MAURY USCG vessel records
← All vessels

OCEAN WRESTLER

Built
1972
Last inspected
15 December 2007
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 15 December 2007
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 5 calendar years (1999–2007)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

7119044
352413
Flag
UNITED STATES
Maury page id
psix-352413

Documentation record

Tonnage as PSIX records it242 - Convention (Subpart B), Net Ton
242 - Simplified, Net Ton
807 - Simplified, Gross Ton
807 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 22 inspections, each with its date, unit and type; 41 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 2 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SITKA PROVIDER Freight Barge · MISLE 675259 · 15 December 2007 · activity 3119437OCEAN OREGON Freight Barge · MISLE 11533 · 22 February 2007 · activity 2882307

Inspection history · 22

15 December 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3119437
11 December 2007 ISPS III Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3113887
20 April 2007 MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2911964
22 February 2007 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2882307
21 January 2007 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2859432
29 December 2006 Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2847443
19 November 2006 Type not recorded
No type recorded · Station Bellingham · USCG Northwest District (CGD-NW) · Activity 2825597
24 October 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2807365
3 September 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2767462
4 April 2006 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2616848
3 April 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2615830
21 February 2006 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2593002
11 February 2006 NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2581176
22 December 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2555364
16 November 2005 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2542589
30 June 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2409522
8 February 2005 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2287423
26 January 2005 Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2281058
11 January 2005 MARPOL Annex I Examination · Deficiency Check · PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2266309
20 February 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 640066
14 February 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 287085
9 May 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 428368

