Records from 1990 to 2026. Most recent: inspection, 5 August 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 42
5 August 2026
Vessel Attendance · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8456209
9 April 2026
Vessel Attendance
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8345417
15 October 2025
Internal Structural Exam · Vessel Attendance · COI Inspection · Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8254655
16 July 2025
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8187099
10 July 2025
Bulk Liquid Transfer Monitor
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8182138
16 October 2024
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8019786
26 September 2024
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8009735
19 January 2024
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7875517
13 July 2023
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7741784
28 November 2022
Examination of Repairs · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7600556
24 March 2016
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6143395
2 March 2014
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 4808797
26 June 2012
Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4357146
15 December 2010
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3911323
10 November 2010
Internal Structural Exam · Administrative Inspection · Re-Inspection · Drydock Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3889097
17 April 2009
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3454699
8 October 2008
Deficiency Check · Drydock Exam · Administrative Inspection · Internal Structural Exam · Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3345224
12 July 2007
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2992280
28 September 2006
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2788902
17 June 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2392724
17 December 2004
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2246815
22 September 2003
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1909999
16 July 2002
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1650803
23 August 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1071179
21 August 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1376716
2 August 2000
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381983
13 July 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391060
24 July 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1364824
10 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112927
10 July 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371907
12 July 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1377785
11 July 1995
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1454237
31 May 1995
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1183557
1 July 1994
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1363030
13 September 1993
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1144544
26 August 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1415884
8 October 1992
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 943514
4 September 1992
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 936492
30 March 1992
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 952068
27 August 1991
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1247120
16 April 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906633
22 August 1990
Initial Certification · Plan Review "T" Boat · Initial Construction-Excluding Oversight · Hull Examination · Inclining Experiment
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232523
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2026
Resolved
Shutoff valves, installed so as to close against the
fuel flow , must be fitted in the fuel supply lines.
Emergency fuel shutoff valve in engine room was
not operable from weather deck. 46 CFR 182.455(b)(4)
Action required: 60 - Rectify deficiencies prior to movement
Due 31 December 2026
Resolved 10 April 2026
08 - Alarms › N/A - No Subsystem › General alarm
Issued 9 April 2026
Resolved
All vessels with overnight accommodations must be
equipped with a general alarm system. The public address
system required by 184.610 may be used to sound the
general alarm.
Vessel has no general alarm system installed. 46 CFR 183.550
Action required: 60 - Rectify deficiencies prior to movement
Due 31 December 2027
Resolved 10 April 2026
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 9 April 2026
Resolved
An interconnected detection and alarm must: consist of multiple smoke detectors as meeting UL 217 and be installed such that the actuation of an alarm in one area results in both audible and visual alarms in all areas required to be protected by interconnected detection and alarm system.
Vessel fire detection system is not operable; does not
activate all alarms in test mode. 46 CFR 181.450
Action required: 60 - Rectify deficiencies prior to movement
Due 31 December 2026
Resolved 10 April 2026
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 9 April 2026
Resolved
An interconnected detection and alarm must: consist of multiple smoke detectors as meeting UL 217 and be installed such that the actuation of an alarm in one area results in both audible and visual alarms in all areas required to be protected by interconnected detection and alarm system.
No smoke detector provided in the auxiliary space between galley and machinery space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2026
Resolved 2 June 2026
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 9 April 2026
Resolved
An interconnected detection and alarm must: consist of multiple smoke detectors as meeting UL 217 and be installed such that the actuation of an alarm in one area results in both audible and visual alarms in all areas required to be protected by interconnected detection and alarm system.
No visual alarms in machinery space
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 December 2026
Resolved 2 June 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 October 2025
Resolved
MI was not able to inspect area in vicinity of the MSD due to excess liquid in the bilge. Pump out for inspection.
Action required: 705 - Other - as specified
Resolved 27 October 2025
Resolution: Pumped out water. Issued Worklist item #12 due to corrosion.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2025
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. 4 life jacket whistles must be replaced to comply with the required amount.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2026
Resolution: MI attended vsl and verfied satisfactory whistle replacement for all 4 whistles.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 October 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel had a crack in the overhead on the port side on of the engine room and a hole through the PORT side engine room bulkhead that must be repaired prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 January 2026
Resolution: Conducted NDT of weld repair to the satisfication of attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 October 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. MI observed 02 fire extinguishers past their annual servicing date.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 January 2026
Resolution: MI attended vsl and verfied extinguisher servicing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. MI found the following leaks on the machinery equipment.
1) F/O leak on port ship service diesel piping.
2) Fuel oil transfer pump leak on the mechanical seal.
3) Fire pump housing leak
4) Bilge pump supply threaded pipe connection and discharge piping union flange.
