MAURY USCG vessel records Sign in
← All vessels

CUMBERLAND PRINCESS

CUMBERLAND PRINCESS is a 1990 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1990, most recently in January 2026, along with 122 deficiencies and 2 operational controls.

Records from 1990 to 2026. Most recent: inspection, 29 January 2026.

Built
1990
Last inspected
29 January 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAP7919
352419
Flag
UNITED STATES
367069610
Maury page id
psix-352419

Inspections, by type

Years with a record 35 calendar years (1990–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 18.6 ft × 6.2 ft
Registered tonnagegross 50 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPANHANDLE CUSTOM MARINE · PANAMA CITY, FL, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST MARYS, GA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Simplified, Net Ton
50 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAP7919MMSI 367069610 · active · compulsorily equipped · granted 12 December 2025, expires 26 November 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 72

29 January 2026 Vessel Attendance · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8303407
17 December 2025 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8284108
25 October 2024 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8024691
30 January 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7857739
30 November 2023 DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7831590
21 September 2022 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7563387
14 January 2022 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7380112
2 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7296098
2 November 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7088261
31 January 2020 Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6900271
13 August 2019 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6781978
23 August 2018 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6519434
7 February 2018 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6351381
8 August 2017 Deficiency Check · COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6234139
10 August 2016 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5967018
12 January 2016 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5789176
11 August 2015 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5200905
11 August 2014 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4951382
31 January 2012 Examination of Repairs · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4235356
1 December 2011 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4199200
8 September 2011 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4138334
1 August 2011 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4131946
12 October 2010 Excursion Permit
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3868949
18 March 2010 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3690283
6 October 2008 Excursion Permit
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3341509
28 July 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3282301
22 April 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3176212
12 October 2007 Excursion Permit
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3078555
13 September 2007 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3056620
17 October 2006 Excursion Permit
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2807791
7 August 2006 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2739066
27 July 2006 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2727778
15 May 2006 Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2649870
27 April 2006 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2638656
14 September 2005 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2493237
22 August 2005 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2471512
14 October 2004 Excursion Permit
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2220703
13 June 2004 Excursion Permit
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2096696
27 April 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2053470
9 September 2003 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1899651
13 September 2002 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1675026
16 April 2002 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1604866
23 October 2001 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1074963
9 October 2001 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1074332
10 September 2001 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1076629
6 September 2001 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1387155
22 May 2001 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1448293
14 September 2000 Re-Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1369825
4 October 1999 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1349717
22 September 1999 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1381684
2 July 1999 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1086887
21 May 1999 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 798673
5 May 1999 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1447943
2 September 1998 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1386329
17 September 1997 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1109330
16 June 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1111062
21 May 1997 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1109201
27 November 1996 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1182265
4 October 1996 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 836991
2 October 1995 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 883135
17 May 1995 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1235761
15 May 1995 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1221234
4 October 1994 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 870941
12 October 1993 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 847399
5 April 1993 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 835982
9 November 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 953256
14 October 1992 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1263479
10 October 1991 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 936131
1 October 1991 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 939098
3 January 1991 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 929961
3 December 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 915125
30 October 1990 Initial Certification · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1223317

Deficiency record · 122

04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 17 December 2025 Resolved
Mechanically properly "S" vessels which are ferry vessels or which carry more than 49 passengers shall comply with the provisions of Subchapter F of this chapter. Non-metallic flexible hoses were installed on fire main and bilge systems. 46 CFR 182.40-5
Action required: 705 - Other - as specified
Resolved 1 April 2026
Resolution: MIs attended vsl and verified marine grade metallic piping installed on fire main and bilge systems.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 December 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Wires were spliced and covered with electrical tape for fresh water pump and pump on stbd main. 46 CFR 183.01-15
Action required: 705 - Other - as specified
Resolved 1 April 2026
Resolution: MIs attended vsl and verified proper repairs of spliced wires.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2024 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly marked. Post sign on aft pilot house bulkhead to indicate location of life jackets inside pilot house.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2024
Resolved 14 November 2024
Resolution: Provided picture of sign indicating life jackets are stored inside pilot house.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 October 2024 Resolved
Owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of life saving equipment. Both ring life buoy grab lines are unsatisfactory.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2024
Resolved 21 November 2024
Resolution: Provided pictures.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 October 2024 Resolved
Vessel must carry adequate and up to date charts. Provide up to date charts.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2024
Resolved 14 November 2024
Resolution: Provided chart of area where vessel operates.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 October 2024 Resolved
Inspect weather decks. Top deck on starboard side has area of de-lamination. Repair at next dry dock.
