← All vessels
SCANDA
SCANDA is a 1990 freight ship. The Coast Guard has recorded 19 inspections since 1990, most recently in June 2007, along with 29 deficiencies and 3 operational controls.
Records from 1990 to 2007. Most recent: inspection, 14 June 2007.
- Built
- 1990
- Last inspected
- 14 June 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 29 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8807703 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HSS7
352257
Flag
MALTA
—
Maury page id
psix-352257
Inspections, by type
The 19 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it13583 - Convention (Subpart B), Net Ton
23473 - Convention (Subpart B), Gross Ton
40187 - Dead Weight, Ton
49952 - Displacement, Ton
23473 - Convention (Subpart B), Gross Ton
40187 - Dead Weight, Ton
49952 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 19
14 June 2007
Ballast Water Examination · ISPS III Exam · Deficiency Check · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2956182
18 May 2006
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2652606
4 November 2004
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2234526
3 November 2004
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2233915
1 November 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 295037
17 January 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 100243
9 January 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 285905
22 June 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 416757
23 June 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 32338
21 June 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 404940
24 October 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 875000
24 October 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1184465
23 October 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 384371
2 November 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 652762
1 November 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 362009
30 April 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 538850
23 September 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 353308
24 September 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 345988
23 July 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 338487
Deficiency record · 29
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 4 November 2004
Resolved
CYLINDER 2 AND 4 ON MAIN ENGINE HAVE FRESH WATER COOLING LEAK BETWEEN CYLINDER LINER AND COLER. CLASS TO ATTEST TO RECOMMENDATIONS OF REPAIRS PRIOR TO DEPARTURE.
Engineering › Steering Gear System › Motor
Issued 4 November 2004
Resolved
#1 MOTOR TO STEERING GEAR ACUATOR PUMP INOPERABLE. WOULD NOT FUCTION PROPERLY. CLASS TO ATEST TO PERMANENT REPAIRS/OPERATION PRIOR TO DEPARTURE.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 4 November 2004
Resolved
EXHAUST LEAK AT EXHAUST MANIFOLD ON # 2 SSDG. CLASS ALTEST TO PERMANENT REPAIRS/OPERATION PRIOR TO DEPARTURE.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 4 November 2004
Resolved
EXHAUST LEAK AT/BETWEEN TURBO AND EXHAUST UPTAKE PIPE. CLASS TO ALTEST TO PERMANENT REPAIRS/OPERATION PRIOR TO DEPARTURE.
Fire Fighting › Means of Escape › Mimic Plans
Issued 4 November 2004
Resolved
MISSING FIRE CONTROL PLAN PORT SIDE. OBTAIN/REPLACE PRIOR TO DEPARTURE TO SATISFACTION OF ATTENDING USCG INSPECTOR.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 4 November 2004
Resolved
FIXED FIRE FIGHTING CO2 BOTTLES IN PAINT LOCKER (I OUT OF 1) AND MAIN ENGINE ROOM (4 OUT OF 4), DISPLAY INSPECTION DATE EXPIRATION OF 05/03. PROVIDE CURRENT INSPECTION/SERVICING DATE OR PROOF OF INSPECTION. CLASS TO ALTEST TO VALID INSPECTION/SERVICE PRIOR TO DEPARTURE.
Navigation
Issued 22 June 1998
Resolved
PORT STEERING MOTOR LEAKING HYDRAULIC FLUID STEADILY AND EXCESSIVELY.
Electrical
Issued 21 June 1997
Resolved
Remove dead end cable to junction box on main deck stbd side at corner of cargo hold #7 by 23 Jun 97, SOLAS 74 CH II-1 PART D REGULATION 45.
Navigation
Issued 21 June 1997
Resolved
Install grating or equivalent non-slip on steering gear room deck, by 23 Jun 97. SOLAS 74 CH II-1 PART C REGULATION 29.
Construction/Loadline
Issued 21 June 1997
Resolved
Install deck grating where wasted on main deck prior to return to a U.S._x001C_ port.
