Records from 1990 to 2011. Most recent: operational control imposed, 21 January 2011.
Inspection history · 39
19 January 2011
COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3928893
21 November 2010
Ballast Water Examination · PII Safety Exam · ISPS II Exam · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3891625
13 July 2009
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3514362
3 May 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3466128
3 May 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3467181
3 May 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3467737
17 April 2009
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3455883
10 November 2008
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3350620
26 October 2007
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3087664
10 May 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2918018
1 March 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2880028
15 August 2006
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2748529
2 May 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2638989
24 April 2006
MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2632006
28 April 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2344636
28 April 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2347506
1 April 2005
MARPOL Annex V Examination · NPV Safety Exam · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2323904
19 February 2003
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1746477
15 February 2003
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1758963
13 February 2003
Ballast Water Examination · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1744438
24 November 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 295662
25 June 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 291184
25 September 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 282391
19 February 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 274868
15 August 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 431745
26 June 1998
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 417143
15 October 1997
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 408885
6 October 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 408581
7 January 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 398979
7 January 1997
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 399190
2 October 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 396032
18 February 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 376054
22 March 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 479736
14 March 1994
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 481492
3 February 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 355950
3 December 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 354773
7 August 1991
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 344957
22 September 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 339497
6 August 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 338687
Engineering › Steering Gear System › Pump
Issued 21 November 2010
Resolved
0936 - Steering Gear - No. 2 steering pump is leaking hydraulic oil in numerous areas. Repair to the satisfaction of the classification society and provide documentation attesting to the repairs. - SOLAS 74 I/II
Action required: 705 - Other - as specified
Due 28 November 2010
Resolved 28 November 2010
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. Chief Engineer replaced o-ring on pump and tested satisfactory.
Engineering › Fuel Oil Service System › Tank
Issued 21 November 2010
Resolved
0940 - Ballast Fuel and Other Tanks - Crew has installed a rubber hose as a sounding gauge on the diesel oil service tank due to faulty electronic tank level indicating gauge. Repair system to the satisfaction of classification society or provide approval from classification society for the current installation. - SOLAS 74 I/II
Action required: 705 - Other - as specified
Due 28 November 2010
Resolved 28 November 2010
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. A new gauge was order and replace, record reviewed and confirmed, sounding arrangement now satisfactory.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 21 November 2010
Resolved
0100 - Ship's Certificates and Document - The vessel cannot provide transfer procedures in accordance with 33CFR155.750. The vessel is prohibited from conduction bunkering operations in US waters until transfer procedures have been received and approved by USCG Marine Inspector. - 33CFR155.720, 33CFR155.750
Action required: 705 - Other - as specified
Resolved 26 November 2010
Resolution: Received, reviewed and accepted proper documentation from [name withheld] stating the deficiency was rectified. That they received updated oil tranfer procedures in accordance with 33 CFR 155.750
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 21 November 2010
Resolved
1499 - Other (Prop. & Aux Machinery) - Vessel conducted annual test however, air was used as a medium. Vessel is prohibited from conducting bunkering operations in U.S. waters until bunker line is static liquid pressure tested and written documentation is provided to US Coast Guard in accordance with 33 CFR 155.820 - 33CFR156.170 c 4, 33CFR156.170 f 3
Action required: 705 - Other - as specified
Resolved 26 November 2010
Resolution: Received, reviewed and accepted proper documentation from [name withheld] stating the deficiency was rectified. That the chief engineer had conducted a hydrostatic test of the bunker lines.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 3 May 2009
Resolved
A gasket at the cooling line of jacket water to the main engine was broken.
Action required: 705 - Other - as specified
Due 3 May 2009
Resolved 3 May 2009
Resolution: Repairs were effected by inspecting and renewing the gasket. See narrative of act# 3467181 for further information.
Navigation › Collision/Grounding Avoidance › Radar
Issued 17 April 2009
Resolved
The vessel was granted a Letter of Deviation to enter the Port of Corpus Christi with an inoperable Secondary Radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2009
Resolution: 20APRIL2009 Conducted a PSC administrative Deficiency Check. Received a class report/proper documentation satisfying the requirement.
Pollution Prevention/Response › Prevention Equipment
Issued 13 February 2003
No resolution recorded
OILY WATER SEPERATOR ALARM INOP AND MARPOL ANN I PANEL INDICATES DEFECT. OILY WATER SEPERATOR MAY NOT BE USED UNTIL CLASS RECOMMENDATION REPORT IS MADE. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 705 - Other - as specified
Resolution: WIRING CHECKED IN ALARM PANEL AND ONE WIRE FOUND WITH LOOSE CONNECTION. aLL ALARM PANEL WIRING CHECKED FOR TIGHT CONNECTIONS. aLARM AND VALUE FUNCTION TEST CARRIED OUT SATISFACTORILY AS PER ATTENDING CLASS SURVEYOR.