5) Jacket water leak at the level indicator on the starboard outboard main diesel engine.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 26 January 2026
Resolution: MI witnessed all leaks were secured/fixed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2025
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. MI found material condition of fuel oil supply hose to be degraded and in need of replacement on the port ship service diesel generator.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 January 2026
Resolution: MI attended vsl and verfied satisfactory hose replacement.
01 - Certificates & Documentation › 012 - Crew Certificates › Record of employment
Issued 18 July 2023
Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. The mate and two deck hands were not part of the employers drug testing program at the time of the COI inspection. Provide a crew that is subject to the employers drug testing program or enroll the crew members on board prior to issuance of the Certificate of Inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: Vessel rep provided documentation for all crew members enrolled in DAPI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel. The vessel had 58 of the required 60 serviceable life jackets.
46 CFR 180.71
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: 12 additional life jackets were provided with the correct attachments
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 July 2023
Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. The emergency escape hatch to the bow of the vessel was not operable.
46 CFR 177.500 (h)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: The emergency escape hatch was operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 July 2023
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment,
other than small buoyancy compartments, under all practicable conditions. The bilge suction aft of the generator room was not operating as designed. All bilge suction must be tested.
46 CFR 182.500
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: All 8 of the bilge suctions in the rudder room (01), filter room (01), generator room (02), engine room (02), forward accommodation space (01), and forepeak (01) were tested satisfactorily.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 18 July 2023
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected spaces including fuel tanks, and may require the vessel to effect permanent repairs. A crack was found the above the watertight bulkhead in the forward section of the engine room.
46 CFR 176.600(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: The crack above the door was welded and grinded back satisfactorily.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 18 July 2023
Resolved
Stability information (stability details indicated on the Certificate of Inspection, a stability letter, or a stability booklet), is required on certain vessels. Vessel did not have valid stability letter on board.
46 CFR 178.210
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: The stability letter was provided for the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 18 July 2023
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Deck rails must include a top rail with the minimum height required by this section, and lower courses or equivalent protection as required by this section. Rails must be at least 910 millimeters (36 inches) high. Rail courses or the equivalent must be installed between a top rail required and the deck so that no open space exists that is more than 305 millimeters (12 inches) high. Vessel did not have required deck rails and courses on aft deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: Vessel provided adequate coursing for the back deck
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 18 July 2023
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected spaces including fuel tanks, and may require the vessel to effect permanent repairs. The deck framing under the engine room bilge in way of the starboard emergency escape hatch in the engine room was broken and unstable.
46 CFR 176.600(d)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: The deck framing under the stbd emergency hatch was repaired
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 18 July 2023
Resolved
A hydrostatic release unit when used in a float-free arrangement must be approved under approval series 160.062 or 160.162 or other standard specified by the Commandant. The hydrostatic release on the survival craft and EPIRB did not have the date scratched out in accordance with the QSpec.
46 CFR 180.130(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: The hydrostatic releases had the date scratched out.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 18 July 2023
Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. The Emergency broadcast placard had the wrong call sign on it.
46 CFR 184.506
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: The Emergency Broadcast Placard had the correct call sign
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 18 July 2023
Resolved
All electrical installations shall be to the satisfaction of the OCMI. The distribution panel in the operation station has uncovered blanks.
46 CFR 183.01-15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2023
Resolution: The distribution panel had the blank inserted
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 10 November 2010
Resolved
Vsl to provide exhaust lagging on all 4 MDEs & 2 Gensets prior to operating for hire.
Action required: 705 - Other - as specified
Due 10 January 2011
Resolved 15 December 2010
Resolution: Exhaust lagging SAT on all engines.
Construction/Loadline › Structures › Air Pipe
Issued 10 November 2010
Resolved
Clean/replace the flame screens on all fuel vents on the STBD side of deck area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 January 2011
Resolved 15 December 2010
Resolution: All vents were SAT.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 July 2007
Resolved
Gaurd over ballast pump couling was missing. Manufacture/replace guard over coupling.
Due 11 August 2007
Resolved 12 July 2007
Resolution: Guard installed over coupling.
Lifesaving › Lifefloat › Paddle
Issued 11 July 2007
Resolved
Lifefloat paddles need to be lashed down correctly.
Due 11 August 2007
Resolved 12 July 2007
Resolution: Lifefloat paddles attached properly.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 July 2007
Resolved
Masthead light and upper NUC light extinguished. Replace lamps.
Due 11 August 2007
Resolved 12 July 2007
Resolution: All Nav lights functioning properly and burning brightly.
Communications › Visual Communication › Signalling Lamp
Issued 11 July 2007
Resolved
Watertight door light for E/R is not working. Repair to working condition.
Due 11 August 2007
Resolved 12 July 2007
Resolution: All WTD lights working correctly.
