Records from 2016 to 2025. Most recent: inspection, 3 June 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Professional
Detail on this page
11 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same
counts, and they are free.
$39 a month or $299 a year, every vessel page, cancel any time.
Founding rate $19.99 a month for life, for the first 200 subscribers.
Plans
Sign in
Maury does not score, rate or grade vessels, at any price.
Inspection history · 11
3 June 2025
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8146033
11 April 2025
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8106306
2 December 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8042118
29 April 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7901850
23 October 2023
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7809745
26 August 2022
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7543524
25 July 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7516324
19 November 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6858426
17 July 2018
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6481157
25 May 2018
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6423301
21 August 2016
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5979554
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 3 June 2025
Resolved
The master of a vessel shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. Passenger count is taken on board but not communicated or available ashore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2025
Resolved 21 July 2025
Resolution: OCMI provided special consideration negating need to communicate passenger count ashore.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 June 2025
Resolved
Each ring life buoy must be marked with Type II retroreflective material. Ring life buoy on board had no retroreflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2025
Resolved 16 June 2025
Resolution: Type II retro attached.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 June 2025
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel carries two styles of PFD, but only has placard for one style.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2025
Resolved 16 June 2025
Resolution: Consolidated down to one donning style and refreshed placard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 June 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit carried expired medications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2025
Resolved 16 June 2025
Resolution: Provided new first aid kit.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 July 2018
Resolved
Make installed Fireboy System operational
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 July 2018
Resolved
Must provide 21 adult and 3 Child PFD's
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2018
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 July 2018
Resolved
Provide 3 fire buckets
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2018
Engineering › Bilge Water Management System › Pump
Issued 25 May 2018
Resolved
Provide UL approved bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2018
Resolved 4 June 2018
Resolution: Installed UL approved bilge pump.
Engineering › Bilge Water Management System › Valve
Issued 25 May 2018
Resolved
Install stop valve on bilge pump discharge hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2018
Resolved 4 June 2018
Resolution: Installed ball valve on discharge hose near hull.