Records from 1993 to 2009. Most recent: inspection, 14 July 2009.
Documentation record
Registered dimensions (L × B × D)46.0 ft × 14.0 ft × 6.7 ft
Registered tonnagegross 28 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARKLEY'S MARINA, INC. · BALTIMORE, MD, UNITED STATES · built 1990
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portRIDGE, MD
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Net Ton
28 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 29
14 July 2009
Annual Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3535153
18 March 2008
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3169067
10 April 2007
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2905052
22 August 2006
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2756517
3 August 2006
Deficiency Check · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2735702
15 March 2006
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2602847
14 July 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2427849
8 September 2004
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2192311
4 August 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2155698
7 May 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1788561
17 April 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1604844
4 March 2002
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1598961
23 October 2001
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1074979
26 June 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1401573
17 April 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1446920
17 March 2000
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1430888
5 April 1999
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1127672
19 June 1998
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 801863
19 May 1998
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 792447
23 April 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1380877
7 March 1997
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1439844
2 April 1996
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1441055
29 March 1996
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1083503
17 April 1995
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1174719
1 October 1994
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1169672
27 June 1994
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 960461
23 March 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 961654
4 May 1993
Initial Certification · Plan Review "T" Boat
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1412555
26 April 1993
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1146699
Engineering › Bilge Water Management System › Pump
Issued 14 July 2009
No resolution recorded
Perm. mount Rule 2000 pump in forward compt.
Due 10 August 2009 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Pump
Issued 14 July 2009
No resolution recorded
Procure and place in service a UL listed electrical bilge pump in aft steering compt.
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 14 July 2009
No resolution recorded
Show proof of enrollment in DOT approved drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 14 July 2009
No resolution recorded
Show proper operation of fireboy system.
Action required: 701 - Prior to carriage of passengers/cargo
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 July 2009
No resolution recorded
Procure and place in service new Coast Pilot 3 and USCG Light List.
Due 12 August 2009 — due date passed with no resolution recorded
Lifesaving › Lifefloat › Float-free Link
Issued 14 July 2009
No resolution recorded
Procure and place in service new, CG approved weak-link.
Action required: 701 - Prior to carriage of passengers/cargo
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 10 April 2007
Resolved
Provide proof of enrollment in drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2007
Resolved 11 April 2007
Resolution: Provided valid proof of enrollment in testing program. Verified by marine inspector.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 10 April 2007
Resolved
Renew life lines for buoyant apparatus.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2007
Resolved 11 April 2007
Resolution: Renewed all life lines for buoyant apparatus. Verified by marine inspector.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 10 April 2007
Resolved
Tighten shaft seal due to excessive leakage.
Due 20 April 2007
Resolved 11 April 2007
Resolution: Tightened shaft seal. Verified by marine inspector.
Engineering › Steering Gear System › Rudder Bearing
Issued 10 April 2007
Resolved
Tighten rudder packing due to excessive leakage.
Due 20 April 2007
Resolved 11 April 2007
Resolution: Tightened shaft packing, verified by marine inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 3 August 2006
Resolved
Provide annual service for all portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2006
Resolution: Verified servicing of all portable fire extinguishers.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 3 August 2006
Resolved
Provide annual service for fixed fire extinguishing system (fire boy) for engine compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2006
Resolution: Verified annual servicing of fixed fire system.
Communications › Alarms/Indicators › High Water Alarm
Issued 3 August 2006
Resolved
Provide operational high water alarm for midship compartment, area below main cabin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 August 2006
Resolution: Verified high water alarm was repaired and operating properly.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 August 2006
Resolved
Failed to provide vessel for inspection within 3 months of COI date.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2006
Resolved 3 August 2006
Resolution: Completed annual examination.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 August 2006
Resolved
Owner failer to repair deficiencies on vessel prior to carrying passengers.
Condition: Placed in Improper Service
Due 21 November 2006
Resolved 24 August 2006
Stability › Watertight Integrity › General
Issued 3 August 2004
Resolved
Prior to carrying passengers vessel must complete CG credit drydock exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 September 2004
Resolved 8 September 2004
Construction/Loadline
Issued 17 March 2000
Resolved
PROVIDE SEPARATE AUDIO/VISUAL BILGE ALARM AT OPERATING STATION FOR FWD BILGE.
Condition: Unknown
Due 17 April 2000
Resolved 17 July 2000
Navigation
Issued 17 March 2000
Resolved
REPLACE BUSHINGS ON STEERING LINKAGE.
Condition: Unknown
Due 17 April 2000
Resolved 17 July 2000
Accommodation/Occupational Safety
Issued 17 March 2000
Resolved
SECURE DECK RAILS FROM LIFTING UP OUT OF GUNWALE.
Condition: Unknown
Due 17 April 2000
Resolved 17 July 2000
Construction/Loadline
Issued 17 March 2000
Resolved
REPAIR FWD BILGE ALARM SWITCH.
Condition: Unknown
Due 17 April 2000
Resolved 17 July 2000
Accommodation/Occupational Safety
Issued 19 May 1998
Resolved
REPAIR BROKEN GLASS WINDOW PORT SIDE OF CABIN.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
PROVIDE FIRST AID KIT.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Documentation
Issued 19 May 1998
Resolved
PROVIDE CURRENT FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Navigation
Issued 23 April 1997
Resolved
There was no updated tide table onboard._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 May 1997
Resolved 22 May 1997
Unknown
Issued 23 April 1997
Resolved
There was no log book as required._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 May 1997
Resolved 22 May 1997
Lifesaving
Issued 23 April 1997
Resolved
Several of the PFDs had deteriorated retro reflective tape._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 May 1997
Resolved 22 May 1997
Construction/Loadline
Issued 7 March 1997
Resolved
The hose connections on the MSD intake system is not double clamped as required. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 April 1997
Resolved 22 May 1997
Engineering
Issued 7 March 1997
Resolved
The hose connections on the main engine cooling system were not double clamped as required._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 April 1997
Resolved 22 May 1997