Accommodation/Occupational Safety
Issued 21 June 1997
Resolved
Repair Emergency escape from machinery control room to allow door to close by 23 Jun 97, SOLAS 74 CH II-2 PART C REGULATION 47
Electrical
Issued 21 June 1997
Resolved
Install permanent wiring for steam electrical boiler #2 fwd stbd side in engine room, prior to return to a U.S port. SOLAS 74 CH II-1 PART D REGULATION 45.
Electrical
Issued 21 June 1997
Resolved
Install electrical matting at main switchboard by 23 Jun 97. SOLAS 74 CH II-1 PART D REGULATION 45._x001C_
Fire Fighting
Issued 21 June 1997
Resolved
Remove Hold backs from all firedoors by 23Jun97, IAW SOLAS 74 CH II-1 PART_x001C_C REGULATION 47.
Construction/Loadline
Issued 21 June 1997
Resolved
Re-install hatch or guards around lifeboat embarkation skuttles on poopdeckport and stbd sides by 23 Jun 97.
Engineering
Issued 21 June 1997
Resolved
Provide Class Society recommendation as to repairs needed to stop leak frommain engine jacket water cooling pump. SOLAS 74 CH II-1 PART C REGULATION 26.
Electrical
Issued 21 June 1997
Resolved
Repair leak at Aux Eng No 3 lube oil cooler prior to return to a U.S. port.SOLAS 74 CH II-1 PART C REGULATION 26.
Navigation
Issued 21 June 1997
Resolved
Make repairs to steering gear to stop all leaks. Presently aft steering gear pump leaks when it is shut down. Leaking reduces to a drip when operating. Inspect pump shortly after shutdown. SOLAS 74 CH II-1 PART C REGULATION 29.
Engineering
Issued 21 June 1997
Resolved
Due to failure of Jacket Water Cooling Pump and Main Air Compressor, Class Society is to conduct test of both components to determine that pernament repairs have been affected and is satisfactory for continued use. SOLAS 74 CH II-1 PART C REGULATION 26.
Electrical
Issued 23 October 1995
Resolved
VESSELS LORAN C INOPERATIVE WHEN ENTERING STRAITS OF JUAN DE FUCA.
Navigation
Issued 23 October 1995
Resolved
NOAA ISSUED CHARTS CORRECTED WITH BRITISH ADMIRALTY PUBS. NOTICE TO MARINERS CORRECTIONS NOT UP TO DATE.
Deck/Cargo
Issued 1 November 1993
Resolved
NO MECHANICAL MEANS OF CLOSURE IN SMALL DISCHARGE CONTAIMENT AS REQUIRED BY33CFR156.120(o).
Engineering
Issued 1 November 1993
Resolved
OILY WATER SEPARATOR WAS INOPERATIVE AS REQUIRED BY 33CFR151.10(a)(6).
Navigation
Issued 1 November 1993
Resolved
EMERGENCY STEERING GEAR INOPERATIVE AS REQUIRED BY 33CFR164.11(t).
Navigation
Issued 1 November 1993
Resolved
TABLE OF SHAFT REVOLUTIONS OR TABLE OF CONTROL SETTINGS FOR REPRESENTATIVE SPEEDS MISSING FROM MANEUVERING FACT SHEET AS REQUIRED BY 33CFR164.35(g)(3).
Navigation
Issued 1 November 1993
Resolved
WARNING STATEMENT WAS MISSING FROM THE BOTTOM OF THE MANEUVERING FACT SHEETAS REQUIRED BY 33CFR164.35(g)(7).
Navigation
Issued 23 July 1990
Resolved
VESSELS B.A. CHARTS 899,1063,1081, & 1082 NOT CORRECTED TO DATE AS REQUIREDBY 33CFR164.33(a)(3).
Navigation
Issued 23 July 1990
Resolved
VESSELS USCG LIGHT LIST VOL. VI. 1990ed. NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33 (a)(2)(ii).
Navigation
Issued 23 July 1990
Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ONBOARD AS REQUIRED BY 33CFR88.05.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.