Deficiency record · 41

Documentation › Logs/Records › Garbage Recordkeeping
Issued 11 December 2007 Resolved
Vessel doe snot have a garbage management plan. This poses undue risk to the environment. MARPOL 2006 Annex V Reg 9(2)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 December 2007
Resolved 11 December 2007
Resolution: An interim garbge management plan has been approved pending a permanent plan be submitted for formal approval from the Barbados Maritime Authorities within 90 days.
Personnel › Training › Familiarization Training
Issued 11 December 2007 Resolved
Clear grounds for believing master and crew are not familiar with the essential shipboard procedures relating to the prevention of pollutionby garbage. MARPOL 2006 Annex V Reg 8
Action required: 17 - Rectify deficiencies prior to departure
Due 11 December 2007
Resolved 11 December 2007
Resolution: An interim garbge management plan has been approved pending a permanent plan be submitted for formal approval from the Barbados Maritime Authorities within 90 days.
Lifesaving › Buoyant Smoke Signals › General
Issued 11 December 2007 Resolved
Lifebouys on bridge wings are not equipped with quick release. If the life bouy was thrown overboard in an emergency the self activating smoke canister would land on the deck of the ship creating undue risk to the ship and crew. SOLAS 60 Chap. III reg 21(g)
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 11 December 2007
Resolved 11 December 2007
Resolution: Upon return to BC port vessel will work out a permanent solution to the quick release so it will easily fall into the water. The details of construction will be fromally approved by the flag administration.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 20 April 2007 Resolved
Replace 12 person liferaft with required 16 person liferaft as per the Cargo Ship Safety Equipment Certificate. Class to provide written documentation attesting to proof of replacement.
Action required: 705 - Other - as specified
Resolved 30 April 2007
Resolution: Received fax from Class attesting to clearing deficiencies.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 20 April 2007 Resolved
Prove proper operation of Echo-sounding device. Class to provide written documentation attesting the proper operation.
Action required: 705 - Other - as specified
Resolved 30 April 2007
Resolution: Received fax from Class attesting to clearing deficiencies.
Fire Fighting › Fire Hydrants › Material
Issued 20 April 2007 Resolved
Provide spanner wrenches for all fire hose stations. Written documentation must be provided by owner/operator or class.
Action required: 705 - Other - as specified
Resolved 30 April 2007
Resolution: Received fax from Class attesting to clearing deficiencies.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 11 February 2006 Resolved
Fire extinguisher No. 19 needed to be recharged. SOLAS II-2/6.5
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2006
Resolved 11 February 2006
Resolution: Fire extinguisher company attended vessel prior to USCG departure from exam.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 11 February 2006 Resolved
Make permanent repairs or replace diffuser on Fire Extinguisher system, type 5 Extinguisher No. 24 prior to return to U.S. port. SOLAS 74/78 II-2/6.5
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 11 February 2006
Resolved 21 February 2006
Resolution: New diffuser installed.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 26 January 2005 Resolved
Install doors as shown in fire control and life saving plan machinery room and crew deck both port and starboard state rooms and linen locker. Line nlocker leasds to escape hatch.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 February 2005
Resolved 8 February 2005
Resolution: New door installed separating accom. space from linen locker. Door handles to be installed on port and starboard state rooms in that vicinity.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 11 January 2005 Resolved
807 GT vessel. Master failed to possess STCW-II/2 endorsement on Barbados/Canadian license. Min. Safe Man. Cert.(MSMC) requires Master for vessel STCW-II/2. Current Master possesses <500 GT lic. on "Restricted voyages. Vessel msg (01) E.R. Watch Rating STCW III-4 personnel. Flag state endorsement pending. Req. STCW-95. Action: 70b. (Details in Narrative).
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 19 January 2005
Resolution: Master''s License has been appropriately endorsed for the intended voyage and reissued by the vessel''s flag state.
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 11 January 2005 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 26 January 2005
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 11 January 2005 Resolved
Amend Flag State Minimum Safe Manning Certificate to reflect proposed deck and engineering crew compliment as discussed with MSO Portland on 12JAN05. Current certificate requires a Master with STCW II/2 endorsement and an E.R Watch Rating of STCW III/4 endorsement on restricted voyages both of which were not met. STCW-95. Action 70b.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 19 January 2005
Resolution: New Minimum Safe Manning Certificate issued with the appropriate manning levels by the flag state.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 11 January 2005 Resolved
Address fixed CO2 fire fighting system activation, operation, control for main E/R switch board with regards to alarm/time delay and space egress time. 60 SOLAS II/58. Action 70a.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 8 February 2005
Resolution: Vessel in possession of letter issued by Bureau Veritas which indicates that the current arrangement is installed to the satisfaction of the administration.
Engineering › Bilge Water Management System › Piping
Issued 11 January 2005 Resolved
Make repairs to valve at bilge for main/GS fire pump to eliminate possibility of oily bilge water bypass during fire pump operation. Valve seat requires lapping for proper seal. MARPOL I. Action: 70c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 26 January 2005
Navigation › Emergency Steering › Compass Reading for Emergency Steering
Issued 11 January 2005 Resolved
Provide rudder angle indicator in aft steering space. 60 SOLAS V. Action: 70c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 26 January 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 January 2005 Resolved
Place nonconductive matting in way of main switch board and all other high voltage electrical panels. 60 SOLAS II/27. Action: 70c.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 26 January 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 11 January 2005 Resolved