Action required: 705 - Other - as specified
Due 31 January 2026
Resolved 29 January 2026
Resolution: Vsl issued DDE worklist item to repair de-lamination areas on top deck. See DDE MISLE# 8303407.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 October 2024 Resolved
All machinery and equipment must be installed and maintained. Starboard main jacket water elbow to head tank had unapproved repairs to piping.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 November 2024
Resolved 19 May 2026
Resolution: repaired
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 29 October 2024 Resolved
Inspection of all accessible parts of the exterior and interior of the hull. Fore peak deck access cover was seized shut in open position.
Action required: 10 - Deficiency Rectified
Due 29 October 2024
Resolved 29 October 2024
Resolution: Crew fixed hatch cover
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2024 Resolved
Each heater must be so constructed and installed as to prevent contact with combustible materials such as towels and clothing. Removed 2 portable space heaters from pilot house.
Action required: 10 - Deficiency Rectified
Due 29 October 2024
Resolved 29 October 2024
Resolution: Removed 2 heaters.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 December 2023 Resolved
Upon activation of the fixed gas fire extinguishing system shutdown pressure switch, the main diesel engines secured, but the generator stayed running. 46 CFR 410(b)(10): A device must be provided to automatically shut down… engines that draw intake air from the protected space… Modify system to shut down all machinery in the engine room upon activation of the fire suppression system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2024
Resolved 19 December 2023
Resolution: Attended vessel, confirmed ship service generator and both main engines shut down upon activation of the Fixed CO2 fire suppressant system pressure switch. Deficiency resolved.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2023 Resolved
No means of alcohol testing were onboard the vessel or at the office. 46 CFR 4.06-15(a)(1): The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel… Purchase alcohol test strips or provide proof that alcohol breath testing can be completed within 2 hours of SMI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2023
Resolved 19 December 2023
Resolution: Attended vessel, observed approved DOT alcohol test strips onboard. Deficiency resolved.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 September 2022 Resolved
A vessel to which 46 CFR Subchapter T applies may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection. The vessel's COI is expired. Vessel must remain dockside until Renewal Inspection has been completed to the satisfaction of the marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2022
Resolved 12 October 2022
Resolution: COI endorsed and handed over to vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 27 September 2022 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Install guard on all rotating machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2022
Resolved 12 October 2022
Resolution: Vessel installed guards over engine pulleys.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 27 September 2022 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Make through blkhd penetrations watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2022
Resolved 12 October 2022
Resolution: Installed proper fire stop to seal through blkhd penetrations.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 27 September 2022 Resolved
Except as noted in paragraphs (d) and (e) below, each vessel must be equipped with a public address system. A vessel with more than one passenger deck and a vessel with overnight accommodations must have the public address system operable from the operating station. Fix broken speakers for the PA system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2022
Resolved 12 October 2022
Resolution: Fixed speaker inside acommodation space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 September 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Reattach wire into junction box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2022
Resolved 12 October 2022
Resolution: Re-attached wire into junction box.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 September 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Provide a new first-aid kit with unexpired items.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2022
Resolved 12 October 2022
Resolution: Bought brand new in compliance first aid kit.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 2 September 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 1 October 2021
Resolution: Provided copy of FCC license. See docs.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 2 September 2021 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator permit. Operator was unable to produce radio operator permit. Show proof of radio operator permit. CFR not listed: 47 CFR 80.159
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 21 October 2021
Resolution: Owner obtained radio operator permit through FCC. See docs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 September 2021 Resolved
Inspection and testing of portable extinguishers must be in accordance with NFPA 10, monthly inspections may be carried out by owner, operator, or designated crew. Vessel did not maintain records of monthly inspections. Maintain portable fire extinguishers IAW NFPA 10.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 21 October 2021
Resolution: Vessel established fire extinguisher maintenance logs.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 2 September 2021 Resolved
A vessel must carry a first aid kit with items as approved in 46 CFR 160.041. MI found expired aspirin and no ammonia inhalants. Outfit the first aid kit IAW 46 CFR 160.041.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 21 October 2021
Resolution: Owner obtained first aid items.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 September 2021 Resolved
Each connection or terminal end must be insulated and secured within an enclosure. MI found multiple dead end wires. Insulate and enclose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 21 October 2021
Resolution: Enclosed/insulated dead end wires that were identified.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 2 September 2021 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crew members on inspected vessels. Owner/operator did not have a random testing program that met the requirements of 46 CFR 16.230. Enroll an person serving on board that performs in a safety sensitive position in to the random testing program that meets 46 CFR 16.230.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 October 2021
Resolved 21 October 2021
Resolution: Random drug testing pool created through computer program.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 2 November 2020 Resolved
