CUMBERLAND PRINCESS

CUMBERLAND PRINCESS is a 1990 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in January 2026, along with 56 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 29 January 2026.

Built
1990
Last inspected
29 January 2026
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 January 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAP7919
352419
Flag
UNITED STATES
Maury page id
psix-352419

Documentation record

Registered dimensions (L × B × D)65.0 ft × 18.6 ft × 6.2 ft
Registered tonnagegross 50 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPANHANDLE CUSTOM MARINE · PANAMA CITY, FL, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST MARYS, GA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Simplified, Net Ton
50 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

16 inspections, each with its date, unit and type; 56 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

29 January 2026 Vessel Attendance · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8303407
17 December 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8284108
25 October 2024 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8024691
30 January 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7857739
30 November 2023 DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7831590
21 September 2022 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7563387
14 January 2022 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7380112
2 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7296098
2 November 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7088261
31 January 2020 Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6900271
13 August 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6781978
23 August 2018 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6519434
7 February 2018 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6351381
8 August 2017 Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6234139
10 August 2016 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5967018
12 January 2016 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5789176

Deficiency record · 56

04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 17 December 2025 Resolved
Mechanically properly "S" vessels which are ferry vessels or which carry more than 49 passengers shall comply with the provisions of Subchapter F of this chapter. Non-metallic flexible hoses were installed on fire main and bilge systems. 46 CFR 182.40-5
Action required: 705 - Other - as specified
Resolved 1 April 2026
Resolution: MIs attended vsl and verified marine grade metallic piping installed on fire main and bilge systems.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 December 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Wires were spliced and covered with electrical tape for fresh water pump and pump on stbd main. 46 CFR 183.01-15
Action required: 705 - Other - as specified
Resolved 1 April 2026
Resolution: MIs attended vsl and verified proper repairs of spliced wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2024 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly marked. Post sign on aft pilot house bulkhead to indicate location of life jackets inside pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2024
Resolved 14 November 2024
Resolution: Provided picture of sign indicating life jackets are stored inside pilot house.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2024 Resolved
Owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of life saving equipment. Both ring life buoy grab lines are unsatisfactory.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2024
Resolved 21 November 2024
Resolution: Provided pictures.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 October 2024 Resolved
Vessel must carry adequate and up to date charts. Provide up to date charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2024
Resolved 14 November 2024
Resolution: Provided chart of area where vessel operates.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 October 2024 Resolved
Inspect weather decks. Top deck on starboard side has area of de-lamination. Repair at next dry dock.
Action required: 705 - Other - as specified
Due 31 January 2026
Resolved 29 January 2026
Resolution: Vsl issued DDE worklist item to repair de-lamination areas on top deck. See DDE MISLE# 8303407.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 October 2024 Resolved
All machinery and equipment must be installed and maintained. Starboard main jacket water elbow to head tank had unapproved repairs to piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2024
Resolved 19 May 2026
Resolution: repaired
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 October 2024 Resolved
Inspection of all accessible parts of the exterior and interior of the hull. Fore peak deck access cover was seized shut in open position.
Action required: 10 - Deficiency Rectified
Due 29 October 2024
Resolved 29 October 2024
Resolution: Crew fixed hatch cover
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2024 Resolved
Each heater must be so constructed and installed as to prevent contact with combustible materials such as towels and clothing. Removed 2 portable space heaters from pilot house.
Action required: 10 - Deficiency Rectified
Due 29 October 2024
Resolved 29 October 2024
Resolution: Removed 2 heaters.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 December 2023 Resolved
Upon activation of the fixed gas fire extinguishing system shutdown pressure switch, the main diesel engines secured, but the generator stayed running. 46 CFR 410(b)(10): A device must be provided to automatically shut down… engines that draw intake air from the protected space… Modify system to shut down all machinery in the engine room upon activation of the fire suppression system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2024
Resolved 19 December 2023
Resolution: Attended vessel, confirmed ship service generator and both main engines shut down upon activation of the Fixed CO2 fire suppressant system pressure switch. Deficiency resolved.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2023 Resolved
No means of alcohol testing were onboard the vessel or at the office. 46 CFR 4.06-15(a)(1): The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel… Purchase alcohol test strips or provide proof that alcohol breath testing can be completed within 2 hours of SMI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 19 December 2023
Resolution: Attended vessel, observed approved DOT alcohol test strips onboard. Deficiency resolved.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 September 2022 Resolved
A vessel to which 46 CFR Subchapter T applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. The vessel's COI is expired. Vessel must remain dockside until Renewal Inspection has been completed to the satisfaction of the marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2022
Resolved 12 October 2022
Resolution: COI endorsed and handed over to vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 27 September 2022 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Install guard on all rotating machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2022
Resolved 12 October 2022