Lifesaving › Buoyant Apparatus
Issued 22 September 2003
Resolved
Service 6-man life float and 5 12-man life floats. LEGACY COMPONENT DESC: Life float
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2003
Resolved 22 September 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 22 September 2003
Resolved
Renew hose on CO2 bottle on paint locker. LEGACY COMPONENT DESC: Paint locker
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2003
Resolved 22 September 2003
Stability › Watertight Integrity
Issued 22 September 2003
Resolved
Renew gasket on watertight door leading to main deck. LEGACY COMPONENT DESC: Gasket
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2003
Resolved 22 September 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 22 September 2003
Resolved
Repair trip hazard on tile decking at stairway leading to passenger seating compartment. LEGACY COMPONENT DESC: trip hazard
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2003
Resolved 22 September 2003
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 22 September 2003
Resolved
Install new mounting bracket on CO2 bottle on mess deck. LEGACY COMPONENT DESC: Mounting Bracket
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2003
Resolved 22 September 2003
Lifesaving › Lifebuoys
Issued 22 September 2003
Resolved
Renew life ring on 02 deck near life floats due to cracked lament. LEGACY COMPONENT DESC: condition
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2003
Resolved 22 September 2003
Lifesaving › Buoyant Apparatus
Issued 22 September 2003
Resolved
Provide 2 oars for 1 12-man life float. LEGACY COMPONENT DESC: life float
Action required: 17 - Rectify deficiencies prior to departure
Due 22 October 2003
Resolved 22 September 2003
Lifesaving
Issued 21 August 2001
Resolved
REMOVE OIL FROM BILGE.
Condition: Unknown
Due 23 August 2001
Resolved 23 August 2001
Accommodation/Occupational Safety
Issued 21 August 2001
Resolved
REPLACE CRACKED WINDOW IN PILOT HOUSE.
Condition: Unknown
Due 23 August 2001
Resolved 23 August 2001
Documentation
Issued 21 August 2001
Resolved
PROVIDE PROOF OF CURRENT SAFETY REDIO TELEPHONE CERTIFICATE.
Condition: Unknown
Due 23 August 2001
Resolved 23 August 2001
Lifesaving
Issued 26 August 1993
Resolved
RENEW 2 RING BUOYS WHICH HAVE DETERIORATED GRAB LINES.
Condition: Unknown
Due 10 September 1993
Resolved 13 September 1993
Navigation
Issued 26 August 1993
Resolved
UPDATE ALL CHARTS AND PUBLICATIONS TO MOST CURRENT EDITIONS.
Condition: Unknown
Due 10 September 1993
Resolved 13 September 1993
Engineering
Issued 8 October 1992
Resolved
_x001C_ PROVE OPERATION OF PRESSURE RELIEF VALVES ON AIR RECEIVER TO CG INSPECTOR.
Condition: Unknown
Due 16 October 1992
Resolved 30 October 1992
Engineering
Issued 4 September 1992
Resolved
PROVE OPERATION OF PRESSURE RELIEF VALVES ON AIR RECIEVERS TO CG INSPECTOR.
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Accommodation/Occupational Safety
Issued 4 September 1992
Resolved
REPLACE PLASTIC CLOTHES DRYER DUCT WITH A METAL DUCT.
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Electrical
Issued 4 September 1992
Resolved
PROVIDE CHAFING PROTECTION FOR ELECTRICAL CABLES WHERE THEY PASS THROUGH FRAMES ON THE STBD SIDE OF THE LAUNDRY ROOM AND THE PORT AND STBD RUNNING LIGHT CABLES AFT OF THE PILOT HOUSE.
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Fire Fighting
Issued 27 August 1991
Resolved
SERVICE ALL PORTABLE AND SEMI-PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Navigation
Issued 27 August 1991
Resolved
PROVIDE ONBOARD A COMPASS DEVIATION CARD.
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Navigation
Issued 27 August 1991
Resolved
OBTAIN A FCC WAIVER FOR REQUIRED RADIO EQUIPMENT TO OPERATE MORE THAN 100 NM FROM LAND.
Condition: Unknown
Due 27 August 1991
Resolved 27 August 1991
Documentation
Issued 27 August 1991
Resolved
UPDATE CERTIFICATE OF DOCUMENTATION TO SHOW VESSELS'S CORRECT GROSS_x001C_ TONNAGE.
Condition: Unknown
Due 21 October 1991
Resolved 21 October 1991
Documentation
Issued 22 August 1990
Resolved
PROVIDE ON BOARD A VALID RADIO STATION LICENSE AND RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Unknown
Issued 22 August 1990
Resolved
PROVIDE ON BOARD A COAST GUARD ISSUED STABILITY LETTER.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Navigation
Issued 22 August 1990
Resolved
PROVIDE ON BOARD VESSEL NAVIGATION CHARTS FOR APPLICABLE AREAS OF OPERATION, TIDE TABLES, LIGHT LIST, COAST PILOTS, NOTICE TO MARINERS, AND 46 CFR SUBCHAPTER "T".
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Documentation
Issued 22 August 1990
Resolved
PROVIDE ON BOARD VESSEL ORIGINAL CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990