All machinery installed on each vessel is suitable and maintained as to afford adequate protection against fire. Repair leaking fuel cutoff valve. 46 CFR 182.01-5 (Cite not listed in MISLE)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 November 2020
Resolved 2 November 2020
Resolution: Fuel leak fixed before Inspectors departed vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 2 November 2020 Resolved
Wiring points and splices shall be mechanically secured and made in junction boxes. Secure dead end wires into junction box or tape ends located under bridge console and a/c unit. 46 CFR 183.05-50 (Cite not listed in MISLE)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2020
Resolved 13 November 2020
Resolution: Dead end wires secured in junction box.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 2 November 2020 Resolved
Penetrations in watertight bulkheads must have means to make them watertight. Seal penetrations on forward engine room bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2020
Resolved 13 November 2020
Resolution: Penetrations sealed.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 2 November 2020 Resolved
A vessel must comply with any applicable requirements for any radio. Program MMSI number in VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2020
Resolved 13 November 2020
Resolution: MMSI number programmed.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 November 2020 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis. Randomize drug test by independent person.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2020
Resolved 13 November 2020
Resolution: Random drug test generator created by marine employer.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 November 2020 Resolved
Alcohol testing of each individual must be conducted within 2 hours of a serious marine incident. Provide means to conduct alcohol test. 46 CFR 4.06-3 (Cite not listed in MISLE)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 December 2020
Resolved 13 November 2020
Resolution: Alcohol test strips provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 February 2020 Resolved
All vessels shall be drydocked and subject to inspection. The items listed a) through e) shall be be completed before the vessel is placed back in the water. All items shall be inspected by a marine inspector before receiving credit for drydock. a) Damage to FRP on port side amidships near water line exposing chop strand. Provide a repair proposal. b) Damage to FRP directly above port shaft, fwd of intermediate strut, prior repair is failing. Provide a repair proposal. c) FRP/coating on aft end of keel is failing. Provide a repair proposal. d) Various small areas of coating failure noted throughout the hull. Re-coat all exposed FRP. e) Make through-hull valves in fwd fuel tank space available for inspection. f) Base of railing stanchion at aft stbd corner cracked all the way through. Repair/replace railing. g) Aft-most 6 inches of seating bench on weather deck, main deck port side, is broken. Repair/replace bench. h) Engine room battery terminal connections found made with wing nuts. Properly secure all connections with permanent-type fasteners. i) Port diesel engine flywheel cover is corroded/missing and no longer provides adequate protection to personnel. Replace cover with suitable machinery guard. j) 40psi hydro-pneumatic tank in engine room fwd stbd corner is severely corroded. Provide new suitable tank. k) Overhead light fixture in engine room near fwd bulkhead is disassembled. Properly install light fixture.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2020
Resolved 18 February 2020
Resolution: All worklist items complete.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2020 Resolved
The owner or managing operator shall make the vessel available for dry-dock and internal structural examinations at the appropriate intervals. Vessel must complete a credit for dry-dock and internal structural examination prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2020
Resolved 5 February 2020
Resolution: Vessel dry-docked and made available for inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 August 2019 Resolved
Liquid level gauges shall be of heat resistant materials, adequately protected from mechanical damage, and provided at the tank connections with devices which will automatically close in the event of rupture of the gauge or gauge lines. Fuel tank gauge was plastic. 46CFR182.20-25(a)(5)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 27 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 August 2019 Resolved
A vessel on a lakes, bays, and sounds route must carry three hand red flare distress signals. Vessels hand red flares were expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 27 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 August 2019 Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Life buoy not labeled.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 September 2019
Resolved 21 August 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2019 Resolved
Except as allowed by paragraphs (b) and (c) of this section, before getting underway on a voyage or as soon as practicable thereafter, the master of the vessel shall ensure that suitable public announcements are made informing the passengers of safety topics in 185.506. Vessel did not conduct or have procedures onboard for passenger safety orientation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 27 September 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 August 2019 Resolved
Vessel must carry up to date charts, U.S. Coast Pilot, CG Light List, Tide and Current tables. Vessel's chart was not up to date and all other publications were not onboard.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 27 September 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 August 2019 Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. Wiring connections under helm console were not mechanically secure or made in junction box. 46CFR183.05-50(b)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 27 September 2019
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 August 2019 Resolved
Every vessel subject to Part III of Title III of the communications act must have a detailed inspection of the radio installation by an FCC licensed technician IAW 47 CFR 80.59 once every 5 years. If the ship passes the inspection, the technician will issue a communications safety act certificate. Vessel could not provide the original certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 September 2019
Resolved 27 September 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2019 Resolved
No Marine employer shall engage or employ any individual to sere as a crewmember unless the individual passes a chemical test for dangerous drugs for that employee. Marine employer did not have record of captain and crewmembers pre-employment testing.