Resolution: Vessel installed guards over engine pulleys.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 September 2022 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Make through blkhd penetrations watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2022
Resolved 12 October 2022
Resolution: Installed proper fire stop to seal through blkhd penetrations.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 27 September 2022 Resolved
Except as noted in paragraphs (d) and (e) below, each vessel must be equipped with a public address system. A vessel with more than one passenger deck and a vessel with overnight accommodations must have the public address system operable from the operating station. Fix broken speakers for the PA system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2022
Resolved 12 October 2022
Resolution: Fixed speaker inside acommodation space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Reattach wire into junction box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2022
Resolved 12 October 2022
Resolution: Re-attached wire into junction box.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 September 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Provide a new first-aid kit with unexpired items.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2022
Resolved 12 October 2022
Resolution: Bought brand new in compliance first aid kit.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 2 September 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 1 October 2021
Resolution: Provided copy of FCC license. See docs.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 2 September 2021 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator permit. Operator was unable to produce radio operator permit. Show proof of radio operator permit. CFR not listed: 47 CFR 80.159
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 21 October 2021
Resolution: Owner obtained radio operator permit through FCC. See docs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 September 2021 Resolved
Inspection and testing of portable extinguishers must be in accordance with NFPA 10, monthly inspections may be carried out by owner, operator, or designated crew. Vessel did not maintain records of monthly inspections. Maintain portable fire extinguishers IAW NFPA 10.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 21 October 2021
Resolution: Vessel established fire extinguisher maintenance logs.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 September 2021 Resolved
A vessel must carry a first aid kit with items as approved in 46 CFR 160.041. MI found expired aspirin and no ammonia inhalants. Outfit the first aid kit IAW 46 CFR 160.041.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 21 October 2021
Resolution: Owner obtained first aid items.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 September 2021 Resolved
Each connection or terminal end must be insulated and secured within an enclosure. MI found multiple dead end wires. Insulate and enclose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 21 October 2021
Resolution: Enclosed/insulated dead end wires that were identified.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 2 September 2021 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels. Owner/operator did not have a random testing program that met the requirements of 46 CFR 16.230. Enroll an person serving on board that performs in a safety sensitive position in to the random testing program that meets 46 CFR 16.230.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 21 October 2021
Resolution: Random drug testing pool created through computer program.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 November 2020 Resolved
All machinery installed on each vessel is suitable and maintained as to afford adequate protection against fire. Repair leaking fuel cutoff valve. 46 CFR 182.01-5 (Cite not listed in MISLE)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 2 November 2020
Resolution: Fuel leak fixed before Inspectors departed vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 November 2020 Resolved
Wiring points and splices shall be mechanically secured and made in junction boxes. Secure dead end wires into junction box or tape ends located under bridge console and a/c unit. 46 CFR 183.05-50 (Cite not listed in MISLE)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2020
Resolved 13 November 2020
Resolution: Dead end wires secured in junction box.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 2 November 2020 Resolved
Penetrations in watertight bulkheads must have means to make them watertight. Seal penetrations on forward engine room bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2020
Resolved 13 November 2020
Resolution: Penetrations sealed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 November 2020 Resolved
A vessel must comply with any applicable requirements for any radio. Program MMSI number in VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2020
Resolved 13 November 2020
Resolution: MMSI number programmed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 November 2020 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis. Randomize drug test by independent person.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2020
Resolved 13 November 2020
Resolution: Random drug test generator created by marine employer.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 November 2020 Resolved
Alcohol testing of each individual must be conducted within 2 hours of a serious marine incident. Provide means to conduct alcohol test. 46 CFR 4.06-3 (Cite not listed in MISLE)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2020
Resolved 13 November 2020
Resolution: Alcohol test strips provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 February 2020 Resolved
All vessels shall be drydocked and subject to inspection. The items listed a) through e) shall be be completed before the vessel is placed back in the water. All items shall be inspected by a marine inspector before receiving credit for drydock. a) Damage to FRP on port side amidships near water line exposing chop strand. Provide a repair proposal. b) Damage to FRP directly above port shaft, fwd of intermediate strut, prior repair is failing. Provide a repair proposal. c) FRP/coating on aft end of keel is failing. Provide a repair proposal. d) Various small areas of coating failure noted throughout the hull. Re-coat all exposed FRP. e) Make through-hull valves in fwd fuel tank space available for inspection. f) Base of railing stanchion at aft stbd corner cracked all the way through. Repair/replace railing. g) Aft-most 6 inches of seating bench on weather deck, main deck port side, is broken. Repair/replace bench. h) Engine room battery terminal connections found made with wing nuts. Properly secure all connections with permanent-type fasteners. i) Port diesel engine flywheel cover is corroded/missing and no longer provides adequate protection to personnel. Replace cover with suitable machinery guard. j) 40psi hydro-pneumatic tank in engine room fwd stbd corner is severely corroded. Provide new suitable tank. k) Overhead light fixture in engine room near fwd bulkhead is disassembled. Properly install light fixture.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2020
Resolved 18 February 2020
Resolution: All worklist items complete.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2020 Resolved
