Records from 1990 to 2014. Most recent: inspection, 13 May 2014.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
13 May 2014
Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4853804
6 June 2012
Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4329972
5 July 2011
Annual Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4054546
5 November 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3357652
7 October 2008
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3337031
3 October 2008
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3337887
8 August 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3289689
18 July 2008
Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3271669
18 June 2007
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2958396
29 August 2006
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2763325
21 August 2006
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2754782
20 September 2005
Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2497311
1 August 2005
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2443325
2 August 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2153321
25 August 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1888049
7 July 2003
Internal Structural Exam · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1825381
8 July 2002
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1632479
27 July 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1070235
10 July 2001
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1068253
10 October 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1054861
12 July 1999
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1462767
13 July 1998
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1372314
13 August 1997
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1118196
14 July 1997
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1383626
25 July 1996
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1086601
15 July 1996
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1422715
14 August 1995
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1182564
17 July 1995
Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1444995
18 July 1994
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1412678
19 July 1993
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1154076
27 July 1992
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 947354
21 January 1992
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1259822
22 July 1991
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 934187
10 October 1990
Excursion Permit
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1228745
25 July 1990
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1217243
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 July 2011
Resolved
Replace battery in ring buoy light to an approved type.
Action required: 705 - Other - as specified
Due 4 August 2011
Resolved 8 August 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 July 2011
Resolved
Provide a USCG approved first aid kit
Due 6 August 2011
Resolved 8 August 2011
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 July 2011
Resolved
Replace cracked stbd running ligjht.
Due 5 August 2011
Resolved 8 August 2011
Lifesaving › Buoyant Smoke Signals › General
Issued 5 July 2011
Resolved
Provide 3 hand orange smoke distress signals approved
Due 8 August 2011
Resolved 8 August 2011
Lifesaving › Visual Distress Signals (General) › Storage
Issued 5 July 2011
Resolved
Provide portable watertight container for distress signals.
Due 5 August 2011
Resolved 8 August 2011
Engineering › Steering Gear System › Pump
Issued 5 July 2011
Resolved
Make repairs to leaking hydraulic ram and hydraulic pump at help.
Due 8 August 2011
Resolved 8 August 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 July 2011
Resolved
Properly secure battery containers to prevent shifting
Due 8 August 2011
Resolved 8 August 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 October 2008
Resolved
Properly mark lifesaving equipment with vessel name.
Action required: 705 - Other - as specified
Due 7 November 2008
Resolved 7 November 2008
Resolution: The lifesaving equipment was properly marked with the vessel''s name.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 October 2008
Resolved
Properly label stowage of lifejackets.
Action required: 705 - Other - as specified
Due 7 November 2008
Resolved 7 November 2008
Resolution: The lifejacket stowage areas were properly marked.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 7 October 2008
Resolved
Properly stow lifejackets and segregate child life jackets.
Action required: 705 - Other - as specified
Due 7 November 2008
Resolved 7 November 2008
Resolution: The lifejackets were properly stowed and the child lifejacket were properly segregated.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 7 October 2008
Resolved
Properly secure fire extinguisher.
Action required: 705 - Other - as specified
Due 7 November 2008
Resolved 7 November 2008
Resolution: The fire extinguisher was properly mounted/stowed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 July 2008
Resolved
Make the forward rail 39.5 inches high from the deck and make rail courses not more than 4 inches as per 46 CFR 177.900.
Action required: 705 - Other - as specified
Due 22 August 2008
Resolved 8 August 2008
Resolution: The required changes were made to make the rails comply with the regulations.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 21 August 2006
Resolved
Replace retro-reflective tape on all lifejackets and life ring buoy in accordance with 46 CFR 180.70 and 180.71.
Action required: 705 - Other - as specified
Due 21 September 2006
Resolved 28 August 2006
Resolution: Replaced retro-reflective tape on all lifejackets and life ring buoy in accordance with 46 CFR 180.70 and 180.71.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 August 2006
Resolved
Provide eye wash for first aid kit in accordance with 46 CFR 184.710.
Action required: 705 - Other - as specified
Due 21 September 2006
Resolved 28 August 2006
Resolution: Provided eye wash for first aid kit in accordance with 46 CFR 184.710.
Construction/Loadline › Structures
Issued 24 June 2003
Resolved
Grind and weld cracked welds in way of motor mount as marked. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 7 August 2003
Resolved 25 July 2003
Resolution: Weld repair satisfactory.
Construction/Loadline
Issued 10 July 2001
Resolved
PROVIDE RAILS AS REQUIRED BY 46 CFR 177.35-1(c).
Condition: Unknown
Due 10 July 2001
Resolved 10 July 2001
Documentation
Issued 14 July 1997
Resolved
PROVIDE ON BOARD A VALID FCC SAFETY CERTIFICATE IAW 47 CFR 80.93.
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Lifesaving
Issued 14 July 1997
Resolved
PROVIDE ON BOARD A LIFEJACKET DONNING PLACARD IAW 46 CFR 185.516.
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Lifesaving
Issued 14 July 1997
Resolved
RENEW THE RING LIFE BUOY IAW 46 CFR 180.70.
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Lifesaving
Issued 14 July 1997
Resolved
PROVIDE ON BOARD A 60 FOOT LIFE LINE FOR THE RING BUOY 5/16" DIAMETER, DARKIN COLOR IAW 46 CFR 180.70(C).
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Lifesaving
Issued 14 July 1997
Resolved
PROVIDE A 3 FOOT LANYARD FOR THE RING BUOY WATERLIGHT WITH A CORROSION RESISTANT CLIP IAW 46 CFR 180.70(D).
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Lifesaving
Issued 14 July 1997
Resolved
PROVIDE ON BOARD VESSEL A COAST GUARD APPROVED FIRST AID KIT IAW 46 CFR 184.710.
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Lifesaving
Issued 14 July 1997
Resolved
PROVIDE A MEANS OF SEPARATING THE STORAGE OF ADULT AND CHILDS LIFEJACKETS IAW 46 CFR 180.78(A)(5).
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Navigation
Issued 14 July 1997
Resolved
PROVIDE ON BOARD A PROPER SIZE BELL IAW 72 COLREGS ANNEX III 2(B).
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Construction/Loadline
Issued 14 July 1997
Resolved
PROPERLY REPAIR FRACTURED WELDS ON PORT AND STARBOARD SIDE OF THE TRANSOM IAW COAST GUARD NVIC 11-80.
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Documentation
Issued 14 July 1997
Resolved
PROVIDE A VALID FCC OPERATOR'S LICENSE IAW 47 CFR 80.155.
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Construction/Loadline
Issued 14 July 1997
Resolved
GRIND OUT AND REWELD PITTED WELD ON PORT SIDE OF VESSEL IAW COAST GUARD NVIC 11-80.
Condition: Unknown
Due 14 August 1997
Resolved 13 August 1997
Documentation
Issued 17 July 1995
Resolved
PROVIDE DOCUMENTATION THAT CREW IS ENROLLED IN A RANDOM DRUG TESTING PROGRAM THAT COMPLIES WITH THE REQUIREMENTS OF 46 CFR 16.
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Documentation
Issued 17 July 1995
Resolved
PROVIDE AND POST WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 17 August 1995
Resolved 21 July 1995