Action required: 705 - Other - as specified
Due 4 September 2019
Resolved 27 September 2019
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 23 August 2018 Resolved
Master shall conduct sufficient drills to make sure all crew members are familiar with their duties. Master did not have drill logs. Provide copies of drill logs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2018
Resolved 28 August 2018
Resolution: Provided copies of drill logs.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 23 August 2018 Resolved
Vessel must comply with applicable requirements for any radio installation as required by 47 CFR part 80. Master does not have radio operator permit. Provide copy of permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2018
Resolved 9 October 2018
Resolution: Master completed Marine Radio Operator Permit training.
Lifesaving › Lifebuoys › Serviceable
Issued 22 August 2017 Resolved
The starboard bridge wing buoy needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 25 August 2017
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 August 2017 Resolved
The retroreflective tape on (26) lifejackets needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 25 August 2017
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 22 August 2017 Resolved
The vessel name needs to be printed on (3) lifejackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 25 August 2017
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 22 August 2017 Resolved
The posted lifejacket donning instructions are for a model of jacket other than what is onboard. Replace posted placards with proper model.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 25 August 2017
Resolution: Corrected.
Fire Fighting › Fire Hydrants › Condition
Issued 22 August 2017 Resolved
The starboard side fire hydrant was spraying water at the connection. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 25 August 2017
Resolution: Corrected.
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 August 2017 Resolved
Repair potable water leak at the pipe/pump housing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 25 August 2017
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 August 2017 Resolved
Cap multiple dead-end wires at the operating system that were improperly covered with electrical tape.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 25 August 2017
Resolution: Corrected.
Documentation › Certificates/Documents › FCC SSL
Issued 22 August 2017 Resolved
Station license expired in 2015. New license must be obtained.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 September 2017
Resolved 25 August 2017
Resolution: Corrected.
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 August 2016 Resolved
Vessel must post lifejacket donning placard for different style PFD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 15 September 2016
Resolution: Placards onboard
Navigation › Piloting/Steering › Compass Deviation Table
Issued 10 August 2016 Resolved
Provide updated magnetic compass deviation table.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 15 September 2016
Resolution: Deviation table updated
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 August 2016 Resolved
Multiple deadend wires found in forward compartment and underneath helm operating station. Wires must be removed or capped. 46 CFR 183.01-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 15 September 2016
Resolution: Dead end wires removed
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 10 August 2016 Resolved
Replace reflective tape on lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 15 September 2016
Resolution: tape replaced
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 10 August 2016 Resolved
Provide valid FCC Safety Radiotelephony Certificate. *Vessel limited to 1,000 feet from shore until corrected. 47 CFR 80.903
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 10 August 2016
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 August 2016 Resolved
Vessel must have Coast Pilot and tide tables on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 10 August 2016
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › Marine Charts
Issued 10 August 2016 Resolved
Provide current nautical charts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 September 2016
Resolved 10 August 2016
Resolution: Corrected on the spot.
Engineering › Gasoline Engine (propulsion) › Cylinder (4 cycle)
Issued 11 August 2015 Resolved
Secure guards on STBD engine belt and over belt on generator.
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 31 August 2015
Resolution: guards have been secured.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 11 August 2015 Resolved
Ensure fire extinguishers in engine room are seated in proper brackets.
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 24 August 2015
Resolution: Extinguisher is seated firmly in bracket.