The owner or managing operator shall make the vessel available for dry-dock and internal structural examinations at the appropriate intervals. Vessel must complete a credit for dry-dock and internal structural examination prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2020
Resolved 5 February 2020
Resolution: Vessel dry-docked and made available for inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 August 2019 Resolved
Liquid level gauges shall be of heat resistant materials, adequately protected from mechanical damage, and provided at the tank connections with devices which will automatically close in the event of rupture of the gauge or gauge lines. Fuel tank gauge was plastic. 46CFR182.20-25(a)(5)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 27 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 August 2019 Resolved
A vessel on a lakes, bays, and sounds route must carry three hand red flare distress signals. Vessels hand red flares were expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 27 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 August 2019 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Life buoy not labeled.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 September 2019
Resolved 21 August 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2019 Resolved
Except as allowed by paragraphs (b) and (c) of this section, before getting underway on a voyage or as soon as practicable thereafter, the master of the vessel shall ensure that suitable public announcements are made informing the passengers of safety topics in 185.506. Vessel did not conduct or have procedures onboard for passenger safety orientation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 27 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 August 2019 Resolved
Vessel must carry up to date charts, U.S. Coast Pilot, CG Light List, Tide and Current tables. Vessel's chart was not up to date and all other publications were not onboard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 27 September 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2019 Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. Wiring connections under helm console were not mechanically secure or made in junction box. 46CFR183.05-50(b)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 27 September 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 August 2019 Resolved
Every vessel subject to Part III of Title III of the communications act must have a detailed inspection of the radio installation by an FCC licensed technician IAW 47 CFR 80.59 once every 5 years. If the ship passes the inspection, the technician will issue a communications safety act certificate. Vessel could not provide the original certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 27 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2019 Resolved
No Marine employer shall engage or employ any individual to sere as a crewmember unless the individual passes a chemical test for dangerous drugs for that employee. Marine employer did not have record of captain and crewmembers pre-employment testing.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 27 September 2019
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 23 August 2018 Resolved
Master shall conduct sufficient drills to make sure all crew members are familiar with their duties. Master did not have drill logs. Provide copies of drill logs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2018
Resolved 28 August 2018
Resolution: Provided copies of drill logs.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 23 August 2018 Resolved
Vessel must comply with applicable requirements for any radio installation as required by 47 CFR part 80. Master does not have radio operator permit. Provide copy of permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2018
Resolved 9 October 2018
Resolution: Master completed Marine Radio Operator Permit training.
Lifesaving › Lifebuoys › Serviceable
Issued 22 August 2017 Resolved
The starboard bridge wing buoy needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 25 August 2017
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 August 2017 Resolved
The retroreflective tape on (26) lifejackets needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 25 August 2017
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 22 August 2017 Resolved
The vessel name needs to be printed on (3) lifejackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 25 August 2017
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 22 August 2017 Resolved
The posted lifejacket donning instructions are for a model of jacket other than what is onboard. Replace posted placards with proper model.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 25 August 2017
Resolution: Corrected.
Fire Fighting › Fire Hydrants › Condition
Issued 22 August 2017 Resolved
The starboard side fire hydrant was spraying water at the connection. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 25 August 2017
Resolution: Corrected.
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 August 2017 Resolved
Repair potable water leak at the pipe/pump housing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 25 August 2017
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 August 2017 Resolved
Cap multiple dead-end wires at the operating system that were improperly covered with electrical tape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 25 August 2017
Resolution: Corrected.
Documentation › Certificates/Documents › FCC SSL
Issued 22 August 2017 Resolved
Station license expired in 2015. New license must be obtained.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 25 August 2017
Resolution: Corrected.
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 August 2016 Resolved
Vessel must post lifejacket donning placard for different style PFD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 15 September 2016
Resolution: Placards onboard
Navigation › Piloting/Steering › Compass Deviation Table
Issued 10 August 2016 Resolved
Provide updated magnetic compass deviation table.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 15 September 2016
Resolution: Deviation table updated
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 August 2016 Resolved
Multiple deadend wires found in forward compartment and underneath helm operating station. Wires must be removed or capped. 46 CFR 183.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 15 September 2016
Resolution: Dead end wires removed
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 10 August 2016 Resolved
Replace reflective tape on lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 15 September 2016
Resolution: tape replaced
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 August 2016 Resolved
Provide valid FCC Safety Radiotelephony Certificate. *Vessel limited to 1,000 feet from shore until corrected. 47 CFR 80.903
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 August 2016
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 August 2016 Resolved
Vessel must have Coast Pilot and tide tables on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 10 August 2016
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › Marine Charts
Issued 10 August 2016 Resolved
Provide current nautical charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 10 August 2016
Resolution: Corrected on the spot.