← All vessels
ZAMET
ZAMET is a 1979 freight ship. The Coast Guard has recorded 15 inspections since 1990, most recently in November 1996, along with 15 deficiencies and 3 operational controls, 1 with no removal date recorded.
Records from 1990 to 1996. Most recent: inspection, 15 November 1996.
- Built
- 1979
- Last inspected
- 15 November 1996
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- 1 with no removal date recorded
Identity
7521467 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9AWB
352852
Flag
PANAMA
—
Maury page id
psix-352852
Inspections, by type
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it5120 - Convention (Subpart B), Gross Ton
61468 - Dead Weight, Ton
2629 - Convention (Subpart B), Net Ton
61468 - Dead Weight, Ton
2629 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 15
15 November 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 397432
4 February 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 387491
22 November 1995
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 384958
29 June 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 380104
3 August 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 369122
2 August 1994
Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1174689
5 July 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 368203
25 May 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 367169
15 November 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 362506
16 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 175357
19 February 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 15791
7 December 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 452745
1 May 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 527507
15 October 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 346407
4 August 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 338609
Deficiency record · 15
Accommodation/Occupational Safety
Issued 4 February 1996
Resolved
PERMANENTLY REPAIR DETERIORATED RAILING, MAINDECK ON STERN, STARBOARD SIDE_x001C_ICLL 66 R. 25
Lifesaving
Issued 4 February 1996
Resolved
PROPERLY MOUNT ADDITIONAL 6-MAN LIFERAFT ON BOAT DECK, PORT SIDE._x001C_ SOLAS 74 (AMENDED) III/23.
Engineering
Issued 4 February 1996
Resolved
PROVE PROPER OPERATION OF AUTOMATIC STOPPING DEVICE FOR OILY WATER_x001C_ SEPARATOR OR HAVE IOPP CERTIFICATE REVISED TO INDICATE NO STOPPING_x001C_ DEVICE._x001C_ 33 C.F.R. 155.380(b)
Lifesaving
Issued 4 February 1996
Resolved
PROPERLY SECURE INFLATABLE LIFERAFT ON BOATDECK, STBD SIDE.
Fire Fighting
Issued 4 February 1996
Resolved
REPAIR GENERAL ALARM IN STEERING GEAR ROOM._x001C_ SOLAS 60 CHAP. III/19(a)(iii)
Accommodation/Occupational Safety
Issued 4 February 1996
Resolved
PROVIDE VENT COVER TO FORECASTLE SPACE.
Documentation
Issued 4 February 1996
Resolved
PROVIDE PROPER MEDICAL CERTIFICATE FOR VESSEL'S MECHANIC, [name withheld]_x001C_ MIHAJHO, PASSPORT #003819._x001C_ ILO 147, ART. II
Fire Fighting
Issued 22 November 1995
Resolved
INACCURATE FIRE CONTROL PLAN.
Fire Fighting
Issued 22 November 1995
Resolved
HOLES IN FIRE MAIN PIPING MAIN DECK.
Fire Fighting
Issued 22 November 1995
Resolved
SOFT PATCHES ON INTAKE LINE ON PRIMARY PUMP.
Navigation
Issued 29 June 1995
Resolved
BRIDGE RUDDER ANGLE INDICATOR OUT OF ALIGNMENT. SOLAS 74/78.
Engineering
Issued 29 June 1995
Resolved
REPAIR OILY WATER SEPARATOR TO INDICATE PROPER 15PPM ALARM. MARPOL I/9,16
Fire Fighting
Issued 2 August 1994
Resolved
REPLACE WASTED AND LEAKING SECTION OF FIREMAIN LOCATED IN FRONT OF BOTTOM OF SUPERSTRUCTURE TO THE SATISFACTION OF THE CLASS SOCIETY PRIOR TO DEPARTURE.
Navigation
Issued 15 October 1991
Resolved
charts of local area not corrected up to date.
Navigation
Issued 15 October 1991
Resolved
current tidal tables not on board.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.