Lifesaving › Lifebuoys › Size
Issued 11 August 2015 Resolved
Replace life ring on STBD side with 24 inch life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2015
Resolution: Life ring is standard size.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 August 2015 Resolved
Ensure reflective tape is on STBD life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2015
Resolution: reflective tape is on STBD life ring.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 11 August 2015 Resolved
Ensure vent hose is connected to aft MSD and opening is plugged in STBD MSD.
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 24 August 2015
Resolution: vent hose is connected to aft MSD and opening is plugged.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 11 August 2015 Resolved
Ensure lagging is placed on exposed exhaust piping port engine inboard.
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 24 August 2015
Resolution: lagging has been installed on exhaust piping port engine.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 11 August 2015 Resolved
Obtain new FCC Safety Certificate as current is expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2015
Resolution: FCC safety certificate has been obtained, expires in 2020.
Engineering › Bilge Water Management System › Piping
Issued 11 August 2015 Resolved
Secure wires in lazzarette as far out of the bilge as possible.
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 24 August 2015
Resolution: Wires are secured and out of water in lazzarette.
Documentation › Markings/Placards › Capacity Marking
Issued 11 August 2015 Resolved
Amend max allowable passenger sign on upper deck, signage should read 33 passengers max.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2015
Resolution: Upper deck limit has been corrected to read 33 passengers.
Electrical › Electrical Distribution System (service) › Cable
Issued 11 August 2015 Resolved
Remove dead end (positive) cable under counsel/bridge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2015
Resolution: Dead end cable has been removed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 August 2015 Resolved
Secure batteries from movement within boxes.
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 24 August 2015
Resolution: batteries have been secured
Electrical › Lighting (service) › Outlet Box
Issued 11 August 2015 Resolved
Secure lightswitch box leading into engine room.
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 24 August 2015
Resolution: Lightswitch has been secured.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 August 2015 Resolved
Replace all wire nuts and electrical tape over splicing with compression fittings.
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 3 September 2015
Resolution: Pictures were received that showed deficiency has been rectified.
Engineering › Generator (propulsion-electric) › Winding
Issued 11 August 2015 Resolved
Replace and secure drain hose on expansion tank on generator.
Action required: 705 - Other - as specified
Due 18 August 2015
Resolved 24 August 2015
Resolution: drain hose has been secured.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 11 August 2015 Resolved
Switchboard required to be operable, voltometer and frequency gauge.
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 24 August 2015
Resolution: operable guage has been installed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 11 August 2015 Resolved
Make repairs to leaking steering bezel connections.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2015
Resolution: all nuts have been tightened and leaking has ceased.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 11 August 2015 Resolved
Missing visual light and overide at operating station for pre-engineered system.
Action required: 705 - Other - as specified
Due 10 September 2015
Resolved 24 August 2015
Resolution: visual light and overide has been installed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 30 July 2015 Resolved
Write vessel name on both life rings.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2015
Resolution: vessel name is written on both life rings.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 11 August 2014 Resolved
Install clevis pins for port MDE control linkage and port reduction gear control linkage.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 August 2014
Resolved 12 August 2014
Resolution: Owner/operator installed clevis pins for the aforementioned systems.
Electrical › Electric Generation Source (service) › Generator
Issued 11 August 2014 Resolved
Conduct maintenance (clean and degrease) on generator.
Action required: 705 - Other - as specified
Due 12 September 2014
Resolved 22 August 2014
Resolution: Vessel owner cleaned generator box and windings.
Electrical › Electric Supply System (service) › Battery Installation
Issued 11 August 2014 Resolved
Replace locking fastener for service/start batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2014
Resolution: Owner/operator replaced all hardware for service/start batteries.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 August 2014 Resolved
Replace expired items on vessel's first aid kit.
Action required: 705 - Other - as specified
Due 19 August 2014
Resolved 19 August 2014
Resolution: Vessel owner purchased a CG approved first aid kit.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 August 2014 Resolved
Remove unapproved connectors (wire nuts) under bridge console and replace with approved connectors.
Action required: 705 - Other - as specified
Due 22 September 2014
Resolved 22 August 2014
Resolution: Vessel owner removed and replaced all unapproved connector under the bridge console.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 August 2014 Resolved
Remove dead-end wires under bridge console and forward A/C compartment.
Action required: 705 - Other - as specified
Due 22 September 2014
Resolved 22 August 2014
Resolution: Vessel owner removed all dead-end wires under bridge console and fwd A/C compartment.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 September 2011 Resolved
Renew/repair extinguished stern navigation light.