Place proper fixtures on all lights in accommodation spaces. Spaces not subject to occupation (Lower berthing) must be secured when not in use. If lower berthing (accommodations) is to be used (by loaders), all lighting fixtures must be made to comply with the requirements. 60 SOLAS II/27. Action: 70c.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 8 February 2005
Resolution: Vessel has made repairs to fixtures observed not in compliance. For those appliances still in need of proper covers, a purchase order reveals parts on order.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 January 2005 Resolved
Make proper repairs to hand rail on second deck port side near fire hose station. ILO-147. Action: 70c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 26 January 2005
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 11 January 2005 Resolved
Provide means to secure garbage on second deck. Currently garbage bags are left on deck and are subject to discharge without a means to retain bags on board. MARPOL V. Action: 70c.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 26 January 2005
Documentation › Logs/Records › Oil Record Book
Issued 11 January 2005 Resolved
Make corrections to entries in Oil Record Book as discussed. Follow format as required by publication. 33 CFR 151.25. Action: 70c.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 26 January 2005
Electrical › Electrical Distribution System (service) › Cable
Issued 11 January 2005 Resolved
Remove or properly terminate dead-ended wires located in E/R portside across from fire pump. 60 SOLAS II/27. Action: 70a.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 26 January 2005
Engineering › Thrusters › Motor
Issued 11 January 2005 Resolved
Provide condition of class for inoperable bow thruster or make unit operational. Action: 70a.
Condition: Unknown
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 26 January 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 11 January 2005 Resolved
Properly vent clothing drier to the satisfaction of class. Action: 70a.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 26 January 2005
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 11 January 2005 Resolved
Amend oil transfer procedures to meet the requirements of 33 CFR 155.750. Action: 70c.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 8 February 2005
Resolution: OTP in satisfactory format.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 11 January 2005 Resolved
Address the following items to the satisfaction of the attending class surveyor: Fire detection systems missing from E/R, Fire alarms with annuniciator panel. Action: 70b.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 8 February 2005
Resolution: After further review of SOLAS 60 and discussion with the vessel''s class surveyor (BV), an alarm system is not required but recommended.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 January 2005 Resolved
Properly wire freezers in dry stores located in forepeak. Currently freezers are improperly spliced and present a shock hazard. 60 SOLAS II/27. Action: 70c.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2005
Resolved 26 January 2005
Fire Fighting › Fire Main › Condition
Issued 14 February 2001 Resolved
Make permanent repairs to approval of class of fire main above stbd fire pump where doubler patches exist.
Condition: Unknown
Due 16 February 2001
Resolved 14 February 2001
Resolution: New piping installed.
Fire Fighting › Fire Hoses › Number
Issued 14 February 2001 Resolved
Ensure all emergency drills are logged IAW SOLAS 74 Amd III/18.
Condition: Unknown
Due 16 February 2001
Resolved 11 January 2005
Resolution: Drills logged.
Unknown
Issued 14 February 2001 Resolved
16FEB01 _x001C_ Pacific Link Ocean Services Corp., OCEAN WRESTLER_x001C_ Vessel failed to provide advance notice of arrival.
Condition: Unknown
Due 16 February 2001
Resolved 21 February 2001
Accommodation/Occupational Safety
Issued 14 February 2001 Resolved
14FEB01_x001C_ Pacific Link Ocean Services Corp., OCEAN WRESTLER_x001C_ Marine Sanitation Device inoperative. Repair or replace the marine sanitation device.
Condition: Unknown
Due 16 February 2001
Resolved 20 February 2001
Documentation
Issued 14 February 2001 Resolved
First mates license was found expired. Provide replacement officer or obtain extension from issuing authority.
Condition: Unknown
Due 16 February 2001
Resolved 20 February 2001
Navigation
Issued 14 February 2001 Resolved
Missing GMDSS lifeboat radio. Obtain a waterproof GMDSS lifeboat radio. _x001C_SOLAS 74 Amd III/6
Condition: Unknown
Due 16 February 2001
Resolved 20 February 2001
Navigation
Issued 14 February 2001 Resolved
14FEB01_x001C_ Pacific Link Ocean Services Corp., OCEAN WRESTLER_x001C_ Vessel did not have currently corrected charts and publications. Obtain corrected/updated charts and publications.
Condition: Unknown
Due 16 February 2001
Resolved 20 February 2001
Electrical › Lighting (service) › Lighting Fixture
Issued 14 February 2001 Resolved
Provide light covers/guards for lighting fixtures.
Condition: Unknown
Due 16 February 2001
Resolved 26 January 2005
Resolution: Requirement re-issued during inspection 11Jan05
Lifesaving
Issued 14 February 2001 Resolved
Provide proper liferaft releasing/disengaging apparatus. _x001C_ Solas 60 III/4
Condition: Unknown
Due 16 February 2001
Resolved 20 February 2001
Fire Fighting
Issued 14 February 2001 Resolved
Provide face guard for fire suit.
Condition: Unknown
Due 16 February 2001
Resolved 20 February 2001
Documentation
Issued 14 February 2001 Resolved
Number of liferafts onboard does not match number required on the cargo ship safety equipment certificate. Obtain number of liferafts required on certificate or show proof of compliance.
Condition: Unknown
Due 16 February 2001
Resolved 20 February 2001
Lifesaving
Issued 14 February 2001 Resolved
Label lifering with vessel name and port of registry as per _x001C_ Solas 60 III/21.
Condition: Unknown
Due 16 February 2001
Resolved 20 February 2001
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 14 February 2001 Resolved
Make permanent repair to soft patch in fuel pipe at drain over control console.
Condition: Unknown
Due 16 February 2001
Resolved 11 January 2005
Resolution: New Piping installed.
Unknown
Issued 9 May 1999 Resolved
VESSEL RECIEVED INCORRECT THREE-WAY VALVE FOR REPLACEMENT. VSL DUE TO RECIEVE CORRECT VALVE WHILE HERE IN HMRMS.
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999
Navigation
Issued 9 May 1999 Resolved
VESSEL MISSING REQUIRED CURRENT AREA CHARTS. VSL REQUIRED TO OBTAIN PRIOR TO DEPARTURE.
Condition: Unknown
Due 12 May 1999
Resolved 12 May 1999

Ownership record