Inspection history · 19
28 October 2024
Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8023453
5 April 2024
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7890310
5 February 2024
MTSA/ISPS Verification · Annual Inspection · Administrative Inspection · MSP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7860434
21 August 2023
Underwater Inspection in lieu of Drydock · Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7773020
17 July 2023
Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7744212
4 April 2023
Drydock Extension
Administrative · Commandant (CG-CVC) · Activity 7662379
31 January 2023
Underwater Inspection in lieu of Drydock · Periodic Inspection · Drydock Extension · MSP Periodic Oversight · MSP Select Handover Survey
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7629491
18 April 2022
Annual Inspection · MTSA/ISPS Verification · MSP Annual Oversight
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7428307
20 April 2021
MSP Annual Oversight · Annual Inspection · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7174052
29 February 2020
Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6919663
27 January 2020
COI Inspection · MTSA/ISPS Verification · DAPI Audit · MARPOL Annex VI Survey · MSP COI Oversight · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6896887
13 December 2019
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6873353
2 December 2019
Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6863046
20 August 2019
Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6796204
7 August 2019
Annual Inspection · MSP Annual Oversight · MTSA/ISPS Verification · Ballast Water Examination
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6753779
21 July 2019
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 6987312
20 August 2018
MSP Annual Oversight · Annual Inspection · MTSA/ISPS Verification
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6487721
28 July 2016
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5955347
15 July 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 5941732
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 March 2024
Resolved
Multiple Gauges throughout the Engineroom were damaged and in need of replacement. Critical Guages were not calibrated per the manufacturer's recommendation. Ship does not have a critical gauge program in place.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 March 2024
Resolution: Class DNV issued CC to rectify deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 April 2021
Resolved
Structural fire protection shall be kept in good order so as to ensure its required performance if a fire occurs. A hole had been drilled through the A class bulkhead separating the engine control room and the port tunnel for the purpose of routing a copper water line. Restore the bulkhead to its original condition or construct an approved piping penetration.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 27 April 2021
Resolution: Repair was made by welding a metal sleeve into the bulkhead and utilizing metal piping for the water line welded into the sleeve. DNV provided a survey statement with photos indicating teh deficiency was cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 April 2021
Resolved
Each inflatable liferaft painter system shall be so arranged as to ensure that the liferaft, when released and inflated, is not dragged under by the sinking ship. The liferaft on the aft port stern had its painter secured to the liferaft securing strap instead of the weak link.
Action required: 10 - Deficiency Rectified
Resolved 20 April 2021
Resolution: Painter was properly rigged prior to inspectors' departure.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 April 2021
Resolved
Means shall be provided to control leaks of flammable liquids. An excessive diesel leak was found in the engine room, resulting in saturated pipe lagging and pooling in the bilge pocket.
Action required: 10 - Deficiency Rectified
Resolved 20 April 2021
Resolution: Leak was repaired and accumulated oil cleaned up.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Sleeping room, additional spaces
Issued 31 August 2018
Resolved
The extra security quarters on the back deck must not be used for accomodation purposes, and should be removed. Portable Quarters must be USCG approved and meet the same construction requiremnents as crew berthing.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 August 2018
Resolved 7 August 2019
Resolution: Quarters are not being used and will be removed in December dry dock. Quarters were moved inside the vessel and outfitted.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 August 2018
Resolved
Fire Station #40 hydrant leaks excessively when fire pump is energized, repack valve, or replace, to prevent leaking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 31 August 2018
Resolution: Hydrant changed out with new spare, master provided picture of replacement properly installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 August 2018
Resolved
Replace hanging splice on #1 Cargo tunnel ventilation fan, Starboard side, forward.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 September 2018
Resolved 7 September 2018
Resolution: Crew ran new power cable for the fan motor, master provided picture proof of completed work.
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 28 July 2016
Resolved
Inside the engine room (Category A machinery space) there are in excess of 15 - 55 gallon drums of combustible liquids. The max allowable is 55 gallons. 46CFR147.45(c)
Due 4 August 2016
Resolved 1 August 2016
Resolution: The crew has removed the drums from the engine room. Additionally it was noted that some of the liquids had a flashpoint above 200F and thus were not considered combustible per the definition in 46CFR147.45(c).