Condition: Improper/Lack of Maintenance
Due 15 September 2011
Resolved 27 September 2011
Lifesaving › Lifefloat › Retroreflective Material
Issued 8 September 2011 Resolved
Renew worn/wasted retroreflective tape on both lifefloats.
Condition: Improper/Lack of Maintenance
Due 15 September 2011
Resolved 27 September 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 July 2008 Resolved
Renew expired first aid kit contents.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2008
Resolved 25 August 2008
Resolution: New first aid kit provided onboard.
Navigation › Piloting/Steering › Marine Charts
Issued 28 July 2008 Resolved
Ensure current and/or corrected charts and publications are available on the bridge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 August 2008
Resolution: New charts were placed on the vessel along with current publications.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 28 July 2008 Resolved
Replace the six expired smoke signals.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2008
Resolution: New smoke signals provided onboard
Documentation › Markings/Placards › Capacity Marking
Issued 28 July 2008 Resolved
Ensure signage on upper deck is posted and outlines proper number of passengers allowed as per stability letter.
Condition: Improper/Lack of Maintenance
Due 15 September 2008
Resolved 25 August 2008
Resolution: New sign posted to allow 39 passengers on upper deck. All Sat.
Lifesaving › Lifefloat › Float-free Link
Issued 28 July 2008 Resolved
Ensure proper securing of float free arrangement on port life float.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2008
Resolution: Proper installations of weak link observed.
Documentation › Markings/Placards › Warning Signs
Issued 28 July 2008 Resolved
Properly label fuel shutoff valves on port side of vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2008
Resolution: New remote fuel shutoff placard installed. All Sat.
Fire Fighting › Fire Main › Material
Issued 28 July 2008 Resolved
Renew fire main system with approved piping and ensure all ruptures are repaired. Remove and hard pipe or replace fire main valve with metal valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2008
Resolution: Fire main system renewed with copper tubing. All Sat.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 July 2008 Resolved
Remove improper fixed bilge piping and replace with approved piping. Remove rubber repair piping.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2008
Resolution: New bilge piping installed. All Sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 28 July 2008 Resolved
Repair the exhaust leak on the port engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 August 2008
Resolution: New exhaust flange and gasket installed. All Sat.
Documentation › Markings/Placards › Lifejacket Placard
Issued 28 July 2008 Resolved
Ensure additional life jacket instruction placards are posted as appropriate for the number of passengers carried.
Condition: Placed in Improper Service
Due 15 September 2008
Resolved 15 August 2008
Resolution: Two additional life jacket instruction placards were posted onboard the vessel.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 July 2006 Resolved
Mark the Port and Starboard Life Ring's with the vessel's name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2006
Resolved 7 August 2006
Resolution: Port and starboard life ring''s marked with vessel''s name.
Lifesaving › Lifefloat › Serviceable
Issued 27 July 2006 Resolved
Holes in the starboard lifefloat. Repair or replace the lifefloat.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 August 2006
Resolved 7 August 2006
Resolution: Replaced with new float.
Lifesaving › Lifefloat › Retroreflective Material
Issued 27 July 2006 Resolved
Replace retroreflective material on the starboard lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2006
Resolved 7 August 2006
Resolution: Lifefloat was replace, retroreflective tape is on the new float.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 27 July 2006 Resolved
The cylinder in very rusty. Perform PMS and provide hydro test date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2006
Resolved 7 August 2006
Resolution: Cylinder was PMS and has a good hydro date.
Construction/Loadline › Hull › Bottom Plating
Issued 16 May 2006 Resolved
Fiberglass delaminating on port side bottom near shaft penetration, approximately 10" X 23" area , and small hole in bow. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Due 23 May 2006
Resolved 1 June 2006
Engineering › Fuel Oil Service System › Valve
Issued 16 May 2006 Resolved
Provide covers for emergency fuel shut off valves that can be opened easily, or mount tool to remove existing covers.
