MAURY USCG vessel records Sign in
← All vessels

ZAMET

ZAMET is a 1979 freight ship. The Coast Guard has recorded 15 inspections since 1990, most recently in November 1996, along with 15 deficiencies and 3 operational controls, 1 with no removal date recorded.

Records from 1990 to 1996. Most recent: inspection, 15 November 1996.

Built
1979
Last inspected
15 November 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7521467 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
352852
Flag
PANAMA
—
Maury page id
psix-352852

Inspections, by type

…with no type recorded14
Years with a record 7 calendar years (1990–1996)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5120 - Convention (Subpart B), Gross Ton
61468 - Dead Weight, Ton
2629 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

15 November 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 397432
4 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 387491
22 November 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 384958
29 June 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 380104
3 August 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 369122
2 August 1994 Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1174689
5 July 1994 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 368203
25 May 1994 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 367169
15 November 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 362506
16 May 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 175357
19 February 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 15791
7 December 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 452745
1 May 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 527507
15 October 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 346407
4 August 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 338609

Deficiency record · 15

Accommodation/Occupational Safety
Issued 4 February 1996 Resolved
PERMANENTLY REPAIR DETERIORATED RAILING, MAINDECK ON STERN, STARBOARD SIDE_x001C_ICLL 66 R. 25
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Lifesaving
Issued 4 February 1996 Resolved
PROPERLY MOUNT ADDITIONAL 6-MAN LIFERAFT ON BOAT DECK, PORT SIDE._x001C_ SOLAS 74 (AMENDED) III/23.
Condition: Unknown
Due 5 February 1996
Resolved 12 February 1996
Engineering
Issued 4 February 1996 Resolved
PROVE PROPER OPERATION OF AUTOMATIC STOPPING DEVICE FOR OILY WATER_x001C_ SEPARATOR OR HAVE IOPP CERTIFICATE REVISED TO INDICATE NO STOPPING_x001C_ DEVICE._x001C_ 33 C.F.R. 155.380(b)
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Lifesaving
Issued 4 February 1996 Resolved
PROPERLY SECURE INFLATABLE LIFERAFT ON BOATDECK, STBD SIDE.
Condition: Unknown
Due 5 February 1996
Resolved 12 February 1996
Fire Fighting
Issued 4 February 1996 Resolved
REPAIR GENERAL ALARM IN STEERING GEAR ROOM._x001C_ SOLAS 60 CHAP. III/19(a)(iii)
Condition: Unknown
Due 5 February 1996
Resolved 12 February 1996
Accommodation/Occupational Safety
Issued 4 February 1996 Resolved
PROVIDE VENT COVER TO FORECASTLE SPACE.
Condition: Unknown
Due 5 February 1996
Resolved 12 February 1996
Documentation
Issued 4 February 1996 Resolved
PROVIDE PROPER MEDICAL CERTIFICATE FOR VESSEL'S MECHANIC, [name withheld]_x001C_ MIHAJHO, PASSPORT #003819._x001C_ ILO 147, ART. II
Condition: Unknown
Due 18 November 1996
Resolved 18 November 1996
Fire Fighting
Issued 22 November 1995 Resolved
INACCURATE FIRE CONTROL PLAN.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Fire Fighting
Issued 22 November 1995 Resolved
HOLES IN FIRE MAIN PIPING MAIN DECK.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Fire Fighting
Issued 22 November 1995 Resolved
SOFT PATCHES ON INTAKE LINE ON PRIMARY PUMP.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Navigation
Issued 29 June 1995 Resolved
BRIDGE RUDDER ANGLE INDICATOR OUT OF ALIGNMENT. SOLAS 74/78.
Condition: Unknown
Due 3 July 1995
Resolved 7 July 1995
Engineering
Issued 29 June 1995 Resolved
REPAIR OILY WATER SEPARATOR TO INDICATE PROPER 15PPM ALARM. MARPOL I/9,16
Condition: Unknown
Due 3 July 1995
Resolved 7 July 1995
Fire Fighting
Issued 2 August 1994 Resolved
REPLACE WASTED AND LEAKING SECTION OF FIREMAIN LOCATED IN FRONT OF BOTTOM OF SUPERSTRUCTURE TO THE SATISFACTION OF THE CLASS SOCIETY PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 August 1994
Resolved 4 August 1994
Navigation
Issued 15 October 1991 Resolved
charts of local area not corrected up to date.
Condition: Unknown
Due 25 October 1991
Resolved 25 October 1991
Navigation
Issued 15 October 1991 Resolved
current tidal tables not on board.
Condition: Unknown
Due 25 October 1991
Resolved 25 October 1991

Ownership record