MAURY USCG vessel records Sign in
← All vessels

MAID OF THE MIST VI

MAID OF THE MIST VI is a passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 1990, most recently in July 2019, along with 10 deficiencies and 1 casualty investigation in 2019.

Records from 1990 to 2019. Most recent: inspection, 10 July 2019.

Built
Not recorded
Last inspected
10 July 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK8331
352226
Flag
UNITED STATES
368093110
Maury page id
psix-352226

Inspections, by type

…with no type recorded2
Years with a record 21 calendar years (1990–2019)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it74 - Regulatory (Subpart C or D), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDK8331MMSI 368093110 · active · compulsorily equipped · granted 17 May 2019, expires 17 May 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 26

10 July 2019 Administrative Inspection · Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6744615
9 July 2019 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6744884
22 January 2019 Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 6613888
5 April 2018 Administrative Inspection · Reflagging & Initial Certification
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6668876
15 March 2018 Administrative Inspection · COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6372219
22 March 2016 Deficiency Check · COC-CVE Annual
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5838198
7 May 2007 ISPS II Exam · COC-CVE Annual
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2924547
13 April 2006 COC-CVE Annual
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2623877
18 April 2005 COC-CVE Annual
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2332842
20 April 2004 Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2059136
23 April 2003 Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1782776
8 April 2002 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1602286
2 May 2001 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1441834
7 April 2000 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1468967
6 April 1999 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1468050
3 April 1998 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1414999
16 May 1997 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1421324
16 May 1996 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1082310
1 May 1995 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1390051
10 May 1994 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1362984
22 April 1993 Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1373836
17 April 1992 Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1389556
15 April 1991 Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 904902
1 October 1990 Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1238325
29 August 1990 Certificate of Compliance
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1222516
24 July 1990 Control Verification
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1233570

Deficiency record · 10

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 July 2019 Resolved
The vessel must meet the requirements for main and auxiliary steering as outlined in 46 CFR Sub-chapters F and J. The vessels primary steering failed due to an electrical issue. The part was replaced and tested to the satisfaction of attending marine inspector. Deficiency cleared on the spot.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 July 2019
Resolved 10 July 2019
Resolution: Part replaced and cleared to the satisfaction of attending Coast Guard marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 March 2016 Resolved
Remove wire nuts and properly make connection for lighting circuit. TC issued requirement
Action required: 705 - Other - as specified
Due 4 April 2016
Resolved 2 April 2016
Resolution: TC completed def check and cleared requirement.
Engineering › Bilge Water Management System › Strainer
Issued 31 March 2016 Resolved
Replace wasted / missing strainer for forepeak bilge pickup
Due 31 March 2016
Resolved 2 April 2016
Resolution: TC completed def check and cleared requirement.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 March 2016 Resolved
Replace guard for rotating machinery in steering compartment.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 2 April 2016
Resolution: TC completed def check and cleared requirement.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 March 2016 Resolved
Replace lagging for exhaust piping with steering compartment
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 2 April 2016
Resolution: TC completed def check and cleared requirement.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 March 2016 Resolved
Provide wire supports and protection for wiring within access space to void #3 inboard overhead.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 2 April 2016
Resolution: TC completed def check and cleared requirement.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 March 2016 Resolved
Provide lagging for new engine exhaust manifold within engine space.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 2 April 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 March 2016 Resolved
Provide wiring supports from battery charger to batteries and control/supply wires over shaft.
Action required: 705 - Other - as specified
Due 31 March 2016
Resolved 2 April 2016
Resolution: TC completed def check and cleared requirement.
Construction/Loadline
Issued 1 May 1995 Resolved
Demonstrate satisfactory operation of stbd e/r bilge suction prior to entryinto U.S. waters.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Fire Fighting
Issued 1 May 1995 Resolved
Demonstrate proper operation port e/r fire pump prior to operation in U.S. waters.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995

Casualty record · 1

9 July 2019Routine · role: Involved in a Marine Casualty · activity 6744884
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.