Condition: Improper/Lack of Maintenance
Due 16 June 2006
Resolved 1 June 2006
Lifesaving › Lifefloat › Serviceable
Issued 23 August 2005 Resolved
Vessel limited to LBS route until one (1) twenty two (22) person lifefloat and EPIRB renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 September 2005
Electrical
Issued 6 September 2001 Resolved
FWD HOLD CONDENSATE PUMP ELECT CONNECTION TWISTED, MAKE PERMANET REPAIRS (CRIP WIRES)
Condition: Unknown
Due 6 September 2001
Resolved 6 September 2001
Electrical
Issued 6 September 2001 Resolved
FWD VENTILATION BLOWERS IN OVERHEAD INOPERATIVE AND SPLICE WIRES HOOKED IN OVERHEAD. (REPLACE BLOWER MAKE PERMANENT REPAIRS)
Condition: Unknown
Due 6 September 2001
Resolved 6 September 2001
Construction/Loadline
Issued 6 September 2001 Resolved
FWD BILGE ALARM INOPERATIVE (CORRODED WIRES) AT CONNECTION
Condition: Unknown
Due 6 September 2001
Resolved 6 September 2001
Fire Fighting
Issued 14 September 2000 Resolved
PROVIDE INFORMATION ON THE FIXED FIRE SYSTEM ANNUAL MAINTENANCE FOR BOTTLE,HEAT DETECTOR AND ENGINE SHUTDOWNS.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Lifesaving
Issued 22 September 1999 Resolved
VESSEL RESTRICTED TO 3NM UNTIL AN APPROVED EPIRB IS FOUND INSTALLED.
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Fire Fighting
Issued 5 May 1999 Resolved
IAW 181.400 PROVIDE A FIXED FIRE EXTING SYS IN THE ENGINE ROOM.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Electrical
Issued 5 May 1999 Resolved
REPAIR LIGHT AND INSTALL GUARD IN THE AFT END OF THE E/R.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Lifesaving
Issued 5 May 1999 Resolved
REPAIR/REPLACE P/S PILOTHOUSE RING-BUOYS.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Construction/Loadline
Issued 5 May 1999 Resolved
INSTALL 3 HIGH WATER BILGE ALARMS FOR THE AC SPACE, E/R, AND AFT STEERING.
Condition: Unknown
Due 5 May 1999
Resolved 5 May 1999
Construction/Loadline
Issued 21 May 1997 Resolved
NENEW A/C OVBD DISCHARGE VALVE.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997 Resolved
RENEW O-RING FOR FOREPEAK BILGE ACCESS PLATE.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997 Resolved
RENEW ROTTED PLYWOOD OVERHEAD IN FOREPEAK, P/SIDE.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997 Resolved
RENEW GSKT ON HATCH TO LAZARETTE.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Lifesaving
Issued 4 October 1996 Resolved
STENCIL VESSEL NAME ON LIFE FLOAT OARS.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Fire Fighting
Issued 4 October 1996 Resolved
REPAIR/REPLACE INOPERATIVE MECHANICAL FIRE PUMP.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Lifesaving
Issued 4 October 1996 Resolved
REPAIR/REPLACE DETERIORATED GRABLINES ON RING BUOYS.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Lifesaving
Issued 4 October 1996 Resolved
REPAIR/REPLACE DETERIORATED GRAB LINES AND RETRO REFLECTIVE TAPE ON LIFE FLOATS.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Lifesaving
Issued 4 October 1996 Resolved
INSTALL/MOUNT INSTRUCTIONS FOR PROPERLY DONNING/WEARING LIFE JACKETS IN THEMAIN PASSENGER SPACE.
Condition: Unknown
Due 4 October 1996
Resolved 4 October 1996
Electrical
Issued 14 October 1992 Resolved
REMOVE OR DEAD-END ALL LOOSE WIRES BEHIND STEERING STATION IN WAY OF ELECTRICAL TRANSFORMERS.
Condition: Unknown
Due 14 October 1992
Resolved 14 October 1992
Documentation
Issued 30 October 1990 Resolved
PROVIDE AND POST U.S. COAST GUARD STABILITY LETTER. NO PASSENGERS ARE TO BECARRIED UNTIL USCG STABILITY LETTER IS ISSUED AND POSTED.
Condition: Unknown
Due 30 October 1990
Resolved 30 October 1990
Documentation
Issued 30 October 1990 Resolved
PROVIDE FCC SAFETY CERTIFICATE
Condition: Unknown
Due 30 October 1990
Resolved 30 October 1990
Navigation
Issued 30 October 1990 Resolved
PROVIDE CURRENT RULES OF THE ROAD AND CHARTS FOR VESSEL'S OPERATING AREA
Condition: Unknown
Due 30 October 1990
Resolved 30 October 1990
Navigation
Issued 30 October 1990 Resolved
PROVIDE DAY SHAPES FOR ANCHORING (NAV RULES- RULE 30)
Condition: Unknown
Due 30 October 1990
Resolved 30 October 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.