge · MISLE 51021 · 30 November 1996 · activity 28873LIL SUSAN S Towing Vessel · MISLE 133619 · 30 November 1996 · activity 28873

Inspection history · 48

10 January 2005 Random ISPS/MTSA/PSC
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2272274
18 September 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2198731
17 September 2004 PII Safety Exam
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2198236
16 August 2004 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2167545
29 July 2004 COC-TVE Renew
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2148291
12 June 2004 MTSA/ISPS Verification
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2101281
1 March 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2018068
7 January 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1978212
15 December 2003 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1964202
4 October 2003 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1916571
16 September 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1906101
13 September 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1904628
18 July 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1850083
10 June 2003 Security Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1814740
6 June 2003 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1811416
26 July 2002 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1652346
30 March 2001 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 288597
3 January 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 285645
3 January 2001 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1057016
7 September 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 281947
1 September 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 432684
10 October 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 80544
27 September 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 4201
6 July 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 655804
23 March 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 413937
6 March 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 100919
3 February 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 412384
18 December 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411036
30 November 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 28873
8 July 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 393052
7 June 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 392004
23 January 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 440643
12 October 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 383765
8 June 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 379269
7 December 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1424030
2 June 1994 Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1465786
27 May 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 367267
5 December 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 518054
28 November 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 482811
23 April 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 357683
12 April 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 357579
12 April 1993 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 833183
20 May 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 350920
20 May 1992 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 955030
4 June 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 344159
4 June 1991 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 924209
31 December 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 455190
23 July 1990 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1225880

