Records from 2016 to 2026. Most recent: inspection, 7 January 2026.
Inspection history · 13
7 January 2026
Internal Structural Exam · Annual Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8286948
26 August 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7999149
1 August 2024
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7972175
1 February 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7859324
4 December 2023
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7833497
15 August 2023
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7759051
11 January 2022
COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7378859
4 June 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7215186
11 June 2020
Hull Examination · Drydock Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6973598
21 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6689488
11 June 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6441107
7 June 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6168754
7 June 2016
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5902445
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2024
Resolved
Remote Fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. MI observed the fuel cut off valve was not properly labeled. Make repairs to the satisfaction of the attending Marine Inspector. 46 CFR 185.30-20 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2024
Resolved 28 August 2024
Resolution: Received photo evidence that this deficiency has been corrected. All sat.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 26 August 2024
Resolved
The vessel must comply with the application, design, equipment, personnel, procedures, and recorded requirements of 33CFR 151,155, and 156. MI observed that the Garbage placard was outdated. Replace Placard with newest version and to the satisfaction of the MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2024
Resolved 28 August 2024
Resolution: Received photo evidence that this deficiency has been corrected. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2024
Resolved
Remote Fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation. MI observed the fuel cut off valve was not properly labeled. Make repairs to the satisfaction of the attending Marine Inspector.
46 CFR 185.30-20 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2024
Resolved 28 August 2024
Resolution: Received photo evidence of correction of the deficiency. All sat.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 26 August 2024
Resolved
The vessel must comply with the application, design, equipment, personnel, procedures, and recorded requirements of 33CFR 151,155, and 156. MI observed that the Garbage placard was outdated. Replace Placard with newest version and to the satisfaction of the MI.
46cfr 184.702
16C
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2024
Resolved 28 August 2024
Resolution: Received photo of the correction of the deficiency. All Sat.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 27 May 2022
Resolved
Mount correct donning placard for life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2022
Resolved 20 July 2022
Resolution: Received, reviewed, and accepted photo of mounted life jacket donning placard.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 27 May 2022
Resolved
Labeling of location of life jackets is missing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2022
Resolved 20 July 2022
Resolution: Received, reviewed, and accepted photo of labeling of location of life jackets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 May 2022
Resolved
Outboard engines' gasoline fuel shut off instructions not posted.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2022
Resolved 20 July 2022
Resolution: Received, reviewed and accepted photo of fuel shut off instructions posted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 May 2022
Resolved
Fuel system's quick disconnect label missing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 May 2022
Resolved 20 July 2022
Resolution: Received, reviewed and accepted photo showing fuel system's "Quick Disconnect" label posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2020
Resolved
Life buoy plug was rotten. Replace life buoy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2020
Resolved 12 June 2020
Resolution: Life buoy was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2020
Resolved
Portable fire extinguisher did not have annual maintainance and inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2020
Resolved 15 June 2020
Resolution: New extinguisher was purchased, inspected, and tagged.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 11 June 2018
Resolved
Provide suitable replacement for 49 dry rotted life jackets.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2018
Resolution: Vessel owner provided photo documentation for new life jackets.
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 June 2018
Resolved
Life jacket placard was missing, provide posted life jacket placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2018
Resolved 11 June 2018
Resolution: Vessel owner provided photo documentation of new life jacket placard.
Lifesaving › Lifebuoys › Approval
Issued 11 June 2018
Resolved
Improper retro tape on life buoy. Replace tape with SOLAS approved retro.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 July 2018
Resolved 11 June 2018
Resolution: Vessel owner replaced old retro with proper solas retro.