SERVICE BARGE 4431
- Built
- Not recorded
- Last inspected
- 20 June 1996
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Inspection record
Last inspected
20 June 1996
…with no type recorded7
Deficiencies
7 recorded · 0
without a recorded resolution
Operational controls
None recorded without a removal date
Years with a record
7 calendar years (1990–1996)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Identity
352412
Flag
UNITED STATES
Tonnage
—
Maury page id
psix-352412
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 8
20 June 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363684
13 July 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1181734
19 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449829
7 June 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363048
21 July 1993
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 155012
10 July 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 948540
19 June 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 908746
26 July 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1211456
Deficiency record · 7
Engineering
Issued 19 June 1995
Resolved
REPLACE WITH THE PROPER INSULATION BOOTS ON BURNER ELECTRODES AT TRANSFORMER.
Engineering
Issued 19 June 1995
Resolved
REASSEMBLE ELECTRICAL WIRE SHIELDING ON WIRE BUNDLE AT BOILER CONTROL PANEL.
Engineering
Issued 19 June 1995
Resolved
REWELD ANGLE CLIP TO BURNER FRONT DOOR HINGE.
Engineering
Issued 19 June 1995
Resolved
PROPERLY REMOVE DEAD END WIRES FROM BOILER CONTROL PANEL.
Engineering
Issued 7 June 1994
Resolved
PROVE PROPER CALIBRATION OF ALL INSTALLED GAUGES. CALIBRATION OF ALL GAUGES IS ANNUALLY.
Engineering
Issued 7 June 1994
Resolved
CONDUCT AN OPERATIONAL TEST OF BOILER TO INCLUDE TEST AND SETTINGS OF SAFETY VALVES AND ALARMS. TEST AND SETTINGS OF SAFETY VALVES ARE CONDUCTEDON A HOT BOILER.
Engineering
Issued 7 June 1994
Resolved
PROVIDE INFORMATION ON FUSIBLE PLUS, SUCH AS MAXIMUM TEMP AND LAST RENEWAL DATE.