Deficiency record · 22

Navigation › Piloting/Steering › Gyro Compass
Issued 17 September 2004 Resolved
Vsl was issued a Letter of Deviation to enter the Port of Corpus Christi, Texas without a properly operating gyrocompass 33CFR164.35(d). Based on the understanding that the equipment will be operational prior to leaving the port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2004
Resolution: Recieved tech report via fax confirming that repairs have been made and equipment is in good working order.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 28 July 2004 Resolved
VESSEL WAS FOUND TO HAVE (07) FOOD RATIONS IN WHICH VACUUM SEALS WERE BROKEN. TO BE CORRECTED WITHIN 30 DAYS. CITE SOLAS 74/78 CH. III/REG. 41.8.12.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2004
Resolved 13 August 2004
Resolution: Received class report. 7 new food rations now on board.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 28 July 2004 Resolved
TANK OVERFILL ALARM INDICATORS FOR THE CARGO DECK AREAS WERE NOT ABLE TO BE HEARD OR SEEN WHEN ACTIVATED. MUST BE CORRECTED WITHIN 30 DAYS. CITE 46 CFR 39.20-7(d)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2004
Resolved 13 August 2004
Resolution: Received class report. New siren and light fitted.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 28 July 2004 Resolved
TANK OVERFILL ALARM LEGEND WAS FOUND TO BE WRITTEN IN RED INSTEAD OF THE REQUIRED COLOR BLACK. MUST BE CORRECTED WITHIN 30 DAYS. CITE 46 CFR 39.20-7(d)(3)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2004
Resolved 13 August 2004
Resolution: Received class report. Alarm legend now painted black.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 28 July 2004 Resolved
THE FOLLOWING VENT FLAME SCREENS WERE FOUND TO BE NEEDING REPLACEMENT : 8C, 7C, 6C, 5C, 3C, 1C, 2P FOT(RED), AND 2P FOT(RED). MUST BE CORRECTED WITHIN 30 DAYS. CITE 46 CFR 30.10-25 AND 32.55-20(c) AND SOLAS 74/78 CH. II-2/REG.59.1.5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2004
Resolved 13 August 2004
Resolution: Received class report. All flame screens replaced with new materials.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 28 July 2004 Resolved
INADEQUATE SPAN GAS WAS PROVIDED FOR CALIBRATION OF BOTH PORTABLE AND FIXED INERT GAS ANALYZERS. MUST PROVIDE PROPER SPAN GAS(2-5% O2) WITHIN 30 DAYS. CITE SOLS 74/78 CH. II-2/REG. 62.18
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2004
Resolved 13 August 2004
Resolution: Received class report. All required span gas now provided.
Deck/Cargo › Crude Oil Washing Systems › Sensing Instrument
Issued 28 July 2004 Resolved
OIL DISCHARGE MONITORING EQUIPMENT WAS FOUND NOT TO BE WORKING PROPERLY AND NOT ABLE TO CONDUCT SELF TEST. MUST BE CORRECTED WITHIN 30 DAYS TO THE SATISFACTION OF VESSELS CLASSIFICATION SOCIETY. CITE MARPOL 73/78 ANNEX I, CH. II AND 33 CFR 157.12.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2004
Resolved 13 August 2004
Resolution: Received class report. ODME repaired and tested satisfactorily.
Engineering › Generator (propulsion-electric)
Issued 6 June 2003 Resolved
Vessel's #1 generator not in operation due to damaged armature. SOLAS 74(Amended) Chp. II-1 Reg. 40 LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2003
Resolved 18 July 2003
Resolution: Received Class report attesting to satisfactory repairs to vessel''s #1 generator.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 26 July 2002 Resolved
several spray nozzals not working on port life boat
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2002
Fire Fighting
Issued 26 July 2002 Resolved
fire drill was unsatifactory crew was slow and did not know thair dutys.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2002
Unknown
Issued 3 January 2001 Resolved
PRIOR TO THE ENTRY OF NEXT U.S. PORT, PROVE THE PROPER OPERATION OF OIL DISCHARGE MONITOR (O.D.M.E.) ODME CANNOT BE RIN OR CALIBRATED DUE TO BAD OPTICAL CABLE.
Condition: Unknown
Due 2 April 2001
Resolved 2 April 2001
Lifesaving
Issued 7 September 2000 Resolved
Lifeboat missing reflective tape._x001C_ SOLAS 74 Ammended/ChIII reg.41
Condition: Unknown
Due 7 September 2000
Resolved 8 September 2000
Electrical
Issued 7 September 2000 Resolved
Electrical juntion box for cargo pump room lighting cracked and not intrinsically safe._x001C_ 46CFR32.20
Condition: Unknown
Due 7 September 2000
Resolved 8 September 2000
Deck/Cargo
Issued 7 September 2000 Resolved
10 Flame arrestor screens for cargo tanks corroded/unsat condition._x001C_ 46CFR32.2040
Condition: Unknown
Due 7 September 2000
Resolved 8 September 2000
Deck/Cargo
Issued 18 December 1997 Resolved
Missing stud on each port and starboard vapor recovery line flange as required by 46CFR39.20-1(e).
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Construction/Loadline
Issued 7 June 1996 Resolved
Place vent closure devices on emergency generator room vents.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Deck/Cargo
Issued 7 June 1996 Resolved
MAKE REPAIRS TO LEAKING STRIPPING PIPE IN CARGO PUMP ROOM._x001C_
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Construction/Loadline
Issued 7 June 1996 Resolved
Make permanent repairs to main ballast pump discharge piping in cargo pump room. Pump room to be manned during ballast operations. Temporary repairs were made per requirement of class (Lloyds) survey report 14JUN96.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Accommodation/Occupational Safety
Issued 7 June 1996 Resolved
HAND RAILS THROUTGHOUT MAIN DECK WASTED.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Deck/Cargo
Issued 7 June 1996 Resolved
Make permanent repairs to vapor control system high level and overfill alarms as per Lloyds Register survey report dated 14JUN96.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Documentation
Issued 7 June 1996 Resolved
Provide medical exams for Officers and Crew.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Navigation
Issued 7 June 1996 Resolved
U.S. COAST PILOT OUTDATED NO CORRECTION HAVE BEEN MADE.
Condition: Unknown
Due 20 June 1996
Resolved 20 June 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.