Lifesaving
Issued 24 November 2001
Resolved
Class surveyor to attend to the proper operation of STBD Lifeboat recovery system. Vessel crew unable to recover lifeboat due to leaking air line & malfunctioning pump.
Condition: Unknown
Due 24 November 2001
Resolved 25 November 2001
Lifesaving
Issued 24 November 2001
Resolved
Replace missing liferaft launching instructions for both port and starboardliferaft stations.
Condition: Unknown
Due 24 November 2001
Resolved 25 November 2001
Lifesaving
Issued 24 November 2001
Resolved
Replace food rations for both lifeboats which were open to air (not_x001C_ vacumed sealed). Port 9 & Stbd 6 for a total of 15 rations at 10.000 kjs per pack.
Condition: Unknown
Due 24 November 2001
Resolved 25 November 2001
Navigation
Issued 25 June 2001
Resolved
Secondary radar inoperable._x001C_ 33 CFR 164.37(a)
Condition: Unknown
Due 26 June 2001
Resolved 26 June 2001
Navigation
Issued 26 June 1998
Resolved
Secondary Radar inop vessel requested Letter of Deviation (LOD)
Condition: Unknown
Due 28 June 1998
Resolved 29 June 1998
Fire Fighting
Issued 6 October 1997
Resolved
VESSEL TO MAKE PERMINENT REPAIRS TO SUCTION SIDE OF FIRE MAIN PIPING TO THEBUILDG AND FIRE FIGHTING PUMP. CURRENTLY THERE IS A SOFT PATCH ON PIPE.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Unknown
Issued 6 October 1997
Resolved
VESSEL TO MAKE REPAIRS TO THE WASTED SECTION OF DRAIN PIPE TO OILY WATER SEPARATOR. REPARIS TO BE COMPLETED PRIOR TO USE OF OILY WATER SEPARATOR EQUIPMENT.
Condition: Unknown
Due 16 October 1997
Resolved 16 October 1997
Deck/Cargo
Issued 6 October 1997
Resolved
VESSEL TO REPAIR HYDRAULIC LEAK ON MOORING CAPSTAN FWD. CAPSTAN HAS SMALLLEAK AROUND SHAFT WORK ABOVE ABILITY OF SHIPS CREW AND REQUIRES OUTSIDE ASSISTANCE. SHIP CURRENTLY HAS A DRIP PAN UNDER TO CATCH OIL.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Navigation
Issued 7 January 1997
Resolved
GYROCOMPASS INOPERATIVE. REPAIR GYROCOMPASS.
Condition: Unknown
Due 7 January 1997
Resolved 7 January 1997
Lifesaving
Issued 18 February 1995
Resolved
Install explosion proof light fixture and switch in stbd paint locker, prior to next U. S. port, per SOLAS Chap II-1, Reg 45(10).
Condition: Unknown
Due 21 October 1996
Resolved 21 October 1996
Navigation
Issued 6 August 1990
Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ON BOARD AS REQUIRED BY 33CFR88.05.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Documentation
Issued 6 August 1990
Resolved
VESSELS OIL RECORD BOOK DID NOT CONTAIN TIME OF LAST DISCHARGE AS REQUIRED BY 33CFR151.25(d).
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Documentation
Issued 6 August 1990
Resolved
VESSEL DID NOT HAVE A DISCHARGE OF OIL PLACARD POSTED AS REQUIRED BY 33CFR155.450(a).
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Documentation
Issued 6 August 1990
Resolved
VESSELS OIL TRANSFER PROCEDURES DID NOT CONTAIN ALL INFORMATION REQUIRED BY33CFR155.750.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Navigation
Issued 6 August 1990
Resolved
VESSELS B.A. COAST PILOT VOL 8 MISSING SUPP.8 AND VESSELS B.A. LIGHT LIST VOL. G 1987ed. WAS NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(b).
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Lifesaving
Issued 6 August 1990
Resolved
THREE OF THE VESSELS 4 SELF-IGNITING LIGHTS FOR RING BUOYS WERE FOUND TO BEIN OPERATIVE THIS IS A VIOLATION OF SOLAS 74 CH III REG 7.1.3.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Fire Fighting
Issued 6 August 1990
Resolved
VESSELS INTERNATIONAL SHORE TIE CONNECTION WAS MISSING THE GASKET REQUIRED BY SOLAS 74 CH.II-2REG19.4.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Fire Fighting
Issued 6 August 1990
Resolved
VESSELS FIRE HOSE NOZZLES WERE NOT OF THE DUEL PURPOSE TYPE REQUIRED BY SOLAS 74. CH II-2 REG 4.8.4.
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990
Fire Fighting
Issued 6 August 1990
Resolved
VESSEL WAS MISSING 5 FIRE HOSE NOZZLES THIS IS A VIOLATION OF SOLAS 74 CH.II REG 4.7.1
Condition: Unknown
Due 6 August 1990
Resolved 6 August 1990